Apm 303
Apm 303
Apm 303
Command/Control
• Operation • Reports
The intuitive interface simplifies the generating 2 configurable reports
set user's experience • Safety features
• Operation mode Overspeed, oil pressure
Manual mode: manual start-up and stoppage Coolant temperatures
by the user Maximum and minimum voltage
Automatic mode: automatic start-up and Maximum and minimum frequency
stoppage via external order Maximum current
• Measurements Maximum active power
Phase-to-neutral or phase-to-phase voltages, Phase rotation direction
active power current, apparent power, power • Traceability
factors, kW/h energy meter, fuel level, oil Stack of 12 memorised events
pressure, coolant temperature • Neutral speed
• Supervision Compatible with all neutral systems
Modbus RTU communication via RS485 • Training
Self-training resource
Ergonomic, universal
LCD screen
Non-contractual document - In accordance with our product quality improvement policy, SDMO Industries reserves the right to modify any specifications, without prior notice.
APM303
Command/control
TECHNICAL DATA
OPERATION CONDITIONS
IP54 command/control on the front panel
Electronics protected against dust and humidity with tropicalised varnish
Designed, tested and CE qualified for use in harsh industrial environments
Operating temperature - 20°C / + 70°C
Storage temperature - 20°C / + 70°C
Relative humidity 95% @ 45°C without condensation
Altitude 2000m max
ELECTRICAL MEASUREMENTS
Nominal frequency 50Hz / 60Hz
Nominal voltage range 100 to 480 VAC phase / phase
Nominal current range In = 5A (CT secondary)
1.2Ln
Thermal overload
5 In (10 seconds)
CT (current transformer) ratio 1000 maximum
SETTINGS
Timing setting parameters
Protection setting parameters
RS485 communication setting parameters
CUSTOMER REPORTS AND INPUTS
One dry contact automatic starting order input (remote start)
Two of the following configurable outputs: alarm and fault report, fault report, alarm report, low fuel level, genset
on load
VIBRATION
3g from 5 to 500Hz
EMC
Electromagnetic compatibility directive 2004/108/CE dated 15 December 2004 - Class A
SAFETY
Low voltage directive 2006/95/CE dated 12 December 2006
Pollution degree 2
Non-contractual document - In accordance with our product quality improvement policy, SDMO Industries reserves the right to modify any specifications, without prior notice.
APM303
Command/control
APPLICATION DIAGRAM
FOR SITUATION NO. 2
Up to 2
configurable
Automatically controlled report outputs
normal/emergency
switching unit
Automatic starting
order
Installation powered on
Remote
supervision
OPTION DETAILS
To facilitate the transition between the Nexys and the APM303, SDMO offers an APM303 kit
to replace a Nexys.
Non-contractual document - In accordance with our product quality improvement policy, SDMO Industries reserves the right to modify any specifications, without prior notice.
Screenshots
Non-contractual document - In accordance with our product quality improvement policy, SDMO Industries reserves the right to modify any specifications, without prior notice.