Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

DP

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

HPT700 series

Standard Industry
Differential Pressure Transducers
Applications
·Process Controls
·Tank Level Measurement
·Filter Performance Monitoring
·Corrosive Fluids and Gas Measurement Systems
·Flow Measurement with Pitot Tubes
·Orifice Plates and Mass Flow Meters
·Static Pressure Measurement and Control
·Combustion Chambers and Clean Rooms

Characters
·Precision Micro-Machined Silicon Core
·Explosion Proof and Non-Incendive Available
·High Stability, Low Drift
·316 Welded Stainless Steel Construction
·Premium Temperature Performance
·Broad Compensated Temperature Range
·Durable, 1 Million Cycle Life
·Ruggedness with Secondary Containment

Profiles
HPT700 series Differential pressure transducers can measure Measuring range
the differential pressure of liquids or gases ,wide range of
general purpose and industrial applications.Get all the great Measuring range
performance characteristics of the Micro-Machined Silicon
bar 0.1 to 0.5.. 0.5 to 1… 1 to 10
Transducers in these 316 stainless steel differential pressure
models . It utilizes a double diaphragm sensor technology that Kpa 10 to 50.. 50 to 100…100 to 1000
outperforms standard double sensor products in accuracy, psi 1.5 to 7.. 7 to 15 … 15 to 150
reliability and static operating pressure. mbar 0.01 to 0.05.. 0.05 to 0.1… 0.1 to 1
They give measuring range are also available in Mpa ,
This differential pressure sensing technology offers 0.25% Pa,in Hg,mm Hg
accuracy with static operating pressures up to 4MPa. With its
digital compensation, the HPT700 DP offers excellent linearity
and performance over temperature,long, reliable service life Materials
with excellent long term stability. Customers can choose from Wetted Parts Standard Option
multiple accuracy, outputs, pressure ports, electrical termina-
tions and pressure ranges. Case and sensor Stainless steel 316 316L SST/SUS321

Filled Oil Silicone oil Fluorocarbon oil


Holykell can provide a cost effective solution for pressure mo-
nitoring for a variety of applications. Welcome to your inquiry. Cable PVC PTFE/PUR/PE

01
Specifications

Ambient Temperature: 25°C (unless specified)

Parameter HPT700
Pressure Range 10~50KPa 51~100KPa 101~200KPa 201~1000KPa
High port overload 50~500 kPa 500~1000 KPa 10~20 Bar 20~40Bar
Low port overload 30~150KPa 150~300KPa 300~600KPa 600~1000KPa
Max Static Pressure 1~5 Bar 50~20KPa 20~40KPa 40~50KPa
Accuracy ≤±0.25%F.S (by customized);
(Linearity Hysteresis ≤±0.5%F.S (Typical);
Repeat ability) ≤ ±1.0%F.S Optional
Stability Standard: 0.1%F.S, Max:0.2%F.S
Ambient Temp Span -20℃~70℃
Medium Temp Span -30℃~85℃ / -20℃~125℃(with cool device)
Storage Temp -40℃~125℃
Temp Compensation -0℃~50℃ or -0℃~80℃ or by customized
Zero temp drift 0.02%F.S/℃
Sensitivity Temperature
Drift Compensation 0.02%F.S/℃
Medium compatible Compatible with 316 Stainless Steel
Electronic Wire 2 Wires 3 Wires 4 Wires
4~20mA 0~5V 0~10 V Rs485 MODBUS
Output analog signal analog signal analog signal (digital signal)
12~30Vdc 10~30Vdc 15~30Vdc 10-30Vdc
Power Supply (Typical:24 V DC) (Typical:24 V DC) (Typical:24 V DC) (Typical:24 V DC)

Load resistance (U-10)/0.02(Ω ) >100kΩ Max 255


Insulate resistance >100M Ω @100V
Fixed cable and water proof IP67 (HPT700-S);
Electronic connection
Terminal Box DIN43650 IP65 (HPT700-H,HPT700-G)
Pressure 1/4’’-18NPT Female; G1/4’’ Male; G1/2’’ Male;
connect port RG=Ø8/ Ø 10gas mouth optional. (by Customized)

Process structure All-Welded Construction (non-O-rings)


Response time ≤10ms
Pressure Type Differential Pressure (Gauge Type)
Certificate approving ExiaIICT6 and CE Certificate.
EN 61326-1:2013; EN 61326-2-3:2013
EMC Standard
EN 61000-6-2:2005; EN61000-6-4:2007+A1
Water Proof IP65 to IP68 optional by model
Weight Net weight is about 0.4KG, Full Packing weight is about 0.7KG (Included 3 Meters Cable)

02
Dimensions and Drawing

Unit: mm

Electronic Connections

DIN 43650 Connector


1 Vcc+
2 S+
Current 3 NC
4 Shield
1 Vcc+
2 GND
Voltage
3 S+
4 Shield

Directly sealed cable


Red Vcc+
Current Green S+

Black Shield
Red Vcc+
Voltage
Green GND
Yellow S+
Black Ground&Shield

S=Signal, Vcc=Power Supply, GND=Vcc-&S-

03
How to Order
1.Pressure Range Selection Table:

01 0~0.15 02 0~0.2 03 0~0.35 04 0~0.7 05 0~1 06 0~1.5 07 0~2 08 0~2.5

09 0~3 10 0~3.5 11 0~5 12 0~10 13 0~100 14 0~200 15 0~300 16 0~400

17 0~600 18 0~800 19 0~1000 X By Customized

Kindly according to your application select suitable range code , Example: Code 09 =3 .
Unit of measure select on the Part Number Selection Table . Example: Code B=Bar , that’s 3 bar .

2.Part Number Selection Table:

HPT700 H 9 B E5 10 S3 P1 1 002
Selection Type

H= Hirchman DIN43650
Electronic S= Directly Outlet Cable
Connection G= LED digital display

Pressure Range reference to pressure


Measurment range selection table code

B= Bar P=PSI K=kPa


Pressure Unit M=MPA H=mH2O

E5= 4-20mA(2 wires)


E6= 0-5V (3 wires)
Output
E7= 0-10V (3 wires)
E11= RS485 MODBUS RTU (4 wires)
E14= 4-20mA +Hart (2 wire)

3= 1/4’’ NPT male 7=G1/4"Female


Pressure 8= M20x1.5 male
connection 9=G1/2’’ male 10 =1/2’’ NPT male
26= 1/4’’-18NPT Female 27= RG=Ø10 gas mouth
X= By Customized

S3=24 V DC (Standard)
S5=12 V DC or 12V dc battery
Power Supply S17=10~30 V DC (for RS485)
S9=15~30V DC (for E7)
S10=12~30V DC (for E5 ,E6)

P1 Standard by DP Range
Max Static P2 High Static Pressure Type
Pressure X By Customized

Accuracy 1=1%F.S. 2=0.5%F.S 3=0.25%F.S (high cost)


Cable length 0=Non-Cable 001= Cable 1M 002= Cable 2M x= By Customized

04
Accessories

Description Order number


Liquid level display control device
with all kinds of liquid level sensor, measurement according to liquid level,
and according to the setting of the container structure and size and the 0008
density of liquid, calculation, display liquid volume or quality

NPT adapter
The 316 SS G1/2 adapter replaces the removable protective cap and 0001
converts the threads to 1/2”NPT male external, 1/4” female internal
threads.

Attached indicator for transmitters 0006


Standard version for Ex version

Adapter Converter
It is able to convert RS-232 signal to RS-485 balanced differential signal
and extend the communication distance to 1.2km.It uses a particular pump 0005
to gain power from RS-232 signal (RTS, DTR, TXD) without initializing the
RS-232 series interface.This interface converter does this without
requiring any AC or DC power.

Terminal box
The terminal box, with IP 67 ingress protection and watertight ventilation
element, provides a moisture-free electrical termination for the submersible 0003
pressure transmitter. It should be mounted in dry environment or directly in
the switch cabinet.

Order information
Model /Measuring range /Output Signal/Medium/Cable length/Case/Accessories

05

You might also like