Fixed Column Base Design: Eneral
Fixed Column Base Design: Eneral
Fixed Column Base Design: Eneral
GENERAL
Connection no.: 2
Connection name: Fixed column base
GEOMETRY
COLUMN
Section: SHSH 250x250x12.5
Lc = 4.00 [m] Column length
= 0.0 [Deg] Inclination angle
hc = 250 [mm] Height of column section
bfc = 250 [mm] Width of column section
twc = 13 [mm] Thickness of the web of column section
tfc = 13 [mm] Thickness of the flange of column section
rc = 13 [mm] Radius of column section fillet
Ac = 11700 [mm2] Cross-sectional area of a column
Iyc = 109150000 [mm4] Moment of inertia of the column section
Material: S355
fyc = 355.00 [MPa] Resistance
fuc = 490.00 [MPa] Yield strength of a material
COLUMN BASE
lpd = 500 [mm] Length
bpd = 500 [mm] Width
mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 2 of 5
ANCHORAGE
The shear plane passes through the UNTHREADED portion of the bolt.
Class = 8.8 Anchor class
fyb = 640.00 [MPa] Yield strength of the anchor material
fub = 800.00 [MPa] Tensile strength of the anchor material
d= 30 [mm] Bolt diameter
As = 561 [mm2] Effective section area of a bolt
Av = 707 [mm2] Area of bolt section
nH = 4 Number of bolt columns
nV = 4 Number of bolt rows
Horizontal spacing eHi = 130;130 [mm]
Vertical spacing eVi = 130;130 [mm]
Anchor dimensions
L1 = 50 [mm]
L2 = 600 [mm]
L3 = 50 [mm]
Anchor plate
lp = 130 [mm] Length
bp = 130 [mm] Width
tp = 10 [mm] Thickness
Material: S355
fy = 355.00 [MPa] Resistance
Washer
lwd = 60 [mm] Length
bwd = 60 [mm] Width
twd = 8 [mm] Thickness
MATERIAL FACTORS
M0
= 1.00 Partial safety factor
M2 = 1.25 Partial safety factor
C = 1.50 Partial safety factor
SPREAD FOOTING
L= 900 [mm] Spread footing length
B= 1200 [mm] Spread footing width
H= 1200 [mm] Spread footing height
Concrete
Class C40
fck = 40.00 [MPa] Characteristic resistance for compression
Grout layer
tg = 25 [mm] Thickness of leveling layer (grout)
fck,g = 40.00 [MPa] Characteristic resistance for compression
Cf,d = 0.20 Coeff. of friction between the base plate and concrete
mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 3 of 5
WELDS
ap = 8 [mm] Footing plate of the column base
LOADS
Case: Manual calculations.
RESULTS
COMPRESSION ZONE
COMPRESSION OF CONCRETE
fcd = 26.67 [MPa] Design compressive resistance EN 1992-1:[3.1.6.(1)]
fj = 36.95 [MPa] Design bearing resistance under the base plate [6.2.5.(7)]
c = tp (fyp/(3*fj* M0))
c= 45 [mm] Additional width of the bearing pressure zone [6.2.5.(4)]
beff = 102 [mm] Effective width of the bearing pressure zone under the flange [6.2.5.(3)]
leff = 339 [mm] Effective length of the bearing pressure zone under the flange [6.2.5.(3)]
Ac0 = 34619 [mm2]
Area of the joint between the base plate and the foundation EN 1992-1:[6.7.(3)]
Ac1 = 311572 [mm2] Maximum design area of load distribution EN 1992-1:[6.7.(3)]
Frdu = Ac0*fcd* (Ac1/Ac0) ≤ 3*Ac0*fcd
Frdu = 2769.53 [kN] Bearing resistance of concrete EN 1992-1:[6.7.(3)]
j
= 0.67 Reduction factor for compression [6.2.5.(7)]
fjd = j*Frdu/(beff*leff)
fjd = 53.33 [MPa] Design bearing resistance [6.2.5.(7)]
SHEAR
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE
Shear force Vj,Ed,y
d,y = 0.57 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
b,y = 0.57 Coeff. for resistance calculation F1,vb,Rd [Table 3.4]
mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 4 of 5
k1,y = 2.50 Coeff. taking account of the bolt position - perpendicularly to the direction of shear [Table 3.4]
F1,vb,Rd,y = k1,y* b,y*fup*d*tp / M2
F1,vb,Rd,y = 421.09 [kN] Resistance of an anchor bolt for bearing pressure onto the base plate [6.2.2.(7)]
d,z
= 0.57 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
=
b,z 0.57
Coeff. for resistance calculation F1,vb,Rd [Table 3.4]
k1,z = 2.50 Coeff. taking account of the bolt position - perpendicularly to the direction of shear [Table 3.4]
F1,vb,Rd,z = k1,z* b,z*fup*d*tp / M2
F1,vb,Rd,z = 421.09 [kN] Resistance of an anchor bolt for bearing pressure onto the base plate [6.2.2.(7)]
SPLITTING RESISTANCE
Cf,d = 0.20 Coeff. of friction between the base plate and concrete [6.2.2.(6)]
Nc,Ed = 1200.00 [kN] Compressive force [6.2.2.(6)]
Ff,Rd = Cf,d*Nc,Ed
Ff,Rd = 240.00 [kN] Slip resistance [6.2.2.(6)]
SHEAR CHECK
Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z ≤ 1,0 0.71 < 1.00 verified (0.71)
WEAKEST COMPONENT:
ANCHOR BOLT - SHEAR - WITH LEVER ARM
mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 5 of 5
mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015