Dial Setting /deviation Setting Type: Analog and Non Indication Type, Set Temperature by Dial
Dial Setting /deviation Setting Type: Analog and Non Indication Type, Set Temperature by Dial
Dial Setting /deviation Setting Type: Analog and Non Indication Type, Set Temperature by Dial
▣Features
(D)
Power
controlle
Please read "Caution for your safety" in operation
! manual before using.
(E)
Panel
meter
▣Ordering information
(F)
T O S F 4 Tacho/
R P 4 C Speed/
Pulse
meter
(G)
Unit Display
C ℃ unit
X 0~60
1 0~100
(H)
2 0~200 Sensor
controlle
Temperature range 3 0~300
4 0~400
6 0~600 (I)
8 0~800 Proximit
sensor
C 0~1200
P Pt100Ω
Sensor input type (J)
J J(IC) Photo
electri c
K K(CA) sensor
4 100-240VAC 50/60Hz
※Please check the range of temperature when select model. (Please see page C-41)
C-40
TOS/TOM/TDM/TOL/TDL
▣Specifications
Model TOS TOM TDM TOL TDL
C-41
Dial Setting /Deviation Setting Type
▣Connections
(A)
※RTD(Resistance Temperature Detector) : Pt 100Ω(3-wire type) ※Thermocouple : K, J, R Counter
- B 4 11
2 7 B'
(D)
! SOURCE
Power
SENSOR 1 8 5 12 controlle
B - 220VAC
+ A
~ S ENSOR 6 SENSOR ~ 13
T.C RTD 110VAC
! SOURCE ~ (E)
100-240VAC + 0V Panel
7 14
50/60Hz A T.C meter
RTD
(F)
Tacho/
lTOL, TDL Speed/
Pulse
meter
RTD T.C
CONTACT OUT: 1 18
A +
250VAC 3A 1c L (G)
Display
RESISTIVE LOAD 2 17 unit
C SENSOR
H
3 16 B
(H)
Sensor
SSR OUT: - 4 15 controlle
B' -
12VDC ±3V
20mA Max. + 5 14
※TDL outputs (I)
Proximity
up to 16VDC 6 13 sensor
220 VAC
7 12
(J)
110VAC Photo
! SOURCE ~ 8 11 electric
~ sensor
0V
9 10
(K)
Pressur
sensor
▣Dimensions
lTOS (L)
Rotary
lPanel cut-out encoder
92
48 Min. 53
13 64 15 (M)
5-P hase
stepping
motor &
+ 0.6 Driver &
45 -0 Controlle
M in. 62 45 +0.6
-0
TOS
Unit:mm
C-42
TOS/TOM/TDM/TOL/TDL
▣Dimensions
ON OFF
ON O FF
68 +0
-0
.7
200 10 0
Min. 91
68 +- 0.0 7
IN P UT K
℃ IN P U T K
○
℃
TO M TD M
Unit:mm
lTOL, TDL
1 21 lPanel cut-out
96
21 87 13 Min. 116
ON O FF
ON OFF
2 00 100
92 +- 0.8
0
Min. 116
I N PU T K
92 +0
-0
.8
C I N PU T K
℃
T OL TDL
Unit:mm
▣Proper usage
◎Application of temperature controller and load ◎How to select ON/OFF or proportional by plug
connection pin
lSSR output Factory specification is proportional control.
Temperature When using ON/OFF control, transfer the switch of
controller SSR
control mode from P to F after detaching the case
+
+
from its body.
SSR I
L Load Note)Several models require changing control
driving 12VDC N
P O
voltage 20mA M ax A mode by jump line or solder.
U Load
out put D ~
T power
terminal -
-
P F P F
lRelay output
Temperat ure controller Proportional control ON/OFF control
Load
NO ◎Indicating LED deviation
L Load
~ power The price of digital indicating type is high and non-
C COM
indicating type has a problem with catching actual
H temperature.
Relay contact output terminal
NC 250VAC 2A 1c In this case indicating deviation type is useful.
250VAC 3A 1c
LED deviation indicator is a temperature controller
◎NormalU Reverse operation having the function of lighting or putting out light.
Reverse operation outputs ON when processing ※The shipping specification is 10℃ per one LED.
value is lower than setting value, and it is used Extending temperature deviation is available with
with reverse operation when heated. additional orde
On the contrary, normal operation runs conversely
and used for cooling. (This item runs as a reverse
operation)
C-43