Genspec GS4200: General Purpose Pressure Transmitter
Genspec GS4200: General Purpose Pressure Transmitter
Genspec GS4200: General Purpose Pressure Transmitter
Vers. 20/1/Eng
Genspec® GS4200 General Purpose Pressure Transmitter
Technical Data
Description
The GENSPEC GS4200 pressure transmitter is Standard accuracy is ±0.25% with an over pressure limit of
designed to meet the operational requirements of twice the rated pressure range, this together with easy access
demanding pressure measurement applications for re-calibration affirm the excellent design. All models
where good quality, fast delivery and low cost are of are supplied with integral 1/4” BSP or alternative pressure
connections. Optional higher accuracy, outputs and electrical
the highest priority.
connections are available. The all titanium alloy wetted parts
The unique Silicon-on-Sapphire sensor technology provides offer unbeatable corrosion resistance. Versions are also
outstanding performance and gives excellent stability over available offering IP66 sealing for installations requiring high
a wide temperature range. The advanced sensor design levels of environmental protection.Applications for the GS4200
consists of a piezoresistive silicon strain gauge circuit, which is include the continuous monitoring of hydraulic systems with
epitaxially grown onto the surface of a sapphire diaphragm to oil, gas, water and other process liquids, industrial, medical
form a single crystalline structure.The sapphire sensor element and aerospace industries. Also ideal for the measurement and
is then molecularly bonded to a titanium alloy sub-diaphragm. control of pressure in refrigeration, pneumatic, compressor,
This enables the sensor to endure higher over- pressures and HVAC and engine monitoring systems.
provides superb corrosion resistance. The sensor exhibits
An optional ATEX and IECEx approved version of this product
virtually no hysteresis and excellent long-term stability. With
is available for explosion protection for flammable gases (zone
outstanding insulation properties, the sapphire substrate allows
0), dusts (zone 20) and mining areas (group I M1).
the sensor to operate over a very wide temperature range
without loss of performance. DNV GL rules for classification of ships, high speed & light craft
and DNV GL offshore standards.
Dimensions
(in mm)
~35
ELECTRICAL CONNECTION (mA)
PG9
Pin No. 2 wire
1 +supply
2 4-20mA signal
3 not fitted
to case
~126
Technical Data
Standard Pressure Ranges 0 – 1 bar Vac; 0 – 0.5 bar; 0 – 1 bar; 0-2.5 bar; 0-6 bar; 0 – 10 bar; 0-16 bar; 0 – 25 bar; 0 – 100 bar; 0 – 250 bar; 0-400 bar; 0 –
(bar): 600 bar; 0-1,000 bar; 0 – 1,500 bar (other ranges available)
Standard Pressure Ranges 0-30 in Hg; 0-7.5 psi; 0-15 psi; 0-30 psi; 0-100 psi; 0-150 psi; 0-200 psi; 0-300 psi; 0-1,500 psi; 0-3,000 psi; 0-6,000 psi; 0-8,700
(psi): psi; 0-15,000 psi; 0-20,000 psi (other ranges available)
Overpressure Safety: 4x for 0.5 bar range; 2x for ranges -1 bar to 600 bar; 1.5x for 1,000 bar range; 1.1x for 1,500 bar range
4 – 20 mA: RL < [UB - 10 V] / 20 mA (e.g. with supply voltage (UB) of 36 V, max. load (RL) is 1300 Ω) 10 mV/V: n/a; 0 – 5 V: max.
Load Driving Capability:
load RL > 5 KΩ; 0 – 10 V: max. load RL > 10 KΩ
Accuracy NLHR: ≤ ±0.25 % of span BFSL (Optional higher accuracy version of ≤ ±0.1 % of span BFSL available)
Zero Offset and Span ±0.5 %FS at room temperature (GS4201: ±1 mV); ±5 %FS (approx.) adjustment with easy access trimming potentiometers on
Tolerance: amplified versions only
Operating Ambient
-40 °C to +85 °C (-40 °F to +185 °F)
Temperature:
Operating Media
-50 °C to +125 °C (-58 °F to +257 °F)
Temperature:
Storage Temperature: +5 °C to +40 °C (+41 °F to +104°F) Recommended Best Practice
Temperature Effects: ±1.5 %FS total error band for -20 °C to +70 °C. Typical thermal zero and span coefficients ±0.015 %FS /°C
Ex II 1 G Ex ia IIC
T4 Ga (zone 0)
ATEX/IECEx Approval
Ex II 1 D Ex ia IIIC T135 °C Da
Option (4-20 mA version n/a n/a n/a
(zone 20)
only):
Ex I M 1 Ex ia I Ma (group 1
M1)
Ui = 28 V
Ii = 119 mA
Pi = 0.65 W
Li = 0.1 µH
ATEX/IECEx Safety Values: n/a n/a n/a
Ci = 74 nF
Temperature Range = -20 °C
to +70 °C
Max. cable length = 45 m
DNV GL Approval Class: Temperature: D; Humidity: B; Vibration: B; EMC: B; Enclosure: C (contact sales for more information)
Electromagnetic
Emissions: EN61000-6-3; Immunity: EN61000-6-2; Certification: CE Marked
Compatibility:
Insulation Resistance: > 100 MΩ @ 50 VDC
Response time 10-90 %: 1 mS
Titanium alloy (1/4” BSP male (G1/4) and 1/4” NPT male thread); other thread options typically Titanium alloy/316L stainless
Wetted Parts:
steel
All fluids compatible with Titanium alloy (1/4” BSP male (G1/4) and 1/4” NPT male); other threads typically Titanium
Pressure Media:
alloy/316L stainless steel
Pressure Connection: 1/4” BSP male (G1/4); 1/4” NPT male; 1/2” BSP male (G1/2); 1/2” NPT male and 1/4” BSP female (others options available)
Electrical Connection: Mating socket EN175301-803 Form A (ex DIN43650) rated IP65 with PG9 cable entry (other options available)
Order Matrix
Electrical
Output Wires Type Connection/ Pressure Range Process Connection
Options
4-20 mA 2 GS4200
10 mV/V 4 GS4201
4 GS4202
0-5 V
3 GS4212
4 GS4203
0-10 V
3 GS4213
Electrical Connection/Options
DIN EN175301 plug and socket -
Cable outlet 1m screened A
M12 connector B
Cable outlet 1m screened IP67 protection C
ATEX/ IECEx certified with DIN EN175301 plug and socket EX
DNV GL Approval M
DNV GL Approval plus ATEX/IECEx certified MEX
Process Connection
1/4” BSP male (G1/4) AB
1/2” BSP male (G1/2) AC
1/4” NPT male AM
1/2” NPT male AN
DISCLAIMER : ESI Technology Ltd operates a policy of continuous product development. We reserve the right to change specification without
prior notice.All products manufactured by ESI Technology Ltd are calibrated using precision calibration equipment, traceable to national
measurement standards.