Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Psa30 e

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Pressure Measurements and Monitoring

PSA30
Electronic Pressure Switch and Transmitter

• up to 2 switch points

• analogue output 4...20 mA or 0...10 V

• rotatable 320° display and electrical connection

• menu navigation refers to VDMA standard

• IO-Link communication interface

• measuring range 0...-1 bar up to 0...600 bar relative pressure

• max. temperature: 100 °C

Description: Typical applications:


The ceramic or piezoresistive measuring cells used in the The pressure sensor is suitable for almost all liquid and
PSA30 guarantee resistant pressure measurement combined gaseous media and is used in vacuum technology (pump
with high precision and a long service life. control), gas technology (supply monitoring, leakage
The integrated LED display is used for continuous pressure detection), filter monitoring (contamination detection) and for a
indication and, together with the programming buttons, allows wide variety of measuring tasks in hydraulics and pneumatics,
easy adjustment of the pressure sensor. Due to the rotatable in machine, apparatus and plant construction, in process
display and the rotatable pressure connection, there are engineering and building technology.
almost no restrictions for mounting. Various combinations are
available as output signals, up to 2 switching outputs, various
analogue outputs and IO-Link are possible.

20220321
PKP Prozessmesstechnik GmbH S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50 Subject to
technical
Borsigstr. 24 • D-65205 Wiesbaden info@pkp.de • www.pkp.de changes
Technical Data: Interfaces:
Sensor element: ceramic sensor
optional: piezoresistive sensor Communication
Materials: interface: IO-Link
Wetted parts: Stainless steel 1.4301, brass MS58* Transmission type: COM2 (38,4 kBaud)
Electronics housing: Stainless steel V2A, PA / PC
Seals: FKM, EPDM IO-Link revision: 1.1
Operating elements: 3 easy-response pushbuttons SCDI standard: IEC 61131-9
System of protection: IP65, IP67 Profile: Smart Sensor
Protection class: III SIO mode: yes
Electrical connection: Plug M12 x 1, 4-pin / 5-pin Device type: Class A
(depending on output code)
Process data variable: 1
Process connection: see order code
Binary data channel: 2
Dimensions: 110 x 41 mm (without plug
Min. process cycle time: 2,5 ms
connector)
Device ID: 0x011...
Weight: ca. 200 g
EMV / ESD: EN 61000-4-2 4 kV CD / 8 kV
A/D converter:
ESD AD
Resolution: 12 bit
(4096 steps per measuring span) EN 61000-4-3 10 V/m
Scanning rate: 1000 / s HF radiated
Linearity error: < ± 0,5 % v. f. s. at +25 °C EN 61000-4-4 2 kV
Burst
Temperature influence: TC zero < ±0,2 % FSO / 10K
TC span < ±0,3 % FSO / 10K EN 61000-4-5- 1/2 kV
Surge
Compensation range: -10 °C... +70 °C

Pressure
EN 61000-4-6 10 V
Repeatability: ± 0,1 % FSO
HF, conducted
Temperature range:
Shock resistance DIN EN 60028- 50 g (11 ms)
Medium: -25 °C... +100 °C
2-27
Electronics: -10 °C... +70 °C 1)
Storage: -30 °C... +80 °C Vibrations resistance DIN EN 60028- 20 g
2-26 (10...2000 Hz)
Power supply: 15... 32 VDC, reversed polarity
protected (SELV, PELV) Approvals: BV-50018/A0 2),3), cULus 1) -
E42816
Digital display: 4-digit 14-segment LED display,
red, digit height 9 mm
* In the pressure inlet a damping screw made of brass is
Error display: LED red and alphanumeric display mounted. This screw can be removed if required, e.g. in case of
Power consumption: approx. 50 mA (without load) soiled medium or material incompatibility, using a slotted screw
driver (max. width 3 mm).
Analogue output: The pressure switch is less resistant to pressure peaks when the
Current output: 4...20 mA damping screw has been removed.
Load: max. RI = (Ub-12V) / 20 mA 1)
Conditions of use with cULus: 60 °C max. ambient, power
RI = 600 Ohm bei Ub = 24 VDC supply max. 28 VDC
Scanning rate: 2 ms 2)
BV approval only with output code 1-5
Voltage output: 0...10 VDC 3)
Direct electromagnetic fields can interfere the LED display, at
Rating: max. 10 mA some frequencies. This does not lead to an impairment of the
Adjustment range: 25 %...100 % f. s. performance.

Transistor switching outputs / IO-Link:


Switching function: Normally open/normally closed,
standard / window mode and
diagnosis function adjustable
Adjustment range switch.
point and hysteresis: 0 %... 125 % f. s.
Switching frequency: max. 100 Hz
Load: max. 500 mA, short-circuit
proof, IO-Link: max. 250 mA
Delay: 0.0 s ... 50 s adjustable
Status display(s): LED(s) red

PKP Prozessmesstechnik GmbH S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
Borsigstr. 24 • D-65205 Wiesbaden info@pkp.de • www.pkp.de
Dimensions: Process connections:

G G 1/4" Ceramic
N 1/4" NPT Ceramic
2 G 1/2" flush diaphragm
3 1/2" NPT flush diaphragm
E 7/16-20 UNF (SAE)
P 7/16-20 UNF (JIC)

PKP Prozessmesstechnik GmbH S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
Borsigstr. 24 • D-65205 Wiesbaden info@pkp.de • www.pkp.de
Electrical Connection: Order Code:
BPS3000
Order number: PSA30.BPS3 1 G V M 0010B -

Electronic pressure switch and


transmitter
Output:
1 = 2 switch points
2 = 4…20 mA and 1 switch point
3 = 0…10 V and 1 switch point
4 = 4…20 mA and 2 switch points
5 = 0…10 V and 2 switch points
7 = IO-Link / 2 switch points (PNP, NPN, PP)
8 = IO-Link / 2 switch points (PNP, NPN, PP)
/ analogue output

Pin Signal Output Signal Output Signal Output Process Connection:


Code 1, 7 Code 2, 3 Code 4, 5, 8 G = G 1/4 male thread
2 = G 1/2 flush diaphragm (requires piezores.
1 +Ub +Ub +Ub sensor / Code P* / 10-600 bar only)
N = 1/4" NPT male thread
2 SP2 Signal Signal
3 = 1/2" NPT flush diaphragm (requires piezo-
3 0V 0V 0V res. sensor / Code P* / 10-600 bar only)
1 = 40x40 Cetop/Manifold – on request
4 SP1 / IO-Link* SP1 SP1 / IO-Link* E = 7/16-20 UNF (SAE4) male
P = 7/16-20 UNF (37° JIC) male
5 - - SP2
Sealing:
V = FKM
E = EPDM
Electrical Connection:
M = M12 plug
Measuring range:
-1.0BV = -1...0 bar (requires pieszor. sensor P*), IP65 only
0001BV = -1...1 bar (requires pieszor. sensor P*), IP65 only
0005BV = -1...5 bar (requires pieszor. sensor P*), IP65 only
0010BV = -1...10 bar (requires pieszor. sensor P*), nur IP65
0001BA = 0...1 bar absolute (requires pieszor. sensor P*)
0005BA = 0...5 bar absolute (requires pieszor. sensor P*)
0010BA = 0...10 bar absolute (requires pieszor. sensor P*)
00.2B = 0...0,2 bar (requires pieszor. sensor P*), IP65 only
00.5B = 0...0,5 bar (requires pieszor. sensor P*), IP65 only
0001B = 0...1 bar (requires pieszor. sensor P*), IP65 only
0002B = 0...2 bar (requires pieszor. sensor P*), IP65 only
0005B = 0...5 bar (requires pieszor. sensor P*), IP65 only
0010B = 0…10 bar
0050B = 0…50 bar
0100B = 0…100 bar
0200B = 0…200 bar
0400B = 0…400 bar
0600B = 0...600 bar (requires pieszor. sensor P*)
others on request
Sensor:
- = ceramic (standard)
P = *piezoresistive sensor

Accessories:

Plug connector M12 x 1, 4-pin, with screw terminals, angled


(IP65)
Plug connector M12 x 1, 5-pin, with screw terminals, angled
(IP65)
Plug connector M12 x 1, 5-pin, with sharped cable (IP67)

PKP Prozessmesstechnik GmbH S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
Borsigstr. 24 • D-65205 Wiesbaden info@pkp.de • www.pkp.de