F132 60+i
F132 60+i
F132 60+i
Date/Sign/rev.: 15.09.2016/OH/C
Technical data:
Pump Data
Pump Make Allweiler
Pump Type TRILUB 210 R40 W115 IEC160
Capacity 20,3 24,4 m3/h
Speed 2925 3510 rpm
Absorbed Power 9,7 12,5 kW
NPSHR 5,7 7,9 m
Inlet Pressure 0 bar
Outlet Pressure 5 bar
Diff. Pressure 5 bar
Medium LO, SAE 40
Temperature 15 °C
Viscosity 735 mm2/s
Motor Data
Motor type EL-MOTOR 160M-2 V1 IP54
Protection F IP55
Voltage 400 440 690* V
Frequency 50 60 60* Hz
Rated Power 15 17,3 15* kW
Ampere IN 27 27 18 A
Thermal protection Max 10% above IN A
Ampere IS x 7,6 A
Starting Method DOL
Weight 75 kilos
Bracket Supplied
Counterflanges Supplied
Pump type TRL Size of pump 210 Pitch angle 40 Project no.
Item
1 Liquid pumped SAE 40 / air: 1.5% 1# 2# 3# 4#
2 Density 0,894 kg/dm³ Pump capacity 24,7 m³/h 24,5 m³/h 20,5 m³/h 20,3 m³/h 2
3 Rotor housing GG25 Power req. 12,5 kW 5,9 kW 9,7 kW 4,8 kW 3
4 I(rotor) 0,00111 kgm² Starting torque 33,6 Nm 16,0 Nm 31,4 Nm 15,4 Nm 4
5 I(coupl) kgm² Total efficiency 27,5 % 57,2 % 29,3 % 59,2 % 5
6 I(mag.coupl) kgm² Differential pressure 5,0 bar 5,0 bar 5,0 bar 5,0 bar 6
7 I(total) 0,00111 kgm² Speed 3555 1/min 3555 1/min 2955 1/min 2955 1/min 7
8 Calculation reference acc. to Temperature 15,0 °C 55 °C 15,0 °C 55 °C 8
9 VDMA 24 284 class II groupe II Viscosity 735 mm²/s 66,3 mm²/s 735 mm²/s 66,3 mm²/s 9
10 NPSH(pump) 7,9 m 4,4 m 5,7 m 3,3 m 10
11 Remarks 11
25
24.72 m³/h
24.48
735,2m³/h
mm²/s
24
66,3 mm²/s
23
22
21
20.5 m³/h
20.3 m³/hmm²/s
735,2
20
66,3 mm²/s
19
18
25
Power absorbed P [kW]
20 735,2 mm²/s
735,2 mm²/s
15
66,3 mm²/s
12.49 kW
66,3 mm²/s
10 9.72 kW
5.94 kW
5 4.76 kW
0
0 2 4 6 8 10 12 14 16 18
5 bar
Differential pressure p [bar]