Barksdale 425
Barksdale 425
Barksdale 425
Transducers
General Industrial Transducer (Amplified) Series 423, 425, 426
Applications
Oil pressure hydraulics
Cranes
Presses
Gas metering
Vacuum machinery packaging
General Specifications*
Accuracy (LH & R): ±0.25% BSL Pressure Connection: 1/4”-18 NPT male
Long Term Stability: ±0.5% FSO of calibration curve Response Time: 1 kHz (typ)
Typical Life Cycle: 100 million cycles Electrical 3 conductor for voltage series and 2
Proof Pressure: 2 times rated pressure or 13,000 psi max. Connection: conductor for current series, 24 awg, PVC
(884 bar), whichever is less jacketed, shielded cable, 3 ft. (1 m) long with
integral strain relief and case ground.
Input:
423: Excitation voltage: 9 to 30 VDC Temperature Ranges:
Operating: 0° to 160°F (-18° to 71)°C
426: Excitation voltage: 14 to 30 VDC
Compensated: 30° to 160°F (-1° to 71)°C
425: Excitation voltage: 12 to 32 VDC
Storage: -40° to 185°F (-40° to 85)°C
Supply Current: 15 mA maximum (no load)
Temperature Shift:
Min. Load Resistance: 2K ohms (voltage series only)
Zero & Span: 0.0125% per °F over compensated range,
Output: 75°F reference (±1% of FSO over temp.
423: Output: 0.5 to 5.5 VDC range)
Full scale output: 5.0 VDC ± 0.8%
Vibration: 15 g’s, 10-2000 Hz, MIL-STD 202
Zero output: 0.5 VDC ± 0.4%
Shock: 50 g’s, 11 ms, MIL-STD 202 Method 213,
426: Output: 1 to 11 VDC
Cond. G.
Full scale output: 10 VDC ± 0.4%
Zero output: 1.0 VDC ± 0.2% Built-in Protection: Conducted & radiated RF emissions/
interference to EN 55011
425: Output: 4 to 20 mA
Full scale output: 16 mA ± 0.4% IEC 801-2, -3, -4, -5, and -6
Zero output: 4 mA ± 0.2%
EN/IEC 6100-4-2, -3, -4, -5, -6
Wetted Parts: 17-4 PH & 300 series stainless steel
Enclosure: NEMA 4, 300 series stainless steel Refer to engineering drawing for details.
* See product configurator for additional options.
Weight:
423 & 426: 7.4 oz. (221 grams) to 1000 psi
9.9 oz. (281 grams) 2,000 psi and higher
Wiring Code
423, 425 & 426 425: 7.4 oz. (210 grams) to 1000 psi
T5/H5/T4/H4 T2 H3 9.4 oz. (266 grams) 2,000 psi and higher
1 A Red + Excitation
3 B Black + Output Warranty: 3 year warranty
2 C Green Common
4 D White Case Ground
- - Bare Shield
1
General Industrial Transducer (Amplified) Series 423, 425, 426
Technical Drawings
1-1/8
CABLE
CONNECTOR
(H5)
2-7/16
STANDARD DIN
CONNECTOR
(T5)
3211 Fruitland Avenue • Los Angeles, CA 90058 • 800-835-1060 • Fax: 323-589-3463 • www.barksdale.com
See Barksdale’s Standard Conditions of Sale • Specifications are subject to modification at any time • Bulletin #R0032-B • 09/07 • ©2007 • Printed in the U.S.A. 2