E82ZBC
E82ZBC
E82ZBC
E82ZBC
00408683 Communication module
06/99 Keypad and accessories
These instructions
é include the most important technical data.
é describe the installation, the handling of the keypad and keypad accessories.
é is valid only
- for Keypad labelled E82ZBC or E82ZBB,
- for hand-held terminals labelled E82ZBH,
- for mounting kits (door) labelled E82ZBHT,
- for connection cables labelled E82ZWLxxx,
- together with the Operating Instructions of the corresponding controller.
Description
The keypad enables the communication with Lenze controllers via a keypad.
Scope of application
The keypad can be used with controllers as from the nameplate labelling:
é 8200 frequency inverters
- E82xxxxxxxBxxxXXVx1x
Required accessories
Connection cable (for hand-held terminal and door installation only)
Function
é Parameterization
é Control (e.g. inhibit and enable)
é Display operating data
é Enter setpoints
é Transfer parameter sets to other controllers
General data and operating conditions of the keypad
Insulation voltage to ground/PE 50 V AC
Enclosure IP55
Ambient temperature during operation: -10 ... + 60 C
Transport: -25 ... + 70 C
Storage: -25 ... + 60 C
Climatic conditions Class 3K3 acc. to EN 50178 (without condensation,
medium relative humidity 85 %)
Dimensions (L x W x H) 75 mm x 62 mm x 23 mm
- 1- MA8200KEY
Show/Hide Bookmarks
Installation
The 8200 motec maintains its degree of protection even if the connection
cable is inserted and the sealing plug is removed.
The keypad can be connected or disconnected and parameterized during
operation.
The rear side of the keypad is bolted to the hand-held terminal (remove
rubber coating).
Use the kit E82ZBHT (cut-out 45.3 x 45.3 mm) to mount the keypad e.g. to
a control cabinet panel.
8200 vector
8200vec020
8200 motec
8200mot031
1. Plug keypad into the hand-held terminal and bolt (for E82ZBC only).
2. Remove sealing plug at the heatsink of the motec.
3. Connect hand-held terminal to the AIF interface using the connection cable.
The keypad is ready when the mains voltage is applied.
- 2- MA8200KEY
Show/Hide Bookmarks
Display / Functions
0 Function keys
1 Status displays
2 Bargraph display
3 Function bar 1
4 Function bar 2
5 Parameter set to be changed Modificati
on
6 Code number possible,
7
if
Subcode number display
8 Parameter value with unit
fl hi
flashing
0 Function keys
u Enable controller (X3/28 must be applied to HIGH level)
s Inhibit controller
t Change function bar 1↔ function bar 2
xw To the right/left in the active function bar
zy Incrase/decrease value. Scroll: Keep key pressed
v p
Save parameters if flashing. Confirmation by672 F in the display.
1 Status displays
d Ready
c Pulse inhibit (power outputs inhibited)
b Set current limit exceeded (C0022 (motor mode) or C0023 (generator mode))
e Warning active
a Fault active
2 Bargraph display
Value set under C0004 in %. (Default setting: unit load capacity C0056).
Display range: - 180 % ... + 180 % (each bar = 20 %)
3 Function bar 1
j Setpoint input viayz (Not possible with active password protection
(display = °MOE°)
g display function: Display memory unit 1 of the user menu (C0517/1)
(active after every and active parameter set
mains connection)
f 6
Select codes (display )
k Select subcodes (display )7
i Change parameter of a (sub)code (display )8
h Display values with more than five digits
H: High values (Display °+,°)
L: Low values (Display°MO° )
4 Function bar 2
m Parameter set 1 ... Select parameter set 4 for change
5
(Display e.g. PS ( ). The parameter sets can only be activated using digital
signals (configuration using C007 or C0410).)
n Select controller on the system bus (CAN) (remote parameterization)
(The selected controller (1 ... 63) can be parameterized from the momentary
drive.
r = function active)
o Select menu. The user menu is active after everyy mains connection. If
necessary change to DMM. ( RF : Code list in the user
necessary, ser menu (C0517) DMM:
men (C0517).
codes G EJ: Specific codes only for the function
List of all codes. f nction mod
modules
les INTERBUS,
INTERBUS
PROFIBUS-DP and LECOM-B.)
- 3- MA8200KEY
Show/Hide Bookmarks
User menu
After every mains switching, you have access to the user menu with the ten most
important drive parameters to commission a standard application with linear V/f
characteristic. For the complete code list please refer to the operating instructions of the
g
controller.
The first code of the user menu (C0517/1) is displayed after mains connection or using
.
C0050 Output frequency
-480.00 {Hz} 480.00
- 4- MA8200KEY
Show/Hide Bookmarks
User menu
C0010 minimum output frequency Operation with Lenze geared
motors,
t setting
tti range 1 : 6
0 00
0.00 480 00
480.00
Å C0010: 14.5
14 5 Hz
C0011 maximum output frequency Å C0011: 87.0 Hz
7.50 { 50.00 Hz } 480.00
C0012 Acceleration time main setpoint Reference:Frequency
q y change
g
0 00
0.00 { 5.00
5 00 s } 1300 00
1300.00 0 Hz
H ... C0011
wx
Result
o
Note
Change to function bar 2
yz
men ”ALL”
menu
2.
3.
4.
5. Select user
t
xz
DMM
å
f
Select menu ”ALL” (list of all codes)
Confirm selection, change to function bar 1
wx k
men
menu
6. Code for user menu
7. Select memory Code saved under C0517/1 is displayed
zx
unit
(default setting: output frequency C0050)
8.
9.
10.
Change
g entryy
yz i
;;;;;
Select subcode
11. v 672 F
°° must be entered to delete the entry.
- 5- MA8200KEY
Show/Hide Bookmarks
Edit parameters
Change and save parameters
The user menu is active after every mains switching.
Change to the menu DMM to call all codes.
If you should make a mistake during parameterization, load the default setting under
C0002 and start again.
Action
1. Plug in key-
pad
Key
g Result Note
The function g is active. The first code in the user
menu is displayed (C0517/1, default setting:
t
VVVV Hz
C0050 = output frequency).
2.
3.
If necessary,
y,
change to the
menu ”ALL”
ALL wx
yz o
Change to function bar 2
4.
5.
6. Inhibit con-
t
s ådc
DMM Select menu ”ALL” (list of all codes)
Confirm selection and change to function bar 1
Necessary only, if you change C0002, C0148, C0174
7.
troller
Set parame-
p wx
yz f and/or C0469
x k i
ters
8. ;;;; Select code
9. For codes without subcodes: automatic jump to
10.
11.
yz
xyz i
12.
13. v
w
;;;;;
672 F
Set parameters
Confirm entry, if
Confirm entry, if
pp is flashing
is not flashing; v is inactive
Change parameter set (PS)
You can use the keypad only to change over the parameter set, to modify parameters. To
g
activate a parameter set (PS) for operation, you must use digital signals (configuration
under C0410 or C0007)!
The function displays the currently active PS.
Action
1. Select t
Key
wx m
Result Note
Change to function bar 2
yz
f nction
function
2.
tå
3. Select PS Select PS to be changed
4. Confirm selection and change to function bar 1
5. Set Proceed as described in the table above
parameters
- 6- MA8200KEY
Show/Hide Bookmarks
- 7- MA8200KEY