Eyewash Pb7500
Eyewash Pb7500
Eyewash Pb7500
Instruction Manual
Ex Libris ermo83@mail.ru
Ermo
Odessa
Alfa Laval Desalt ApS
Instruction Manual
for Freshwater Generator
Type JWP-26-C801100
_-. ___
ON7947/R:OO/97.05.0I
Ermo
Odessa
Instruction Manual
for Freshwater Generator
Type J WP-26-G80/100
TABLE OF CONTENTS
System description
1.0 Working principle ............................................ 10
1.1 Freshwater quality ............................................ 10
1.2 Main components ............................................ 11
Operating instructions
1.0 Starting and stopping procedure ................................ 13
1.1 Starting ..................................................... 13
1.1.1 Evaporation ........................................... 14
1.1.2 Condensation ......................................... 14
1.2 Adjustment of hot water flow................................... 15
1.3 Adjustment of sea cooling water ................................ 16
1.4 Stopping the plant ............................................ 16
1.5 Long term standstill .......................................... 17
Maintenance
1.0 Why you need to perform regular maintenance duties.............. 18
1.1 overhaul intervals ............................................ 19
1.2 Maintenance of separator vessel ................................ 20
1.3 Maintenance of evaporator section .............................. 20
1.4 Maintenance of condenser section .............................. 22
1.5 Renewal of plate heat exchanger gaskets ........................ 24
1.5.1 Removal of old gaskets ................................. 24
1.5.2 Cleaning .............................................. 24
1.5.3 Preparation of new gaskets .............................. 25
1.5.4 Fitting new gaskets .................................... 25
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Trouble-shooting
1.0 Testsheet ................................................... 29
1.1 Trouble shooting table ........................................ 29
Spare parts
1.0 Ordering spare parts .......................................... 49
1.1 ALFA LAVAL service ......................................... 49
If you do not completely understand the information in this manual, do not hesitate
to contact your local Alfa Laval representative - or call Alfa Laval Desalt directly.
The following symbols in this manual point out safety precautions. It means your
attention is needed and your safety is involved.
Certain passages of the text will be marked with a caution mark. This
mark indicates the presence of hazard which will or can cause
property damage if the instructions are not observed
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
NOTE:
Read all safety instructions carefully and insist that they be followed by
those working with you and for you. Not following the instructions may
cause severe personal injury or damage the equipment beyond repair.
Freshwater must not be produced from polluted water, as the produced water can
be unsuitable for human consumption.
If manuals are translated to local language the unit comply with the EEC
Machinery Directive and EN 292-112 standards. For EEC land installations
manuals MUST be available in local language before installing and operating the
unit.
The unit also comply with EN 50081-2 and EN 50082-2 "Industry" with regards to
the EMC directive from EEC.
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Noise hazards
Use ear protection in noisy environments.
Crush hazards
Use correct lifting tools.
Do not work under hanging load.
Burn hazard
Wear gloves to avoid burns by hot surfaces.
Cut hazards
Wear gloves to avoid cuts by sharp edges when handling
machined parts.
NOTE:
System description
The combined brrnetarr ejector driven by the ejector pump creates a vacuum in
the system in order to lower the evaporation temperature of the feedwater.
The hot water is distributed into the remaining channels, thus transferring its heat
to the feedwater in the evaporation channels.
Having passed a demister the vapour enters every second plate channel in the
condenser section.
The sea water supplied by the combined cooling/ejector water pump distributes
itself into the remaining channels, thus absorbing the heat being transferred from
the condensing vapour.
The produced freshwater is extracted by the freshwater pump and led to the
freshwater tank.
If the salinity of the produced freshwater exceeds the chosen maximum value, the
dump valve and alarm are activated to automatically dump the produced
freshwater to the bilge.
Instruction Manual
for Freshwater Generator
Type J WP-26-C8OA00
If there are no special requirements from the authorities, the produced freshwater
can be used directly as drinking water.
MAIN COMPONENTS
1. Evaporator section
2. Separator vessel
3. Condenser section
Just like the evaporator section the condenser section consists of a plate
heat exchanger enclosed in the separator vessel.
The ejector extracts brine and incondensable gases from the separator
vessel.
5. Ejector pump
Normally, the ejector pump is delivered by Alfa Laval, and the ejector
pump is a single-stage centrifugal pump.
This pump supplies the condenser with sea water and the brinelair ejector
with jet water as well as feed water for evaporation.
Freshwater pump
Salinometer
Control panel
Operating instructions
Freshwater must not be produced from polluted water, as the produced water will
be unsuitable for human consumption.
1.1 STARTING
1. Open valves on the suction and discharge side of the ejector pump
PU-SC-01.
__
Back pressure at combined brine/air ejector outlet maximum 60 kPa
-- -
(0.6 kp/cm2.).
-/
1.I .I Evaporation
-
When there is a minimum of 90 % vacuum (after maximum 10 minutes),
The boiling temperature now rises, while the obtained vacuum drops to
approx. 85%.
1.I .2 Condensation
After approx. 3 minutes the boiling temperature will drop again, and nor-
mal vacuum is re-established.
9. Switch on salinometer
NOTE:
The freshwater pump pressure must be between 120 and 160 kPa
(1.2 - 1.6 kp/cm2.).
After starting the freshwater pump the flow sight glass must be empty.
Please refer to "FWG Order Specification" for specified hot water flow.
In order to obtain the specified flow of hot water, it is necessary to adjust the
bypass valve until desired flow is achieved.
Instruction Manual
for Freshwater Generator
Type J WP-26-C8O/lOO
The sea cooling water flow is correct, when the pressure at the inlet of the
combined aidbrine ejector is between 300 and 400 kPa (3.0 - 4.0 kp/cm2.).
7. Close valves on the suction and discharge side of the ejector pump.
If the distiller is out of operation for a period longer than 14 days, please observe
"Maintenance of separator vessel".
Instruction Manual
for Freshwater Generator
Type JWP-26-C80A00
Maintenance
The maintenance schedule on the following pages will tell you how often service
should be performed on the main components.
As the actual operating conditions of the plant are of major influence on the life
time, the overhaul dates are not obligatory but only recommended intervals.
When the plant has been in operation for a longer period of time and experience
has been established as to the actual performance, it will be possible to adapt the
maintenance schedule.
OPERATING
COMPONENT ACTION
HOURS
-=vaporator section 8000 h (or as
:lean in inhibited acid bath
required)
Separator vessel
See separator instructions
~ i t hanodes
vleasure seal ring and impeller.
2ombined
Examine mechanical shaft seal,
3jector/cooling
:ooling water pipe passage.
~ a t e rpump with
vlegger-test electric motor. Clean
notor
lump thoroughly before reassembly.
Freshwater
3xtraction pump See above
with motor
vleasure nozzles and diffusor and
Sombined airtbrine
:ompare to measurements in
ejector
echnical specification.
See "Maintenance
of salinometer See "Maintenance of salinometer type
Salinometer
typeNSl 0-MI /M2/ NS10-MI /M2/DS-20
DS-20
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
The front cover and the pressure plates for the heat exchanger sections (evapora-
tor and condenser) are made of stainless steel with a special chemical treatment.
This treatment will re-establish normal surface oxidation after work-up at the
factory. The preparation is a natural protection of the stainless steel.
NOTE!
2. Loosen the
2 nuts for P-16 distiller
4 nuts for P-26 distiller
in plate stack gradually, so that no nut is carrying the entire load alone
5. Examine plates and gaskets for possible damage, and remove damaged
plates and/or replace damaged gaskets.
6. If a defective plate is found, remove the plate together with one of the
adjacent plates.
NOTE!
10. When the evaporator section is found to be tight, close front cover and
tighten bolts.
2. Loosen the
2 nuts for P-16 distiller
6 nuts for P-26 distiller
in plate stack gradually, so that no nut is carrying the entire load alone.
4. Scrub plates with a soft brush and plain hot water at maximum 50 %.
5. Examine plates and gaskets for possible damage, and remove damaged
plates and/or replace damaged gaskets.
Instruction Manual
for Freshwater Generator
Type J WP-26-C8O/lO 0
6. If a defective plate is found, remove the plate and one of the adjacent
plates.
NOTE!
The condenser section is pressure tested by letting sea water from the
combined cooling water/ejector pump circulate through the section.
10. When the condenser section is found to be tight, close front cover and
tighten bolts.
If the gasket cannot come off directly, heat the back of the gasket groove with a
hot-air blower or butane gas burner.
You will obtain a suitable temperature, if the flame is held 10 to 15 cm behind the
plate.
1.5.2 Cleaning
Charred or loose glue and rubber remains must be removed, e.g. using a rotating
stainless steel brush. The width should be adapted (040-50 mm, width 8-10 mm).
Thin layers of glue which are difficult to remove, may remain.
Clean the gasket groove with a clean cloth, dipped in a solvent (acetone, methyl
ethyl ketone, trichlorethylene etc.).
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Gaskets, that have only loosened slightly, can be glued on. Clean gasket
groove carefully with a sharp tool. Then clean the loose part of the gasket
with emery cloth or sandpaper. Then clean groove and gasket with a
solvent, and glue.
Dry new gaskets with a clean cloth that has been slightly moistened with a solv-
ent.
Short gaskets should be stretched before being fitted into the groove.
Long gaskets should be fitted into the grooves at the plate ends first and
then gradually be pushed into the towards the middle.
During the evaporation of sea water there is always a risk of scaling on the
heating surfaces. This will lead to a reduction of the K-values of the heating
surface and decreasing freshwater production and reduction of plant efficiency.
In order to effectively prevent scaling the operators must be aware of the factors
influencing the scale formation:
If the feedwater ratio is reduced, the concentration will rise in the plant
subsequently resulting in scale formations.
Two things may shift the feedwater ratio: first of all direct adjustment of the
feedwater system, and secondly exceeding the maximum freshwater production
laid out for the plant. The operators must observe the following rules at all times.
1.2 CHEMICALDOSAGE
Use a fully soluble scale inhibitor, e.g. on polymere basis. The following products
can be recommended:
HEXAMETHAPHOSPHATE
1. Mix the required quantity for 24 hours operation in the tank according to
maker's instructions.
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
1.0 TESTSHEET
Before taking any action, please fill in a test sheet to find possible causes of
malfunctions.
Production drop due to low Foreign bodies in ejector Inspect nozzles, and clean.
vacuum (normal vacuum Blocking.
nozzles. Replace nozzles, if damaged.
above 90%).
Too high back pressure
downsteam of ejector. Max Check overboard pipe and
Production drop valves for blocking I
60 kPa (0.6 kplcm') (8.7
PSI). functionability.
Mechanical seal in
See above Replace mechanical seal.
freshwater pump defect.
Action
Max. 5% difference in
Breaking of phases. See above
amperage between phases.
Instruction Manual
for Freshwater Generator
Type J WP-26-C80A00
2. Lift motor with pump cover 4 and impeller 2 clear of pump casing 1.
Inspect the ceramic ring, the carbon ring and the spring.
It is recommended to grease the shaft and seat for the ceramic ring with
glycerine in order to make it easier to assemble the mechanical shaft seal.
Please also observe separate instructions for mechanical shaft seal
delivered together with the seal.
Inspect impeller and the drilled sealing water channel for clogging, and
clean.
1.1.1 Clearance
In connection with the inspection be sure to measure the impeller and wear ring
17 in order to secure that the clearance is no more than 0.5 mm on the diameter.
3. Carefully insert two screw drivers behind the pump shaft, and loosen it.
If the pump shaft does not come loose, use the special dismantling tools
shown below.
The tool consists of a pipe (A), a disc (B) with hole for the screw (C) and a
nut (D), washer (E).
Please note that the length L must be shorter than the length I.
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Place pipe around the shaft. Screw screw with nut and wa er into the
threaded hole (M12) on the shaft end.
5. Make sure that the pump shaft fits the motor shaft without any
obstructions, before final shaft fitting as follows:
Tap onto the end of the pump shaft with a RUBBER hammer.
NOTE!
COPVFEOI .PM4
Instruction Manual
for Freshwater Generator
Type J WP-26-C80A00
Motor with motor bracket 6, pump cover 2, and impeller 5 can now be
lifted clear of the pump casingl.
3. Remove impeller
Instruction Manual
for Freshwater Generator
Type J WP-26-C80A00
NOTE!
If not, you can fit dismantling screws into the two threaded holes in
the impeller.
4. Remove the key 26 and the mechanical seal 8 (including spring holder,
spring and carbon ring).
5. Inspect the ceramic ring, the carbon ring and the spring. Replace, if
necessary.
In order to make it easier to assemble the mechanical seal, the shaft and
ring seat may be greased with glycerine. Please also refer to separate
instructions for mechanical seal delivered together with the seal.
After fitting the ceramic ring, fit pump cover 2 to motor bracket 6.
2.1 .I Clearance
In connection with the inspection, the impeller 5 and wear rings 10 are measured
in order to secure that the clearance is not larger than stated in the diagram
below.
If the shaft 4 has to be dismantled due to a defect or if electric motor bearing has
to be replaced, proceed as follows:
3. Fit shaft 4.
4. In order to make sure that the coupling is fitted correctly, tap at the shaft
end with a RUBBER hammer.
COCNLEOI .PM4
41
Instruction Manual
for Freshwater Generator
Type J WP-26-C80A00
Frequency
CAUTION:
Protection degree
42
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Green pilot lamp should light up. LED displays the measured salinity.
If the alarm level is less than 5 ppm, the salinometer will give an alarm.
Cancel buzzer and external alarm system by switching "ALARM BUZZER" off.
Solenoid valve is not affected.
Switch "ALARM BUZZER" on as soon as the salinity is normal again; i.e. when the
red pilot lamp is off.
Instruction Manual
for Freshwater Generator
Type J WP-26-C80A00
3.3.3 Maintenance
For ordering spare parts please refer to spare parts drawing and parts list, see
"FWG Order Specification".
Instruction Manual
for Freshwater Generator
Type J WP-26-C80/100
Supply voltage
Frequency
Protection degree
2. Select correct voltage select according to the main supply voltage 115 V
or 230 VAC
1. Switch on mains.
Green pilot LED should light up. Dot. Bar displays the measured salinity.
WARNING:
If the alarm level is less than 10 ppm, the salinometer will give an alarm.
Cancel buzzer and external alarm system by switching "Sec. Alarm" off. Solenoid
valve is not affected.
Switch "Sec. Alarm" on as soon as the salinity is normal again; i.e. when the two
red LEDS is off.
4.3.3 Maintenance
CAUTION:
Spare parts
1. Serial number
2. Capacity 20 M;/2 VY
3. Designation
5. Position number
6. Article number
2. Check spare part drawing and item list with corresponding article number
to identify the item to be ordered.
The Alfa Laval group is represented in all major ports of the world.
DO NOT hesitate to contact your Alfa Laval representative if you have any
questions, problems or require spare parts.
FWG Order Snecification
IN/.: Date: BPCS: Serial no.: Page 112
JSY 97.03.05 37685 N-007947
Technical data
Type of distiller: JWP-26-C80B Capacity [rn3124h]: 20 NEINK: 60160
Power supply, rnainlcontrol Main [Volt 1 Hz]: 3 x 440/60 Control [Volt]: 220
Jacket water temperature Inlet r c ] : 79 outlet r c ] : 68,6
Jacket water flowlpressure drop Flow [rn3h]: 45 Pressure drop [bar]: 0,39
Heat consumption from jacket water [Mcalh]: 516 or [kW]: 600
Seawater temperature Met PC]: 32 outlet r c ] : 41,4
- - - -
I~lternativeheating: steam: -
Isteam flowlpressure: IFlow [kgh]: 1pressure [bar]: -
Note:
Max. inlet temperature for evaporator section must NEVER exceed 100°C (212°F)
Max. inlet pressure for condenser section must not exceed 4 bar g (400 kPa)
.Documentation
General description, freshwater generator Doc.No. 9.2.2.1
I
Flow chart, excl. options
EA FRONT COVER
EA MOTOR 71B-2 380/440V 50/60HZ
FRESHWATER PUMP
SOLENOID VALVE 1/2".
PLATE P-26 KS/ES
PLATE P-26 KE/EE
PLATE P-26 KV
PLATE P-26 KD
ORIFICE D=10,0 (FEED WATER)
PLATEP-xi KS/ES 119291-2183
PLATE P-26 KE/EE 119281-4116 TITAN/NITRIL
PLATE P-26 EV 119479-2103 TITAN/KITRIL
PLATE P-26 ED 119281-3103 TITAN/NITRIL
CLAMPING BOLT 984 58083 984 58083-03 IS0 683/13/86 ; TYPE 20A
SUPPORTING SHAFT 984 58182 984 58182-03 IS0 683/13/74 ; TIPE 11
DEMISTER 984 58034 984 58034-80
ACCESSORIES: ACCESSORIES
ELECTRICAL PANEL. 985 16565 985 16565-80
EJECTOR P W 984.10302.00 984 10337-00
EA MOMR 160M-2 380/440V 50/60HZ 985 00033-81 FOR EJECTOR PIPE'
EA FEED WATER TREATRENT, S W 985 14867 985 14867-80
EA SPARE PARTS KIT 985 16541 S P -U- U 7
I I
Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power
Technical data Doc. No. 9.2.2.2.3
Freshwater Generator JW(S)P-26-C80B Edition 96.1 0
Illustrations,indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power A
Dimensional drawing Doc. No. 9.2.2.5.1
Freshwater Generator JWP-26480 (B) Edtion 96.04
Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecificationswhen necessarv.
Alfa Laval Marine & Power
Technical data Doc. No. 9.2.2.2.4
Pump and Motor for JW(S)P-26-C80B Edition 96.10
I No. of ~ l a t e sNEINK:
Freshwater
PVVF-1532 CNL 80-80120(
Motor type
Nom. flow x pressure m3/hx mwc
Impeller size 50 Hz : mm
Impeller size 60 Hz : mm
Rotating speed 50 Hz : RPM
Rotating speed 60 Hz : RPM
3 x 380 V 50 Hz;
Rated output power kW
Consumed power kW
Current (full load) A
Current (start) A
3 x 440 V 60 Hz;
Rated output power kW
Consumed power kW
Current (full load) A
Current (start) A
3~460V60Hz: .
Rated output power
Consumed power
Current (full load)
Current (start)
iiiustrations, indicationsof material, dimensions and weights etc herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power A
Dimensional drawing Doc. No. 9.2.5.2.3
Ejector Pump CNL 80-801200 Edition 96.1 0
WEIGHT CABLE
EJECTOR PUMP MOTOR FLANGE A B (INCL. MOTOR) GLANDS
TYPE WE TYPE mm mm
Kg
CNL 80-801200 160 M MN/JIS/ANSI 827,5 (32.5') 4925 (19.4') 142 (312 Ibs) PG 29
CNL 80-80/200 160 L MN/JIS/ANSI 827,5 (325') 4925 (19.4') 151 (332 Ibs) PG 29
MECHANICAL PROTECTION INSULATION COWNG SYSTEM SHAFT SEAL POLES FOR MOTOR
IP 55 CLASS F FAN COOLED MEW. SEAL 2 POLES
0wg.no. 985 17500 R 01
Illustrat~ons,
indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power A
Technical data Doc. No. 9.2.9.3.2
Feed Water treatment 130 liter - Edtion 96.04
a
CONNECT ACCORDING TO FLOW CHART
Recommendation
Illustrations,indications of material, dimensions and weighrs erc. herein, do not wnsUrute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power A
Flow Chart Doc. No. 9.2.2.3.1
Freshwater Generator JWP-26-C80(B) Edtion 96.04
Illustrations,indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the riaht to chanae such soecifications when necessarv.
Alfa Laval Marine & Power
Equipment specification Doc. No. 9.2.2.4.1
Freshwater Generator JW(S)P-26-C80(B) Edtion 96.04
Illustrations, indicationsof material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the rioht to change such soecifications when necessarv.
ASSEMBLY SCHEME
P-26-C
FRESH WFITER
PUMP
EJECTOR PUMP
CONNECTION FOR EXTERNAL S I G N A L
MAIN SNITCH NC.
CONNECTION F O P EXTERNRL S I G N R L
MRIN SWITCH NC.
F W PUMP RUNNING NO
REMOTE S T A R T / S T O P
REMOVE JUMPER
BEFORE I N S T A L L I N G
FRESH WRTER PUMP
REMOTE STRRT/STOP
REMOVE JUMPER
BEFORE I N S T R L L l N G
EJECTOR Pump t
EXT METER
: F U L L SCRLE 2 V OC
ELECTROOE U N I T
EXTERNRL R L Q R N . N O CONTRCT
BUZZER
S O L E N O I O VALVE NO
S O L E N O I D VALVE NC
p orfepq sporejorts
pease s a enl nu ber.
BUBL glY
' U/M DESCRIPTION DRAWING NO. ARTICLE NO. MATERIAL REMARKS
SET SCREW M12 x 40 DIN 912 985 00002-15 QU- 8.8 ; DELTA-MAGNI
WASHER M12 985 32512-16 IS0 683/13/86 ; TYPE 20A
NlJl M12 DIN 934 985 00001-71 QUALITY 8 ; DELTA-MAGNI
FRONT COVER 984 58226-80
ZINC ANODE 984 58033-80
BRINE PIPE P-26-C80 984 58239-01
NON RETURN FLAP 0 50 984 35501-01
MOTOR Ml' 71 B 984 20313-00
COE~BRJEDBRINE/AIR
EJECTOR 984 12288-00
AIR VALVE 1/4" BSP 984 40939-03 BRASS
GASKET FOR FRONT COVER 984 58058-01
SEPARATOR P-26 984 58215-01
FLANGE 0 80 DIN 984 58068-03
SEAWATER PIPE FROM CONDENSER 984 58112-80
mERmmETER W/POCKET 984 30366-00
WATER HETER 985 42600-03
NON RETURN VALVE 1/2" BSP 984 35671-00 IS0 426/2/83
PRESSURE GAUGE 0-600 WA 984 30297-00
ELECTRODE FOR NS 10 984 22500-00
SAFETP VALVE 1" BSP 984 35360-00 BRASS
NON RETURN VALVE 1/T1BSP
VACUUM PIPE
FRESHWATER PIPE TO PUMP
1 50
2. EA PRESSURE PLATE 984 58024 984 58024-01
copan*Qw DW*RI(
JWP-26-C80 DIN
I ARTICLE NO. 985 16349-83
1 01 1 New drawinq in CAD k9.02.9d AJE I H J ~I EWA
T R eno .
VI - 1
i Revisim I Date I
I
Revised I Reviewed I Apptowd
I I
g ISO
27.06.84
Scale
AJ
Weigh1
Repl. fw 984.1 0230.00 rev. 01
method E
:;: drawing
rev. Repl. by rev.
BUBL QTY U/M DESCRIPTION DRAWING NO. , ARTICLE NO. KATERIAL REMARKS
PUMP H O U U G RG 5
IME'EUtER 0 116 RG 9
NtREX ENGINEERING
COPENHAGEN DENMARK
Replacement for:
DANFOSS
Replaced by:
.*a= T..^i" L Yrrh nl.l?%
BUBL QTY U/H DESCRIPTION DRAWING NO. ARTICLE NO. MATERIAL REMARKS
-
1?,. Alfa Laval SOLENOID VALVE 1/2". PRINTED:96.11.20 PAGENO. 1OF 1
Alfa Laval Separation AIS 220V 50/60 CS NO-EVSI BY : PGR DRAWING NO. 984.23482.0
Desalt Division
Copenhagen, Denmark ARTICLE NO. 984 23486-00 R: 01
d
lUBL U/n DESCRIPTION DRAWING NO. ARTICLE NO. HBTERIAL
EJECTOR HOUSING RG 5
IN'IEHEDIATE HOUSING RG 5
SET SCREW M8 X 25 HFC 1790 IS0 683/13/86 ; TYPE 20A
O-RING NnluL
NOZZLE 0 24 AISI 329
NOZZLE 0 33.4 RG 5
DIFFUSOR 0 38 RG 5
FLANGE D I N ST.00
Alfa Laval Desalt A/S BRINE/AIR EJECTOR BY : RKS DRAWING NO. 984.12200.00 R: 04
COPD(H~N m u m 24,0/33,4/38,0 DIN ARTICLE NO. 984 12288-00
-
ln
0
a.
V)
U
L
0
a
a
-
Z
0
-
I-
0
0
a
0
C x
0 P
u N
V) x
w - 0
a - -
O L W
x - I
DL QTY U/M DESCRIPTION DRAWING NO. ARTICLE NO. MATERIAL REMARKS
CONTACTOR B9 220V/50-60CS
CONTACTOR B50 220V/50-60CS
THERMAL RELAY (1.3-1.81)
THERMAL RELAY T75 (22-32)
FUSE BASE (GLASS FDSES) SAKS
FUSE BASE (DZ 11) 5SF1002-4A
FUSE BASE (DZ 11) 5SF1002-4A
FUSE CAP 5SH 202 E-27
FUSE CAP KII 5SH 112
FUSE CAP KII 5SH 112
FUSE 6A DZ I1
FUSE 6A DZ I1
ADAPTER SCREW 6A DZ
ADAPTER SCREW 6A DZ
UNIVERSAL TRANSFORMER
PILOT LAMP 240V
b: Alfa Laval
Alfa Laval Separation AIS
I ELECTRICAL PANEL. PRINTED: 96.07.31
BY : OZA
PAGE NO. 1 OF
DRAWING NO. 985 16565
3
Desalt Division
Copenhagen, Denmark ARTICLE NO. 985 16565-80 R: 01
UBL U/M DESCRIPTION DRAWING NO. ARTICLE NO. MATERIAL REMARKS
EA NUT PG 21
EA NUT PG 13,s
EA NUT PG 16
EA BLIND FI!ll'ING BL 16
EA SUSPENSION 308
EA DRAWING FILE 3080
EA DOOR STOP SZ
EA FUSE 1 A 51(25 1F3.0-1F3.1
EA SALINOETER NS 10-MI 3P2
EA CLAMP FOR SALINOMETER 3P2
EA COIL B50/B75 220V 50/60~S SPARE PARTS
BY :OZA
PAGENO. 20F
SPARE PARTS
F10216
1?,.Alfa Laval
Alfa Laval Separation AIS
Desalt Division
Copenhagen, Denmark i ELECTRICAL PANEL.
(DIAGR:985 16564 R: 00)
PRINTED: 96.07.31
BY : OZA
PAGE NO. 3 OF
DRAWING NO. 985 16565
3
I
Alfa Lavsl Desall A/S 56 M/H, 42 MWC, 3500RPH ARTICLE NO. 984 10337-00
cOWunMa( W A R K
JACKET WATER INLET
0I
- 5
4
I PARTS LIST -83 ADDED
PART UST ADDED
1961106
I
180895 CSM
I&,' PSI&
I I
JBN
I I
JBN
3 NEW PRINT; REV. 02- DISAPPERED 110895 LGR HPA HPA
1 21 MAR. FOR TANK PVC TO PE 11410941 fBJ I HJO I HJO
Recommendation 1 CORRECTlON CONCERNING ORIFICE 300694 fBJ HJO HJO
Revision Dote Revised Reviewed Approve
Use fully soluable scale inhibitor for instance on p d p e r e basis mlmlmlcwlj 'k
Mix quantity required far 24 hours' operation in tank according to
maker's instruction and adjust dosage to cover man fresh water
"" FEED WATER TREATMENT 0'
output from distiller. SCALE INHIBITOR AItm Lavd Domalt A/S
flush regulary. DOSAGE EQUIPMENT Q.owroD( oourr*
Dole
14.01.93
Dram
0 1 1 Reviewed
AX
Approved
AMS - Repl. IN 985 14867 rev. 01
Is0
melhod E
s.!ci &owing
W*l
iw"985 Repl. by 14867
rev.
Q.@ cm rct
BUBL QTY U/M DESCRIPTION DRAWING NO. ARTICLE NO. MATERIAL
--.*---
REMARKS -
FLOWMETER INCG. REG. VALVE ACRPL
NIPPLE 3/8" BSP X 1/8" BSP IS0 426/2/83 ; CU ZN39 PB3
NON RE!CURN VALVE 3/8" BSP BRASS
HOSE CONNECTION 3/8" BSP X 10 IS0 426/2/83 ; CU ZN39 PB3
HOSE CLIP sT.37
HOSE 3/8" PLASTIC
HOSE CONNECTION 1/8" BSP X 10 IS0 426/2/83 ; CU ZN39 Pi33
HOSE CONNECTION 1/2" BSP X 10 IS0 426/2/83 ; CU ZN39 PB3
EA VALVE 1/2" BSP
EA TANK 130 L
I NlREX ENGINEERING
COPENHAGEN DENMARK
checked
revised
MVF-25 - 2.5
ITEM QTY DESCRIPTION LGT DRAWING NO ARTICLE NO MATERIAL REMARKS
checked
COPENHAGEN DENMARK
revised I
Replacement for:
MV-15
Replaced by:
1265 Tutein 6 Koch 01 -13362
lUBL QTY U/H DESCRIPTION DRAWING NO. ARTICLE NO. MATERUlG
b~Alfa Laval
Aifa Laval Separation AIS
SPRING LOADED VALVE MV-15-1.0
I PRINTED: 97.03.07
BY :KHJ
PAGENO. 1OF 1
DRAWING NO. 984.35166.00
Desalt Division
Copenhagen, Denmark ARTICLE NO. 984 35166-00 R: 01
10215
- .
1 1.000000 EA .
MECH SEAL 984 10230-08 316 C/CE
FOR F.W. PUMP
1 1.000000 EA MECH. SEAL . 35 984 10724-11 316 C/CE FOR EJECrOR PUMP
h Alfa Laval
Alfa Lava1 Separation AIS
SPARE PARTS KIT
JWP-~~-C~OB
PRINTED:97.05.01 PAGENO. 1OF 1
BY : HNJ W M N G NO. 985 16541
Desalt Division
Copenhagen, Denmark
FlM15
TEST SHEET for Fresh water generator H
Vessel Date Location
Distiller serial no. Type Capacity m3/24h
-0$2
0
From mJ
a
d
Difference m5
iz Total output M 4 h
Jacket water inlet "C
Jacket water outlet 'C
.-p
d
ma
9r
(CI L,
. Difference 'C
bP Jacket water Row m5M
g2 Feed water "C
Y
0
m
7
Boiling temperature "C
Vacuum Oh
!&z
-=
a a
Boiling temperature "C
t
m
Vacuum 016
5
Steam pressure bar
Flow of steam kgM
Sea water inlet "C
55
c
V)
Sea water outlet "C
a
2 Difference "C
8 Sea water flow m5/H
Page 1 of 2
TEST SHEET for Freshwatergenerator