Up/Down Counter/Timer: DIN Size W72×H72, W48×H96, W144×H72mm COUNTER/TIMER
Up/Down Counter/Timer: DIN Size W72×H72, W48×H96, W144×H72mm COUNTER/TIMER
Up/Down Counter/Timer: DIN Size W72×H72, W48×H96, W144×H72mm COUNTER/TIMER
(F)
Tacho/
Speed/
Pulse
meter
▣Specifications
※Blacked( ) items are upgraded function.
(G)
Single preset FX4 FX6 FX4H Display
unit
Model Double preset FX4-2P FX6-2P FX4H-2P FX4L-2P FX6L-2P
Indication FX4-I FX6-I FX4H-I FX4L-I FX6L-I
Digit 4 6 4 4 6
(H)
Digit size W8×H14mm W4×H8mm W6×H10mm W8×H14mm Sensor
Power supply 100-240VAC 50/60Hz, 12-24VDC(option) controlle
A-44
FX/FXH/FXL Series
▣Specifications
Insulation resistance Min. 100MΩ(at 500VDC)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise AC power ±2kV the square wave noise(pulse width:1㎲) by the noise simulator
strength DC power ±500V the square wave noise(pulse width:1㎲) by the noise simulator
Mechanical 0.75mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 1 hour
Vibration
Malfunction 0.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 10 minutes
Mechanical 300m/s²(Approx. 30G) in X, Y, Z directions for 3 times
Shock
Malfunction 100m/s²(Approx. 10G) in X, Y, Z directions for 3 times
Relay Mechanical Min. 10,000,000 operations
life cycle Electrical Min. 100,000 operations at 250VAC 2A(resistive load)
FX4H :
FX4 : Approx. 295g FX6 : Approx. 305g
Approx. 325g FX4L-2P : FX6L-2P :
FX4-2P : FX6-2P :
FX4H-2P : Approx. 544g Approx. 550g
Weight Approx. 305g Approx. 315g
Approx. 353g FX4L-I : FX6L-I :
FX4-I : FX6-I :
FX4H-I : Approx. 455g Approx. 461g
Approx. 260g Approx. 265g
Approx. 297g
Approval
▣Connections
lFX-2P ( IN H IB IT ) lFX ( IN HI BI T) lFX-I (I N HI BI T)
RES ET SOLID STATE OU T R ESET SOLID STATE OUT
CP1 CP2 CP1 CP2 CP1 CP2 RESE T
0V OUT 1 OU T2 0V 0V
8 9 10 11 12 13 14 8 9 10 11 12 13 14 8 9 10 11 12 13 14
+1 2V +1 2V +12 V
50 mA 50 mA 5 0mA
15 17 15 17 15 17
16 18 16 18 16 18
OUT2 OU T1 OU T
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
CONTACT OUT: ! CONTACT OUT: ! !
250VAC 2A RESISTIVE LOAD - + 250VAC 2A RESISTIVE LOAD - + - +
SOLID
OUT1 2 11 2 11 2 11
(1st) ! ! !
STATE SOLID
OUT OUT2 1 10 STATE 1 10 1 10
(2nd) OUT
9 9 9
SOURCE SOURCE SOURCE
lFXL-2P (INHIBIT) lFXL-I (INHIBIT)
CP1 OUT1 OUT2 CP1
CP2 RESET CP2 RESET
13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24
0V 0V
+12V CONTA CT OUT: +12V
50mA 250VAC 2A 50mA
RE SIS TIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
OUT1 OUT2 ~
- +
! ~ !
SOLID STATE OUT - +
SOURCE SOURCE
※CP 2(INHIBIT) : Time hold t erminal when using for timer.
※It is operat ed by power ON start type when using for timer.
A-45
Up/Down Counter/Timer
▣Dimensions
lFX series (A)
lPannel cut-out Counter
86 126
M in.91
72 13 102 11
(B)
68.5 +0.5
-0
Timer
1s t _ _ _ _ _ _
7 7 7 7 7 7
Min.91
r r r r r r
68.5 +0.5
-0
_ _ _ _ _ _ RES ET
2s t
8 8 8 8 8 8
(C)
r r r r r r
TIM E
Temp.
FX 6-2P controlle
Unit:mm
lFXH series
113 lPannel cut-out (D)
Power
48 Min.50 controlle
13 90 10
C OU NT ER /TIM ER
+0.8 (E)
92 -0
Panel
OUT1 OUT2 meter
R E SE T TI M E
2n d _ _ _ _ Min.102
45 +0.6
-0
7 7 7 7 (F)
r r r r Tacho/
_ _ _ _
1 st
Speed/
8 8 8 8 Pulse
r r r r
meter
FX4H-2P
Unit:mm
(G)
Display
lFXL series unit
lPannel cut-out
163 122
Min.170
144 10 102 10
(H)
Sensor
+0.5
67.5 controlle
-0
OUT 1
OUT 2
PRES ET 1 PRESET 2
Min.78 +0.5
- - - - - - - - 138 -0
TIM E
(I)
7 7 7 7 8 8 8 8
Proximit
+ + + + + + + + RESET
sensor
FX4L-2P
Unit:mm
lSolid-state input(Standard input sensor :PNP output type sensor) lContact input motor &
Driver &
Controlle
Sensor Count/Timer Sensor Count/Timer Count/Timer
Brown Brown
+12V +12V +12V
Black ※ Inner Black ※ Inner ※ Inner
RL circuit circuit circuit
10kΩ 5.4kΩ 5.4kΩ 5.4kΩ
Blue Blue
0V 0V 0V
(PNP output) (PNP open Counting speed :
collector output) 1 or 30cps setting(Counter)
※CP1, CP 2(INHIBIT), RES ET Input
A-46
FX/FXH/FXL Series
▣Input logic selection
lFX series lFXL series lFXH series
Input logic is changeable by input Input logic is changeable by Input logic is changeable by input
logic selection switch located at the input logic selection switch logic selection switch (SW3)
one-side of case. located at the terminal block. located at inside of the case.
U No voltage input U Voltage input(PNP)
U No voltage input U Voltage input
(NPN) U No voltageinpu(NPN)
(NPN) (PNP)
NPN PNP NPN PNP F S
1 2 3 4 5 6 7
1 2 3 4 5 6 7 - +
- + (Power supply
(Power supply for the load) Load2
for the load) Load2 SOURCE
SOURCE
lPlease select proper capacity of load, because total lThe capacity of the load must not be exceed max. 30VDC,
value of load capacity and current consumption max. 100mA of the switching capacity of the transister.
should not be exceed current capacity.(Max. 50mA) lPlease do not supply the reverse polarity voltage.
※Please connector the surge absorber(Diode) at both
terminals of the load, in case of using the inductive load.
(Relay, etc.)
(FX4)
◎Using 2 counters with one sensor
lIt is available to use 2 counters with one sensor.
The power of sensor must be connected to only one of counter.
l
P R18-5DP l
Black Brown Blue Black Blue
8 9 10 11 12 13 14 8 9 10 11 12 13 14
CP1 C P2 +12V 0V CP1 C P2 +1 2V 0V
(FX4) (FX6-I)
A-47
Up/Down Counter/Timer
▣Selection by DIP switches
(A)
l72×72 DIP switch position l48×96 DIP switch position l144×72 DIP switch position Counter
(B)
Timer
(C)
Temp.
Single output one-one/shot selection controlle
Counter
* ** only **Indication type *Single preset (F)
(No. 5, 6, 7, 8 in SW1) (No. 8 in SW1) Tacho/
Speed/
8 7 6 5 4 3 2 1 4 3 2 1 Pulse
ON meter
(G)
SW1 SW2 Display
unit
lMax. counting speed lConter/Timer lMemory retention
SW2 Functions SW2 Functions SW2 Functions
1 2 ON ON (H)
Power reset Sensor
ON Conter
1cps OFF OFF (Non memory) controlle
OFF
3 4
ON ON
1 2 Timer Memory
OFF OFF
ON (I)
30cps Proximit
OFF lUp/Down mode sensor
1 2
SW1 Functions
ON
2kcps ON (J)
OFF Down mode Photo
OFF electri c
1 2 4 sensor
ON ON
5kcps Up mode
OFF OFF
(K)
Pressur
lSelection of one-shot output or hold output ※Example of F output operation mode sensor
for 1st output.
A-48
FX/FXH/FXL Series
▣Input operation(Counter)
Input mode(SW1) No-voltage input type(NPN) Voltage input type(PNP)
H H
cp1 cp1
Up/Down-A L A A L A A
4 2 3
H
ON Command ON cp2 L cp2 H
L 3 3
3 3
OFF input OFF Counting 2 2 2 Counting 2 2 2
1 1 1 1
value 0 value 0
H H
cp1 L cp1 L
Up/Down-B 2 3
Individual ON cp2 H H
cp2 L
L 3
3 3 3
Counting 2 2 2 2 2 2
input OFF 1 1 1 Counting 1 1 1
value 0 value 0
Phase ON H cp2 H
Up cp2 L
difference L 3 3 3 3
mode OFF 2 2 2
Counting 2 2 2
1 1 1 1
input 0 value 0
H H
cp1 L cp1
A A
L A A
H H
cp2 L cp2
No counting
L No counting
5 5
Counting 4 4
2 3 3 3
1 2 Counting 1 2
ON value
Up 0 value 0
Up input OFF No counting
cp1 H No counting
cp1
H
L L
A A A A
H H
cp2 L cp2 L
5 5
3 4 3 4
Counting 2 Counting 2
1 1
value 0 value 0
H
cp1 H cp1
L
L A A
4 Up/Down-D 2 3 A A
ON ON H H
Command cp2 cp2
L L n
n n-1 n-1 n -1
OFF OFF Counting n-1 Counting
input n-2
n-3
n-2 n-2
n-3
n-2
n-3
n-2 n-2
n-3
value value
0 0
H H
cp1 L cp1 L
Up/Down-E 2 3 H
cp2 H
ON cp2 L
Individual n
L
n
n-1 n-2 n-1 n-1 n-1
input OFF
Counting n-2 n-2 n-3 Counting n-2 n-2 n-1 n-1 n-2
n-3 n-3 n-3
value value
0 0
H
cp1 H cp1
Up/Down-F L L B B B B
2 3
B B B B
Phase ON H cp2 H
cp2 L
Down L
difference n Counting
n
n-1 n-1
OFF Counting n-1 n-1 n-2 n-2 n-2
mode input value
n-2 n-3 n-2 n-2
n-3 value n-3 n-3
0 0
H cp1 H
cp1
L A A L A A
H H
cp2 L cp2
No counting
L No counting
n n-1 n
Counting n-1 n-2
n-2 Counting
n-3 n-3
value n-4 n-5 value n-4 n-5
2 3
ON 0 0
Down
Down input OFF cp1 H No counting H No counting
L cp1
L A A
A A
H H
cp2 cp2 L
L n
n n-1
Counting n-1
Counting n-2 n-2
n-3 n-4 n-3
value n-5 value n-4 n-5
0 0
A-49
Up/Down Counter/Timer
▣Time setting mode(timer)
SW1 4Digit 6Digit (A)
Counter
1 2 3
ON
A 99.99sec 99999.9sec
OFF
1 2 3 (B)
ON Timer
B 999.9sec 999999sec
OFF
1 2 3
ON
C 9999sec 99min 59.99sec (C)
OFF Temp.
controlle
1 2 3
ON
D 99min 59sec 999min 59.9sec
OFF
(D)
1 2 3 Power
ON controlle
E 999.9min 99999.9min
OFF
1 2 3
ON 99hour 59min
F 99hour 59min 59sec (E)
OFF Panel
meter
1 2 3
ON
G 999.9hour 9999hour 59min
(F)
OFF
Tacho/
1 2 3 Speed/
ON Pulse
H 9999hour 99999.9hour meter
OFF
(G)
▣Counting function(Indication model) Display
unit
lUp mode lDown mode
RESET RESET
0 0 (J)
Photo
-Display value -Display value electric
sensor
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ (L)
RESET RES ET R ESET RE SET
Rotary
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
encoder
+ + + + TIM E
+ + + + TIM E
+ + + + TIME
+ + + + TIM E
(M)
RUN mode Return to RUN mode 5-Phase
stepping
※It returns to decimal point ※When "dp" is flickering, ※If pressing one of digital ※It returns to RUN mode if mot or &
setting status if pressing one touch the Reset switch buttons ( + , - ) pressing RESET button for Dr iver &
Controlle
RESET button for over button. in decimal point setting over 3sec. in decimal point
3sec. in RUN mode. mode, decimal point will be setting status.
moved to Up(+)direction.
lChanging the decimal point
※It returns to RUN mode if no RESET
+ + + + button or digital switch is applied for
60s ec. in decimal point settingstetus .
- - - - ※The decimal point setting is existed in
(Factory default)
indication type.
A-50
FX/FXH/FXL Series
▣Output operation mode
※The output of single preset
One-shot output(0.05~5sec) Hold output Self-holding type is operated at the status
of 2nd output out put of the second output mode
One-shot output(0.5sec) of 1st output
4 4
Output mode ON ON
Up mode Down mode Operation after count up
(SW1) OFF OFF
F Reset Reset The display value continues until Reset
2nd Preset 2nd Preset signal applied and the output is held.
5 6 7 1st Preset 1st Preset U 1st self-holding output and 2nd output
ON 0 0 is held until Reset signal applied.
OFF 1st Output 1st Output U When using 1st output as one-shot output,
2nd Output 2nd Output it will return after operating for 0.5sec.
N Reset Reset
2nd Preset 2nd Preset
5 6 7 1st Preset 1st Preset The dis play value and output will be
ON 0 0 held until Reset input is applied.
1st Output 1st Output
OFF 2nd Output 2nd Output
S Up Down
U Up, Up/Down-A , B, C input mode
Counter Reset Reset
-OUT1 is ON when(Display value)
2nd Preset 2nd Preset
1st Preset 1st Preset ≥ (1st preset value)
0 0 -OUT2 is ON when(Display value)
1st Output 1st Output ≥ (Double preset value)
5 6 7 2nd Output 2nd Output
ON U Down, Up/Down-D, E, F input mode
OFF Reset Reset -OUT1 is ON when(Display value)
2nd Preset 2nd Preset ≤ (1st preset value)
1st Preset 1st Preset -OUT2 is ON when(Display value)
0 0 ≤ (Zero)
1st Output 1st Output
2nd Output 2nd Output
S Reset Reset
Timer 2nd Preset 2nd Preset
1st Preset 1st Preset When it is used as Timer, 1st output and
5 6 7 0 0
ON 2nd output are flickering repeatedly.
1st Output 1st Output
OFF 2nd Output 2nd Output
A-51
Up/Down Counter/Timer
▣Proper usage
(A)
◎Reset ◎INHIBIT(Only Timer) Counter
lReset SW1
(J)
If either ON or OFF signal is shorter than minimum 9 9 9 9 9 9 5 9 5 9
R ES ET
+ + + + + +
R ESE T
Photo
electric
+ + + +
signal width, this product may not respond. hour min sec
m cm
sensor
T IM E
T IM E
F X4 FX6
Ta Tb
Therefore Ta(ON width) and P lease put black dot. Please put black dot.
Tb(OFF width) needed to be (K)
over min.signal width. ◎Error display Pressur
sensor
3×Ta
When duty cycle is 1:3, the Error signal Error description Returning method
maximun counting speed will
be ½ from that in our catalog. Change the set value
Zero set state (L)
to non zero state Rotary
This product does not respond. encoder
※There is no Error display function in indication type.
◎Power ※When Error is displayed, the output continues OFF (M)
The inner circuit voltage starts to rise up for the state. 5-Phase
stepping
first 100ms after power on, the input may not work mot or &
Dr iver &
at this time. And also the inner circuit voltage drops Controlle
down for the last 500ms after power off, the input 1s t - - - -
- - - - 0 1 0 0
may not work at this time. 0 0 0 0 RE SE T 2s t
+
-
+
-
+
-
+
-
R ES ET
+ + + + 0 0 5 0
ON T I ME TI M E
+ + + +
A-52