0818 Pressure Sensors DB GB Internet
0818 Pressure Sensors DB GB Internet
0818 Pressure Sensors DB GB Internet
Pressure sensors
Grundfos Direct Sensors™
Pressure sensors
1. Product overview 4
Table of contents
2. Product introduction 5
8. Product range 55
RPI transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DPI II and DPI II+T transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
DPI I transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
RPS and DPS sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2
Pressure sensors
9. Accessories 58
Table of contents
SI power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
M12 cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Capillary tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Adapter for Grundfos CR pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Snap-on cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
SI converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
10. Appendix 60
Installation of RPI and DPI II transmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
3
Pressure sensors
1
1. Product overview
Product overview
This data booklet is for the latest version of Grundfos Direct Sensors™. Customers already buying Grundfos Direct
Sensors™ might be buying a sensor with another specification
RPI
Pressure range: 0 - 0.6 to 25 bar (0 - 8.7 to 363 psig)
System pressure range: Maximum 30 bar (453 psig)
Relative Pressure transmitter, Industry System temperature: -30 to +120 °C (-22 to +248 °F)
• stainless-steel housing. Signal: 4-20 mA (2-wire)
Power supply: 12.5 - 30 VDC
Enclosure class: IP67
DPI
Differential pressure range: 0 - 0.6 to 10 bar (0 - 8.7 to 145 psid)
System pressure: Maximum 30 bar (453 psig)
Differential Pressure transmitter, Industry
System temperature: -10 to +70 °C (14 to 158 °F)
• conventional sensor with two capillaries
Signal: 4-20 mA (3-wire)
• stainless-steel and composite housing.
Power supply: 12-30 VDC
Enclosure class: IP55
DPI II
Differential pressure range: 0 - 0.6 to 16 bar (0 - 8.7 to 232 psid)
System pressure: Maximum 30 bar (453 psig)
Differential Pressure transmitter, Industry
System temperature: -30 to +120 °C (-22 to +248 °F)
• G 1/2 connection and one capillary
Signal: 4-20 mA (2-wire)
• stainless-steel housing.
Power supply: 12.5 - 30 VDC
Enclosure class: IP67
DPI II+T Differential pressure range: 0 - 0.6 to 16 bar (0 - 8.7 to 232 psid)
Temperature range: 0-120 °C (32-248 °F)
Differential Pressure transmitter, Industry
System pressure: Maximum 30 bar (453 psig)
• G 1/2 connection and one capillary
System temperature: -30 to +120 °C (-22 to +248 °F)
• combined pressure and temperature measurement
Signal: 2 x 0-10 VDC (4-wire)
• stainless-steel housing.
Power supply: 12.5 - 30 VDC
Enclosure class: IP67
4
Pressure sensors
2
2. Product introduction
Product introduction
This data booklet describes these Grundfos products: Differential-pressure sensor
• industrial relative- and differential-pressure sensors The central part of a differential-pressure sensor is a
• standard relative- and differential-pressure sensors. chip which transforms the differential pressure into
electrical signals. The difference between the two
system pressures on either side of the chip, called the
differential pressure, causes the chip to warp. This is
registered as a change of resistance in the strain
gauges of a Wheatstone bridge. The change in
5
Pressure sensors
3
[bar] [psig]
0 - 0.6 0 - 8.7
0 - 1.0 0 - 14.5
0 - 1.6 0 - 23.2
Applications
• Pump control
• HVAC systems
• temperature control and chiller systems
• renewable energies such as heat pumps, solar
thermals, fresh water and micro-CHP systems
• monitoring and control systems
• water treatment plants
• water utility and distribution systems
• HPC and IT cooling systems.
6
Pressure sensors
3
Electrical connections
RPI
Signal condition: 2-wire (loop-powered)
Pin 1 2 3 4
RPI+T
Signal condition: 4-wire
Pin 1 2 3 4
Directives
The Grundfos Direct Sensors™ are in conformity
with these council directives on the approximation of
the laws of the EC member states:
• • Low Voltage Directive (2014/35/EU)
– Standards used: EN 61010-1:2010
• EMC Directive (2014/30/EU).
– Standards used: EN 61326-1:2013 and EN
61326-2-3:2013
The GRUNDFOS Direct Sensors™ are exempted from
the Pressure Equipment Directive (PED) according to
Article 4, paragraph 3 in the PED 2014/68/EU.
7
Pressure sensors
3
RPI and RPI+T, 0 - 0.6 bar (0 - 8.7 Specifications
Relative Pressure transmitters, Industry (RPI and RPI+T)
psig) Pressure
Measuring range 0 - 0.6 bar (0 - 8.7 psig)
Accuracy (± 1 σ),
± 2 % FS
0-80 °C (32-176 °F)
Accuracy (± 1 σ),
± 2.5 % FS
-30 to +100 °C (-22 to +212 °F)
Less than 100 ms
Response time
(typically 50 ms)
10V
Environmental standards
Enclosure class IP67, cable-connected
Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
8
Pressure sensors
3
RPI and RPI+T, 0 - 1.0 bar (0 - 14.5 Specifications
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max
Corrosion-resistant coating
Fig. 11 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
10V Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
9
Pressure sensors
3
RPI and RPI+T, 0 - 1.6 bar (0 - 23.2 Specifications
Relative Pressure transmitters, Industry (RPI and RPI+T)
psig) Pressure
Measuring range 0 - 1.6 bar (0 - 23.2 psig)
Accuracy (± 1 σ),
± 2 % FS
0-80 °C (32-176 °F)
Accuracy (± 1 σ),
± 2.5 % FS
-30 to +100 °C (-22 to +212 °F)
Less than 100 ms
Response time
(typically 50 ms)
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 -to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max
Corrosion-resistant coating
Fig. 15 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
10V Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
10
Pressure sensors
3
RPI and RPI+T, 0 - 2.5 bar (0 - 36.3 Specifications
0
0 P max
T max
11
Pressure sensors
3
RPI and RPI+T, 0 - 4.0 bar (0 - 58.0 Specifications
Relative Pressure transmitters, Industry (RPI and RPI+T)
psig) Pressure
Measuring range 0 - 4.0 bar (0 - 58.0 psig)
Accuracy (± 1 σ),
± 2 % FS
0-80 °C (32-176 °F)
Accuracy (± 1 σ),
± 2.5 % FS
-30 to +100 °C (-22 to +212 °F)
Less than 100 ms
Response time
(typically 50 ms)
0
0 P max
T max
12
Pressure sensors
3
RPI and RPI+T, 0 - 6.0 bar (0 - 87.0 Specifications
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max Corrosion-resistant coating
Fig. 27 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
Temperature cycling IEC 68-2-14
10V
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
13
Pressure sensors
3
RPI and RPI+T, 0 - 10.0 bar (0 - Specifications
Relative Pressure transmitters, Industry (RPI and RPI+T)
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max Corrosion-resistant coating
Fig. 31 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
Temperature cycling IEC 68-2-14
10V
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
14
Pressure sensors
3
RPI and RPI+T, 0 - 16.0 bar (0 - Specifications
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max
Corrosion-resistant coating
Fig. 35 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
10V Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
15
Pressure sensors
3
RPI+T2, 0 - 16.0 bar (0 - 232.1 psig) Specifications
Relative Pressure transmitters, Industry (RPI and RPI+T)
Pressure
Measuring range 0 - 16.0 bar (0 - 232.1 psig)
Accuracy (± 1 σ),
± 2 % FS
0-80 °C (32-176 °F)
Accuracy (± 1 σ),
± 2.5 % FS
-30 to +120 °C (-22 to +248 °F)
Less than 100 ms
16
Pressure sensors
3
RPI and RPI+T, 0 - 25.0 bar (0 - Specifications
Ambient temperature,
-25 to +60 °C (-13 to +140 °F)
operation
Storage temperature -55 to +70 °C (-67 to +158 °F)
TM04 9237 3510
Materials
Sensing element Silicon-based MEMS
Sealing EPDM or FKM
Housing Stainless steel 1.4404 (AISI 316 L)
P max
Corrosion-resistant coating
Fig. 43 Pressure response, RPI Wetted materials EPDM or FKM
Stainless steel 1.4404 (AISI 316 L)
Environmental standards
Enclosure class IP67, cable connected
10V Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
TM06 3359 1716
0
0 P max
T max
17
Pressure sensors
4
+ 75
CE C, CSA, US EAC
Technical overview
The DPI differential-pressure transmitter from
Grundfos Direct Sensors™ is designed for industrial
purposes.
The DPI transmitter is fully compatible with aqueous
media. The sensor is based on MEMS sensing
technology in combination with the corrosion-resistant
Silicoat® coating technology on the sensor chip.
This makes the DPI transmitter very robust and ideal
for pump integration and monitoring in harsh
environments.
Applications
• Pump control
• HVAC systems
18
Pressure sensors
4
DPI, 0 - 0.6 bar (0 - 8.7 psid) Specifications
P2
E
Materials
P1
Sensing element Silicon-based MEMS
O-ring FKM
C
Housing Stainless steel 1.4305 (AISI 303)
A B Wetted materials FKM, PPS and 1.4305
Fig. 48 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77 Immunity EN 61000-6-2
UNF
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 49 Differential-pressure response, DPI
19
Pressure sensors
4
DPI, 0 - 1.0 bar (0 - 14.5 psid) Specifications
Differential Pressure transmitter, Industry (DPI I)
Pressure
Measuring range 0 - 1.0 bar (0 - 14.5 psid)
Accuracy (IEC 61298-2) 2 % FS
Response time Less than 0.5 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
System conditions and environment
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C
O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 51 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 52 Differential-pressure response, DPI
20
Pressure sensors
4
DPI, 0 - 1.2 bar (0 - 17.4 psid) Specifications
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 54 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 55 Differential-pressure response, DPI
21
Pressure sensors
4
DPI, 0 - 1.6 bar (0 - 23.2 psid) Specifications
Differential Pressure transmitter, Industry (DPI I)
Pressure
Measuring range 0 - 1.6 bar (0 - 23.2 psid)
Accuracy (IEC 61298-2) 2 % FS
Response time Less than 0.5 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
System conditions and environment
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C
O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 57 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 58 Differential-pressure response, DPI
22
Pressure sensors
4
DPI, 0 - 2.5 bar (0 - 36.3 psid) Specifications
P2
E
Materials
P1
Sensing element Silicon-based MEMS
O-ring FKM
C
Housing Stainless steel 1.4305 (AISI 303)
A B Wetted materials FKM, PPS and 1.4305
Fig. 60 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 61 Differential-pressure response, DPI
23
Pressure sensors
4
DPI, 0 - 4.0 bar (0 - 58.0 psid) Specifications
Differential Pressure transmitter, Industry (DPI I)
Pressure
Measuring range 0 - 4.0 bar (0 - 58.0 psid)
Accuracy (IEC 61298-2) 2 % FS
Response time Less than 0.5 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
System conditions and environment
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C
O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 63 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77 Immunity EN 61000-6-2
UNF
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 64 Differential-pressure response, DPI
24
Pressure sensors
4
DPI, 0 - 6.0 bar (0 - 87.0 psid) Specifications
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C
O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 66 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 67 Differential-pressure response, DPI
25
Pressure sensors
4
DPI, 0 - 10.0 bar (0 - 145.0 psid) Specifications
Differential Pressure transmitter, Industry (DPI I)
Pressure
Measuring range 0 - 10.0 bar (0 - 145.0 psid)
Accuracy (IEC 61298-2) 2 % FS
Response time Less than 0.5 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
P2
E
Materials
P1
Sensing element Silicon-based MEMS
C O-ring FKM
Housing Stainless steel 1.4305 (AISI 303)
A B
Wetted materials FKM, PPS and 1.4305
Fig. 69 Dimensions, DPI Environmental standards
Enclosure class IP55
A B C D E F Temperature cycling IEC 68-2-14
7/16 - 20 Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
mm 14 6 ∅45 77
UNF Immunity EN 61000-6-2
SW 14
0.25" Emission EN 61000-6-3
in 0.55 0.24 ∅1.77 3.03
flare Weight 550 g (1.21 lbs)
Output signals
TM06 3358 1716
P max
Fig. 70 Differential-pressure response, DPI
26
Pressure sensors
5
[bar] [psid]
0 - 0.6 0 - 8.7
0 - 1.0 0 - 14.5
0 - 1.6 0 - 23.2
0 - 2.5 0 - 36.3
0 - 4.0 0 - 58.0
Applications
• Pump control
• HVAC systems
• temperature control and chiller systems
• renewable energies such as heat pumps, solar
thermals, fresh water and micro-CHP systems
• monitoring and control systems
• water treatment plants
• water utility and distribution systems
• HPC and IT cooling systems.
27
Pressure sensors
5
Electrical connections
Differential Pressure transmitter, Industry
2 1
3 4
DPI II
Signal condition: 2-wire (loop-powered)
Pin 1 2 3 4
DPI II+T
Signal condition: 4-wire
Pin 1 2 3 4
Directives
The Grundfos Direct Sensors™ are in conformity
with these council directives on the approximation of
the laws of the EC member states:
• Low Voltage Directive (2014/35/EU)
– Standards used: EN 61010-1:2010
• EMC Directive (2014/30/EU).
– Standards used: EN 61326-1:2013 and EN
61326-2-3:2013
The GRUNDFOS Direct Sensors™ are exempted from
the Pressure Equipment Directive (PED) according to
Article 4, paragraph 3 in the PED 2014/68/EU.
28
Pressure sensors
5
DPI II and DPI II+T, 0 - 0.6 bar (0 - Specifications
0
0 P max
T max
29
Pressure sensors
5
DPI II and DPI II+T, 0 - 1.0 bar (0 - Specifications
Differential Pressure transmitter, Industry
0
0 P max
T max
30
Pressure sensors
5
DPI II and DPI II+T, 0 - 1.6 bar (0 - Specifications
0
0 P max
T max
31
Pressure sensors
5
DPI II and DPI II+T, 0 - 2.5 bar (0 - Specifications
Differential Pressure transmitter, Industry
0
0 P max
T max
32
Pressure sensors
5
DPI II and DPI II+T, 0 - 4.0 bar (0 - Specifications
0
0 P max
T max
33
Pressure sensors
5
DPI II and DPI II+T, 0 - 6.0 bar (0 - Specifications
Differential Pressure transmitter, Industry
0
0 P max
T max
34
Pressure sensors
5
DPI II and DPI II+T, 0 - 10.0 bar (0 - Specifications
0
0 P max
T max
35
Pressure sensors
5
DPI II and DPI II+T, 0 - 16.0 bar (0 - Specifications
Differential Pressure transmitter, Industry
0
0 P max
T max
36
Pressure sensors
6
[bar] [psig]
0 - 0.6 0 - 8.7
0 - 1.0 0 - 14.5
0 - 1.6 0 - 23.2
Applications
• Pump control + 75
• HVAC systems CE C, CSA, US EAC
• temperature control and chiller systems
• renewable energies such as heat pumps, solar
thermals, fresh water and micro-CHP systems
• monitoring and control systems
• water treatment plants
• water utility and distribution systems
• HPC and IT cooling systems.
37
Pressure sensors
6
Electrical connections
Relative Pressure sensor Standard, RPS
Electrical
connector
1 2 3 4 Pin No 1 2 3 4
Temperature signal
V Pressure signal 3Y
V 5Y
PE PE
Description Description
Pin Colour
Analogue signal Digital signal
1 Temperature signal Rx Yellow
2 Pressure signal Tx White
3 GND, 0 V PELV GND, 0 V PELV Green
4 Voltage supply, +5 VDC Power supply, +5 VDC Brown
Options
TM06 6670 2016
TM06 6671 2016
Description
1/2'' nipple, stainless steel (316L)
Differential Temperature
The differential temperature is between two standard
Direct SensorsTM from GRUNDFOS.
Directives
The Grundfos Direct Sensors™ are in conformity
with these council directives on the approximation of
the laws of the EC member states:
• Low Voltage Directive (2014/35/EU)
– Standards used: EN 61010-1:2010
• EMC Directive (2014/30/EU).
– Standards used: EN 61326-1:2013 and EN
61326-2-3:2013
The GRUNDFOS Direct Sensors™ are exempted from
the Pressure Equipment Directive (PED) according to
Article 4, paragraph 3 in the PED 2014/68/EU.
38
Pressure sensors
6
RPS, 0 - 0.6 bar (0 - 8.7 psig) Specifications
0.5
0.0
0 120
T max =
peak temperature
39
Pressure sensors
6
RPS, 0 - 1.0 bar (0 - 14.5 psig) Specifications
Relative Pressure sensor Standard, RPS
Pressure
Measuring range 0 - 1.0 bar (0 - 14.5 psig)
Accuracy (± 1 σ),
± 1.5 % FS
15-90°C (59-194°F)
Accuracy (± 1 σ),
± 2 % FS
0-120 °C (32-248 °F)
Response time Less than 1 s
Resolution 0.6 mbar (0.009 psig)
Temperature
Measuring range 0-120 °C (32-248 °F)
Accuracy (± 1 σ),
± 0.5 K
15-90 °C (59-194 °F)
Accuracy (± 1 σ),
±1K
0-120 °C (32-248 °F)
Electrical data
5 VDC (± 5 %), PELV
A F Power supply Grounding of sensor supply
required.
G
Output signals Ratiometric
Fig. 113 Dimensions, RPS Digital output signals Grundfos open data protocol
0.5-3.5 V for pressure
(zero at 0.5 V)
A B C D E F G Analog output signals
0.5-4.1 V for temperature
mm 4.5 53.7 27 20 39.9 10.2 14.8 (zero at 0.5 V and 100 °C at 3.5 V)
in 0.18 2.11 1.06 0.79 1.57 0.40 0.58 Power consumption Appr. 75 mW
Load impedance > 47 kΩ
Output signals Maximum cable length 3 m (9.10 ft)
Materials
[V] Sensor Silicon-based MEMS
EPDM O-rings, FKM O-rings or
Pressure output signal
EPDM or FKM
Wetted materials
Adapter ISO 7/1 - R1/2" and NPT 1/
2" EN 1.4408 (AISI 316)
Environmental standards
P max
Enclosure class IP44, cable connected
Fig. 114 Pressure response in Analogue mode Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
[V] Electromagnetic compatibility EN 61326-1
Temperature output signal
4.5
4.0
3.5
3.0
2.5
2.0
1.5
TM06 3354 5214
1.0
0.5
0.0
0 120
T max =
peak temperature
Fig. 115 Temperature response in Analogue mode
40
Pressure sensors
6
RPS, 0 - 1.6 bar (0 - 23.2 psig) Specifications
0.5
0.0
0 120
T max =
peak temperature
41
Pressure sensors
6
RPS, 0 - 2.5 bar (0 - 36.3 psig) Specifications
Relative Pressure sensor Standard, RPS
Pressure
Measuring range 0 - 2.5 bar (0 - 36.3 psig)
Accuracy (± 1 σ),
± 1 % FS
15-90°C (59-194°F)
Accuracy (± 1 σ),
± 1.5 % FS
0-120 °C (32-248 °F)
Response time Less than 1 s
Resolution 0.6 mbar (0.009 psig)
Temperature
Measuring range 0-120 °C (32-248 °F)
Accuracy (± 1 σ),
± 0.5 K
15-90 °C (59-194 °F)
A Electrical data
F
5 VDC (± 5 %), PELV
G Power supply Grounding of sensor supply
required.
Fig. 121 Dimensions, RPS Output signals Ratiometric
Digital output signals Grundfos open data protocol
0.5-3.5 V for pressure
A B C D E F G
(zero at 0.5 V)
Analog output signals
mm 4.5 53.7 27 20 39.9 10.2 14.8 0.5-4.1 V for temperature
in 0.18 2.11 1.06 0.79 1.57 0.40 0.58 (zero at 0.5 V and 100 °C at 3.5 V)
Power consumption Appr. 75 mW
Output signals Load impedance > 47 kΩ
Maximum cable length 3 m (9.10 ft)
[V] Materials
Sensor Silicon-based MEMS
Pressure output signal
0.5
0.0
0 120
T max =
peak temperature
42
Pressure sensors
6
RPS, 0 - 4.0 bar (0 - 58.0 psig) Specifications
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
TM06 3354 5214
0.5
0.0
0 120
T max =
peak temperature
43
Pressure sensors
6
RPS, 0 - 6.0 bar (0 - 87.0 psig) Specifications
Relative Pressure sensor Standard, RPS
Pressure
Measuring range 0 - 6.0 bar (0 - 87.0 psig)
Accuracy (± 1 σ),
± 1 % FS
15-90°C (59-194°F)
Accuracy (± 1 σ),
± 1.5 % FS
0-120 °C (32-248 °F)
Response time Less than 1 s
Resolution 0.6 mbar (0.009 psig)
Temperature
Measuring range 0-120 °C (32-248 °F)
Accuracy (± 1 σ),
± 0.5 K
15-90 °C (59-194 °F)
A Electrical data
F
5 VDC (± 5 %), PELV
G Power supply Grounding of sensor supply
required.
Fig. 129 Dimensions, RPS Output signals Ratiometric
Digital output signals Grundfos open data protocol
0.5-3.5 V for pressure (zero at 0.5 V)
A B C D E F G
Analog output signals 0.5-4.1 V for temperature
mm 4.5 53.7 27 20 39.9 10.2 14.8 (zero at 0.5 V and 100 °C at 3.5 V)
in 0.18 2.11 1.06 0.79 1.57 0.40 0.58 Power consumption Appr. 75 mW
Load impedance > 47 kΩ
Output signals Maximum cable length 3 m (9.10 ft)
Materials
[V]
Sensor Silicon-based MEMS
EPDM O-rings, FKM O-rings or
Sealing
Pressure output signal
Wetted materials
Adapter ISO 7/1 - R1/2" and NPT 1/
2" EN 1.4408 (AISI 316)
Environmental standards
P max
Enclosure class IP44, cable connected
Temperature cycling IEC 68-2-14
Fig. 130 Pressure response in Analogue mode Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
[V]
Temperature output signal
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
TM06 3354 5214
0.5
0.0
0 120
T max =
peak temperature
44
Pressure sensors
6
RPS, 0 - 10.0 bar (0 - 145.0 psig) Specifications
A Electrical data
F
5 VDC (± 5 %), PELV
G Power supply
Grounding of sensor supply required.
Output signals Ratiometric
Fig. 133 Dimensions, RPS Digital output signals Grundfos open data protocol
0.5-3.5 V for pressure (zero at 0.5 V)
Analog output signals 0.5-4.1 V for temperature
A B C D E F G
(zero at 0.5 V and 100 °C at 3.5 V)
mm 4.5 53.7 27 20 39.9 10.2 14.8 Power consumption Appr. 75 mW
in 0.18 2.11 1.06 0.79 1.57 0.40 0.58 Load impedance > 47 kΩ
Maximum cable length 3 m (9.10 ft)
Output signals
Materials
[V] Sensor Silicon-based MEMS
EPDM O-rings, FKM O-rings or
Sealing
Pressure output signal
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
TM06 3354 5214
0.5
0.0
0 120
T max =
peak temperature
45
Pressure sensors
6
RPS, 0 - 16.0 bar (0 - 232.1 psid) Specifications
Relative Pressure sensor Standard, RPS
Pressure
Measuring range 0 - 16.0 bar (0 - 232.1 psid)
Accuracy (± 1 σ),
± 1 % FS
15-90°C (59-194°F)
Accuracy (± 1 σ),
± 1.5 % FS
0-120 °C (32-248 °F)
Response time Less than 1 s
Resolution 0.6 mbar (0.009 psig)
Temperature
Measuring range 0-120 °C (32-248 °F)
Accuracy (± 1 σ),
± 0.5 K
15-90 °C (59-194 °F)
Sealing
EPDM sealing cap with FKM O-rings
Housing Composite, PPS
Corrosion-resistant coating, PPS,
TM06 3360 5214
EPDM or FKM
Wetted materials
Adapter ISO 7/1 - R1/2" and NPT 1/
2" EN 1.4408 (AISI 316)
Environmental standards
P max Enclosure class IP44, cable connected
Fig. 138 Pressure response in Analogue mode Temperature cycling IEC 68-2-14
Vibration, non-destructive 20-2000 Hz, 10 G, 4 h
Electromagnetic compatibility EN 61326-1
[V]
Temperature output signal
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
TM06 3354 5214
0.5
0.0
0 120
T max =
peak temperature
46
Pressure sensors
7
Certificates
• renewable energies such as heat pumps, solar Fig. 141 Electrical connections
thermals, fresh water and micro-CHP systems
• monitoring and control systems Description Description
Pin Colour
• water treatment plants Analogue signal Digital signal
Pressure range
Pressure range
[bar] [psid]
0 - 0.6 0 - 8.7
0 - 1.0 0 - 14.5
0 - 1.6 0 - 23.2
0 - 2.5 0 - 36.3
0 - 4.0 0 - 58.0
0 - 6.0 0 - 87.0
47
Pressure sensors
7
Options
Differential Pressure sensor Standard, DPS
Part
Fitting, 6 mm (0.23")
Tube fitting
Fitting, 8 mm (0.31")
1.4408
(AISI 316)
Fitting, 6 mm (0.23") Compression
Fitting, 8 mm (0.31") fitting
Differential Temperature
The differential temperature is between two standard
Direct SensorsTM from Grundfos.
Directives
The Grundfos Direct Sensors™ are in conformity
with these council directives on the approximation of
the laws of the EC member states:
• Low Voltage Directive (2014/35/EU)
– Standards used: EN 61010-1:2010
• EMC Directive (2014/30/EU).
– Standards used: EN 61326-1:2013 and
EN 61326-2-3:2013
The GRUNDFOS Direct Sensors™ are exempted from
the Pressure Equipment Directive (PED) according to
Article 4, paragraph 3 in the PED 2014/68/EU.
48
Pressure sensors
7
DPS, 0 - 0.6 bar (0 - 8.7 psid) Specifications
Liquid types
wetted materials
Liquid temperature, operation 0-120 °C (32-248 °F)
TM06 3455 0115
49
Pressure sensors
7
DPS, 0 - 1.0 bar (0 - 14.5 psid) Specifications
Differential Pressure sensor Standard, DPS
Pressure
Measuring range 0 - 1.0 bar (0 - 14.5 psid)
Accuracy (± 1 σ), in water,
± 1.5 % FS
15-90 °C (59-194 °F)
Accuracy (± 1 σ), in water,
± 2 % FS
0-120 °C (32-248 °F)
Response time (63.2 %) Less than 1 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
Resolution 1.2 mbar (0.02 psid)
Temperature
wetted materials
Liquid temperature, operation 0-120 °C (32-248 °F)
-25 to +120 °C (-13 to +248 °F),
Liquid temperature, peak
non-freezing
2xH
G
1.0
0.5
0.0
0 120
T max =
peak temperature
Fig. 149 Temperature response in Analogue mode
50
Pressure sensors
7
DPS, 0 - 1.6 bar (0 - 23.2 psid) Specifications
wetted materials
Liquid temperature, operation 0-120 °C (32-248 °F)
-25 to +120 °C (-13 to +248 °F),
Liquid temperature, peak
non-freezing
2xH
G
0.5
0.0
0 120
T max =
peak temperature
51
Pressure sensors
7
DPS, 0 - 2.5 bar (0 - 36.3 psid) Specifications
Differential Pressure sensor Standard, DPS
Pressure
Measuring range 0 - 2.5 bar (0 - 36.3 psid)
Accuracy (± 1 σ), in water,
± 1.5 % FS
15-90 °C (59-194 °F)
Accuracy (± 1 σ), in water,
± 2 % FS
0-120 °C (32-248 °F)
Response time (63.2 %) Less than 1 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
Resolution 1.2 mbar (0.02 psid)
Temperature
wetted materials
Liquid temperature, operation 0-120 °C (32-248 °F)
-25 to +120 °C (-13 to +248 °F),
Liquid temperature, peak
non-freezing
2xH
G
0.5
0.0
0 120
T max =
peak temperature
52
Pressure sensors
7
DPS, 0 - 4.0 bar (0 - 58.0 psid) Specifications
4.5
4.0 Electromagnetic compatibility EN 61326-1
3.5
3.0
2.5
2.0
1.5
1.0
TM06 3354 5214
0.5
0.0
0 120
T max =
peak temperature
53
Pressure sensors
7
DPS, 0 - 6.0 bar (0 - 87.0 psid) Specifications
Differential Pressure sensor Standard, DPS
Pressure
Measuring range 0 - 6.0 bar (0 - 87.0 psid)
Accuracy (± 1 σ), in water,
± 1.5 % FS
15-90 °C (59-194 °F)
Accuracy (± 1 σ), in water,
± 2 % FS
0-120 °C (32-248 °F)
Response time (63.2 %) Less than 1 s
System pressure deviation 6 mbar/bar (0.09 psid/psig)
Resolution 1.2 mbar (0.02 psid)
Temperature
wetted materials
Liquid temperature, operation 0-120 °C (32-248 °F)
-25 to +120 °C (-13 to +248 °F),
Liquid temperature, peak
non-freezing
2xH
G
0.5
0.0
0 120
T max =
peak temperature
54
Pressure sensors
8
8. Product range
Product range
RPI transmitter
Scope of delivery:
• RPI transmitter
• 2 m (6.5 ft) cable
• quick guide.
Temperature O-ring
Complete product range Pressure range Thread Outside usage
measurement EPDM FKM
RPI/--0-0.6b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-0.6b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 0.6 bar ● ●
G 1/2
RPI/--0-0.6b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 8.7 psig) ● ● ●
RPI/--0-0.6b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/--0-1.0b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-1.0b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 1.0 bar ● ●
G 1/2
RPI/--0-1.0b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 14.5 psig) ● ● ●
RPI/--0-1.0b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/--0-1.6b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-1.6b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 1.6 bar ● ●
G 1/2
RPI/--0-1.6b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 23.2 psig) ● ● ●
RPI/--0-1.6b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/--0-2.5b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-2.5b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 2.5 bar ● ●
G 1/2
RPI/--0-2.5b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 36.3 psig) ● ● ●
RPI/--0-2.5b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/--0-4.0b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-4.0b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 4.0 bar ● ●
G 1/2
RPI/--0-4.0b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 58.0 psig) ● ● ●
RPI/--0-4.0b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/--0-6.0b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/--0-6.0b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 6.0 bar ● ●
G 1/2
RPI/--0-6.0b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 87.0 psig) ● ● ●
RPI/--0-6.0b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/---0-10b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/---0-10b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 10.0 bar ● ●
G 1/2
RPI/---0-10b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 145.0 psig) ● ● ●
RPI/---0-10b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/---0-16b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/---0-16b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 16.0 bar ● ●
G 1/2
RPI/---0-16b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 232.1 psig) ● ● ●
RPI/---0-16b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
RPI/---0-25b/1/C/M2.00-X/EG6/--/03P/SD-1 ● ●
RPI/---0-25b/1/C/M2.00-X/VG6/--/03P/SD-1 0 - 25.0 bar ● ●
G 1/2
RPI/---0-25b/1/F/M2.00-X/EG6/--/03P/SD-1 (0 - 362.6 psig) ● ● ●
RPI/---0-25b/1/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
55
Pressure sensors
8
DPI II and DPI II+T transmitter
Product range
Scope of delivery:
• DPI II and DPI II+T transmitter
• 2 m (6.5 ft) cable
• capillary tube with fitting
• quick guide.
Temperature O-ring
Complete product range Pressure range Thread Outside usage
measurement EPDM FKM
DPI/--0-0.6b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-0.6b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 0.6 bar ● ●
G 1/2
DPI/--0-0.6b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 8.7 psid) ● ● ●
DPI/--0-0.6b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/--0-1.0b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-1.0b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 1.0 bar ● ●
G 1/2
DPI/--0-1.0b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 14.5 psid) ● ● ●
DPI/--0-1.0b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/--0-1.6b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-1.6b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 1.6 bar ● ●
G 1/2
DPI/--0-1.6b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 23.2 psid) ● ● ●
DPI/--0-1.6b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/--0-2.5b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-2.5b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 2.5 bar ● ●
G 1/2
DPI/--0-2.5b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 36.3 psid) ● ● ●
DPI/--0-2.5b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/--0-4.0b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-4.0b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 4.0 bar ● ●
G 1/2
DPI/--0-4.0b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 58.0 psid) ● ● ●
DPI/--0-4.0b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/--0-6.0b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/--0-6.0b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 6.0 bar ● ●
G 1/2
DPI/--0-6.0b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 87.0 psid) ● ● ●
DPI/--0-6.0b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/---0-10b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/---0-10b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 10.0 bar ● ●
G 1/2
DPI/---0-10b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 145.0 psid) ● ● ●
DPI/---0-10b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
DPI/---0-16b/2/C/M2.00-X/EG6/--/03P/SD-1 ● ●
DPI/---0-16b/2/C/M2.00-X/VG6/--/03P/SD-1 0 - 16.0 bar ● ●
G 1/2
DPI/---0-16b/2/F/M2.00-X/EG6/--/03P/SD-1 (0 - 232.1 psid) ● ● ●
DPI/---0-16b/2/F/M2.00-X/VG6/--/03P/SD-1 ● ● ●
56
Pressure sensors
8
DPI I transmitter
Product range
The DPI I transmitter is available as an individual packaged transmitter as well as in sets with capillary tubes.
As standard, the scope of delivery includes: (for outside usage only powered by Grundfos pump or the SI power
supply. See accessory section for more information.)
• DPI I transmitter
• cable with bracket
• installation and operating instructions.
See table below for sets with special parts.
Reducing
Pressure Cable Wall Motor Capillary piece Service Outside
Product description
range length bracket bracket tube 7/16-20 UNF instructions usage
- R 1/4
0 - 0.6 bar 0.9 m
DPI/--0-0.6b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 8.7 psid) (2.9 ft)
0 - 1.0 bar 0.9 m
DPI/--0-1.0b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 14.5 psid) (2.9 ft)
0 - 1.6 bar 0.9 m
DPI/--0-1.6b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 23.2 psid) (2.9 ft)
0 - 2.5 bar 0.9 m
DPI/--0-2.5b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 36.3 psid) (2.9 ft)
0 - 4.0 bar 0.9 m
DPI/--0-4.0b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 58.0 psid) (2.9 ft)
0 - 6.0 bar 0.9 m
DPI/--0-6.0b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 87.0 psid) (2.9 ft)
0 - 10.0 bar 0.9 m
DPI/---0-10b/1/G/D.900-B/V-5/--/---/VC-1 ● ●
(0 - 145.0 psid) (2.9 ft)
0 - 0.6 bar 0.9 m
DPI/--0-0.6b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 8.7 psid) (2.9 ft)
0 - 1.0 bar 0.9 m
DPI/--0-1.0b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 14.5 psid) (2.9 ft)
0 - 1.6 bar 0.9 m
DPI/--0-1.6b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 23.2 psid) (2.9 ft)
0 - 2.5 bar 0.9 m
DPI/--0-2.5b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 36.3 psid) (2.9 ft)
0 - 4.0 bar 0.9 m
DPI/--0-4.0b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 58.0 psid) (2.9 ft)
0 - 6.0 bar 0.9 m
DPI/--0-6.0b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 87.0 psid) (2.9 ft)
0 - 10.0 bar 0.9 m
DPI/---0-10b/1/G/D.900-B/V-5/-B/02B/SD-1 ● ● ● ● ● ●
(0 - 145.0 psid) (2.9 ft)
0 - 1.2 bar 5m
DPI/--0-1.2b/1/G/D5.00-B/V-5/-B/02B/TD-1 ● ● ●
(0 - 17.4 psid) (16.4 ft)
0 - 2.5 bar 5m
DPI/--0-2.5b/1/G/D5.00-B/V-5/-B/02B/TD-1 ● ● ●
(0 - 36.3 psid) (16.4 ft)
0 - 4.0 bar 5m
DPI/--0-4.0b/1/G/D5.00-B/V-5/-B/02B/TD-1 ● ● ●
(0 - 58.0 psid) (16.4 ft)
0 - 6.0 bar 5m
DPI/--0-6.0b/1/G/D5.00-B/V-5/-B/02B/TD-1 ● ● ●
(0 - 87.0 psid) (16.4 ft)
0 - 10.0 bar 5m
DPI/---0-10b/1/G/D5.00-B/V-5/-B/02B/TD-1 ● ● ●
(0 - 145.0 psid) (16.4 ft)
57
Pressure sensors
9
9. Accessories
Accessories
Description
M12 cable
4-wire screened cable with M12 connector in the
sensor end and open end in the equipment end. Use Adapter for RPI, RPI+T and DPI II and DPI II+T
the cable for the industrial sensor series such as RPI,
DPI II and VFI.
Description Length
Snap-on cable
Cable, industry, M2.000X 2 m (6.6 ft) Cable with snap-on connection in the sensor end and
different variants in the equipment end, such as open
end, ferrules and various types of connectors.
Cable, industry, M5.000X 5 m (16.4 ft)
Use the cable for the standard sensor series such as
VFS, RPS and DPS.
The cable is available in various lengths, mainly 1.2 m
Capillary tube and 2.9 m.
Use the capillary tube together with the DPI I, DPI II
and DPI II+T to connect the transmitter to the low- Description Length [mm]
pressure side of the equipment. Ferrules, 1.2 m 1.200
The capillaries are available in copper and stainless
steel as well as in various lengths. Ferrules, 2.9 m 2.900
Description
58
Pressure sensors
9
SI converter
Accessories
The SI converter from Grundfos Direct Sensors™ is an
external power supply, signal amplifier and signal
converter for Grundfos standard sensors: RPS, VFS
and DPS.
The SI converter has built-in precision resistors
enabling the sensor to transmit 4-20 mA, 1-5 V and
2-10 V output signals.
Use the SI converter in applications incorporating
sensors from the standard product range. The sensor
interface delivers a 4-20 mA input signal to external
controllers.
Specifications:
• Voltage range: 115-230 VAC ± 10 % or 24 VDC.
• Frequency: 50-60 Hz.
• Power consumption: Maximum 2.5 W.
• Ambient temperature: -20 to +50 °C (-4 to +122 °F).
• Enclosure class: IP20.
Part
SI converter, IP20
59
Pressure sensors
10
10. Appendix
Appendix
60
Pressure sensors
11
http://product-selection.grundfos.com
61
ECM: XX
97790251 0818
GRUNDFOS A/S
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. © Copyright Grundfos Holding A/S