(9). If the velocity deviation between yellow and red LEDs is too large, then adjust the sensitivity
setting clockwise to increase sensitivity. Do step (5),(6),(7) again.
a
(10). a. For open collector output type : Putting two screws of sensitivity and alarm back.
B. For relay output type : Putting the cover back
(11). SP220 Economy Type can not set sensitivity and alarm.
d
a? 4xd
Fig. 1 Fig. 2 5.Specification
(1). Flow velocity: 1~150 cm/s (water), 3~300 cm/s(oil) or, water: 1~70 cm/s, oil: 2~100 cm/s
(2). Warm-up time: 15 sec. (approximate)
(3). Operation temperature: -20 ~ 80BC(fluid)), (SP202: 120BC max.)
MODEL:SP-200
SENSITIVITY ALARM (4). Operation pressure: 100 bar, (SP220: 5 bar max.)
(5). Degree of protection: IP67
(6). Supply voltage: 24Vdc A 20%
(7). Output: Open collector---NPN / PNP, 400 mA max. (with current limiting).
Relay---1A/30Vdc, 0.3A/125Vac (NO or NC),
5A/250Vac max. (NO)
Fig. 3 Fig. 4 Fig. 5
6.Wiring 8.Dimension (G1/2)
40
M12
f70
3-wire 4-wire HEX38
HEX38 f70
M12
3 Blue 1 Brown 46
) ) + 46
78
78
) Brown ) Blue
59.5
N PN 1 3 40.5 72.5
+
PG 106
4 ) Black 2 ) Green M12 32
32
NO 4 Black
Fig. 6, NPN output type wiring ) 31 L=31
41
31 G1/2"
G 1/2" 31 G1/2" 1/ 2?PF
1/2 ?PF L=31 19.8 f7.4
f7.4 f7.4 f38
Fig. 9, 1A Relay output type wiring (NO) f7.4
f38
f7.4
30
Fig. 13 SP200 Fig. 14 SP202 Fig. 15 SP210 5A(Relay) Fig. 16 SP220 Fig. 17 SP170 5A(Relay)
1 Brown 1 Brown
) + ) +
PNP 3 ) Blue 3 ) Blue
9.Maintenance
4 ) Black 2 ) Green
NC 4 Black
Fig. 7, PNP output type wiring ) Under normal operating conditions, no special maintenance is required. Contamination on the probe
of SP could change its thermal property. If necessary, using a suitable solvent to clean the surface of
Fig. 10, 1A Relay output type wiring (NC)
the probe periodically.
After cleaning process, re-checking alarm setting and leakage of sealing ring is recommended.
5-wire 5-terminal
10.Warranty
Red NO
+
Black C The warranty of SP is described as following:
Relay
NC
Period of warranty: 12 months after receiving.
White
COM Validation of warranty: The warranty is valid only when the SP is using under normal operating
Yellow condition specified in the specifications of SP.
NC
Blue Our warranty: Replace with new SP or repairing.
NO
Fig. 8, 5A Relay output type wiring Fig. 11, 5A Relay output type wiring
※Subject to change without notice
※During installation SP170,it is recommended to use spacer with material such as NBR,
PTFE etc.Dimension are as follows.
7.Pin assignment
21mm
2
2mm
3 1 28mm