Digital Control Unit For Thermal Solar Systems: Description
Digital Control Unit For Thermal Solar Systems: Description
Digital Control Unit For Thermal Solar Systems: Description
Description
The digital control unit S303 is a centralized control unit for
thermal solar panels. Equipped with 3 relay outputs (2 for loads
+ 1 for alarm), PWM output, 0..10V output and 3 inputs (sensors),
can configure and manage up to 6 different types of solar
systems. When a specific installation is selected, the control unit
automatically manages the outputs and inputs used to control
the valves, the pumps, the integrative sources and the probes
used in the type of installation selected.
Moreover on the backlit LCD display it is possible to visualize
the hydraulic diagram of the installation set up, the state
of the outputs, the probes as well as several other data and
informations. Control unit supplied with 2 NTC probes.
Technical features
Power supply: 230V~ ±10% 50Hz
Power absorption: <2 VA
Sensors type: 3 x NTC 10K @ 25 °C ±1 %
Sensor operating range: -50 °C .. +200 °C (collector)
-50 °C .. +110 °C (boiler)
Temperature reading range: -20 °C .. 180 °C
Accuracy: ±2 °C
Resolution: 0,1°C (-20°C .. 144,9°C)
1°C (145°C .. 180°C)
Offset adjustment: on S1: ±5.0°C
on S2: ±5.0°C
on S3: ±5.0°C
Installer Password: 0000 .. 9999 (default 0000)
Acoustic Signal: On/Off (default On)
Backlight timing: 20 sec from last keypress
OUT2 Relay Logic: NOR=N.O. REV=N.C.
(default N.O.)
Contacts rating:
OUT 1 relay: 2(1)A max 250V~ (SPST)
Voltage free
OUT 2 relay: 8(1)A max 250V~(SPST)
Voltage free
Alarm relay contacts rating: 4(1)A max 250V~ (SPDT)
Voltage free
Output Signal:
PWM: Amplitude: 10V ±15%
Frequency: 1KHz
Current: 15mA max.
0..10V: Amplitude: 0V..10V ±10%@10V
Minimum load: 10KOhm.
Max allowed PWM / 0...10V cable length: < 3m.
Dimensions
SELECTION KEYS
RESET KEY MENU KEY CANCEL KEY KEY ‘ABC FUNCTION’ CONFIRMATION KEY
WARNING!
The installation technician shall operate in full compliance with all the applicable technical standards in order to
grant the unit safety.
Electrical connections
: reinforced
isolamento rinforzato
insulation
ATTENZIONE!
WARNING!
Prima di effettuare qualsiasi collegamento accertarsi che la rete elettrica sia scollegata.
Before wiring the appliance be sure to turn the mains power off.
ATTENZIONE! S1, S2, S3 sono sensori di temperatura NTC. Per il sensore S1 si deve usare una sonda con range -50°C..+200°C
WARNING! S1, S2 and S3 are NTC temperature sensors. For S1 sensor the -50°C..+200°C range probe (blue cable) must
(sonda fornita con cavo blu), mentre per le altre sonde si possono usare le sonde con range -50°C..+110°C (sonde fornite con
be used, while the probes with the range of -50°C..+110°C (yellow cable) can be used for the other probes.
cavo giallo). Le uscite OUT1, OUT2 e di allarme, sono libere da tensione. E’ consigliabile inserire sulla linea di alimentazione della
The outputs OUT1, OUT2 and Alarm, are voltage free. It is advisable to fit a 10A 250V~ fuse on the power unit mains
centralina un fusibile da 10A 250V~, che interviene in caso di cortocircuiti sui carichi.
capable to intervene in case of short circuits on loads.
MORSETTIERA DI TERRA: Sulla base della centralina è presente una morsettiera in ottone per collegare i conduttori di
TERMINAL BOARD
protezione GROUNDING:
di terra On connessi
dei vari dispositivi the basealla
ofcentralina.
the control unit case is located a brass terminal board for connecting
the ground protection conductors of the load devices connected to the control unit.
ESEMPIO DI COLLEGAMENTO SOLO PER CIRCOLATORI CONFORMI ALLA DIRETTIVA ErP 2015, CON
SEGNALE PWM ESTERNO.
Icma SpA - Via Garavaglia, 4 Tel: +39 02 97249134 - +39 02 97249135
20012 Cuggiono (MI) ITALIA 3 www.icmaspa.it - sales@icmaspa.it
Digital control unit for thermal solar systems
S303 TECHNICAL DATA SHEET - 02/2022 - ENG
Available diagrams
SCH 01 SCH 04
Solar heating installation with 1 tank and no Solar heating installation with 1 tank, direct
integrative heat source. integration by means of valve logic.
SET SET
OUT 1
OUT 2
OUT 3
TM3
OUT 1
TAH TAH
TAF TS3
TAF TS3
TS2
TS2
SCH 02 SCH 05
Solar heating installation with 1 tank and Natural circulation solar heating installation with
additional thermostatic heating. 1 tank and direct integration by means of valve
logic.
SET SET
OUT 2
OUT 1
OUT 2
OUT 3
TAF TS3
TS2
SCH 03 SCH 06
Pool solar heating installation. Solar heating installation with 1 tank and only 2
probe.
SET SET
TAF TS3
TS2