Doc
Doc
Doc
RESOLV® EC2472A
Restrictions on use : Refer to available product literature or ask your local Sales
Representative for restrictions on use and dose limits.
GHS Classification
Flammable liquids : Category 3
Carcinogenicity : Category 2
1 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
Storage:
Store in a well-ventilated place. Keep cool. Store locked up.
Disposal:
Dispose of contents/ container to an approved waste disposal
plant.
In case of eye contact : Rinse with plenty of water. Get medical attention if symptoms occur.
In case of skin contact : Wash off with soap and plenty of water. Get medical attention if
symptoms occur.
Protection of first-aiders : In event of emergency assess the danger before taking action. Do
not put yourself at risk of injury. If in doubt, contact emergency
responders.Use personal protective equipment as required.
Most important symptoms : See Section 11 for more detailed information on health effects and
and effects, both acute and symptoms.
delayed
Suitable extinguishing media : Use extinguishing measures that are appropriate to local
circumstances and the surrounding environment.
2 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
Specific extinguishing : Use water spray to cool unopened containers. Fire residues
methods and contaminated fire extinguishing water must be disposed
of in accordance with local regulations. In the event of fire
and/or explosion do not breathe fumes.
Personal precautions, : Remove all sources of ignition. Refer to protective measures listed
protective equipment and in sections 7 and 8.
emergency procedures
Environmental precautions : Do not allow contact with soil, surface or ground water.
Methods and materials for : Eliminate all ignition sources if safe to do so. Stop leak if safe to do
containment and cleaning up so. Contain spillage, and then collect with non-combustible
absorbent material, (e.g. sand, earth, diatomaceous earth,
vermiculite) and place in container for disposal according to local /
national regulations (see section 13). Flush away traces with water.
For large spills, dike spilled material or otherwise contain material to
ensure runoff does not reach a waterway.
Advice on safe handling : Take necessary action to avoid static electricity discharge (which
might cause ignition of organic vapours). Keep away from fire,
sparks and heated surfaces. Wash hands thoroughly after handling.
Use only with adequate ventilation.
Conditions for safe storage : Keep away from heat and sources of ignition. Keep in a cool, well-
ventilated place. Keep away from oxidizing agents. Keep out of
reach of children. Keep container tightly closed. Store in suitable
labeled containers.
Basis
Components CAS-No. Form of Permissible
3 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
exposure concentration
Heavy Aromatic Naphtha 64742-94-5 TWA 500 ppm OSHA Z1
2,000 mg/m3
TWA 200 mg/m3 ACGIH
Kerosene 8008-20-6 TWA 100 mg/m3 NIOSH REL
TWA 500 ppm OSHA Z1
2,000 mg/m3
TWA 200 mg/m3 ACGIH
Naphthalene 91-20-3 TWA 10 ppm ACGIH
TWA 10 ppm NIOSH REL
50 mg/m3
STEL 15 ppm NIOSH REL
75 mg/m3
TWA 10 ppm OSHA Z1
50 mg/m3
1,2,4-Trimethylbenzene 95-63-6 TWA 25 ppm NIOSH REL
125 mg/m3
Ethylbenzene 100-41-4 TWA 20 ppm ACGIH
TWA 100 ppm NIOSH REL
435 mg/m3
STEL 125 ppm NIOSH REL
545 mg/m3
TWA 100 ppm OSHA Z1
435 mg/m3
Respiratory protection : When workers are facing concentrations above the exposure limit
they must use appropriate certified respirators.
Hygiene measures : Handle in accordance with good industrial hygiene and safety
practice. Remove and wash contaminated clothing before re-use.
Wash face, hands and any exposed skin thoroughly after handling.
Appearance : Liquid
Colour : dark brown
Odour : hydrocarbon-like
Flash point : 56 °C
Method: ASTM D 93, Pensky-Martens closed cup
pH : Not applicable.
Odour Threshold : no data available
4 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
Incompatible materials : Contact with strong oxidizers (e.g. chlorine, peroxides, chromates,
nitric acid, perchlorate, concentrated oxygen, permanganate) may
generate heat, fires, explosions and/or toxic vapors.
Eyes : Health injuries are not known or expected under normal use.
Skin : Health injuries are not known or expected under normal use.
5 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
Inhalation : Health injuries are not known or expected under normal use.
Toxicity
Product
Acute oral toxicity : Acute toxicity estimate : > 5,000 mg/kg
Carcinogenicity
IARC Group 2B: Possibly carcinogenic to humans
Naphthalene 91-20-3
Ethylbenzene 100-41-4
6 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
Components
Acute dermal toxicity : Ethylbenzene
LD50 rabbit: 15,400 mg/kg
Ecotoxicity
Product
Toxicity to fish : LC50 Pimephales promelas (fathead minnow): 5.52 mg/l
Exposure time: 96 hrs
Test substance: Product
Components
Toxicity to algae : Kerosene
EC50 : 5 mg/l
Exposure time: 72 h
Mobility
The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation
program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition
between the total input and output. The level III model does not require equilibrium between the
defined media. The information provided is intended to give the user a general estimate of the
environmental fate of this product under the defined conditions of the models.
7 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
If released into the environment this material is expected to distribute to the air, water and
soil/sediment in the approximate respective percentages;
Air : <5%
Water : 5 - 10%
Soil : 70 - 90%
Bioaccumulative potential
Other information
no data available
If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the
Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, it should be
determined if the waste meets the criteria of a hazardous waste.
Disposal methods : The product should not be allowed to enter drains, water
courses or the soil. Where possible recycling is preferred to
disposal or incineration. If recycling is not practicable, dispose
of in compliance with local regulations. Dispose of wastes in
an approved waste disposal facility.
The shipper/consignor/sender is responsible to ensure that the packaging, labeling, and markings are
in compliance with the selected mode of transport.
The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product
causes it to be regulated with an additional description of RQ for road, or as a class 9 for road and air,
ONLY when the net weight in the package exceeds the calculated RQ for the product.
8 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product
causes it to be regulated with an additional description of RQ for road, or as a class 9 for road and air,
ONLY when the net weight in the package exceeds the calculated RQ for the product.
*Note: This product is regulated as a Marine Pollutant when shipped by Rail, Highway (in bulk
quantities), or Air (if no other hazard class applies), and when shipped by water in all quantities.
SARA 302 : No chemicals in this material are subject to the reporting requirements
of SARA Title III, Section 302.
SARA 313 : The following components are subject to reporting levels established
by SARA Title III, Section 313:
Naphthalene 91-20-3 1-5%
1,2,4-Trimethylbenzene 95-63-6 1-5%
Ethylbenzene 100-41-4 0.1 - 1 %
California Prop 65
WARNING! This product contains a chemical known to the State of California to cause cancer.
Naphthalene 91-20-3
Ethylbenzene 100-41-4
9 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
AUSTRALIA
All substances in this product comply with the National Industrial Chemicals Notification & Assessment
Scheme (NICNAS).
CHINA
All substances in this product comply with the Provisions on the Environmental Administration of New
Chemical Substances and are listed on or exempt from the Inventory of Existing Chemical Substances
China (IECSC).
EUROPE
The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS
inventories.
JAPAN
All substances in this product comply with the Law Regulating the Manufacture and Importation Of
Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).
KOREA
All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on
the Existing Chemicals List (ECL)
NEW ZEALAND
All substances in this product comply with the Hazardous Substances and New Organisms (HSNO)
Act 1996,and are listed on or are exempt from the New Zealand Inventory of Chemicals.
PHILIPPINES
All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the
Philippines Inventory of Chemicals & Chemical Substances (PICCS).
HEALTH 2*
2
Instability
Health
2 0 FLAMMABILITY 2
PHYSICAL HAZARD 0
0 = not significant, 1 =Slight,
2 = Moderate, 3 = High
Special hazard. 4 = Extreme, * = Chronic
10 / 11
SAFETY DATA SHEET
RESOLV® EC2472A
REVISED INFORMATION: Significant changes to regulatory or health information for this revision
is indicated by a bar in the left-hand margin of the SDS.
The information provided in this Safety Data Sheet is correct to the best of our knowledge,
information and belief at the date of its publication. The information given is designed only as a
guidance for safe handling, use, processing, storage, transportation, disposal and release and is
not to be considered a warranty or quality specification. The information relates only to the specific
material designated and may not be valid for such material used in combination with any other
materials or in any process, unless specified in the text.
For additional copies of an MSDS visit www.nalco.com and request access.
11 / 11