A
Packing element
Packing element
(Hydril)
Note the steel finger
inserts which strengthen
and reinforce the resilient Packing element
packing material. (Shaffer)
Natural rubber is used with
water based mud, and
working temperatures from –
35 °C to 107 °C. Neoprene rubber is
High duration and reliability. used with oil based
Identification code is R or NR muds and low
with serial number and black temperatures from – 35
color on the upper edge.
°C to 77 °C.
Nitrile rubber (synthetic
Higher duration than
components in natural natural rubber with
rubber), is used with oil better elasticity on lower
based muds or with muds temperatures than nitrile
that have oil based additives, rubbers.
and working temperatures Identification code is N
from – 7 °C to 88 °C. or CR with serial number
Identification code is S or NBR and green color on the
with serial number and red color upper edge.
on the upper edge.
They close the Ram-type
annular space outside
the string of pipe in a preventers
well or open hole, by
moving rams from a
retracted position
clear of the bore into
a position where they
close around the
pipe.
Rams operate in pairs
and seal space below
them closed.
Ram-type Pipe rams are provided
with semicircular
preventers openings which match
the diameter of the pipe
sizes for which they are
designed.
It is absolutely vital that the
pipe rams in a preventer fit
the drill pipe or tubing in the
use, and all concerned must
be certain in this regard at all
times.
If more than one size of drill
pipe is in the hole, most
operators require a second
ram preventer in the stack.
Ram-type preventers
Blank units which will close on the open hole are commonly
termed “blind” rams.
Blind rams will flatten drill pipe or tubing if they are inadvertently
closed in them, and the driller should always be certain not to
operate the blind rams when the pipe is in the hole.
Ram-type preventers were originally manually operated, but most
preventers of this type today are closed and opened by hydraulic
means, using fluid that is under 35105 Pa (500 psi) to 103105 Pa
(1500 psi) of pressure.
Most ram-type preventers are provided with screws to lock the rams
in the closed position.
Manually operated preventers are similar to hydraulic units, except
for the hydraulic cylinders.
Shaffer ram-type hydraulic blowout preventer
with automatic lock
Where:
LCSB – calculated stud length (effective thread length,
excluding end points), m
LSSB - specified stud bolt length (which is LCSB rounded
off to the nearest commercially available length), m
A=2⋅(T+0,5⋅t+d)+S
A - stud bolt length exclusive of negative length
tolerance, m
T – flange thickness, m
t – plus tolerance for flange thickness, m
d – nut thickness (equals nominal bolt
diameter), m
S – flange face standoff (for BX
assemblies it is zero), m
n – negative tolerance on bolt length :
1,5875 mm (1/16") for lengths up to 304,8
mm (12"); 3,175 mm (1/8") for lengths over
304,8 mm (12") to 457,2 mm
(18"); 6,35 mm (1/4") for lengths over
457,2 mm (18"), m
Type R and RX gaskets are
used on 6B flanges.
Only type BX gaskets are to
be used with 6BX flanges. Gasket and
RX and BX provide a groove type "R"
pressure energized seal but
are not interchangeable .
E – groove depth, m
F – groove width, m
R2 – radius in groove, m
R1 – radius in ring (octagonal
ring), m
H,B – ring height
P – standard ring or groove
diameter, m
A – width of ring, m
C – width of flat (octagonal
ring), m
Note! The pressure passage hole in the RX ring has a hole
whose centerline is located at midpoint of dimension ˝C˝.
Hole diameter is 1,524 mm (0,06 in) for rings RX-82 to RX-
85, 2,286 mm (0,09 in) for rings RX-86 and RX-87, and 3,048
mm (0,12 in) for rings RX-88 to RX-91.(10-27)
Applying actual values of initial and final pressures and volumes, the
critical values of polytrophic exponent n=1,32 and n=1,58 are
obtained.
Choke and kill manifolds
can be made to meet any
customer requirements.
Choke and kill But for optimal work, they
should consist of:
manifolds one, two or more
drilling choke system
(operated hydraulically
or manual)
manual and/
hydraulically or air
operated gate valves,
pressure transmitters,
pressure gauges,
crosses,
tees, and
a buffer tank as
required.
Choke and kill manifolds
Drilling choke system
Hydraulically actuated drilling chokes are
available in working pressures from 34,5 to 138
MPa (5000 to 20000 psi).
Inlet and outlet flange sizes from 77,8 to 103,2 mm.
The standard size of orifice is 44,5 mm (1 ¾”).
Working temperature is up to 121 °C.
Hydraulic pressure of 2 MPa (300 psi) is applied to
the actuator, which results in opening or closing the
choke.
Drilling choke system
Manually actuated drilling chokes are
available in working pressures from 34,5
to 138 MPa (5000 to 20000 psi).
Inlet and outlet flange sizes from 77,8 to
103,2 mm.
The standard size of orifice is 44,5 mm (1
¾”).
Working temperature is up to 121 °C.
Drilling choke system
Pressure transmitters,
located on the standpipe
and the choke manifold,
use actual mud pressure as
a pilot to regulate low
pressure pneumatic signals
which are transmitted
through hoses to the
control console where
pressure readings are
registered on the panel
gauges.
Gate valves
• The valves used on the
choke manifold are of
the gate valve type.
Their main parts are:
1. positive rotating seats
2. gate and seat assembly
3. solid gate
4. thrust bearings
5. threaded packing retainer
6. back-seating
7. stem pin
8. grease injection port
9. body and trim
Gate valves
• The air or
hydraulically
operated
models are
identical in
construction,
except for
the size and
pressure
rating of the
operating
cylinder.