ELEMENT NUMBER: ELEMENT TYPE: QUANTITY: VOLUME (M³) WEIGHT (KG)

01-001 ROOF SLAB 1 1.614 4039

CONCRETE GRADE: OVERALL DIMENSIONS:


LENGTH (MM) 4332
N40 WIDTH (MM) 1779

2 3 HEIGHT (MM) 400


SPECIFICATION:
4332 STANDARD/ CODE AS3850, NCC
NORM SYDNEY WATER SPEC. PART 1
2260 280 1512 280 ENVIRONMENT

630 1180 TOLERANCE AS3600


4xØ50 HOLES FULL
DEPTH OF ROOF SLAB.
90 190 BILL OF EMBEDS:
POS. QTY. TYPE
01 4 SWIFTLIFT ANCHOR 1.3T
190

190

280
680

1 1

1219

1779
Ø600 Ø600

90

280
190

190
OPENING FOR DN600 GATIC 190
COVER CLASS D (GM300S6D2)

OPENING FOR 1219 x 1512 GATIC


COVER CLASS D (GM303C1215D)

200 3000 1132

2 3

3D VIEW
1:20

ROOF PLAN
1:20

2260 100 1872 100 NOTES:


1. EDGES AND CONERS OF PRECAST UNIT TO BE FINISHED
110

WITH 15MM x 45 DEGREES CHAMFERS OR FILLETS.

REFERENCES:
290

290

1. FOR REINFORCEMENT, REFER DRAWINGS NO. 01-001_2.


2. FOR REINFORCEMENT (3D VIEWS), REFER DRAWINGS NO. 01-001_3.

SECTION 1
1:20

100 180 1219 180 100


110

145
290

290

REID SWIFT SNCHOR CAST IN 1.3T SWL


COMPLETE WITH RUBBER RECCESS FORMER.
WELD TO ROOF SLAB REINFORCEMMENT
(TOP AND BOTTOM)

SECTION 2 SECTION 3
1:20 1:20
BAR SCHEDULE
STEEL REINFORCEMENT SHALL BE TO AS/NZS46714.
STRENGTH GRADE = 500 MPa
1 2
DUCTILITY CLASS: N
02 02 02 02
SHAPE WEIGHT 2N12-166 3N12-200 3N12-133 2N12-116
POS. QTY. SIZE LENGTH
(MEASURES IN mm) kg/one kg/all
09 09 07
4N12-162 4N12-162 8N12-200
4230
4.26
165
01 4 N12 4500 17.0

2N12-116
1675
02 10 N12 1920 1.82 18.2
150

01
230

4N12-162

4N12-162
03 4 N12 500 0.47 1.9
165

3 3

7N12-184
9N12-183
480

04 4 N12 750 0.71 2.8


165

03

04
3N12-178
180

05
10
05 7 N12 450 0.43 3.0
165

2N12-116

06
2440
06 4 N12 2710 2.56 10.2
165

01
180

07 16 N12 420 0.40 6.4


150

08 08 07
4N12-162 4N12-162 8N12-200
695
08 8 N12 940 0.89 7.1
150

1 2
280

09 8 N12 520 0.49 3.9 ROOF PLAN - TOP


150

1:20

10 330 9 N12 1005 0.95 8.5


275

165

190 12 14
2N16 2N16
45° 705 45° TOP & BTM TOP & BTM
11 4 N16 1685 2.83 11.3
0

5
0

0
5

2140 45° 3D VIEW


12 8 N16 2630 4.42 35.4 11 2N16 1:15
5
0
0

TOP & BTM

45° 1100

13 4 N16 1590 2.67 10.7


0
0
5

08
N12
500
06
5

N12
8

45°
01
4

14 4 N16 1465 2.46 9.8 01 06 N12


45°
N12 N12
500

3.01 09
15 4 N16 1790 12.0
5

N12
0
0

45° 1300 15
2N16
TOP & BTM
16 23 16
N16 N16 N16 NOTES:
275

165

16 4 N16 4590 7.72 30.9 23


4230 N16 25
26 N16
N16 1. STEEL REINFORCEMENT SHALL BE TO AS/ NZS46714.
2. UNLESS NOTED OTHERWISE IN THE DRAWINGS, MINIMUM CLEAR COVER OF
12 13 REINFORCEMENT TO BE 75mm ON LIQUID FACES AND 50mm ELSEWHERE.
255

17 4 N16 2110 3.55 14.2 2N16 2N16 SECTION 1 (TRIMMER BARS NOT SHOWN)
1675 TOP & BTM TOP & BTM 1:20
REFERENCES:
1. FOR FORMWORK PLAN, REFER DRAWINGS NO. 01-001_1.
145

18 1675
7 N16 1890 3.18 22.3 ROOF PLAN - TRIMMER BARS 2. FOR REINFORCEMENT (3D VIEWS), REFER DRAWINGS NO. 01-001_3.

TOP COVER 50mm


1:20
165

0.80 28
19 5 N16 475 4.0 1N16
28
1N16
230
01 07
N12 01 N12
N12
165

20 5 N16 725 1.22 6.1 18 18 17 17


2N16-161 4N16-137 2N16-131 2N16-111 24
N16
480
07
26 26 24 N12
5N16-135 5N16-135 11N16-139
165

2N16-111

21 5 N16 575 0.97 4.8

BTM COVER 75mm


24 16
330 N16 N16
165 16
N16
180

22 8 N16 535 0.90 7.2


16

275
5N16-135
5N16-135

5N16-135
165

23 2440
5 N16 2685 4.52 22.6 SECTION 2
1:20
8N16-157

145
20
19

21
180

24 22 N16 500 0.84 18.5 27


N16 27
4N16-140

255 N16
22

02
N12
03 02 10 02
145

02 N12 N12 04 N12


25 10 N16 910 1.53 15.3 N12 N12
N12
695
23

2N16-111
145

26 10 N16 490 0.82 8.2 05


N12
280
19 22
N16 18 18 17 N16
N16 18 N16 N16
300

N16
16

27 2 N16 2165 3.64 7.3


1645 20 17
N16 N16
25 25 24 21
11N16-139 N16
5N16-135 5N16-135
18
300

N16
28 2 N16 2465 4.15 8.3
1950
SECTION 3 (TRIMMER BARS NOT SHOWN)
1:20
TOTAL 328.1 ROOF PLAN -BOTTOM
1:20
BAR SCHEDULE
STEEL REINFORCEMENT SHALL BE TO AS/NZS46714.
STRENGTH GRADE = 500 MPa
DUCTILITY CLASS: N
SHAPE WEIGHT
POS. QTY. SIZE LENGTH
(MEASURES IN mm) kg/one kg/all

4230
4.26
165
01 4 N12 4500 17.0

1675
02 10 N12 1920 1.82 18.2
150

230

03 4 N12 500 0.47 1.9


165

480

04 4 N12 750 0.71 2.8


165

180

05 7 N12 450 0.43 3.0


165

2440
06 4 N12 2710 2.56 10.2
165

180

07 16 N12 420 0.40 6.4


150

695
08 8 N12 940 0.89 7.1
150

280

09 8 N12 520 0.49 3.9


150

10 330 9 N12 1005 0.95 8.5


275

165

190

45° 705 45°

11 4 N16 1685 2.83 11.3 3D VIEW - TOP


0

5
0

0
5

1:15
0

45° 2140
12 8 N16 2630 4.42 35.4
0
0
5

45° 1100

13 4 N16 1590 2.67 10.7


0
0
5

3D VIEW - FULL REBAR


1:15
500
5
8

45°
4

14 4 N16 1465 2.46 9.8


45°
500

15 4 N16 1790 3.01 12.0


5
0
0

45° 1300
275

165

16 4230
4 N16 4590 7.72 30.9
255

17 4 N16 2110 3.55 14.2


1675
REFERENCES:
1. FOR FORMWORK PLAN, REFER DRAWINGS NO. 01-001_1.
145

18 7 N16 1890 3.18 22.3 2. FOR REINFORCEMENT, REFER DRAWINGS NO. 01-001_2.
1675
165

19 5 N16 475 0.80 4.0


230
165

20 5 N16 725 1.22 6.1


480 3D VIEW - TRIMMER
1:15
165

21 5 N16 575 0.97 4.8


330
165
180

22 8 N16 535 0.90 7.2


275
165

23 2440
5 N16 2685 4.52 22.6

145
180

24 22 N16 500 0.84 18.5


255
145

25 10 N16 910 1.53 15.3


695
145

26 10 N16 490 0.82 8.2


280
300

27 2 N16 2165 3.64 7.3


1645
300

28 2 N16 2465 4.15 8.3


1950

TOTAL 328.1