Data Sheet Centrifugal Pump ASME B73.1 B73.2: CUS TOM LOG O
Data Sheet Centrifugal Pump ASME B73.1 B73.2: CUS TOM LOG O
Data Sheet Centrifugal Pump ASME B73.1 B73.2: CUS TOM LOG O
CUSTOM
CUS TOMER
TOMER LOG
CUSTOMER LOGO
O N° PO: Rev: A
Doc. Client: P-0017058-03-002-13221-H001 Qty. Required: 1
DATA SHEET Doc. VEPICA: H1N0021410-SP2D3-MD17002 RFQ. N°:
CENTRIFUGAL PUMP Item TAG: PDA-P-1200 P&ID N°: P-0017058-03-002-16221-D001
ASME B73.1 ; B73.2 Project Title: Interconexión Sistema Sandjet en Equipos Mayores de Separación y Deshidratación
Applicable to: £ Proposal R Purchase £ As built Specification No.:
Customer: PETROSUCRE Site: PLATAFORMA 4F
Service: Agua de Salida de Sandjet hasta Tanque de Sólido Unit: Total Number required: 1
Manufacturer: Serial No.:
Note: Indicates Information to be Completed l By Purcharser u By Supplier n Supplier if not by purchaser
ASME CENTRIFUGAL PUMPS (U.S. CUSTOMARY UNITS) ASME B73.1 Rev
1 Facility name / location: PLATAFORMA 4F / GOLFO DE PARIA - Edo. SUCRE - VENEZUELA
2 Item name: Purchaser / location:
3 Item tag number: PDA-P-1200 Job number:
4 Service: Agua de Salida de Sandjet hasta Tanque de Sólido Purchaser order number:
5 Unit: Supplier / location:
6 P&ID number: P-0017058-03-002-16221-D001 Supplier order / serial numbers: /
7 l GENERAL
8 No, of pumps req: 1 Motor item number:
9 n Pump size: 4 x 6-13 Motor provided by Vendor
10 n Pump model: ANSI Pump Motor mounted by: Vendor
11 n Pump type: End Suction Pump Variable speed operation: £ YES R NO
12 l Operating Conditions u Performance (Note 4)
13 Rated Additional duty points (max, min, or VS) Performance curve number: n Speed: 900 rpm
14 Point #: 1 2 3 4 5 Total differential head @ rated impeller: 23 ft
15 Flow: 380.91 346.28 103.88 gpm Maximum differential head @ rated impeller: 28 ft
16 Head: 23 ft Point #: 1 2 3 4 5
17 NPSHA: 48.29 ft NPSHR: 4.1 ft
18 Suct. Pres.: 17.48 psig Minimum continuous stable flow: 89.4 gpm
19 n Speed: 900 rpm Allowable operating region: to: gpm
20 Best efficiency point for rated impeller gpm
21 System design: Suction specific speed: 10,910
22 Suction pressure: min / max: 17.48 / 19.14 psig Impeller diameter: Rated: 10.125 Max: 13 Min: 9 in
23 Suction temperature: min / max: 150 / 210 °F Pump rated power: 3.1 BHP Efficiency: 73.5 %
24 R Stand-alone operation Maximum power with rated impeller: 3.5 BHP
25 £ Parallel operation with item no.: Case pressure rating:
26 £ Series operation with item no.: Maximum allowable working pressure psig @ °F
27 Service: Hydrostatic test pressure psig
28 £ Continuous R Itermittent: starts / day l Site Conditions and Utilities (Note 1 & 2)
29 System control method Location:
30 £ Speed £ Throttel £ System Resistance Only £ Indoor R Outdoor Altitude: 27.5 ft
31 l Pumped Fluid (Note 3) Range of ambient temperatures: min./max. 59 / 102.2 °F
32 Pumped fluid: Water with Sand in suspension Electrical area classification: £ NONHAZARDOUS
33 RATED MAX NORMAL MIN CI: Div. Or Zone: Gr: T code
34 Pumping temperature: 200 210 200 150 °F Electricity: Voltage Phase Hertz
35 * At pumping temperatures designates above Drivers 480 3 60
36 Specific gravity*: 1.01 1.02 1.01 0.97 Heating
37 Vapor pressure*: (psia) 10.18 10.18 Cooling water Source:
38 Viscosity*: (cP) 0.3 0.3 0.5 Supply temp.: °F Max. Return temp: °F
39 Specific heat*: (Btu/lb °F) 1.000764 Supply pressure: psig Design press.: psig
40 Atm pressure boilin point: °F @ psia Min. Return press. psig Max. Allow D.P. psig
41 Liquid: £ Hazardous £ Flammable pH: Chloride concentration: ppm
42 £ Other: l General Remarks
43 Corrosion / erosion caused by: Water with Sand in suspension 1- Relative Humidity (Min / Max) % : 70/100
44 % solids: Max. Particle size: in 2- Marine Environment
45 Other: 3- Shut Off Pressure (psia): 55.63; Hydraulic Power (hp): 2.21
46 Other: 4- Manufacturer must validate the information indicated
47 Other:
48
49
50 REVISION A
51 DATE 21/02/2019
52 PREPARED D. HRLIC
53 REVIEWED
54 APPROVED