Example Calculation Sheet

This document provides sizing calculations for an orifice plate flow meter with corner taps used to measure air flow. It details the pipe and flow properties, fluid properties of air, and calculations of factors like the Reynolds number, beta ratio, discharge coefficient, and sizing factor used to determine the orifice bore size according to industry standards. The maximum flowrate is 600kg/h and differential pressure is 25.304 kPa. The orifice bore is calculated to be 26mm based on the 0.6824 beta ratio and 38.1mm pipe diameter.

Uploaded by

Iñaki Eseberri
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views

Example Calculation Sheet

This document provides sizing calculations for an orifice plate flow meter with corner taps used to measure air flow. It details the pipe and flow properties, fluid properties of air, and calculations of factors like the Reynolds number, beta ratio, discharge coefficient, and sizing factor used to determine the orifice bore size according to industry standards. The maximum flowrate is 600kg/h and differential pressure is 25.304 kPa. The orifice bore is calculated to be 26mm based on the 0.6824 beta ratio and 38.1mm pipe diameter.

Uploaded by

Iñaki Eseberri
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

D/P Device sizing calculation sheet

DESCRIPTION: Sample Air Flow


P&I DRAWING NUMBER: TAG NUMBER: FE001
D/P PRODUCING DEVICE TYPE: ORIFICE WITH CORNER TAPS

FLOWING CONDITIONS:
Maximum flowrate 600 Maximum Diff. Pressure 25.30435181
Flow Rate units kg/H Diff. Pressure units kPa
Pipe internal diameter (mm) 38.1 Orifice material Stainless Steel 316 (-185-21 Deg C)
Orifice expansion coefficient (mm/mmºC) 0.0000128 Pipe Material Plain Carbon Steel (SAE 1020)
Pipe expansion coefficient (mm/mmºC) 0.000012 Pipe Size/Schedule 40mm/SCH 80
Flowing temperature,ºC 10 Drain Hole Size (mm)
Flowing Pressure (kPa Abs) 351.325
FLUID PHYSICAL PROPERTIES:
Critical Temperature (ºC) -141 State of Fluid GAS or VAPOUR
Critical Pressure (kPa Abs) 3780 Isentropic Exponent 1.2
3
Density at Base Conditions (kg/m ) 0 Molecular Weight 29
3
Density at Flowing Conditions (kg/m ) 4.336925507 Base Temperature (ºC)
Specific Gravity Base Pressure (kPa Abs)
Name of Fluid Air Abs. Viscosity (cPoise) 0.0179

CALCULATION:
Thermal Expansion Factor (F A) 0.999739587 Drain Hole Factor (F DH) 1
Reynolds Number (RD) 262537.5402 Beta Ratio (ß) 0.682414711
Discharge Coefficient (C) 0.60439682 Sizing Factor (S M) 0.312036365
Gas Expansion Factor (Y 1) 0.981334686 Integral Orifice K-Factor
N-Factor (N) 0.126446694
Device Bore (d) = Beta Ratio (ß) x Pipe Diameter (D) in mm 26

(Calculated in Accordance with R W MILLER - FLOW MEASUREMENT ENGINEERING HANDBOOK)


NOTES:

PAGE 1 OF 1 PAGES REVISION


CALCULATED BY APPROVED BY
DATE DATE