DP2 System
CONTENTS
System Overview 3
Offshore Rig or Ship DP2 Package 3
Main Generator Diesel Skid 3
Main Generator Diesel Engines 3
Main Generators 5
Instrumentation & Control 5
Electrical System 6
Containerized Diesel Generator Sets 6
Fuel Oil System (Tanks, Supply, Pumps, Transfer Pumps and Piping) 9
Lubrication Oil System for Thrusters 9
Duplex DP, Thruster Control & Joystick Systems (w/ Diagram) 9
Fresh Water Cooling System (Box Coolers, VSD Coolers and Expansion Tanks 10
Variable Speed Drives, UPS’s and Frequency Converters 10
Switchboards 10
Block Diagram - Main Power Distribution 10
Generators and DP2 System are Lloyds Marine Certified Complete with all Controls and Switchgear.
All Units are NEW 2008, never put into service, warranty transferable.
Product as follows:
! 8 / ea. Units 3516B rated @ 1,840-kW cont. 690 volt 60 HZ @ 1,800 rpm Hyundai Generators
! 3 / ea. Units 3516B rated @ 1,840-kW cont. 440 volt 60 HZ @ 1,800 rpm Hyundai Generators
! 1 / ea. Unit 3412C rated @ 500-kW emergency standby 440 volt 60 HZ @ 1,800 rpm CAT SR4B Generator
! 1 / ea. NEW CAT Synchro System for Gensets.
! 8 / ea. NEW Alstom MSV 3000 VSD Drives provided.
! Not provided or included - 8 / ea. Wartsila FP Retractable Thrusters 1.6MW
! 8 / ea. NEW Hyundai Thruster Motors 1.6MW provided.
! 1 / ea. Complete Alstom DP2 Duplex System provided, all controls, drawings and certs available.
! 1 / ea. Hatenboer Fresh Water Osmosis System
! 1 / ea. Atlas Copco Air Compressors Model LT3-10 KE (10 bar (g) pressure)
! Auxiliary Systems:
3 / ea. 1,840-kW Prime 440 Volt Caterpillar Diesel Hyundai Generator Skids, Containerized equipped with ventilation
insulation and exhaust for the supply of 440 volt for auxiliary systems to be transformed to 230VAC 1 phase + neutral.
! Emergency Systems:
1 / ea. 500-kW Prime 440 Volt Cat Diesel Cat Generator Skid, Containerized equipped with ventilation insulation and exhaust
for the supply of 440 volt for emergency systems to be transformed to 230VAC 1 phase + neutral and 24VAC 1 phase.
The Diesel Engines have a starting battery capacity for a minimum of 3 starts of each engine. The Emergency Generator has a
minimum starting battery capacity for a minimum of 6 automatic starting attempts and 3 manual starting attempts.
-Additional Information:-
Diesel Oil:
The Diesel Engine complies with conditions in accordance with ISO 3046/l
Turbocharger: The oil may be mineral oil or synthetic oil having a viscosity of 30-55 cSt/50deg.C.
Output particulars:
8 / ea. Engines are dedicated to the Thruster Power:
Engine output Min 1,920-kW
Output speed: 1,800 rpm
Main Generators:
All the Generators are supplied with:
! Automatic Voltage Regulator
! Equipment for parallel operation
! Anti Condense Heater
! PT-100 temperature sensors in windings
! PT-100 temperature sensors in bearings
! MCT Brattberg cable entry in container
! Termination Box for power cables
! Foundations.
The Control System is laid out also to monitor and interface all critical failures and alarm situations for the Engines,
Generators and Auxiliary Systems.
Electrical System:
The Thruster Power Distribution Systems are laid out for 690 VAC, 440VAC and 230 VAC/60Hz systems and 24 VDC
Systems and to be controlled from the ICS Operating Stations.
NOTE:
Each Thruster Controller is integrated with the Local Control Panel of its corresponding Thruster.
Switchboards:
Thruster Main 690V Power Distribution Panel:
Four [4] Main Distribution Panels
■ Floor-Mounted
The Distribution Boards provide power to the equipment listed and shown in the Auxiliary Power Distribution Block
Diagram.