Questions ProcessInstrumentation
Questions ProcessInstrumentation
For measuring level of an underground tank, where transmitter can not be mounted
below, which of the following technique may be unsuitable -
A. Hydrostatic head B. Bubbler C. Ultrasonic D. Displacer
Select the most appropriate answer for the following questions and write clearly the
selected option (A/B/C/D) against the question number in the answer sheet
For the above rotameter designed for the particular fluid flow measurement, it is
necessary that –
A..float density > fluid density B. float density = fluid density
C..float density = fluid density D. float density is independent of fluid
density
Which of the following sight glass level gauge is most suitable for high pressure, high
temperature, coloured liquids
A Reflex level gauge B Transparent level gauge
C Tubular level gauge D None of the above
In a vortex shedding flowmeter, the fluid velocity is proportional to
A.. frequency of the alternating pressure signal
B. width of the bluff body
Both of the above D. None of the above
In a thermal mass flow meter for measuring mass flow rate flowing medium is heated
by heater. If in the vicinity of heater, temperature measured at upstream of the heater
is T1 and that at downstream is T2 and the differential temperature (T2 –T1) is kept
constant by heater control, the mass flow rate indicated by the meter will be -
A. proportional to current input to heater B. proportional to voltage input to
heater
C. proportional to resistance of heater D. proportional to power input to heater
For an application demanding direct measurement of mass flow of slurries, the best
choice would be –
A. Coriolis meter B. Hot wire anemometer
C. Thermal mass flowmeter D. None of the above
For measuring level of an underground tank, where transmitter can not be mounted
below, which of the following technique may be unsuitable -
A. Hydrostatic head B. Bubbler C. Ultrasonic D. Displacer
30. In manometers, which is not a method to improve sensitivity and resolution for
measurement of low pressures -
Using manometer fluid with higher density
Using well type manometer with other limb as thin tube
Using inclined tube manometer
D. None of the above.
Which of the following differential pressure device is expected to cause the least
pressure drop for the same value of flow element bore to pipe diameter ratio –
A. Orifice B. Flow nozzle C. Short form venturi D. Long form venturi
For measuring flow of high temperature fluid at Reynolds number above 50000,
which of the following differential pressure device is most suitable -
A. Orifice B. Flow nozzle C. Short form venturi D. Long form venturi
For measuring flow of liquids containing solids, which of the following differential
pressure device is least suitable -
A. Concentric Orifice B. Eccentric Orifice C. Segmental Orifice D. Venturi
Which of the following is not a feature identified with smart transmitters -
A. Remote programmability B. Unidirectional communication
C. Range change capability D. Higher accuracy
For a given flow measuring application using orifice which pressure taps should give
maximum differential pressure -
A Corner taps B. Flange taps C. Pipe taps D. Vena contracta taps
For a given flow measuring application using orifice which pressure taps are decided
independent of pipe diameter -
A Flange taps B. Pipe taps C. Radius taps D. Vena contracta taps
For measuring flow of highly viscous fluid, which type of orifice is least suitable
A Quadrant edge B. Square edge C. Conical edge D. All are suitable
For a range of 20 to 100, the amount by which the measured variable zero is below
the lower range value, is called –
A Dead zero B. Live Zero C. Zero suppression D. Zero elevation
Control system
A variable which is input to the process and linked to the controller output is -
A Controlled variable B. Manipulated variable C. Process variable D.Feedback
signal
The objective of an automatic process control system is to adjust the –(A)-- to
maintain the –(B)-- close to –(C)-- in spite of disturbances.
The correct order of terms (A),(B),(C) fitting in the blanks above is -
Dead time in control system contributed by the material flow velocity delay is called –
A. Exponential lag B. Propagation delay
C. Process time constant delay D. Total dead time
A ‘wet leg’ condition can occur in hydrostatic level measurement in a tank, in case of
-
A. Open tank with non-evaporating liquids B. Open tank with evaporating
liquids
C. Closed tank with non-evaporating liquids D. Closed tank with evaporating liquids
Steady-state deviation of the controlled variable from set point, can be seen in control
using -
A. P B. PI
C. PID D. None of the above
Control Valves
A control valve where the closure member moves in a direction perpendicular to the
plane of seat is –
A. Ball valve B. Butterfly valve C. Gate valve D. Globe valve
For a control valve which of the following combination is expected to give fastest
response –
Electrical input signal transmission, electrical motor as actuator
Electrical input signal transmission, pneumatic piston actuator
Pneumatic input signal transmission, pneumatic diaphragm (spring opposed) actuator
Pneumatic input signal transmission, pneumatic piston actuator
A direct acting control valve can not be changed to act as reverse acting by suitable
modification in –