STK 050
STK 050
STK 050
STK405-050
2ch AF Power Amplifier (Split Power Supply)
(30W + 30W min, THD = 10%)
Features
• Class B amplifiers
3.6
31.0
• Output load impedance RL=6Ω support
21.0
16.5
25.8
• EIAJ-output compatible (f=1kHz, THD=10%)
• Low supply switching shock noise
1 14
• Pin assignment grouped into individual blocks of 2.9
4.0
inputs, outputs and supply lines to minimize the 2.54 0.5 0.4
adverse effects of pattern layout on operating character- (11.29) 13×2.54=33.02 5.5
istics
• External boostrap circuit not necessary SANYO : SIP14
• Standby operation possible using external circuit
• Voltage gain VG=26dB for easy gain distribution within
the set
• Member of 10W/ch to 80W/ch pin-compatible series
Series Organization
The following devices form a series with differing output
capacity. Some of the following devices are under devel-
opment. Contact your Sanyo sales representative if you re-
quire more detailed information.
Supply voltage [V]
Type No. Output power
VCC max VCC
STK405-010 10W + 10W ±26.0 ±14.0
STK405-030 20W + 20W ±30.5 ±18.5
STK405-050 30W + 30W ±34.5 ±22.0
STK405-070 40W + 40W ±39.0 ±25.0
STK405-090 50W + 50W ±42.0 ±26.5
STK405-100 60W + 60W ±45.0 ±29.0
STK405-110 70W + 70W ±50.0 ±31.0
STK405-120 80W + 80W ±52.5 ±33.0
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
Specifications
Maximum Ratings at Ta = 25˚C
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage VCC max ±34.5 V
Thermal resistance θ j-c Per power transistor 3.4 ˚C/W
Junction temperature Tj 150 ˚C
Operating temperature Tc 125 ˚C
Storage temperature Tstg –30 to +125 ˚C
Available time for load short-circuit ts VCC=±22V, RL=6Ω, f=50Hz, PO=30W 1 s
Note.
All tests are measured using a constant-voltage supply unless otherwise specified.
Available time for load short-circuit and output noise voltage are measured using the transformer supply specified below.
The output noise voltage is the peak value of an average-reading meter with an rms value scale (VTVM). A regulated AC
supply (50Hz) should be used to eliminate the effects of AC primary line flicker noise.
No.5178–2/6
STK405-050
Block Diagram
Test Circuit
No.5178–3/6
STK405-050
No.5178–4/6
STK405-050
From expression (1)’ : θc-a < (125–50)/23 Therefore, to satisfy both expressions, the required heatsink
< 3.26 must have a thermal resistance less than 3.26°C/W.
From expression (2)’ : θc-a < (150–50)/23–3.4/4
< 3.49 The heatsink design example is based on a constant-volt-
age supply, and should be verified within your specific set
environment.
No.5178–5/6
STK405-050
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be expor ted without obtaining the expor t license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of October, 1999. Specifications and information herein are subject
to change without notice.
PS No.5178–6/6