Odf&fat (02081402, 02081405. 02081407)
Odf&fat (02081402, 02081405. 02081407)
Odf&fat (02081402, 02081405. 02081407)
GPX147-FAT3101
V100R001C01
Product Description
Issue 07
Date 2010-07-07
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Introduction.................................................................................................................................1-1
1.1 Positioning ....................................................................................................................................................1-1
1.2 Benefits .........................................................................................................................................................1-2
2 Architecture .................................................................................................................................2-1
2.1 Case...............................................................................................................................................................2-1
2.2 Installation Accessories .................................................................................................................................2-4
4 Technical Specification.............................................................................................................4-1
4.1 Parameters .....................................................................................................................................................4-1
4.2 Performance Indexes .....................................................................................................................................4-4
4.3 Standard Compliance ....................................................................................................................................4-4
1 Introduction
1.1 Positioning
GPX147-FAT3101 series of fiber access terminal is located at the user access point of
FTTH-ODN for connecting the distribution optical cables and drop cables, direct connection,
branching and protection of optical fibers.
Figure 1-1 shows the location of the GPX147-FAT3101 (hereafter abbreviated as FAT3101) in
the ODN network.
1.2 Benefits
The FAT3101 features flexible application, reasonable design, easy and durable operation.
Flexible application
z Rich capacity, adaptable to different indoor and outdoor application scenarios.
z Direct connection and branching of an optical cable is available.
z Flexible Fiber Connection: The product supports fiber splicing and fiber mechanical
connection. With the Huawei-patented device for fixing fiber connection points, users
can reliably fix various splicing protection tubes and fiber mechanical connection
terminals on the same FAT.
Reasonable Design
z The separate splicing tray is left to store redundant direct connection optical fibers.
z Independent area is designed for routing drop cables.
2 Architecture
2.1 Case
By installation location, the FAT3101 involves indoor and outdoor models: FAT3101D
(outdoor)and FAT3101(indoor).
z The FAT3101D includes the rubber sealing loop, as shown in Figure 2-2.
z The FAT3101D has three cable inlet and outlet holes, the cable outlet hole at the upper
side of the FAT3101D has been sealed, so the direct connection optical fibers can only
leave out from the cable outlet hole at the lower side of the FAT3101D.
z The FAT3101D case supports the entry of flat drop cable (2 mm x 3 mm) and round drop
cable (Ф5 mm).
z The general optical cable holes can support the inlet and outlet of the general cable with
a diameter less than 15 mm.
z The FAT3101 does not include the rubber sealing loop, as shown in Figure 2-4.
z The FAT3101 has four cable inlet and outlet holes, the direct connection optical fibers
can leave out of from the cable outlet hole either at the upper side or at the lower side of
the FAT3101.
z The FAT3101 case supports the entry of flat drop cable (2 mm x 3 mm).
z The general optical cable holes can support the inlet and outlet of the general cable with
a diameter less than 15 mm.
The pole-mounted accessories can be installed on a pole with a diameter from 30 mm to 120 mm.
The outdoor FAT3101D can also be installed on the pole, as shown in Figure 3-2.
The distribution optical cable is led in from the cable inlet hole at the bottom and led out from the cable
outlet hole at the bottom.
Figure 3-4 Indoor FAT3101 installed in the corridors of a building with multiple floors
2. In the other application, the indoor FAT3101 is installed in the corridors of a high-rise
building. The distribution optical cables in a high-rise building are routed from the lowest
floor to the highest one. In this case, optical cables are routed into the FAT3101 through the
cable inlet hole at the bottom and then routed out of the case through the cable outlet hole at
the top or the bottom. The FAT3101 implements the branching and direct connection of
optical cable so that the distribution optical cables are connected to terminal flexible optical
cables entering each family, as shown in Figure 3-5.
4 Technical Specification
4.1 Parameters
Parameters include specification parameters and environment parameters.
Outdoor FAT3101D
FAT31 296 × On the 6 2.6 PA Plastic ABS 1.
01D-6 238 × outdoor NT materials Equipp
70 wall or ON , ed
FAT31 pole 12 E satisfyin with
01D-12 Co the
FAT31 18 ol g RoHS g
01-18 Gr protect
ay ion
3C tube. If
mecha
nical
connec
tion is
needed
,
please
order
the
mecha
nical
splicer
s
separat
ely.
Take the GPX147-FAT3101D-6 as an example to describe the naming rules of the GPX147-FAT3101
products: "GPX147" indicates a Huawei cable distribution product; "FAT" means Fiber Access Terminal;
"3" means the product is installed on the wall; "1" means that the product is not configured with cable
distribution function; "01" is the model of the product, numbered from 01; "D" refers to outdoor (if no
"D" appears here, it refers to indoor); "6" indicates that the user capacity is 6 cores.
GB/T 2423.1-2001 Basic Environmental Testing for Electric and Electronic Products -
Part 2 - Testing Method - Test A: Low Temperature
GB/T 2423.2-2001 Basic Environmental Testing for Electric and Electronic Products -
Part 2 - Testing Method - Test B: High Temperature
GB/T 2423.4-1993 Basic Environmental Testing Process for Electric and Electronic
Products - Test Db: Alternative Moist Heat Test
GB/T 2423.9-2001 Basic Environmental Testing Process for Electric and Electronic
Products - Test Cb: Constant Moist Heat Test
GB/T 2423.17-1993 Basic Environmental Testing Process for Electric and Electronic
Products - Test Ka: Salt Spray Test
GB/T 2828.1-2003 Count Sampling Inspection Process - Part 1: Sampling Plan for
Batch Inspection by Acceptance Quality Limit (AQL)
GB/T 2829-2002 Count Sampling Procedures And Tables for Periodic Inspection
(Applied to Inspection of Process Stability)
GB/T 3873 General Specifications for Products Packaging of Communication
Equipment
GB/T 9286-1998 Color Paints and Varnishes-Cross Cut Test for Films
GB 4208-1993 Shell Protection Level (IP Code)
GB 5095.2-1997 Basic Testing Process and Measurement Method for
Electromechanical Components of Electronic Equipment - Part 2 -
General Test, Electricity Continuity and Contact Impedance Test,
Insulation Test and Electricity Stress Test
GB/T 7424.1-2002 General Standard for Optical Cables - Part 2: Basic Test Method
for Optical Cables
GB/T 12507.1-2000 Connectors of Optical Fibers and Optical Cables - Part 1: General
Standard
GB/T 15972-1998 General Standard for Optical Fibers
This chapter describes the acronyms and abbreviations mentioned in this document.