You are on page 1of 33

Installation Manual

for Freshwater Generator


Type JWP-26-C80B

Serial No.: NK-01211

Shipname/ Myrto
Hull No.: 1124

Build at yard: Daewoo Heavy Industries

Book Number INK-01211.fm


Alfa Laval reserve the right to make changes at any time without prior notice.

Any comments regarding possible errors and omissions or suggestions for improvement
of this publication would be gratefully appreciated.

Copies of this publication can be ordered from your local Alfa Laval company.

Published by: Alfa Laval Copenhagen A/S


Maskinvej 5
DK-2860 Søborg
(Copenhagen) Denmark

© Copyright Alfa Laval Copenhagen A/S.


This document and its content must not be copied, reproduced, transmitted or dis-
closed to any third party without consent of Alfa Laval Copenhagen A/S.

2 INK-01211.fm
Table of Contents

Safety Instructions and Warnings


1.0.0 Safety Instructions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5

Storage
1.0.0 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7

System Description
1.0.0 Working Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
1.1.0 Freshwater Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
1.2.0 Main Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9

Installation
2.0.0 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
2.1.0 Extent of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
2.2.0 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
2.3.0 Ambient Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
2.4.0 Vibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
3.0.0 General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
3.1.0 Electric Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
3.2.0 Transportation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
4.0.0 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
4.1.0 Jacket Water System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
4.2.0 Sea Water System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
4.3.0 Ejector Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
4.4.0 Brine/Cooling Water Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
4.5.0 Freshwater System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
4.6.0 Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
4.7.0 Discharge to Bilge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13

Salinometer
5.0.0 Salinometer DS-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
5.1.0 Electrode unit Cable Connection for Salinometer DS-20 . . . . . . . . . . . . . . . page 15

Index

FWG Order Specification


9.2.2.1 General description, JW(S)P-26-C80(B)/C100. . . . . . . . . . . . . . . . . . . . . page 22
9.2.2.2-3 Technical data, JW(S)P-26-C80B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24

INK-01211TOC.fm 3
Table of Contents

9.2.2.5-1 Dimensional drawing, JWP-26-C80(B). . . . . . . . . . . . . . . . . . . . . . . . . page 25


9.2.2.2-4 Technical data, Pump and Motor for JW(S)P-26-C80B . . . . . . . . . . . . page 26
9.2.5.2-3 Dimensional drawing, CNL 80-80/200 . . . . . . . . . . . . . . . . . . . . . . . . . page 27
9.2.9.3-2 Feed Water Treatment - 130 liter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 29
9.2.2.4-1 Equipment specification, JW(S)P-26-C80(B) . . . . . . . . . . . . . . . . . . . . page 31
9.2.8.1 Vertical Plant Positioning, JWP-16/26 and D-PU-(2)-36 . . . . . . . . . . . . . page 32

4 INK-01211TOC.fm
Safety Instructions and Warnings

Should you need further clarification regarding this manual, do not hesitate to con-
tact your local Alfa Laval representative - or call Alfa Laval Desalt directly.

Telephone +45 (for Denmark) 39 53 60 00


Telefax +45 (for Denmark) 39 53 65 66

1.0.0 Safety Instructions and Warnings


The following symbols in this manual point out safety precautions. It means your at-
tention is needed and your safety is involved.

WARNING

This symbol is used to indicate the presence of a hazard which can or will
cause severe personal injury, if the warning is ignored.

CAUTION

Certain passages of the text will be marked with a caution mark. This mark
indicates the presence of hazard which will or can cause property damage
if the instructions are not observed.

NOTE

This type of instruction indicates a situation which, if not avoided, could re-
sult in damage to the equipment.

It is the owner’s and operator’s responsibility to see that any person involved
with the use or operation of this equipment follow all safety instructions.

Read all safety instructions carefully and insist that they will be followed by
those working with you and for you. Not following the instructions may cause
severe personal injury or damage the equipment beyond repair.

Do not allow this equipment to be used if it is faulty or the operator does not
understand the proper use.

Samare04.fm 5
Safety Instructions and Warnings

WARNING

The freshwater generator is not to be operated in polluted water or within


20 miles from the coast

Freshwater must not be produced from polluted water, as the produced water can
be unsuitable for human consumption.

If manuals are translated to local language the unit comply with the EEC Machinery
Directive and EN 292-1/2 standards. For EEC land installations manuals MUST be
available in local language before installing and operating the unit.

The unit also comply with EN 50081-2 and EN 50082-2 “Industry” with regards to the
EMC directive from EEC.

WARNING

Noise hazards
• Use ear protection in noisy environments.

Crush hazards
• Use correct lifting tools.
• Do not work under hanging load.

Burn hazard
• Wear gloves to avoid burns by hot surfaces.

Cut hazards
• Wear gloves to avoid cuts by sharp edges when handling machined
parts.
• Wear helmet to avoid cuts by sharp edges during maintenance of the
equipment.

NOTE

• Max. ambient temperature for the equipment is 50°C (122°F).


• Min. ambient temperature for the equipment is 0°C (32°F).

6 Samare04.fm
Storage

1.0.0 Storage
Unless otherwise agreed, Alfa Laval delivers the equipment ready to be put in ser-
vice upon arrival and after installation.

However, should it be necessary to store the equipment for a longer period (1 month
or more), certain precautions should be made in order to prevent unnecessary wear
of the equipment.

Preferably, the equipment should be stored inside a room with temperature around
15°C to 20°C (59° to 68°F) and humidity around 70%.

NOTE

There should ABSOLUTELY NOT be any OZONEPRODUCING equip-


ment in the room, like electric motors or arc-welding equipment, since
ozone destroys many rubber materials (cracking).

Do not store organic solvents or acids in the room.

Avoid heat- or ultraviolet radiation.

The best solution is often to leave the equipment in the packing until it is time for in-
stallation.

In this case Alfa Laval should be informed, in order that proper preparation can be
done prior to packing.

If the equipment must be stored outdoor, the precautions mention above should be
taken as far as practical. The need for protection against the climate etc. is of course
even more important in this case.

Also, if for any reason the equipment is closed down and taken out of service for a
long period, it is advantageous to follow the advice above, even if it is not moved
from the location.

The heat exchangers, pumps, piping and the separator vessel should be DRAINED
and it is recommended to RINSE AND DRY the equipment by clean fresh water, be-
fore it is left for storage.

Storae01.fm 7
System Description

1.0.0 Working Principle


The combined brine/air ejector driven by the ejector pump creates a vacuum in the
system in order to lower the evaporation temperature of the feedwater.

The feedwater is introduced into the evaporator section through an spring loaded
valve (full open by 2 bar) orifice, and is distributed into every second plate channel
(evaporation channels).

The hot water is distributed into the remaining channels, thus transferring its heat to
the feedwater in the evaporation channels.

Having reached boiling temperature - which is lower than at atmospheric pressure -


the feed water undergoes a partial evaporation, and the mixture of generated vapour
and brine enters the separator vessel, where the brine is separated from the vapour
and extracted by the combined brine/air ejector.

Having passed a demister the vapour enters every second plate channel in the top
of the condenser section.

The sea cooling water supplied to the condenser by the combined cooling/ejector
water pump distributes itself into the remaining condenser channels, thus absorbing
the heat being transferred from the condensing vapour.

From outlet side the condenser, the sea cooling water is used as jet water for the
ejector and as feed water for evaporation.

The produced freshwater is extracted by the freshwater pump and led to the fresh-
water tank.

1.1.0 Freshwater Quality


To continuously check the actual salinity of the produced freshwater, a salinometer
is provided together with an electrode unit fitted on the freshwater pump delivery
side.

If the salinity of the produced freshwater exceeds the chosen maximum value, the
dump valve and alarm are activated to automatically dump the produced freshwater
to the bilge.

If there are no special requirements from the authorities, the produced freshwater
can be used directly as drinking water.

Sy1jwe00.fm 8
System Description

1.2.0 Main Components


The freshwater generator consists of the following components:

1. Evaporator section
The evaporator section consists of a plate heat exchanger and is enclosed in
the separator vessel.

2. Separator vessel
The separator separates the brine from the vapour.

3. Condenser section
Just like the evaporator section the condenser section consists of a plate heat
exchanger enclosed in the separator vessel.

4. Combined brine/air ejector


The ejector extracts brine and incondensable gases from the separator vessel.

5. Ejector pump
Normally, the ejector pump is delivered by Alfa Laval, and the ejector pump is
a single-stage centrifugal pump. This pump supplies the condenser with sea
cooling water and the brine/air ejector with jet water as well as feed water for
evaporation.

6. Freshwater pump
The freshwater pump is a single-stage centrifugal pump. The freshwater pump
extracts the produced freshwater from the condenser, and pumps the water to
the freshwater tank.

7. Salinometer
The salinometer continuously checks the salinity of the produced water. The
alarm set point is adjustable.

8. Control panel
Normally, the control panel is delivered by Alfa Laval. It contains motor starters,
running lights, salinometer, contacts for remote alarm and is prepared for start/
stop.

Sy1jwe00.fm 9
Installation

2.0.0 General Information

2.1.0 Extent of Delivery


The extent of delivery appears from the installation (PI-) diagram, see “FWG Order
Specification”. The distiller is delivered as a unit which can be either bolted or welded
to the floor plate.

The control panel with starters for electric motors is normally delivered separately to
be fitted on site. The salinometer is delivered built into the control panel while termi-
nals for the salinometer must be connected on site.

Please refer to installation diagram for recommended pipe dimensions.

2.2.0 Space Requirements


The space requirements are indicated on the dimensional drawings of the distiller
and ejector pump, see “FWG Order Specification”.

2.3.0 Ambient Conditions


When determining where to place the freshwater distiller in the engine room, due
consideration must be paid to a number of ambient conditions such as vibrations,
service space, allowable back pressure, and pressure loss. See also enclosed draw-
ings.

2.4.0 Vibrations
It is recommended not to place the plant in an area known to be subject to frequent
and very high vibrations.

However, under normal engine room conditions no further precautions are neces-
sary.

3.0.0 General Safety Precautions


Always handle the equipment with great care. Make sure not to damage the parts
during transportation or installation.

During erection all inlets and outlets must be covered to be protected from dirt and
particles.

Injwe03.fm 10
Installation

3.1.0 Electric Equipment


All electric installations must be carried out by a professional electrician in full accor-
dance with local regulations.

Before initial start-up

• check all connections and cables to make sure that the frequency and voltage
agrees with the electrical specifications.

WARNING

Check that all connections are properly earthened (grounded) in accor-


dance with local regulations, and properly insulated.

3.2.0 Transportation
All transportation of the equipment must be in accordance with local regulations.

The freshwater distiller must be lifted using lifting brackets as illustrated on drawing
(FWG Order Specification).

WARNING

Make sure that the straps have the required breaking strength to lift the unit
in empty condition.

See weight in dimension drawing (FWG Order Specification).

4.0.0 Installation Instructions


The distiller should be mounted according to diagram “Vertical plant positioning”,
see “FWG Order Specification”.

CAUTION

The ejector pump/motor must be mounted vertically.

The ejector pump is not self-priming and must be mounted below lowest
water line.

Pressure on suction side of ejector pump under working conditions must


be minus 0.2 bar g minimum.

Injwe03.fm 11
Installation

4.1.0 Jacket Water System


The branches for jacket water inlet and outlet to the evaporator section are marked
C3 and C4, respectively. They should be connected to the jacket water system ac-
cording to the PI-diagram, see “FWG Order Specification”.

CAUTION

A thermometer must be fitted 0.5 m from respectively branch C3 and


branch C4.

4.2.0 Sea Water System


The sea water supplied to the unit has to pass a filter (Yard supply) in the sea water
line before the ejector pump.

Fresh water generator type: Filter mesh size:


D-PU-36-C100/125 3 - 3.5 mm
JWP-36-C200 3 - 3.5 mm
JWP-26-C80/100 1 - 1.5 mm
JWP-16-C40/50 1 mm

CAUTION

Pressure on suction side of ejector pump under working conditions must be


minus 0.2 bar g minimum including pressure drop cross the filter.

The branch for sea water (cooling water) inlet to the condenser is marked C1 this
branch has to be connected to the ejector pump according to the PI-diagram.

CAUTION

A thermometer must be fitted 0.5 m from branch C1.

12 Injwe03.fm
Installation

4.3.0 Ejector Pump


The inlet and outlet pipes must be fitted according to our PI-diagram. The suction
branch B2 and the discharge branch B1 for the ejector pump have to be fitted with
reducers if necessary. Branch dimensions in accordance with pump dimensional
drawing, see “FWG Order Specification”. Inlet and outlet pipes according to installa-
tion (PI) diagram.

4.4.0 Brine/Cooling Water Discharge


Sea cooling water and brine are discharged overboard through the same pipe (B7).

Maximum back pressure 0.6 bar g (60 kPa) (0,6 kp/cm²).

CAUTION

A pressure gauge must be fitted 0.5 m from branch B7.

4.5.0 Freshwater System


The discharge branch for produced water to tank is marked D1.

• Max. back pressure according to installation (PI) diagram.

Remember to establish a drain below the distiller in case the solenoid valve opens,
e.g. due to high salinity of the produced freshwater.

4.6.0 Control Panel


The control panel is delivered for wall mounting.

4.7.0 Discharge to Bilge


Discharge branch D4. A drain from the foundation of the distiller should be made in
case of opening of the solenoid valve (High salinity of the produced water).

The distiller can as an optional extra be delivered with a return pipe. In this case it is
not necessary to make drain.

Injwe03.fm 13
Installation

CAUTION

In order to avoid malfunctions, we recommend to follow the pipe dimen-


sions indicated in our PI-diagram, see “FWG Order Specification”.

For further information please refer to the drawing “VERTICAL PLANT POSITION-
ING” drawing.

14 Injwe03.fm
Salinometer

5.0.0 Salinometer DS-20


The salinometer is normally fitted in the control panel and wired internal.

5.1.0 Electrode unit Cable Connection for Salinometer DS-20


Use a four-wire screened cable (min. 4 x 0,75 mm) for connection between the Elec-
trode unit and the control panel of the freshwater generator (or the salinometer, if
this is supplied separately).

Use five wire plugs with numbers 1 to 5 to be fastened to their respective wire and
screen as stated below, when the cable is cut to its correct length from the electrode
unit to the panel.

The cable is then to be connected to the panel according to the electrical diagram of
same.

To obtain maximal diastase from salinometer to electrode unit (20 m) 4 wires should
be arranged in the cable as shown:

Terminals example:

Wire Colors:
1. Yellow to 41 or 11 B. Four-wire cable with screen
2. White to 42 or 12 C. Wire Plugs
3. Green to 43 or 13
4. Brown to 44 or 14
5. Screen

Insale00.fm 15
Index

Numerics
9.2.2.1 General description, JW(S)P-26-C80(B)/C100 . . . . . . . . . . . . . . . . . . . . page 22
9.2.2.2-3 Technical data, JW(S)P-26-C80B . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
9.2.2.2-4 Technical data, Pump and Motor for JW(S)P-26-C80B . . . . . . . . . . . . page 26
9.2.2.4-1 Equipment specification, JW(S)P-26-C80(B) . . . . . . . . . . . . . . . . . . . . page 31
9.2.5.2-3 Dimensional drawing, CNL 80-80/200 . . . . . . . . . . . . . . . . . . . . . . . . . page 27
9.2.8.1 Vertical Plant Positioning, JWP-16/26 and D-PU-(2)-36 . . . . . . . . . . . . . page 32
9.2.9.3-2 Feed Water Treatment - 130 liter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 29

A
Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10

B
Before initial start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Brine/cooling water discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13

C
Cable Connection for Salinometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Cooling Water Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13

D
Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Discharge to bilge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13

E
Ejector pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Electric equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Electrode unit Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Extent of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10

F
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
Filter mesh size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
Freshwater quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Freshwater system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
FWG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18

G
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
General safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10

INK-01211IX.fm 16
Index
H
High salinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
HWL Order Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18

I
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11

J
Jacket water system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12

M
Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9

R
Return pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13

S
Safety instructions and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Salinometer DS-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Sea water system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8

T
Telefax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11

V
Vibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10

W
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Wire Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Working principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8

INK-01211IX.fm 17
FWG Order Specification

FWG Order Specification


INI.: Date: BPCS: Serial no.: Page 1/2
JOM 000119 10123 NK-01211

Technical data
Type of generator: JW P-26-C80B Capacity [m3/24h]: 20 NE/NK: 60/60
Pow er supply, main/control Main [Volt / Hz]: 3 x 440/60 Control [Volt]: 220
Jacket w ater temperature Inlet [°C]: 80 Outlet [°C]: 68,6
Jacket w ater flow /pressure drop Flow [m³/h]: 45,1 Pressure drop [bar] 0,43

Heat consumption from jacket w ater [Mcal/h]: 515,6 or [kW]: 600,1


Seaw ater temperature Inlet [°C]: 32 Outlet [°C]: 41,4
Seaw ater flow /pressure drop Flow [m³/h]: 49 Pressure drop [bar] 0,5

Alternative heating: steam: Capacity [m³/24h]:

Steam f low /pressure: Flow [kg/h]: Pressure [bar]:

Pump / motor data


Fresh w ater Ejector w ater Condensate pump Hot w ater

Nominel flow x pressure [ m3/h x mw c]: 1,05 x 24 49 x 42 - -


Marked output pow er [kW]: 0,75 17,8 - -
Consumed electrical pow er [kW]: 0,56 12,2 - -
Current [A]: 1,6 28,5 - -
Rotating speed [rpm]: 3360 3505 - -

Quality data
Certificate: W orkshop Connections: JIS

Extra / special equipment

Note:
Max. inlet temperature for evaporator section must NEVER exceed 100°C (212°F)
Max. inlet pressure for condenser section must not exceed 4 bar g (400 kPa)
Max. ambient temperature for freshwater generator is 50°C (122°F)

FWG-NK-01211.fm 18
FWG Order Specification

FWG Order Specification


INI: Date: BPCS no.: Serial no.: Page 2/2
JOM 000119 10123 NK-01211

Documentation
General description, freshw ater generator 9.2.2.1

Technical data, freshw ater generator 9.2.2.2.3

Dimension draw ing, freshw ater generator 9.2.2.5.1

Technical data, pump and motor 9.2.2.2.4

Dimension draw ing, ejector pump 9.2.5.2.3

Dimension draw ing, control panel 9.2.6.2.4-1

Dimension draw ing, salinometer -

Dimension draw ing, feed w ater treatment 9.2.9.3.2

Flow chart, excl. options 9.2.2.3.2

Equipmtnt specification 9.2.2.4.1

Vertical plant positioning 9.2.8.1

Electric diagram 9.2.6.3.4-1

Assembly scheme 985 16610

Spare parts, generator 985 17908-80

Spare parts, steam arrangement -

Spare parts, steam injector -

FWG-NK-01211.fm 19
SPE-NK-01211
Alfa Laval Marine & Power
9.2 Production Information 9.2.2 Freshwater Generator
JW(S)P-26-C80(B)/C100
Edition 99-01

9.2.2.1 General description, JW(S)P-26-C80(B)/C100

Application
Conversion of seawater into fresh water by vacuum distillation, for drinking, process water, and domestic use on
ships and rigs, and in small power stations. Max. salinity 2 ppm.

Capacity
The JW(S)P-26-C80(B)/C100 covers a capacity range from 4 to 35 m³/24h, depending on the heating medium and
seawater temperature. The capacities shown below are at a seawater temperature of 32°C.

Working principle
The seawater to be distilled evaporates at a temperature of about 40°C as it passes between the hot plates in the
evaporator.
This evaporating temperature corresponds to a vacuum of approximately 93% which is maintained by the brine/
air ejector.
The vapours generated pass through a demister where any drops of seawater entrained are removed and fall to
the bottom of the distiller chamber.
The vapours continue to the condenser where they condense to fresh water as they pass between the cold plates.

Basic Equipment
Titanium plate heat exchanger in evaporator and condenser.
Red brass separator and stainless steel demister, front cover and pressure plates.
Seawater pipes in CuNi.
The freshwater generator is equipped for jacket water heating and with a combined condenser cooling and ejector
water system. Furthermore the freshwater generator is equipped with dump valve, water clock, automatic feed wa-
ter regulator, combined brine/air ejector, instruments, freshwater pump with electric motor, internal piping and bed
frame.

Options
Flanges: DIN, JIS or ANSI

Power/control: 3 x 380 V 50 Hz 100/110/220 V


3 x 440 V 60 Hz 100/110/220 V
3 x 460 V 60 Hz 110 V (ul)

9.2.2.1 General description, JW(S)P-26-C80(B)/C100 Page 22


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Additional equipment necessary for operation
- Ejector pump/electric motor.
- Control panel with motorstarters and salinometer.
- Feed water treatment.

Optional equipment/design
- Steam heating systems type JWSP.
- Hot Water Loop Module for steam boosting of jacket water.
- Salinometer.
- Manual motor starters and salinometer.
- Remote start/stop.
- Water clock by-pass.
- Return pipe to brine sump.
- Electric panel build-on the unit.
- Optional spares kit for 1, 2 or 5 years of operation.
- Steel box for spares kit.
- Class test certificate.
- Freshwater treatment equipment.

9.2.2.1 General description, JW(S)P-26-C80(B)/C100 Page 23


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Production Information 9.2.2 Freshwater Generator
JW(S)P-26-C80(B)/C100
Edition 99-01

9.2.2.2-3 Technical data, JW(S)P-26-C80B

Power consumption
Ejector and freshwater pump:
NE/NK 50 Hz 60 Hz
60/60 - 70/70: 12.6 kW 12.8 kW

Pressure
bar(g) lbs/in²
Max. jacket water pressure: 4.0 58
Max. back pressure to freshwater tank: 1.3 19
Max. seawater pressure to inlet condenser: 4.0 58
Min. seawater pressure to ejector: 3.0 43
Max. back pressure at ejector outlet: 0.6 8.7
Max. back pressure for safety valve on
steam equipment: 1.0 14.5
Max. steam pressure for steam equipment: 7.0 101
Normal operation pressure for steam equipment: 2-4.5 29-65
Back pressure to condensate well for
steam equipment: 0.6-0.8 8.7-11-6

Temperature
Seawater temperature: 0-32°C Jacket water temperature: 55-95°C

Flow
Seawater flow: 49 m³/h Jacket water flow: 39-50 m³/h

Materials
Separator: Red brass
Front cover: Stainless steel
Bed frame: Steel (hot dip galvanized)
Pipe for brine discharge: Red brass
Evaporator/condenser plates: Titanium
Demister: Stainless steel
Pipe for seawater: CuNi 90/10
Pipe for fresh water: CuNi 90/10
Combined brine/air ejector housing: Red brass
Combined brine/air ejector nozzle: Stainless steel
Flange for evaporator/condenser: SG-iron (hot dip galvanized)

Steam equipment type JWSP and SP.


Pipe: Steel (hot dip galvanized)
Steam injector housing: Cast iron (painted)
Steam injector nozzle: Stainless steel

Shipping data
Freshwater generator, complete with ejector pump, electrical panel, dosing unit and standard spares.

Weight: net: 700 kg, gross: 790 kg


Dimensions: l x w x h: 2200 x 1300 x 1620 mm
Volume: 4.6 m³

9.2.2.2-3 Technical data, JW(S)P-26-C80B Page 24


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
9.29.2
Product Information
Product Information 9.2.2 Freshwater Generator
9.2.2 Freshwater Generator
Edition:
Edition: 97-01
97-01 JW(S)P-26-C80(B)/C100 JW(S)P-26-C80(B)/C100

9.2.2.5-1 Dimensional drawing, JWP-26-C80(B)

9.2.2.5-1 Dimensional drawing, JWP-26-C80(B) Page 25


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Production Information 9.2.2 Freshwater Generator
JW(S)P-26-C80(B)/C100
Edition 99-01

9.2.2.2-4 Technical data, Pump and Motor for JW(S)P-26-C80B

No. of plates NE/NK: 60/60-70/70


Pump function Freshwater Ejector
Pump Type PVVF-1532 CNL 80-80/200
Motor type 71 B 160 M
3
Nom. flow x pressure m /h x mwc 1.05 x 24 49 x 42
Impeller size 50 Hz : mm ø135 ø205
Impeller size 60 Hz : mm ø116 ø172
Rotating speed 50 Hz : RPM 2820 2905
Rotating speed 60 Hz : RPM 3360 3505
3 x 380 V 50 Hz:
Rated output power kW 0.55 15.5
Consumed power kW 0.52 12.1
Current (full load) A 1.4 28.5
Current (start) A 7 157
3 x 440 V 60 Hz:
Rated output power kW 0.75 17.8
Consumed power kW 0.56 12.2
Current (full load) A 1.6 28.5
Current (start) A 7 157
3 x 460 V 60 Hz:
Rated output power kW 0.75 17.8
Consumed power kW 0.56 12.2
Current (full load) A 1.5 27.2
Current (start) A 7 157

9.2.2.2-4 Technical data, Pump and Motor for JW(S)P-26-C80B Page 26


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Production Information 9.2.5 Ejector pump/motor

Edition 97-02

9.2.5.2-3 Dimensional drawing, CNL 80-80/200

9.2.5.2-3 Dimensional drawing, CNL 80-80/200 Page 27


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
9.2 Product Information 9.2.6 Electrical panel
Edition: 97-01

9.2.6.2-41 Dimensional drawing, Panel for Single-stage FWG (option A)

Illustrations, indications of material, dimensions and weifhts etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Product Information 9.2.9 Design/Optional/Ancillary equipment

Edition 98-01

9.2.9.3-2 Feed Water Treatment - 130 liter

9.2.9.3-2 Feed Water Treatment - 130 liter Page 29


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
9.2 Product Information 9.2.2 Freshwater Generator
Edition: 98-01 JW(S)P-26-C80(B)/C100

9.2.2.3-2 Flow Chart (incl. options), JWP-26-C80(B)

Illustrations, indications of material, dimensions and weifhts etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Product Information 9.2.2 Freshwater Generator
JW(S)P-26-C80(B)/C100
Edition 99-01

9.2.2.4-1 Equipment specification, JW(S)P-26-C80(B)

9.2.2.4-1 Equipment specification, JW(S)P-26-C80(B) Page 31


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Production Information 9.2.8 Freshwater Generator
JWP-16/26 and D-PU-(2)-36
Edition 96-04

9.2.8.1 Vertical Plant Positioning, JWP-16/26 and D-PU-(2)-36

9.2.8.1 Vertical Plant Positioning, JWP-16/26 and D-PU-(2)-36 Page 32


Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.
Alfa Laval Marine & Power
9.2 Product Information 9.2.6 Electrical panel
Edition: 99-01

9.2.6.3-41 Electrical diagram, Control panel for Single-stage FWG (option A)

Illustrations, indications of material, dimensions and weights etc. herein, do not constitute any commitment on our part.
We reserve the right to change such specifications when necessary.