A Quick Ref For Commandhandling
A Quick Ref For Commandhandling
report
Prepared Date Rev Document no.
eeiltn 1996-09-02 PA3 EEI/RGV-96:0054Uen
Approved Checked File/reference
eei/rgc Leo Theunissen
1 Introduction
2 Managed object handling
2.1 G12
2.2 Managed Object Specific Properties
2.3 Operation and Maintenance Communication
3 Subrate Swith
4 Radio Transmission Subsystem, RTS
4.1 Command descriptions
4.1.1 Device SW Unit handling (RRDSL/RRDSP/RRDSE)
4.1.2 TRA Pool handling (RRTPC/RRTPE/RRTPI/RRTPP)
4.1.3 TRA Pool Mean Hold Supervision handling (RRMSE/RRMSI/RRMSP)
4.1.4 TRA Pool Mean Hold Supervision Alarm Handling (RRMAP/RRMAR)
4.1.5 TRA Pool Idle Supervision Handling (RRISE/RRISI/RRISP)
4.1.6 Manual blocking/deblocking TRA devices (RRTBI/RRTBE)
4.1.7 Line level handling (RRLLC/RRLLP)
4.1.8 TRH LOAD (RA-HII/HDC/HDP/HHP/HTP/HPP/HLC/HAR/HEP)
4.2 RTS command parameter information
4.2.1 Comand parameter, alphabetical order
4.3 RTS Command Fault code information
4.4 RTS Printout Parameter Descriptions
5 Tranceiver Administration Subsystem, TAS
5.1 Command Descriptions
5.1.1 Definition of MO, commands RXMOI/E/P/C
5.1.2 Abis path handling , commands RXAPI/RXAPE/RXAPP
5.1.3 TG To Channel Group ,commands RXTCI/RXTCE/RXTCP
5.1.4 MO in service, commands RXESI/RXESE,
5.1.5 commands RXMSC, MO in service data
5.1.6 Status of MO, commands RXMSP
5.1.7 Capabilities of MO, RXCAP
5.1.8 commands RXBLI/RXBLE, Blocking of MO
5.1.9 commands RXPLI/RXPLE, FC & PL of MO
5.1.10 Test of MO, commands RXTEI/RXTEE,
5.1.11 BSC-BTS Loop Test, commands RXLTI
5.1.12 MO congiguration data print, commands RXCDP,
5.1.13 MO Error Log Print , commands RXELP/RXELR
5.1.14 MO Hopping Data Print, commands RXHDP
5.1.15 MO Hopping Frequency set extension measuring program, commands RXHMI/RXHMP/R
5.1.16 MO Device Information Print, commands RXMDP,
5.1.17 MO Fault Information Print, commands RXMFP,
5.1.18 Alarm Coordination Data , RXALC/RXALP/RXASP
5.2 TAS command parameter information
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 2 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 3 of 132
9.16.6 Commands RLSLI, RLSLC, RLSLP, RLSLE, Supervision of Logical Channels Availab
9.16.7 CELL CONNECTION OF CELL TO CHANNEL ALLOCATION , RLHPC/RLHPP
9.16.8 CELL IDLE CHANNEL MEASUREMENT CHANGE, RLIMC/RLIMI/RLIMP
9.16.9 CELL LOAD SHARING DATA , RLLCC/RLLCE/RLLCP
9.16.10 BSC LOAD SHARING DATA , RLLSI/RLLSE/RLLSP
9.16.11 CELL BSC BAND OPERATING MODE CHANGE, RLOMC/RLOMP
9.16.12 CELL BSC DIFF. CHANN. ALLOC. PRIO. PROFILE, RLLPPC/RLLPI/RLLPE
9.16.13 CELL BSC DIFF. CHANN. ALLOC. PRIO. TO RESOURCE TYPE , RLPRC/RLPRI/RLPRP
9.16.14 CELL BSC DIFF. CHANN. ALLOC. STATISTICS, RLSCE/RLSCE/RLSCP/RLDSP
9.17 RCS fault codes
9.17.1 Fault Codes in Numerical Order
10 Translation between the ABIS O&M IWD and BSC command parameters
10.1 BTS logical model G01
10.2 BTS Logical Model G12
1 Introduction
This document is ment as a quick reference when using the CMER6.1/BSC = APT210 09 R7 =
BSCR7
This document is NOT an official document and so will not be inspected and so some
mismatches, spelling mistakes etc.. could be expected
Command and printout information for the following Subsystems are covered by this
Document.:
This PA3 revision has the RTS commands,TAS co commands are not on R6.1 level yet.
Currently the RCS/ROS/LHS commads are on R6 level. This beaciuse the R5 lazy ref has to be
updated to R6 first in order to go to R6.1.
By end of august 1996 this document is expected to be completly updated for R6.1
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 4 of 132
2.1 G12
A managed object cannot perform any traffic function if it is not operational. Some objects
depend on other objects to be able to be operational, that is be automatically deblocked from
superior object. In the G12 TG the following relationships are valid:
TG (Superior)
| |
V |
CF |
| |
V |
+----+----+----+----+ |
V V V V V |
TRXC IS DP CON TF |
| |
V |
+---+---+ |
V V V |
RX TX TSs (Subordinate)
If a managed object is out of operation then its subordinate managed objects will also be taken
out of operation.
An application object must be configured to be used for its traffic function. Whether an
application object is configured or not is reflected by a configuration state.
A managed object can be defined, taken into service and manually deblocked.
The order for bringing managed object instances into service is TG first followed by CF before
its corresponding TRXCs, IS, DPs, TF and CON; and TRXC before its corresponding TX, RX
and TS. The manual deblocking will start the process of bringing a managed object into
operation. The managed object will then automatically be available to carry traffic.
Similarly, a managed object can be manually blocked to bring it out of operation, taken out of
service and removed. The order for taking managed object instances out of service is TX, TS
and RX before the corresponding TRXC;
TRXC, IS, CON, DP and TF before the corresponding CF; and CF before the corresponding
TG.
TG
The managed object TG cannot be communicated with over the Abis interface for operation
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 5 of 132
and maintenance. Thus, it cannot be tested, configured etc. However, if the managed object TG
is allowed in a command, it may refer to all managed objects within that TG. For example,
program load of a TG means program load of all managed objects belonging to that TG.
CF
The CF stores the software for itself the IS, DP and TF within the same TG.
TRXC
The TRXC stores the software files for itself and its dedicated RX, TX and TS.
TX, RX and TS
The TXs, RXs and TSs in a TG can be configured when they are operational. This
configuration makes the managed object possible to use for traffic purposes. In this case the
traffic purpose is to support the created basic physical channels.
If any TX, RX or TS cannot fulfill its assigned traffic function, the influenced logical channels
will be taken out of traffic. A managed object cannot fulfill its traffic function when it is out of
operation. However, a TS will not be able to fulfill its traffic functions, if the TF is not
synchronised or the radio signalling link is not working. A TS can support traffic channels and
signalling channels if the speech and data path is working. If the speech and data path is not
working then the TS can still support signalling channels. However, neither of these
circumstances will take the managed object TS itself out of operation.
IS
The IS is configured when operational in a similar way to the TXs, RX and TS however the IS
is not used directly for traffic functions. The IS is configured with data that sets up connections
between two DCPs. A connection is only considered made when the IS is enabled. Once
enabled connections will survive some fault situations and even a reset.
CON The CON is configured when operational in a simular way to the TX, RX and TS.
However, the CON is not used directly fro traffic functions . The CON is configured with data
thats sets up the internal connetctions between a concentrated path and it's associated un-
concentrated path, or paths.
A connection is only considered to have been made when the CON BTS state is ebnabled.
When a connection has been made, the CON BTS stae is set to disconnected in advance of any
future configurations.
CON connecions will survive some fault situations
DP
The DP is configured when operational in a similar way to the IS. The DP is configured with
data that specifies DIP Fault and Quality supervision of the associated PCM system. Data is
only allowed to be changed in BTS state disabled. Once enabled the supervision functions are
activated.
TF
The TF can be started with new software without losing synchronisation.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 6 of 132
All communication to and from the managed objects go through either a TRXC or the CF.
Each RX, TX and TS has a dedicated TRXC, through which its communication passes. The IS,
DP and TF are reached through the CF.
Communication is made with the CF and TRXC once these managed objects are brought into
service.
For the TRXC, the route through the IS will be made between the specified digital connection
point (DCP) described at definition of the TRXC and the specified DCP of any available abis
path.
For the CF, communication will be established automatically on any of the available abis paths.
+--------------------------+
| CF |
| |
+-+--------+-----+-----+----+
| | | |
| +-+-+ +-+-+ +-+-+
| |CON| |TF | |DP | -+
| +---+ +---+ +---+ | (2 DPs)
| +---+
|OML-C
+--|--+
OML-C | . | +-----+ +--+
--------.... | |TRXC +---+RX|
OML-TC | | OML-TC | | +--+
--------.......---------+ | +--+
| | | +---+TS++
| | | | ++-+| (8 TSs)
| | | | +--+
| IS | | | +--+
| | | +---+TX|
| | | | +--+
| | +-----+
| |
| | +-----+ +--+
| | |TRXC +---+RX|
OML-TC | | OML-TC | | +--+
--------.......---------+ | +--+
| | | +---+TS++
| | | | ++-+| (8 TSs)
| | | | +--+
| | | | +--+
| | | +---+TX|
| | | | +--+
| | +-----+
+-----+ .
.
(16 TRXCs)
TC = Transceiver Control
C = Common control
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 7 of 132
3 Subrate Swith
} - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~
! 0 }"""""""~ !
}"""""""~ }"""""""""""""\ }"""""#"~ }""""""""""""""""""""~
! SNT ! [""#"""""""""""""]"\ T S M ! ! }"""""""""""""""""#"""~ !
|"""""""{ . ! ! ["""""""""""\ ! S P M !
. ! . 15 ! ! ["""""""""""]""\ ! !
}"""""""~ }"""""""""""""\ ! ! ! ! !
! SNT ! [""#"""""""""""""]"\ ! ! ! ! !
|"""""""{ |"\ ! ! ! !
! |"""""""{ ! ! ! !
. ! ! !
! }"""""""~ ! ! ! !
}"""""""~ }"""""""""""""\ }"""""#"~ ! ! !
! SNT ! [""#"""""""""""""]"\ T S M ["""""""""""\ ! ! !
|"""""""{ ! ! ["""""""""""]""\ !
} - - - - - - { ! ! ! ! ! ! !
}"""""""~ ! ! ! ! ! !
! !}""""""#~ |"\ ! ! ! ! !
!!}""""""#~ |"""$"""{ ! ! !
! !!! C L M [""""""""""""""""""""""""""{ ! ! ! !
|\! [""""""""""""""""""""""""""""""""""""""""""\ ! !
! |\ [""""""""""""""""""""""""""~ ! ! ! !
|"""""""{ }"""""#""""~ ! ! !
! ! }""""""""#"~ ! ! ! !
}""""""""""""""""~ ! ! TSM ! ! ! !
! !}"""""""""""""""#~ 0 ! ! WITH [""""""""\ ! ! !
!! S R S M ["""""""""\ ! PARALLEL [""""""""]""\ !
! !! ["""$"""""]"\ INTER- ! ! ! ! !
!! ! ! |"\ FACE ! ! ! !
! !! ! ! |""""""""""{ ! ! ! !
!! !Each . ! ! !
! !! !Interface . ! ! ! !
!! !has 512 }""""""""""~ ! ! !
! !! !TimeSlots! }""""""""#"~ ! ! ! !
!! ! ! ! ! TSM ! ! ! !
! !! ! ! 7 ! ! WITH [""""""""\ ! ! !
!! ["""#"""""\ ! PARALLEL [""""""""]""\ !
! !! ["""""""""]"\ INTER- ! ! ! ! !
|\ ! |"\ FACE ! ! ! !
! |""""$"$"""$"$"""{ |$"$"$"$"""{ |""\ ! !
|"\ |"\ |"\ |"\ |"""""""""""""""""""""{
| - - - - - \ - - \ - - - - - - - - \ - \ - - - - - - - - - - - - - - - - - - - - -{
}"#"""""]""~ }"""#"""]""~ G S S
! }"""""#""#"~ ! }"""""#""#"~
! ! R P ! ! ! R P !
|"\ ! |"\ !
|""""""""""{ |""""""""""{
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 8 of 132
+ +
| SUID=suid | + +
RRDSL:SNT=snt..., + + |,UC| ;
| SUNAME=suname | + +
+ +
RRDSP:SNT=snt...;
END
+ +
| snt... |
RRDSE:SNT=+ + ;
| ALL |
+ +
CHANGE
+ +
RRTPC:TRAPOOL=trapool,RNOTRA=rnotra ... |,FORCE | ;
+ +
END
RRTPE:TRAPOOL=trapool;
INITIATE
RRTPI:TRAPOOL=trapool, CHRATE=chrate,SPV=spv;
PRINT
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 9 of 132
| ALL... | + +
RRTPP:TRAPOOL=+ + |,FORCE | ;
| trapool... | + +
+ +
END
+ +
| ALL... |
RRMSE:TRAPOOL=+ + ;
| trapool... |
+ +
INITIATE
+ + + +
| ALL... | | A1 | + +
RRMSI:TRAPOOL=+ + , ACL= + A2 + |,MHTLIM=mhtlim | ;
| trapool... | | A3 | + +
+ + + +
PRINT
+ +
| ALL... |
RRMSP:TRAPOOL=+ + ;
| trapool... |
+ +
PRINT
+ +
| ALL... |
RRMAP:TRAPOOL=+ + ;
| trapool... |
+ +
REMOVE
+ +
| ALL... |
RRMAR:TRAPOOL=+ + ;
| trapool... |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 10 of 132
END
+ +
| ALL... |
RRISE:TRAPOOL=+ + ;
| trapool... |
+ +
INITIATE
+ + + +
| ALL... | | A1 | + + + +
RRISI:TRAPOOL=+ + , ACL= + + |,LIM1= lim1 | |,LIM2= lim2 | ;
| trapool... | | A3 | + + + +
+ + + +
PRINT
+ +
| ALL... |
RRISP:TRAPOOL=+ + ;
| trapool... |
+ +
BLOCKING
+ +
RRTBI:DEV=dev... |,FORCE |;
+ +
DEBLOCKING
RXTBE:DEV=dev...;
+ +
|+ ++ +|
||+ +|| + +||
|||ULP=ulp||| |DLP=dlp|||
RRLLC:+|+ +||,+ +|+;
|||ULN=uln||| |DLN=dln|||
||+ +|| + +||
|+ ++ +|
+ +
RRLLP;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 11 of 132
RAHII;
+
| + + + +
RAHDC: + |,CAPHYST=caphyst| |,CAPLIM= caplim |
| + +
+
+
+ + + + |
|,INTERVAL= interval | |,STIME= stime | +
+ + + + |
+
RAHDP;
+ +
| snt... |
RAHHP:SNT=+ + ;
| ALL | ,HIGH| |
+ +
+ +
| snt... |
RAHTP:SNT=+ + ;
| ALL |
+ +
RAHHP;
RAHLP;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 12 of 132
| + + +
+
+
+ + |
|, TRHLIM= trhlim | + ;
+ + |
+
RAHAR;
+ +
RAHEP + :NOINT =noint +;
+ +
4.2.1.2 DEV
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 13 of 132
4.2.1.5 FORCE
LIM1=lim1 Limit 1
Percent: 1 -99
Alarm limit for idle transcoder resources in the
transcoder pool, in percent of actual number of transcoder
resourses for the transcoder pool. The lower and less
severe limit.
LIM2=lim2 Limit 2
Percent: 1 -99
Alarm limit for idle transcoder resources in the
transcoder pool, in percent of actual number of transcoder
resourses for the transcoder pool. The lower and more
severe limit.
PRINTDEV printdevices
Specifies that the devices belonging to the
transcoder pools are printed
RNOTRA=rnotra Integer
The required number of transcoder
resources in the transcoder pool
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 14 of 132
4.2.1.15 UC - Unconditional
Paramter given is dB
Numeral 0 - 12
Default value: refer to application
information for RTTRC
Paramter given is dB
Numeral 0 - 12
Default value: refer to application
information for RTTRC
FAULT CODE 1
TRANSCODER POOL ALREADY EXISTS
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 15 of 132
FAULT CODE 2
TRANSCODER POOL WITH SPECIFIED CHANNEL SERVICE ALREADY EXISTS
FAULT CODE 3
TOO MANY ARGUMENTS
FAULT CODE 4
TRANSCODER POOL WITH SPECIFIED CHANNEL SERVICE IS NOT SUPPORTED
FAULT CODE 5
TRANSCODER POOL DOES NOT EXIST
FAULT CODE 6
TRANSCODER POOL IDLE LEVEL SUPERVISION IS CONNECTED
FAULT CODE 7
TRANSCODER POOL MEAN HOLD TIME SUPERVISION IS CONNECTED
FAULT CODE 8
TRANSCODER RESOURCES ARE ASSIGNED TO POOL
FAULT CODE 9
TRANSCODER POOL ALREADY CONNECTED TO IDLE LEVEL SUPERVISION
FAULT CODE 10
TRANSCODER POOL IDLE LEVEL SUPERVISION IS NOT CONNECTED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 16 of 132
FAULT CODE 11
INCORRECT LIMITS SPECIFIED
FAULT CODE 12
TRANSCODER POOL ALREADY CONNECTED TO MEAN HOLD TIME SUPERVISION
FAULT CODE 13
TRANSCODER POOL MEAN HOLD TIME SUPERVISION IS NOT CONNECTED
FAULT CODE 14
PROGRAM LOAD IN PROGRESS
FAULT CODE 15
UNSUPPORTED SNT TYPE
FAULT CODE 16
MAXIMUM NUMBER OF TRANSCODER RESOURCE INDIVIDUALS IS USED
FAULT CODE 17
DSU NOT TIED
FAULT CODE 18
DSU NAME NOT UNIQUE
FAULT CODE 19
NOT EXISTENT DSU
FAULT CODE 20
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 17 of 132
FAULT CODE 21
SNT IS NOT BLOCKED
FAULT CODE 22
TOO MANY SNTS SPECIFIED
FAULT CODE 23
SNT NOT FULLY CONNECTED
FAULT CODE 24
SNT SPECIFIED TWICE IN COMMAND
FAULT CODE 25
CP-PS NOT AVAILABLE
FAULT CODE 26
LOADING NOT ORDERED
FAULT CODE 27
INCORRECT DSU TYPE FOR THIS SNT OWNER
FAULT CODE 28
TRANSCODER POOL CHANGE IN PROGRESS
FAULT CODE 29
LOADING NOT ORDERED FOR SPECIFIED SNT
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 18 of 132
FAULT CODE 30
TRANSCODER POOL NAME SPECIFIED MORE THAN ONCE
FAULT CODE 50
CANNOT MIX DIFFERENT TRANSCODER DEVICE TYPES
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 19 of 132
lim1 Limit 1.
Alarm limit for idle transcoder resources
in the transcoder pool, in percent of actual
number of transcoder resources for the
transcoder pool. The less severe limit.
lim2 Limit 2.
Alarm limit for idle transcoder resources
in the transcoder pool, in percent of actual
number of transcoder resources for the
transcoder pool. The more severe limit.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 20 of 132
connection resulted in
fault.
ERROR ON COMPLETE TRAB
Error on complete TRAB
reported.
TRAB NOT RESPONDING
TRAB not alive, TRAB not
responding.
GS CLOCK SUPERVISION ERROR
GS clock supervision error
reported.
TRA CHANNEL FAULT
TRA channel fault reported.
CONTROLLING EM FAILURE
Loading not successful.
Failure in controlling
EM.
DEVICE BUSY
The specified device belongs
to a transcoder pool.
Specify again using the
FORCE parameter.
DP NOT LOADABLE
Loading not successful.
The device processor is
not of a loadable type.
LOADING ABORTED
Loading not successful.
Loading has been
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 21 of 132
cancelled by
the operator.
LOADING SUCCESSFUL
The device processor
associated with the SNT
has been loaded
successfully.
NO DP CONTACT
Loading not successful.
Controlling EM has no
contact with device
processor.
NO PROGRAM LOADED
The information has
not been fetched
successfully. The device
processor associated
with the SNT has not
been program loaded.
SUCCESSFUL
The information has
been fetched
successfully.
TIMEOUT
Loading not successful.
Time limit for
signalling with
controlling EM
exceeded.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 22 of 132
Paramter given is dB
Numeral 0 - 12
Default value: refer to application
information for RTTRC
Paramter given is dB
Numeral 0 - 12
Default value: refer to application
information for RTTRC
INITIATE
E.g. RXMOI:MO=RXOTG-100,COMB=HYB,RSITE=RSITE2,SWVER=BSG12R2,TRACO=POOL;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 23 of 132
E.g. RXMOI:MO=RXOTRX-101-0,TEI=4,DCP1=128,DCP2=129&130;
E.g. RXMOI:MO=RXOCF-100,TEI=62,SIG=MPLEX32;
RXMOI:MO=mo...,TEI=tei;
E.g.RXMOI:MO=RXOIS-100;
RXMOI:MO=mo...,TFMODE=tfmode;
RXMOI:MO=RXOTF-100,TFMODE=SA;
+ +
|DCS| + +
RXMOI:MO=mo...,BAND=+ +,MPWR=mpwr|,ANT=ant|;
|GSM| + +
+ +
Managed object RX(Both Logical models)
+ +
|AB| + +
| | |DCS |+ ++ +
RXMOI:MO=mo...,RXD=+A +,BAND=+ +|,ANTA=anta||,ANTB=antb|;
| | |GSM |+ ++ +
|B | + +
+ +
RXMOI:MO=mo...;
RXMOI:MO=mo..,DEV=dev;
E.g RXMOI:MO=RXODP-1-0,DEV=RXODPI-2;
RXMOI:MO=mo..,DCP=dcp;
E.g RXMOI:MO=RXOCON-1,DCP=64&&87;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 24 of 132
CHANGE
+
|+ + + +
|| + +| | + +|
|| |BB||+ +| |HYB||
RXMOC:MO=mo...+|,FHOP=+ +||,SWVER=swver||,COMB=+ +|
|| |SY||+ +| |FLT||
|| + +| | + +|
|+ + + +
+
+
|
+ ++ +|
|,RSITE=rsite||,EMG=emg|+;
+ ++ +|
|
+
+ + + + + +
|,RSITE=rsite| |,TRACO=traco| |,CONFACT=confact| ;
+ + + + + +
+
|
+ + |
|,HFSEXT=hfsext| ; + ;
+ + |
|
+
+
|+ ++ +
|| + +|| + +|
|| |cell||| |DEFAULT||+ +
RXMOC:MO=mo+|,CELL=+ +||,SWVER=+ +||,TEI=tei|
|| |ALL ||| |swver ||+ +
|| + +|| + +|
|+ ++ +
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 25 of 132
+
+ +|
|+ +||
+ ++ +||,DEV2=dev2...|||
|,CTEI=ctei||,DEV1=dev1||+ +|+;
+ ++ +||,NOTRAFF |||
|+ +||
+ +|
+
+
|+ ++ +
|| + +|| + +|
|| |cell||| |DEFAULT||+ +
RXMOC:MO=mo+|,CELL=+ +||,SWVER=+ +||,TEI=tei|
|| |ALL ||| |swver ||+ +
|| + +|| + +|
|+ ++ +
+
+
+ +|
|+ +||
+ +||,DCP2=dcp2...|||
|,DCP1=dcp1||+ +|+;
+ +||,NOTRAFF |||
|+ +||
+ +|
+
+ +
| + + |
| | | |
| | | |
| | |DEFAULT|| + + + + |
RXMOC:MO=mo...+ |,SWVER=+ +| |,SIG=sig| |,SIG=sig| + ;
| | |swver || + + + + |
| | + +| |
| | | |
| + + |
+ +
RXMOC:MO=mo...,TFMODE=tfmode;
+
|+ + + +
|| + +| | + +|
|| |cell||+ +| |DCS||
RXMOC:MO=mo...+|,CELL=+ +||,ANT=ant||,BAND=+ +|
|| |ALL ||+ +| |GSM||
|| + +| | + +|
|+ + + +
+
+
|
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 26 of 132
+ +|
|,MPWR=mpwr|+;
+ +|
|
+
+
|+ +
|| + +|
|| |AB||
|| | ||+ ++ +
RXMOC:MO=mo...+|,RXD=+A +||,ANTA=anta||,ANTB=antb|
|| | ||+ ++ +
|| |B ||
|| + +|
|+ +
+
+
+ +|
| + +||
| |DCS|||
|,BAND=+ +|+;
| |GSM|||
| + +||
+ +|
+
+ +
|MO=mo... |
RXMOP:+ +;
|MOTY=moty|
+ +
RXMOE:MO=mo...;
RXAPI:MO=mo,DEV=dev...,DCP=dcp...;
+ +
| dcp...|
RXAPE:MO=mo,DCP= + + ;
| ALL |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 27 of 132
+ +
|MOTY=moty|
RXAPP:+ +;
|MO=mo... |
+ +
RXTCI:MO=mo,CELL=cell,CHGR=chgr...;
RXTCE:MO=mo,CELL=cell,CHGR=chgr...;
+ +
| + +|
|MOTY=moty|,CELL=cell||
| + +|
RXTCP:+ +;
| |
|MO=mo... |
| |
+ +
RXESI:MO=mo...;
RXESE:MO=mo...;
Managed Object TG
+ +
| + + + + + + |
RXMSC:MO=mo...| |,SWVER=swver | |,CONFACT=confact | |, HFSEXT=hfsext | |;
| + + + + + + |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 28 of 132
|DEFAULT|
RXMSC:MO=mo...,SWVER=+ +;
|swver |
+ +
Managed Objects CF
+ +
|DEFAULT|
RXMSC:MO=mo...,SWVER=+ +;
|swver |
+ +
Managed Object TF
RXMSC:MO=mo...,TFMODE=tfmode;
Managed Object TX
RXMSC:MO=mo...,ANT=ant;
Managed Object RX
+ ++ +
RXMSC:MO=mo...|,ANTA=anta||,ANTB=antb|;
+ ++ +
E.g.RXCAP:MO= RXETRX-1-2;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 29 of 132
RXBLE:MO=mo...;
+ +
|MOTY=moty|+ ++ +
RXPLI: + +|,UC||,IO=io|;
|MO=mo... |+ ++ +
+ +
+ +
|MOTY=moty|
RXPLE: + +;
|MO=mo... |
+ +
RXTEI:MO=mo...;
RXTEE:MO=mo...;
RXLTI:MO=mo...;
RXCDP:MO=mo...;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 30 of 132
+ ++ +
|MOTY=moty|| |
RXELP:+ +|,IO2=io2|;
|MO=mo... || |
+ ++ +
RXHDP:MO=mo...;
+ +
RAHPI: MP=mp +, IO=io+ ;
+ +
RXHMP;
RXHEI;
+ +
|MOTY=moty|
RXMDP:+ +;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 31 of 132
|MO=mo... |
+ +
+ +
| + + |
|MOTY=moty|,FAULTY| |
| + + |
RXMFP:+ +;
| + ++ +|
|MO=mo...|,FAULTY||,SUBORD||
| + ++ +|
+ +
+
| + +
| | + +|
+ + | | |almask...||
| MOTY=moty | |+ +| | ||
RXALC:+ + +|,TGCOORD=tgcoord||,ALMASK=+CLEAR +|
| MO=mo... | |+ +| | ||
+ + | | |ALL ||
| | + +|
| + +
+
+
|
|
|
+ +|
|,ALCOTIM=alcotim|+;
+ +|
|
|
|
+
+ +
|MOTY=moty|
RXALP:+ +;
|MO=mo... |
+ +
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 32 of 132
|MOTY=moty|
RXASP:+ +;
|MO=mo... |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 33 of 132
COMB=comb Combiner.
Combiner type used in the TG.
FLT or HYB.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 34 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 35 of 132
FAULTY Faulty.
This parameter specifies that only
information on faulty managed object
instances is to be printed.
BB Baseband hopping.
SY Synthesiser hopping.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 36 of 132
5.2.1.25 IO IO Device.
IO2=io2 IO Device.
Identifier of the alphanumeric device to
which the printout is directed. This is
only required if the printout is to be
directed to a different IO from
the one on which the printout is ordered.
Expressed as dt-n where
dt IO Device Type.
Identifier 1-7 characters.
n IO Device Number.
Numeral 0-255.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 37 of 132
NOTRAFF No Traffic.
Indicates that the TRXC is not used for
speech and data.
UNCONC Unconcentrated
CONC LAPD concentrated
MPLEX16 16K Multiplex
MPLEX32 32K Multiplex
SUBORD Subordinate.
This parameter specifies that fault
information is also to be given on managed
object instances which are subordinate to
to the specified managed object instance(s).
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 38 of 132
of 1 - 12 characters.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 39 of 132
5.2.1.41 UC Unconditional
TGC FAULT
No active TGC application exists
in the transceiver group.
PERMANENT FAULT
A managed object is classified as
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 40 of 132
LMT INTERVENTION
Local maintenance activities being
performed in the BTS.
CLASS 1 FAULT
A fault exists in a piece of BTS
equipment that leads to that
equipment not being able to carry
out its operational function.
OML FAULT
A fault exists in the
communications link between the
BSC and the BTS.
TS SYNC FAULT
Synchronization lost on uplink or
downlink TRAU channels.
CLASS 2 FAULT
A fault in BTS equipment that does
not directly interfere with its
operational function.
:xmp LOOP TEST FAILED Test of the traffic carrying capabilities of the TS has failed.
:xmp ant Antenna Designation. Name of antenna connected to transmitter. This parameter is
represented by a string of 1-7 characters.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 41 of 132
TRXC SIGNALLING
The Abis path is used
for TRXC signalling.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 42 of 132
bits 0 to 3:
bit 3 2 1 0
+-----+-----+-----+-----+
| BNP | BNL | BNR | BNU |
+-----+-----+-----+-----+
bits 4 to 7:
bit 7 6 5 4
+-----+-----+-----+-----+
| BNS | BND | BNI | BNT |
+-----+-----+-----+-----+
bits 8 to 9:
bit 9 8
+-----+-----+
| BNO | BNM |
+-----+-----+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 43 of 132
bits 0 to 3:
bit 3 2 1 0
+-----+-----+-----+-----+
| TG | AS | AT | AP |
+-----+-----+-----+-----+
bits 4 to 7:
bit 7 6 5 4
+-----+-----+-----+-----+
| X | OML | TGC | TRXC|
+-----+-----+-----+-----+
bits 8 to 11:
bit 11 10 9 8
+-----+-----+-----+-----+
| LOOP| LOM | CF | LMT |
+-----+-----+-----+-----+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 44 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 45 of 132
class Class
The class of the most severe alarm in the
external alarm list. Class may be 1 or 2,
1 being the most severe.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 46 of 132
comb Combiner.
Combiner type used in the TG.
FLT or HYB.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 47 of 132
date Date.
The date the error was received, in the format
yy-mm-dd, where yy represents the year, mm the
month and dd the date that the error was
entered into the log.
This is a string eight characters long.
dev Device
[Mandatory description of device.]
Logical device used to connect the managed
object DP to Digital Path supervision
functions.
Transcoder device.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 48 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 49 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 50 of 132
BB Baseband hopping.
SY Synthesiser hopping.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 51 of 132
INSUFFICIENT TX EQUIPMENT
Insufficient managed objects of class TX,
with suitable capabilities are available
within this TG to meet the cell
requirement at the time of the configu-
ration. If more TX equipment has become
available since configurtion was started,
the cell must be halted and activated to
include these TXs in the configuration.
5.3.1.58 io IO Device.
LOADED
The managed object instance
has been loaded.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 52 of 132
INSUFFICIENT MEMORY
Unable to load the operational
software required for the managed
object instance due to insufficient
BSC memory.
BUFFER CONGESTION
Allocation of dynamic buffer
failed.
NO TRH AVAILABLE
Unable to load the operational
software because there is no
available tranceiver handler.
LOADING FAILED
The communication between the
BSC and the managed object in
the BTS has failed during the
software loading process.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 53 of 132
Bits 4 to 7:
bit 7 6 5 4
+-----+-----+-----+-----+
| X | ENA | CRN | X |
+-----+-----+-----+-----+
X Spare
CRN LTF blocked due to
creation in progress.
ENA LTF blocked due to not
enabled
Bits 8 to 11 :
bit 11 10 9 8
+-----+-----+-----+-----+
| X | X | X | MO |
+-----+-----+-----+-----+
Bits 4 to 7:
bit 7 6 5 4
+-----+-----+-----+-----+
| X | ENA | CRN | X |
+-----+-----+-----+-----+
Bits 8 to 11:
bit 11 10 9 8
+-----+-----+-----+-----+
| DEV | RSL | LTF | MO |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 54 of 132
+-----+-----+-----+-----+
Bits 12 to 15:
bit 15 14 13 12
+------+-----+-----+-----+
| CHG | X |SYNCB| X |
+------+-----+-----+-----+
X Spare
SYNCB LTS blocked due to synchronization
fault in BTS.
(Speech/data connection)
CHG Blocked due to change
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 55 of 132
NO FAULT INDICATIONS
The test of the managed object individual
has taken place and no faults were found.
5.3.1.71 NONE
5.3.1.72 NO PARAMETERS
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 56 of 132
ORDERED
The command was ordered for the
managed object.
EXECUTED
The command was executed for the
managed object.
FUNCTION BUSY
Function busy.
MO BUSY
The managed object instance
is currently in use by another
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 57 of 132
function.
MO NOT DEFINED
The managed object instance
is not defined.
ABORTED BY OPERATOR
Software loading is aborted due to
operator command RX***.
EXECUTED
The managed object instance is
in service.
ABORTED
The process of bringing the managed
object into service was aborted.
The managed object is not in service.
MO IS ENABLED
The managed object instance
is currently enabled.
SUBORDINATE MO IS ENABLED
The managed object instance
has a subordinate object
that is currently enabled.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 58 of 132
LOADING FAILED
The communication between the
BSC and the managed object in
BTS has failed during the
software loading process.
INSUFFICIENT MEMORY
Unable to load the operational
software required for the managed
object instance due to insufficient
BSC memory.
BUFFER CONGESTION
Allocation of dynamic buffer
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 59 of 132
failed.
BLOCKED
The managed object is not in global
state OPER and is therefore not
available to the configuration
function.
CONFIG
The managed object is configured
with the indicated parameters.
FAILED
An attempt to configure this
managed object was not successful.
N/A
The managed object is not of class
RX, TG, TS, TX or DP therefore
configuration data is not
appropriate.
UNUSED
The managed object is not
configured, no other parameters
are printed for this managed
object.
CONFIG
The managed object is configured
with the indicated parameters.
UNCONFIG
The managed object is not
configured, no other parameters
are printed for this managed
object.
BUSY
The managed object instance
is currently in use by another
function.
N/A
The managed object is not of class
TS, therefore configuration
hopping data is not
appropriate.
UNDEF
The managed object instance is
not defined.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 60 of 132
LOADING FAILED
The test failed because
loading of the managed
object was unsuccessful.
TEST SUCCESSFUL
The test has been performed
and is successful.
LOADING FAILED
The test has failed because
loading of the managed object
instance was unsuccessful.
TEST FAILED
The test has been unsuccessful.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 61 of 132
EXECUTED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 62 of 132
EXECUTED
result SUCCESSFUL
A configuration was made for
this TG and extra TX equipment
is incorporated in the HFS.
UNSUCCESSFUL
A configuration was made for
this TG, however no extra
TX equipment is incorporated
in the HFS.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 63 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 64 of 132
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 65 of 132
TF NOT SYNCHRONIZED
The managed objects within the TG are not
currently used to support the cell because
the TF is not synchronized.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 66 of 132
time Time.
The time the error was received, in the format
hh-mm-ss, where hh represents the hour, mm the
minute and ss the second that the error was
entered into the log.
This is a string eight characters long.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 67 of 132
details
details
The MO parameter specified managed object
instances from more than
one BTS logical model.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 68 of 132
details
details More than 6 Transcoder MUX devices
were specified or more than
3 devices specified.
4 WRONG MO CLASS
details
5 MO BUSY
details
details
The managed object instance is not
in an appropriate state. The managed
object cannot already be defined.
details
No more managed objects of the specified managed object
type can be defined due to lack of MO data individuals.
Increase the MO data file in the RXCMSD block.
details
[moty] The managed object type for which
the function change is in progress.
9 MO CANNOT BE UNDEFINED
details
details
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 69 of 132
details
details
details
No more managed objects of this class can be defined in this BSC. The maximum
allowed number of managed object instances of this managed object class is reached.
details
No more connections are allowed
to this transmission device.
details No more radio site identities can be loaded into the radio site conversion table.
details
The managed objects specified in the command must belong to the same
managed object class.
details
The specified cell has not been defined. Command RLDEI may be used to define a cell.
details
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 70 of 132
details
The command is aborted due to another function with higher priority wanting
access to the processed managed object instance.
details
The device specified is of a type
which cannot be connected to a DP
managed object.
details
The device specified is already
connected to a DP managed object
23 SPARE
details
The specified TEI/CTEI has already
been assigned to a managed object
which uses the same transmission
device.
details
details
details
details
The channel group is not halted. Command RLSTC may be used to halt a channel
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 71 of 132
group.
details
The channel group is not defined. Command RLCFI may be used to define a channel
group.
30 SPARE
details
details
details
details
details
details
details
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 72 of 132
details
details
details
Insufficient LAPD concentration
factor on transmission device.
It is only allowed to concentrate
TRXCs on the same transmission
device up to and including the
LAPD concentration factor used
on the transmission device.
The restricting LAPD concentration
factor may be specified for any
transceiver group using the
transmission device.
43 SPARE
44 SPARE
details
46 SPARE
details
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 73 of 132
details
details
details
49 SPARE
details
RIETI:DEV=dev,EQMTYPE=eqmtype;
RIETE:DEV=dev...;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 74 of 132
RISPE:TSLOT=tslot...;
+ +
| |
| + ++ ++ + |
|EMG=ALL |,STATE=state||,PRI=pri||,REL| |
| + ++ ++ + |
| |
| |
| |
| + + |
RISPP: + |emrs | + ++ ++ ++;
|EMG=emg,EMRS= + + |,STATE=state||,PRI=pri||,REL||
| |ALL | + ++ ++ +|
| + + |
| |
|TSLOT=tslot.... |
| |
|NAME=name |
+ +
RICSC:EMG=emg,EMRS=emrs;
+ +
|EMG=ALL |
| |
| + + |
RICSP: + |emrs....| +;
|EMG=emg,EMRS= + + |
| |ALL | |
| + + |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 75 of 132
+ +
| EMG=ALL |
| + + |
| | emrs... | |
RILTP: + EMG=emg, EMRS= + + +;
| | ALL | |
| + + |
| DEV=dev... |
+ +
+ +
| EMG=ALL @,STATE=state ` |
| |
| + + |
| | emrs... | |
| EMG=emg, EMRS= + + @,STATE=state ` |
RILSP: + | ALL | +;
| + + |
| |
| DEV=dev... |
| |
| TSLOT=tslot... |
+ +
6.1.5 Commands RIRTI, RITTI, Radio Selector Test & Line Terminal Test
RIRTI:EMG=emg,EMRS=emrs;
RITTI:DEV=dev;
+ +
|EMG=emg,EMRS=emrs|
RIBLI: + + ;
|DEV=dev... |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 76 of 132
+ +
|EMG=emg,EMRS=emrs|
RIBLE: + + ;
|DEV=dev... |
+ +
+ +
|emrs... |
RIDCP:EMG=emg,EMRS= + +;
|ALL |
+ +
+ +
|emrs....|
RISTP:EMG=emg,EMRS= + +;
|ALL |
+ +
+ +
|CTSLOT=ctslot....|
RICCE: + + ;
|NCTSLOT=nctslot. |
+ +
E.g.RICCE: NCSTSLOT=RILT-9-31;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 77 of 132
+ +
| EMG=ALL |
| + + |
RICCP | | + + | |
| | emg |, EMRS= emrs + | | ;
| EMG=+ + + | |
| | ALL | |
| + + |
+ +
RICBI:DEV=dev, CONCB=concb ;
E.g.RICBI:DEV=RILT-4,CONCB=RILCO-8 ;
RICBE:DEV= dev ;
+ +
| CONCB=concb |
| |
| DEV=dev |
| + + |
RICCP | | + + | |
| | emg |, EMRS= emrs + | | ;
| EMG=+ + + | |
| | ALL | |
| + + |
+ +
FAULT CODE 3
DEVICE NOT FULLY CONNECTED
The device is not fully connected.
FAULT CODE 4
EQUIPMENT TYPE DOES NOT EXIST
The specified equipment type does
not exist.
FAULT CODE 6
NAME NOT DEFINED
The given name does not exist.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 78 of 132
FAULT CODE 10
EMRS TEMPORARILY BUSY WITH OTHER TASKS
The EMRS is temporarily busy
with other tasks.
FAULT CODE 12
DEVICE ALREADY CONNECTED TO EQUIPMENT TYPE
The device is already connected
to an equipment type.
FAULT CODE 13
DEVICE NOT CONNECTED TO EQUIPMENT TYPE
The device is not connected to
any equipment type.
FAULT CODE 16
DEVICE NOT MANUALLY BLOCKED
Device not manually blocked.
FAULT CODE 18
EMRS NOT MANUALLY BLOCKED
The EMRS must be manually
blocked to execute this command.
FAULT CODE 19
EMRS ALREADY MANUALLY BLOCKED
The EMRS is already manually
blocked.
FAULT CODE 20
TOO MANY TIMESLOTS SPECIFIED
Too many timeslots are
specified by the same command.
FAULT CODE 21
TIMESLOT ALREADY CONNECTED
The indicated timeslot is
already used in a semipermanent
path.
FAULT CODE 23
FAULTY EQUIPMENT TYPE
The specified device is connected
to faulty equipment type.
FAULT CODE 24
FAULTY DEVICE STATE
The indicated device must not be
in a manually blocked state.
FAULT CODE 25
TIMESLOTS NOT IN THE SAME EMRS
The timeslots are not connected
to the same EMRS.
FAULT CODE 26
TIMESLOT IS SYSTEM BUSY
The indicated timeslot is used
by the system for frame
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 79 of 132
FAULT CODE 27
ERROR IN EMRS Error in EMRS.
It is not possible to initiate
a semipermanent path in th EMRS.
FAULT CODE 28
STORAGE SPACE EXCEEDED IN RISPC
No storage space in RISPC.
FAULT CODE 29
DEVICE SEMIPERMANENTLY CONNECTED
The indicated device is semi-
permanently connected.
FAULT CODE 30
TIMESLOTS NOT IN THE SAME DEVICE
The indicated timeslot does
not belong to the same device
as the previous timeslot.
FAULT CODE 31
EM BLOCKED
The command cannot be executed
while the EM is blocked.
FAULT CODE 33
TOO MANY DEVICES SPECIFIED
A maximum of 16 devices can be
given in the same command.
FAULT CODE 35
DEVICE NOT CONNECTED TO EM
The specified device is not
connected to EM.
FAULT CODE 36
TIMESLOT IN TEST
The indicated timeslot is occupied
by test.
FAULT CODE 37
STANDBY INLET FAULTY
The standby synchronization inlet
must not be faulty to execute this
command.
FAULT CODE 38
STANDBY SYNCHRONIZATION DEVICE BLOCKED
The device used as standby
synchronization inlet must not
be manually blocked or control
blocked to execute this command.
FAULT CODE 39
EMRS MANUALLY BLOCKED
The indicated EMRS must not be
manually blocked to execute this
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 80 of 132
command.
FAULT CODE 40
STANDBY INLET NOT CONNECTED
The device used as standby synchro-
nization inlet is not fully
connected.
FAULT CODE 41
DEVICE CONNECTED TO DIGITAL PATH
The indicated device is connected
to a digital path.
FAULT CODE 43
DEVICE EXCEPT THE EXECUTIVE INLET NOT BLOCKED
All the devices in the EMRS except
the device used as executive
synchronization inlet must be
manually blocked to execute this
command.
FAULT CODE 47
TOO MANY EMRS SPECIFIED
A maximum of 16 EMRSs can be
given in the same command.
FAULT CODE 50
NO SYNCHRONIZATION INLETS DEBLOCKED
A device used as synchronization
inlet must be manually deblocked
to execute this command.
FAULT CODE 51
NO SYNCHRONIZATION INLET DEFINED
The command cannot be executed
since no synchronization inlet
is defined.
FAULT CODE 53
SEMIPERMANENT CONNECTION IN SYNCHRONIZATION DEVICE
The device used as executive
synchronization inlet contains
semipermanent connection(s).
FAULT CODE 54
INCOMPATIBLE TYPE OF HARDWARE
The hardware is not equipped
with a standby synchronization
facility.
FAULT CODE 55
RICS TEMPORARILY BUSY
The function block RICS is
temporarily busy with other
tasks.
FAULT CODE 56
NO ANSWER FROM EMRP
It is not possible to determine
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 81 of 132
FAULT CODE 57
STORAGE SPACE EXEEDED IN RISPH
No storage space in RISPH.
FAULT CODE 58
TIMESLOT NOT CONNECTED BY COMMAND RISPI
The indicated timeslot is not
connected to a path set up by
command RISPI.
FAULT CODE 59
DEVICE ALREADY CONNECTED TO CONCENTRATOR BOARD
The specified device is already
connected to a LAPD concentrator
board.
FAULT CODE 60
CONCENTRATOR BOARD ALREADY CONNECTED TO DEVICE
The specified LAPD concentrator
board is already connected to a
device.
FAULT CODE 61
CONCENTRATOR BOARD NOT CONNECTED TO EM
The specified LAPD concentrator
board is not connected to EM.
FAULT CODE 62
DEVICE NOT CONNECTED TO CONCENTRATOR BOARD
The device is not connected a
LAPD concentrator board.
FAULT CODE 63
CONCENTRATORS CONNECTED ON CONCENTRATOR BOARD
The indicated device has LAPD
concentrators connected.
FAULT CODE 64
TOO MANY CONCENTRATOR BOARDS SPECIFIED
A maximum of 16 LAPD concentrator
boards can be specified by the
same command.
FAULT CODE 65
CONCENTRATOR BOARD NOT FULLY CONNECTED
The specified LAPD concentrator
board is not fully connected.
FAULT CODE 66
TEI VALUE ALREADY USED FOR THE CONCENTRATOR
The specified TEI value has
already been used for the
LAPD concentrator.
FAULT CODE 67
TOO MANY TEI VALUES SPECIFIED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 82 of 132
FAULT CODE 69
TIMESLOTS AND CONCENTRATOR BOARD NOT IN SAME EMRS
The specified timeslots and
LAPD concentrator board are
not connected to the same
EMRS.
FAULT CODE 70
TOO MANY NCTSLOTS CONNECTED TO CONCENTRATOR
Too many non-concentrated
timeslots are connected
to the LAPD concentrator.
FAULT CODE 71
NOT ENOUGH TIMESLOTS AVAILABLE ON CONCENTRATOR BOARD
There are not enough timeslots
available for the LAPD
concentrator.
FAULT CODE 74
RILT DEVICE AND CONCENTRATOR BOARD NOT IN THE SAME EMG
The specified device and LAPD
concentrator board are not
connected to the same EMG.
FAULT CODE 75
FAULTY SPECIFICATION OF TSLOT
The indicated timeslot has been
specified in a faulty context.
FAULT CODE 76
TSLOT NOT CONN TO CONCENTRATOR
The indicated timeslot is not
connected to a concentrator.
FAULT CODE 77
TOO MANY DEVICES SPECIFIED
A maximum of 16 RILT devices
can be specified by the samme
command.
FAULT CODE 78
DEVICE CONNECTED TO CONCENTRATOR BOARD
The indicated device is
connected to a LAPD concentrator
board.
FAULT CODE 79
TEST LOOP PATH DEFINED
A test loop path is defined
for the stated LAPD concentrator
board.Disconnection of the test
loop path has failed.
FAULT CODE 80
TOO MANY CONCENTRATORS SPECIFIED
More than 10 LAPD concentrators
are not allowed to be specified
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 83 of 132
+ +
| DEV=dev |
RAPTI:| LCH=lch +;
| CIC=cic |
+ +
RADPI:DPC=dpc,NEI=nei;
END
RADPE;
RADPP;
RADCI:SP=sp;
END
RADCE;
RADCP;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 84 of 132
CHANGE
RARMC: TRANSMTYPE=transmtype;
RADMP;
CHANGE
RASIC: SIGTYPE=sigtype;
RASIP;
RASSI:DETY=dety;
+ +
RASSE:DETY=dety |,PERM|;
+ +
SEIZURE SUPERVISION OF DEVICES, PRINT
RASSP:DETY=dety;
RASAR:DETY=dety;
+ +
|PL=pl ACL=acl`|
RASSC:DETY=dety,+ +;
|ACL=acl |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 85 of 132
+ +
+ +
| EV |
RTYPE = + + ;
| EV & ME TIMEW=timew |
+ +
RATRE;
RATRP;
FAULT CODE 2
SUPERVISION IS ALREADY DISCONNECTED
FAULT CODE 3
CELL NOT DEFINED
FAULT CODE 4
SUPERVISION CANNOT BE DISCONNECTED WHEN ALARM
IS ISSUED
FAULT CODE 5
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 86 of 132
FAULT CODE 6
INVALID DEVICE TYPE SPECIFIED
FAULT CODE 7
DEVICE TYPE DOES NOT HAVE PPS FUNCTION
FAULT CODE 9
INCORRECT ALARM LIMIT VALUE SPECIFIED
FAULT CODE 10
SUPERVISION IS ALREADY PERMANENTLY DISCONNECTED
FAULT CODE 11
ALARM CLASS CANNOT BE CHANGED, ALARM ISSUED
FAULT CODE 12
A LOWER ALARM LIMIT VALUE IS GREATER THAN
A HIGHER ALARM LIMIT VALUE
FAULT CODE 13
TWO OR MORE ALARM LIMITS MAY NOT HAVE THE SAME
ALARM CLASS
FAULT CODE 14
NO ALARM GIVEN
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 87 of 132
FAULT CODE 15
INVALID TIME PERIOD SPECIFIED
FAULT CODE 18
NO DEVICE DATA AVAILABLE FOR OUTPUT
FAULT CODE 20
THE DEVICE IS NOT IN PPS
FAULT CODE 22
CIC NOT DEFINED
FAULT CODE 23
CIC ALREADY DEFINED
FAULT CODE 24
CIC ALREADY USED FOR ANOTHER DEVICE
FAULT CODE 25
RECORDING NOT ACTIVE
FAULT CODE 27
DESTINATION POINT CODE ALREADY LOADED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 88 of 132
FAULT CODE 28
DESTINATION POINT CODE NOT LOADED
FAULT CODE 29
DATA CHANGE IN PROGRESS
FAULT CODE 30
DATA CHANGE COMMAND HAS BEEN INITIATED
FAULT CODE 31
ALL DEVICES ARE NOT IN PPS
FAULT CODE 33
MEASURING PROGRAM ALREADY OCCUPIED
FAULT CODE 35
RECORDING ALREADY INITIATED FOR ORDERED CELL
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 89 of 132
FAULT CODE 38
COMMAND NOT VALID FOR EXTERNAL CELLS
FAULT CODE 41
TRANSCEIVER TEST EQUIPMENT ALREADY DEFINED
FAULT CODE 42
TRANSCEIVER TEST EQUIPMENT NOT DEFINED
FAULT CODE 43
TRANSCEIVER AUTOMATIC SUPERVISION ACTIVE
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 90 of 132
FAULT CODE 44
TRANSCEIVER PERIODIC TEST ACTIVE
FAULT CODE 45
TRANSCEIVER PERIODIC TEST NOT ACTIVE
FAULT CODE 46
CELL INCLUDED IN TRANSCEIVER PERIODIC TEST
FAULT CODE 47
CELL EXCLUDED FROM TRANSCEIVER PERIODIC TEST
FAULT CODE 48
TOO MANY CELLS SPECIFIED
FAULT CODE 50
CELL STATE NOT ACTIVE
FAULT CODE 51
INCLUDED IN PERIODIC TEST AND AUTOMATIC SUPERVISION ACTIVE
FAULT CODE 52
TOO MANY SIMULTANEOUS TRANSCEIVER TESTS
FAULT CODE 53
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 91 of 132
FAULT CODE 54
DESTINATION POINT CODE NOT IN ACCORDANCE WITH SIGNALLING TYPE
FAULT CODE 55
DEVICE FILE SIZE GREATER THAN ZERO -
RESTRICTING BLOCK = block
FAULT CODE 56
BSC EXCHANGE PROPERTY DESIGNATION NOT RECOGNIZED.
FAULT CODE 57
BSC EXCHANGE PROPERTY VALUE NOT ACCEPTED
FAULT CODE 58
DATA MISMATCH
FAULT CODE 59
FILE SIZE ALTERATION NEEDED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 92 of 132
FAULT CODE 61
REARRANGEMENT ALREADY IN PROGRESS
FAULT CODE 62
TRH LOAD DATA CHANGE IN PROGRESS
FAULT CODE 63
TOO MANY INTERVALS REQUESTED
FAULT CODE 64
MEASURING PROGRAM NOT FOUND
FAULT CODE 65
SWITCHING NETWORK TERMINAL IS NOT
CONNECTED TO THE SWITCH
FAULT CODE 66
DP DEFINED
FAULT CODE 67
MAXIMUM NUMBER OF RECORDINGS IN PROGRESS
FAULT CODE 68
LOAD DATA DOES NOT EXIST FOR THIS SNT TYPE
FAULT CODE 69
NEW LOAD VALUES RECEIVED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 93 of 132
FAULT CODE 70
THE FUNCTION IS ALREADY INITIATED
INITIATE
RLTYI:GSYSTYPE=gsystype;
RLTYP;
END
RLTYE;
RLTYC: GSYSTYPE=gsystype ;
INITIATE
+ +
RLDEI:CELL=cell |,EXT | , CSYSTYPE= csystype;
+ +
CHANGE
+
|
|+ + + +
RLDEC:CELL=cell +| ,CGI=cgi | | ,BSIC=bsic |
|+ + + +
|
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 94 of 132
+ + + +
| ,BCCHNO=bcchno | | ,AGBLK=agblk |
+ + + +
+ + + +
| ,MFRMS=mfrms | | ,BCCHTYPE=bcchtype|
+ + + +
+
|
+ + + +|
| ,FNOFFSET=fnoffset | | ,XRANGE=xrange |+ ;
+ + + +|
|
PRINT
+ +
| cell... |
| |
RLDEP:CELL=+ + ++ , CSYSTYPE= csystype ;
| |,EXT ||
| ALL + +|
| |,XRANGE ||
+ + ++
END
RLDEE:CELL=cell;
INITIATE
RLDSI:CELL=cell...;
END
RLDSE:CELL=cell...;
CHANGE
+ +
| cell... |
RLDTP:CELL=+ +;
| ALL |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 95 of 132
+ +
INITIATE
+ +
|,DCHNO=dchno... |
| |
RLCFI:CELL=cell + +;
|,CHGR=chgr ,DCHNO=dchno... |
| |
+ +
+ +
| |
| + + |
| cell, |,CHGR=chgr... | |
RLCFP: CELL=+ + + +;
| cell... |
| |
| ALL |
END
RLCFE:CELL=cell,DCHNO=dchno...;
+ +
| + + |
+ + |,HOP=hop |,HSN=hsn| |
RLCHC:CELL=cell |,CHGR=chgr| + + + +;
+ + | |
|,HSN=hsn |
+ +
INITIATE
+ +
RLDGI: CELL=cell,CHGR=chgr... |,SCTYPE=sctype |;
+ +
CHANGE
RLDGC:CELL=cell,CHGR=chgr...,SCTYPE=sctype;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 96 of 132
+ +
| cell... |
RLDGP: CELL=+ + ;
| ALL |
+ +
END
RLDGE:CELL=cell,CHGR=chgr...;
INITIATE
+ +
RLDCI:|EMERGPRL=emergprl|;
+ +
RLDCP;
END
RLDCE;
CHANGE
+ + + +
RLMFC:CELL=cell,MBCCHNO=mbcchno...| ,LISTTYPE=listtype | |, MRNIC | ;
+ + + +
+ +
| cell... | + +
RLMFP:CELL= + + | ,LISTTYPE=listtype | ;
| ALL | + +
+ +
END
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 97 of 132
+ +
| mbcchno... | + + + +
RLMFE:CELL=cell,MBCCHNO= + + | ,LISTTYPE=listtype | |, MRNIC | ;
| ALL | + + + +
+ +
CHANGE
+ + + +
| | sctype | |
RLCPC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+ +
|+ + + + + +|
+|,MSTXPWR=mstxpwr | |,BSPWRT=bspwrt | |,BSPWRB=bspwrb |+;
|+ + + + + +|
+ +
PRINT
+ +
| cell... |
| |
RLCPP: CELL= + + + + ;
| ALL |,EXT | |
| + + |
+ +
CHANGE
+
|+ ++ ++ +
RLCCC:CELL=cell+|,TN=tn ||,CHGR=chgr ||,SDCCH=sdcch |
|+ ++ ++ +
+
+
+ +|
|,CBCH=cbch |+;
+ +|
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 98 of 132
CHANGE
+ +
| |
RLBDC:CELL=cell|,CHGR=chgr |,NUMREQBPC=numreqbpc;
| |
+ +
+ +
| |
| + + |
| cell |,CHGR=chgr... | |
RLBDP: CELL=+ + + +;
| cell... |
| |
| ALL |
+ +
CHANGE
RLCAC: ALG=alg;
RLCAP;
CHANGE
+ + ++
| |chgr...||
RLSTC:CELL=cell|,CHGR=+ +|,STATE=state;
| |ALL ||
+ + ++
+ +
| cell... |
| |
RLSTP:CELL= + + + + ;
| ALL |,STATE=state| |
| + + |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 99 of 132
CHANGE
RLCXC:CELL=cell, DTXD=dtxd;
PRINT
+ +
| cell... |
RLCXP:CELL= + + ;
| ALL |
+ +
+ +
|cell... |
RLCRP:CELL=+ +;
|ALL |
+ +
INITIATE
+ +
RLNRI:CELL=cell,CELLR=cellr | ,SINGLE | ;
+ +
PRINT
+
| + +
+
| + + + +
RLNRC:CELL=cell,CELLR=cellr + | ,CS=cs | | ,CAND=cand |
| + + + +
+
+ + + +
+ + | | KOFFSETP=koffsetp | |
| ,KHYST=khyst | |, + + |
+ + | | KOFFSETN=koffsetn | |
+ + + +
+ + + +
+ + | | LOFFSETP=loffsetp | |
| ,LHYST=lhyst | |, + + |
+ + | | LOFFSETN=loffsetn | |
+ + + +
+ + + +
+ + | | TROFFSETP=troffsetp | |
| ,TRHYST=trhyst | |, + + |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 100 of 132
+ + | | TROFFSETN=troffsetn | |
+ + + +
+
+ + + + |
| ,AWOFFSET=awoffset | | ,BQOFFSET=bqoffset | +;
+ + + + |
+
PRINT
+ + + +
| | cellr... | |
| CELL=cell ,CELLR= + + | + +
RLNRP: + | ALL | + | ,NODATA | ;
| CELL=ALL + + | + +
| |
+
END
RLNRE:CELL=cell,CELLR=cellr;
+ +
| cell... |
RLLDP:CELL= + + ;
| ALL |
+ +
CHANGE
+ +
|+ + + +|
RLLDC:CELL=cell +| ,MAXTA=maxta | | ,RLINKUP=rlinkup |+ ;
|+ + + +|
+ +
CHANGE
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 101 of 132
+ + + +
| | sctype | |
RLLOC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+
| + + + +
+ |,BSPWR=bspwr | |,BSTXPWR=bstxpwr |
| + + + +
+
+ + + +
|,BSRXMIN=bsrxmin| |,BSRXSUFF=bsrxsuff |
+ + + +
+ + + +
|,MSRXMIN=msrxmin | |,MSRXSUFF=msrxsuff |
+ + + +
+ + + + + +
|,SCHO=scho | |,MISSNM=missnm | |,AW=aw |
+ + + + + +
+
+ + |
| ,EXTPEN=extpen | + ;
+ + |
+
+ +
| cell... |
| |
RLLOP:CELL= + + + + ;
| ALL | ,EXT | |
| + + |
+ +
CHANGE
+ + + +
| | sctype | |
RLLUC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+
| + + + +
+ |,QLIMUL=qlimul | |,QLIMDL=qlimdl |
| + + + +
+
+
+ + + + |
|,TALIM=talim | |,CELLQ=cellq | +;
+ + + + |
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 102 of 132
CHANGE
+
|+ + + +
RLLBC: +| TAAVELEN=taavelen | | ,TINIT=tinit |
|+ + + +
+
+ + + +
| ,TALLOC=talloc | | ,TURGEN=turgen |
+ + + +
+ + + +
| ,EVALTYPE=evaltype | | ,TINITAW=tinitaw |
+ + + +
+ + + +
| ,TALLOCAW=tallocaw | | ,ASSOC=assoc |
+ + + +
+
+ + + +|
| ,IBHOASS=ibhoass | | ,IBHOSICH=ibhosich |+ ;
+ + + +|
+
CHANGE
+
|+ + + +
RLLFC:CELL=cell +| ,SSEVALSD=ssevalsd | | ,QEVALSD=qevalsd |
|+ + + +
+
+ + + +
| ,SSEVALSI=ssevalsi | | ,QEVALSI=qevalsi |
+ + + +
+ + + +
| ,SSLENSD=sslensd | | ,QLENSD=qlensd |
+ + + +
+ + + +
| ,SSLENSI=sslensi | | ,QLENSI=qlensi |
+ + + +
+
+ + + +|
| ,SSRAMPSD=ssrampsd | | ,SSRAMPSI=ssrampsi |+ ;
+ + + +|
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 103 of 132
+ +
| cell... |
RLLFP:CELL= + + ;
| ALL |
+ +
CHANGE
+
|+ + + +
RLLHC:CELL=cell +| ,LEVEL=level | | ,LEVTHR=levthr |
|+ + + +
+
+ + + +
| ,LEVHYST=levhyst | | ,PSSTEMP=psstemp |
+ + + +
+
+ +|
| ,PTIMTEMP=ptimtemp |+ ;
+ +|
+
+ +
| cell... |
| |
RLLHP:CELL=+ + + + + + ;
| ALL | ,LEVEL=level | | ,EXT | |
| + + + + |
+ +
CHANGE
+
| + + + +
RLOLC:CELL=cell + | ,LOL=lol | | ,LOLHYST=lolhyst |
| + + + +
+
+
+ + + + |
| ,TAOL=taol | | ,TAOLHYST=taolhyst | + ;
+ + + + |
+
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 104 of 132
+ +
| cell... |
RLOLP:CELL= + + ;
| ALL |
+ +
CHANGE
+
|+ + + +
RLLPC:CELL=cell +| ,PTIMHF=ptimhf | | ,PTIMBQ=ptimbq |
|+ + + +
+
+ + + +
| ,PTIMTA=ptimta | | ,PSSHF=psshf |
+ + + +
+
+ + + +|
| ,PSSBQ=pssbq | | ,PSSTA=pssta |+ ;
+ + + +|
+
+ +
| cell... |
RLIHP:CELL= + + ;
| ALL |
+ +
CHANGE
+ + + +
| | sctype | |
RLIHC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+
| + + + +
+ |,IHO=iho | |,MAXIHO=maxiho |
| + + + +
+
+ + + +
|,TMAXIHO=tmaxiho | |,TIHO=tiho |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 105 of 132
+ + + +
+ + + +
| | ,SSOFFSETULP=ssoffsetulp | |
| + + |
| | ,SSOFFSETULN=ssoffsetuln | |
+ + + +
+ + + +
| | ,SSOFFSETDLP=ssoffsetdlp | |
| + + |
| | ,SSOFFSETDLN=ssoffsetdln | |
+ + + +
+ + + +
| | ,QOFFSETULP=qoffsetulp | |
| + + |
| | ,QOFFSETULN=qoffsetuln | |
+ + + +
+ + + + +
| | ,QOFFSETDLP=qoffsetdlp | | |
| + + | +;
| | ,QOFFSETDLN=qoffsetdln | | |
+ + + + +
RLURP:MP=mp;
INIT
+ +
| cell... |
RLURI:MP=mp,LVUN=lvun,CELL= + + ,NP;
| ALL |
+ +
RLPCI:CELL=cell;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 106 of 132
+ + + +
| | sctype | |
RLPCC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+
|+ + + +
+| ,SSDES=ssdes | | , LCOMPUL=lcompul |
|+ + + +
+
+ + + +
| ,QDESUL=qdesul | | ,INIDES=inides |
+ + + +
+ +
| ,INILEN=inilen |
+ +
+ + + +
| ,PMARG=pmarg | | ,QLEN=qlen |
+ + + +
+ + + +
| ,DTXFUL=dtxful | | ,QCOMPUL=qcompul |
+ + | +
+ + + +
| ,QDESUL=qdesul | | ,REGINT=regint | + ;
+ + + +
RLPCE:CELL=cell;
INIT
RLBCI:CELL=cell;
CHANGE
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 107 of 132
| + + |
| | sctype | |
RLBCC:CELL=cell |,SCTYPE= + + |
| | ALL | |
+ + + +
+
|
|+ + + +
+| ,SDCCHREG=sdcchreg | |, REGINTDL =rgeintdl |
|+ + + +
|
+
+ + + +
| ,SSDESDL=ssdesdl | | ,SSLENDL=sslendl |
+ + + +
+ + + +
| ,SSDYNDL=ssdyndl | | ,PWRDYNDL=pwrdyndl |
+ + + +
+ + + +
| ,QLENDL=qlendl | | ,QVALDL=qvaldl |
+ + + +
+ + + +
| ,LCOMPDL=lcompdl | | ,QDESDL=qdesdldl |
+ + + +
+ +
| ,QCOMPDL=qcompdl
+ +
+ + +
| + + | |
| | BSPWRMINP=bspwrminp| | |
|, + + | + ;
| | BSPWRMINN=bspwrminn| | |
+ + + + |
+
+ +
| cell... |
RLBCP:CELL= + + ;
| ALL |
+ +
END
RLBCE:CELL=cell;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 108 of 132
INITIATE
+ +
RLMBI:CELL=cell, ID=id, CODE=code | ,UPDATE=update |
+ +
+ + + + + +
| ,MODE=mode | | ,NUMPAGES=numpages | | ,LANG=lang | ;
+ + + + + +
CHANGE
+ +
RLMBC: CELL=cell, ID=id, CODE=code | ,PAGE=page |
+ +
+ +
,TEXT=text... | ,PNO=pno |;
+ +
PRINT
+ +
| ID=id, CODE=code| + +
RLMBP:CELL=cell,+ + | ,NOTEXT |;
| ID=ALL | + +
+ +
END
+ +
| ID=id, CODE=code |
RLMBE:CELL=cell, + + ;
| ID=ALL |
+ +
INITIATE
+ +
| ,EDATE=edate, ETIME=etime | ,REP=rep;
+ +
+ +
| ID=id, CODE=code |
| |
RLMTP:CELL=cell, + + + + ;
| ID=ALL | ,STATE=state | |
| + + |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 109 of 132
9.16.1 Commands RLSSC, RLSSP, System Info SACCH & BCCH Data
CHANGE
+
|+ + + +
RLSSC:CELL=cell +| ,ACCMIN=accmin | | ,CCHPWR=cchpwr |
|+ + + +
+
+ + + +
| ,CRH=crh | | ,DTXU=dtxu |
+ + + +
+ + + +
| ,NCCPERM=nccperm... | | ,RLINKT=rlinkt |
+ + + +
+
+ + + + |
| ,MCBR=mcbr | | ,NECI=neci | + ;
+ + + + |
+
+ +
| cell... |
RLSSP:CELL=+ + ;
| ALL |
+ +
CHANGE
+
| + + + +
|+ + | | acc... | |
RLSBC:CELL=cell +| ,CB=cb | | ,ACC= + + |
|+ + | | CLEAR | |
| + + + +
+
+ + + +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 110 of 132
| ,MAXRET=maxret | | ,TX=tx |
+ + + +
+ + + +
| ,ATT=att | | ,T3212=t3212 |
+ + + +
+ + + +
| ,CBQ=cbq | | ,CRO=cro |
+ + + +
+
|
+ + + + + + |
| ,TO=to | | ,PT=pt | |ECSC=ecsc | + ;
+ + + + | | |
|
+
+ +
| cell... |
RLSBP:CELL=+ + ;
| ALL |
+ +
CHANGE
RLSMC:CELL=cell,SIMSG=simsg...,MSGDIST=msgdist;
+ +
| |
| cell... |
RLSMP:CELL= + + + + + + ;
| ALL |,SIMSG=simsg| |,MSGDIST=msgdist| |
| + + + + |
+ +
INITIATE
RLVLI:CELL=cell..., CHTYPE=chtype;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 111 of 132
+ +
RLVLI:CHTYPE=chtype |, SUPSTATE=supstate | ;
+ +
CHANGE
+ +
| PL=pl ,AL=acl` |
RLVLC: CELL=cell..., CHTYPE=chtype, + + ;
| ACL=acl |
+ +
RLVLP;
END
RLVLE:CHTYPE=chtype;
+ +
| cell... |
RLVLE:CELL= + +, CHTYPE=chtype;
| ALL |
+ +
RLVAP;
RESET
RLVAR: CHTYPE=chtype ;
INITIATE
+ +
RLSLI:CELL=cell...|,SCTYPE=sctype| ;
+
CHANGE
+ +
+ + |,LVA=lva ,AC=acl` |
RLSLC:CELL=cell...|,SCTYPE=sctype| + +
+ + |,ACL=acl |
+ +
,CHTYPE=chtype;
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 112 of 132
+ +
| cell... |
RLSLP:CELL= + +;
| ALL |
+ +
END
+ + + +
RLSLE:CELL=cell...|,SCTYPE=sctype| |,PERM |;
+ + + +
+
+ + |
+ | cell.. | |
| CELL= + | |
| | ALL | |
| + + |
RLHPP: | | ;
| + + |
| | chap...| +
| CHAP= + + |
| | ALL | |
| + + |
+ +
+
| + + + + + +
RLIMC : CELL= cell + |, INTAVE=intave | |,LIMIT1= limit1 | |, LIMIT2= limit2 |
| + + + + + +
+
+
+ + + + |
|, LIMIT3= limit3 | |, LIMIT4= limit4 | |;
| + + + |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 113 of 132
+ +
RLIMI: CELL=cell |, NOALLOC | ;
+ +
+ +
| cell.. |
RLIMP : CELL= + |
| ALL |
+ +
RLIMI: CELL=cell ;
+
| + + + +
RLLCC: CELL= cell + | CLSLEVEL= clslevel | | , CLSACC=clsacc |
| + + + +
+
|
+ + |
|, HOCLSACC=hoclasac | | ;
+ + |
+
+ +
| cell.. |
RLLCP : CELL= + |
| ALL |
+ +
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 114 of 132
RLLSE ;
RLLSI ;
RLLSP ;
RLOMC:MODE= mode ;
RLOMP;
+ +
| + + + + |
RLPPC : PP= pp, PRL=prl + |, PRL= prl | |, PROBF= probf | | ;
| + + + + |
+ +
RADIO CONTROL CELL BSC DIFFERENTIAL CHANNEL ALLOCATION
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 115 of 132
+ +
RADIO CONTROL CELL BSC DIFFERENTIAL CHANNEL ALLOCATION
+ +
| pp.. |
RLPPP : PP= + |
| ALL |
+ +
+ +
| pp.. |
RLLPP : PP= + |
| ALL |
+ +
+ +
RLPRC: CELL=cell |, SCTYPE=sctype | , CHTYPR= chtype, PP=pp ;
+ +
+
+ + |
+ | pp.. | |
| PP= + | |
| | ALL | |
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 116 of 132
| + + |
RLPRP: | | ;
| + + |
| | chap...| + + |
| CELL= + + |, CHTYPE=chtype | |
| | ALL | + + |
| + + |
+ +
RLSCE ;
RLSCI:STATSINT= statsint ;
RLSCP ;
+ +
| cell.. | + +
RLSDP : CELL= + | |, IO=io | ;
| ALL | + +
+ +
It is not allowed to define the same cell several times. A new cell designation must be given.
A managed object in the BTS is dedicated for use in this cell. An MO is identified in details.
Use command RXMOC to remove the dedication.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 117 of 132
The parameter NCCPERM has to be defined before activating the cell. Use the command
RLSSC to define NCCPERM.
It is not allowed to use the same names for both CELL and CELLR. It is not possible for a cell
to be its own neighbour.
The cell relation file in the BSC is full. It is only allowed to define up to 4096 relations in the
BSC.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 118 of 132
The same PLMN Colour Code permitted has already been given.
The parameters COMB/COMBC cannot be given if the parmater AGBLK has already been
defined with too large a value. See parameter range values.
EDATE is not greater than SDATE or EDATE equal to SDATE and ETIME is not greater than
STIME.
It is only allowed to specify measurement frequencies with a value range of maximum 278 per
cell if the Global system type is PCS 1900 or DCS 1800. If the Global system type is MIXED
and the Cell system type is GSM the maximum value range is 256 for the other band.
The cell cannot be deleted due to seizure supervision of logical channels. Seizure supervision
must be disconnected using the command RLVLE.
23 CELL IS CONNECTED TO TG
The cell cannot be deleted due to TG connection. A TG is identified in details. The connection
to the transceiver group must be removed using the command RXTCE.
26 NO TG CONNECTED
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 119 of 132
The absolute RF channel number is already used for another channel type.
The differential channel allocation statistics collection is ON. The Command RLSCE may used
to end the differential channel allocation statistics collection.
Individuals are not defined in LOAS. This must be done before the paging function can request
processor capacity. At least one individual must be defined.
The given relation already exists. The command RLNRE may be used to delete the existing
relationship.
It is not allowed to specify CBCH = yes for a channel group where SDCCH = 0.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 120 of 132
The parameter BSPWRB has to be defined before activating the cell. Use the command
RLCPC to define BSPWRB.
The parameter BSPWRT has to be defined before activating the cell. Use the command
RLCPC to define BSPWRT.
The parameter CCHPWR has to be defined before activating the cell. Use the command
RLSSC to define CCHPWR.
The parameter DTXU has to be defined before activating the cell. Use the command RLSSC to
define DTXU.
The cell cannot be deleted due to undefined neighbouring cells recording for the cell.
Undefined neighbouring cells recording must be stopped using the command TRTSE.
The specified channel type can not exist in the specified subcell type.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 121 of 132
Not all channel groups can be activated. Give the command again, specifying channel groups
separately.
The cell cannot be deleted due to transceiver test equipment being defined in the cell. Use
command RATTE to delete the transceiver test equipment.
56 SUPERVISION IS ACTIVE
Supervision is active for current channel type. Before a new cell can be added/removed, the
supervision must be passive. Action: Use RLVLP for printout of seizure supervision of logical
channels data.
Alarm limit greater than the maximum possible number of channels of this type in the cell.
The priority profile is not defined. The command RLPPI may be used to define the priority
profile.
The filter length and ramping length parameters are only valid when corresponding filter types
are not FIR filters ie. evaluation selection parameter must be greater than 5.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 122 of 132
The relation to an external cell must be SINGLE as it is not possible to alter data in another
BSC.
72 DISTRIBUTION IS ACTIVE
Distribution times for the message are already defined. This can be removed, along with the
message using command RLMBE.
Parameters LEVHYST, LEVTHR, PTIMTEMP and PSSTEMP are not valid for umbrella level
cells.
One or more cells are defined in the BSC. The system type parameter can not be removed when
cells are defined.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 123 of 132
The command is only valid for cells which are connected to BTS equipment which supports
GSM phase 2 System Information.
Alarm class may not be changed while an alarm is issued on specified channel type and cell.
84 NO ALARM GIVEN
A subcell type must not be specified in this command if a subcell structure is not defined for
the cell.
Channel groups containing BCCH or CBCH channels cannot be moved to the overlaid subcell.
The value of TALIM defined is only valid for an extended range cell.
Channel groups must be disconnected from the TG before deletion. Action: Use command
RXTCE to disconnect the channel group from the TG.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 124 of 132
It is not possible to remove the BCCH frequency channel with this command.
The maximum number of SDCCH and/or CBCH are already defined for this cell.
93 DESIGNATED TN IS FULL
Insufficient frequencies are available to support the specified SDCCH within the channel
group.
The value of MAXTA defined is only valid for an extended range cell.
Not enough pages due to deletion of messages. Try later (after 5 seconds).
The time slot number specified is not valid for a cell which has been defined as an extended
range cell.
The maximum number of RF channels is defined for this cell or channel group.
Channel group 0 cannot be removed with this command. The default channel group is removed
at cell deletion.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 125 of 132
The internal cell file is full. Use size alteration event number 298 to increase the size of the file.
The external cell file is full. Use size alteration event number 299 to increase the size of the
file.
The same combination of message id and message code must not be used more than once
within a cell.
The limit of 15 pages per cell has been exceeded. Existing messages may be removed by the
command RLMBE.
The page number must not be greater than the parameter NUMPAGES in command RLMBI.
If a message is to be entered in two parts the first part must be entered first. Then the second
part must be specified as package number 2.
The text type must be as defined by the parameter MODE in command RLMBI.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 126 of 132
The message is not fully defined. A page or package is yet to be entered The command
RLMBC can be used to define message text.
The cell has not been activated. The command RLSTC may be used to activate the cell.
Channel group 0 is not active. Give command RLSTC again and specify channel group 0.
Parameter CHGR must be specified when channel groups other than channel group 0 exist.
Action: Re-issue the command specifying the desired channel group.
Frequency not connected to channel group. Command RLCFI may be used to connect a
frequency to the channel group.
The subcell structure cannot be removed until the channel groups in the overlaid subcell are
removed. Command RLDGC can be used to move a channel group to the underlaid subcell or
RLDGE will delete the channel group.
It is not possible to remove the RF channel specified, as it is required to support the control
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 127 of 132
The file holding handover counter data for relations where the neighbour cell is internal is full.
Increase the file with size alteration event SAE=522.
The file holding handover counter data for relations where the neighbour cell is external is full.
Increase the file with size alteration event SAE=523.
It is not allowed to delete a priority profile while resources are connected to it. These may be
connected to other priority profiles using the command RLPRC.
It is not allowed to define the same priority profile several times. A new priority profile
designation must be given.
Too late to give more RLURI-commands when a TRTSI-command has been given to the time
supervision function.
If several RLURI-commands are given the measuring program number must be the same.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 128 of 132
The command is only valid for mixed global system type. The global system type can be
changed by command RLTYC.
The global system type is MIXED. Parameter CSYSTYPE must be used to set the cell system
type.
Parameter CSYSTYPE was given a value conflicting with the global system type. The global
system type is not MIXED. Command RLTYC may be used to change the global system type.
The cell cannot be deleted due to channel event recording for the cell. Channel event recording
must be stopped using the command RACEE.
The Global system type does not match with the cell system type in one or more cells.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 129 of 132
The given system type is not in accordance with the global system type.
Cell(s) with measurement frequencies in bands other than the global system type exists.
It is not allowed to change the data in the default priority profile or to delete it or to use it as a
name for defining a new priority profile.
The BSC MULTI BAND OPERATION MODE must be disabled for a global system type
which is not mixed.
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 130 of 132
| |
BS_PA_MFRMS | MFMRS | RLDEC
| |
CBCH INDICATOR | CBCH, Identifier | RLCCC
0 = No CBCH | NO |
1 = CBCH | YES |
| |
COMBINATION | BCCHTYPE, Identifier | RLDEC
05 = BCCH Combined | COMB, COMBC |
04 = BCCH Not Comb. | NCOMB |
| |
03 = SDCCH | SDCCH | RLCCC
| |
EXTENDED RANGE | XRANGE, Identifier | RLDEC
INDICATOR | |
1 = Extended Range | Yes |
0 = Normal | No |
| |
FILE TRANSFER TYPE | | RXPLI
00 = Conditional | UC not specified |
01 = Unconditional | UC specified |
| |
FN OFFSET | FNOFFSET | RLDEC
| |
FREQUENCY LIST,ARFCN | BCCHNO | RLDEC
| DCHNO | RLCFI
| |
FREQUENCY SPECIFIER | BCCHNO | RLDEC
| DCHNO | RLCFI
| HOP | RLCHC
| |
HSN | HSN | RLCHC
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 131 of 132
00 = Master | M | RXMOI
01 = Standalone | SA |
02 = Slave | S |
| |
TIME SLOT NUMBER | TN | RLCCC
| |
TSC | TSC | RLDTC
| bcc, part of BSIC | RLDEC
http://users.eei.ericsson.se/eeir/RGV/html/R61/commandhandling.html 01/04/2004
A Quick Ref for commandhandling of the APT 210 09 R7 (CMER6.1/BSC_POLO) Page 132 of 132