FLOW MEASUREMENT INSTRUMENTS TABLE OF

CONTENTS
55

Level Measurement
Instruments
When you need mechanical flow instruments or the most precise non-contacting flow sensors and monitoring systems,
look to Lesman. Whatever the media or application, we can help you. When you’re not sure what instrument works best,
you can use our collection of application datasheets. Fill in your process information, fax it to Lesman, and we’ll put your
process through an engineering review with our manufacturer partners to come up with the exact instrumentation to
meet your needs.

Flow Measurement
Instruments
Prices See
Start at Page

Coriolis Flow
Honeywell VersaFlow Coriolis Mass Flowmeters Call 64
Siemens SITRANS FC Coriolis Mass Flowmeters Call 70

Differential Pressure and Multivariable Mass Flow

Pressure Transmitter
Honeywell SMV3000 Smart Mass Flowmeter Call 63
Pitot Tubes, Venturi Tubes, and Bluff Body Flowmeters Call 62
Orifice Plates and Orifice Flange Unions Call 62

Electromagnetic Flow
Honeywell VersaFlow Electromagnetic Flowmeters Call 64
Siemens SITRANS FM MAGFLO Electromagnetic Flowmeters Call 66

Mechanical Flow

Temperature Sensors
GEMS Flowmeters and Switches $55.00 58

and Transmitters
Kobold Flow Switches $87.00 56
Kobold Temperature Compensated Switches and Transmitters $366.00 57
RCM Direct Reading Flowmeters for Liquids, Air, or Gas $470.00 59

Thermal Mass Flow


Thermal Instrument Company Inline and Insertion Mass Flowmeters Call 61

Turbine Flow

Wireless Sensing and


Turbine Flowmeters for Gas and Liquid Service Call 60

Communications
Ultrasonics for Pipes and Open Channel Flow
Siemens F US Clamp-On Ultrasonic Flowmeters $3509.00 72
Siemens SITRANS LUT440 Open Channel Flow Monitor $1936.00 76

Vortex Flow
Honeywell VersaFlow Vortex Flowmeters Call 65

Reference Materials
Analytical Instruments

Table of Viscosities of Common Substances 489


and Systems

Prices in this catalog are current at the publication date, and are subject to change without notice.
Due to manufacturer agreements, some products may not be available in all Lesman markets or
geographic areas.
FLOW: Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
56

V 01.2018
MECHANICAL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

Flowmeters, Switches and Visual Flow Indicators


PPS Polysulfone Paddle Flow Switch BVO Series Flowmeter/Switch
Switch: Hermetically sealed, magnetically actuated contact;
15VA max., 0.5A max., 250V max. capacity
for Water-Like Liquids
Pressure: 145 PSI max.; 1.45 PSI max. drop Accuracy: ±12% full scale; Repeatability: ±2% FS
Adjustment Accuracy: ±20% Temperature: -10° to 212° F
Switch Repeatability: ±3% Pressure: 145 PSIG max.
Flow Measurement

Maximum Temperature: 225° F Flow Direction: Vertical, up


Switch Characteristics: N/O switch: 240 VAC/200
Instruments

Material: NEMA 4 Polysulfone, stainless steel, ceramic magnet


VDC max. , 1.5 Amp AC/1.0 Amp DC max., 50 VA,
Connections: Thread: 1” NPT; Electric: DIN 43650 plug 50 W max. power, 4-8 mm float travel hysteresis.
SPDT switch: 240 VAC max. , 0.8 Amp AC max. , 30
Pipe Cutoff mark Switch Point (GPM Water) VA max. power, 4-8 mm float travel hysteresis.
Bore “L” Approx. Turn-On Turn-off
1” 0.9” 9.5 5.0
1 1/4” 1.1” 9.5 5.0 Model Selection Guide
1 1/2” 1.4” 14.5 9.5 Water Fitting Pressure Loss Catalog
2” 2.0” 19.0 9.5 Body Range Size @ Max. Flow Number Price
2 1/2” 2.4” 24.0 14.5
Brass 0.1 to 1.0 GPM 1/4” NPT 0.9 PSIG BVO-6102 $283.00
3” 2.9” 28.5 19.0
Brass 1.0 to 5.0 GPM 1/2” NPT 1.1 PSIG BVO-6116 283.00
Pressure Transmitter

Model Selection Guide Please allow 3-4 weeks for delivery. 304 SS 0.1 to 1.0 GPM 1/4” NPT 0.9 PSIG BVO-6202 541.00
304 SS 1.0 to 5.0 GPM 1/2” NPT 1.1 PSIG BVO-6216 541.00
Switch Type Catalog Number Price
Optional SPDT Contact Suffix -U 0.00
Normally Open, SPST, 15VA Max. PPS-3106 $124.00
Normally Closed, SPST, 15VA Max. PPS-3105 124.00

Insertion Paddle/Bellows Flow Switch for Liquids


• Position-Independent Installation Model Selection Guide Please allow 3-4 weeks for delivery.
• Max. Pressure 160 PSI/450 PSI, Media De-Actuating Actuating Pipe Catalog Catalog
Temperature Sensors

Temperatures to 250° F GPM H2O GPM H2O Size Number Price Number Price
and Transmitters

Kobold FPS paddle bellows flow switches 2.6–8.8 4.4–9.3 1”


3.5–12.3 5.7–13.2 1.25”
are used wherever reliable control for mini- 4.8–16.3 7.5–17.6 1.5”
mum or maximum liquid flow is required. 9.7–25.1 13.7–26.9 2”
The flowing medium exerts a force on the 11.9–28.6 17.6–30.2 2.5” FPS-5100 $277.00 FPS-5200 $368.00
paddle to actuate a micro switch. The in- 18.9–47.1 27.3–50.2 3” (Brass) (SS)
strument internals are separated from the 50.2–122.0 64.7–127.7 4”
process by the bellows, making the FPS an 100.8–234.7 125.1–244.8 5”
158.1–360.0 189.8–385.0 6”
excellent choice for dirty media. 319.7–729.6 374.7–759.5 8”
Wireless Sensing and

Looking for a compact flow switch for All Metal Paddle Flow Switch
Communications

non-viscous liquids?
Flow Speed: 12 ft/sec max., adjustable flow ranges
Kobold’s KAL-D is a compact all-stainless calorimetric
Contact: Reed switch SPST, N/O or N/C; 50VA, 50 watt,
thermal flow switch for use in small spaces and 1/4” NPT
250V, 1.5A max ratings
fittings. It has a switching range from 0.15 to 6.6 feet per
second, works in pressures to 580 PSIG, and temperatures Pressure: 1450 PSI max.
to 176° F. KAL-D can even be used in Clean-in-Place ap- Temperature: 230° F max.
plications with short-term temperature limits of 250° F. Materials: Housing: NEMA 4, Glass-reinforced Polyamid;
KAL-D prices start at $357.00. Paddle, Leaf Spring, Beam: SS; Locking Plate, Screws: Brass;
O-Ring: Buna-N
Analytical Instruments

her Model Selection Guide


Searching for ot rs
Please allow 3-4 weeks for delivery.
cato
Kobold flow indi
Switch ON Switch OFF NPT Catalog
and Systems

GPM H2O GPM H2O Conn. Number Price


ll
and switches? Ca Brass paddle 0.9 - 1.3 0.6 - 1.2 1/4” PSR-5105 $87.00
en t
Lesman for curr flow switch, 1.3 - 2.1 1.0 - 2.0 1/2” PSR-5115 87.00
bi y.
lit
pricing and availa
5’ PVC cable 3.0 - 4.0 2.2 - 3.0 3/4” PSR-5120 87.00
3.2 - 5.0 2.4 - 4.5 1” PSR-5125 99.00
4.9 - 8.5 3.8 - 7.8 1-1/4” PSR-5132 118.00
9.2 - 15.0 7.9 - 14.3 1-1/2” PSR-5140 130.00
Call for stainless steel bodies or larger pipe sizes.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan FLOW:
57

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
MECHANICAL

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
What’s the Right Flow Technology for Your Process?
Need help figuring out which flow measurement instrumentation to use in your process? Start with the reference charts
below. Find your media type to help narrow down your choices. Then, take a look at the comparative specifications in the
chart at the right. Depending on your application, there may be more than one technology for you.

Upstream Pipe Diam.

Permanent PSI Drop


Key

Repeatability (%)
Turndown Ratio

Accuracy (%FS)
▲ Excellent: Recommended. Key

Viscous Liquid

Flow Measurement
Relative Cost
H High
Clean Liquid

u Fair: Works, but depends


Dirty Liquid

Cryogenics
Corrosives
on the application. M Medium

Clean Gas

Instruments
Dirty Gas
Slurries
▼ Poor: Do not use. L Low

Steam

Sizes
Technology Media Type Technology/Spec.
Coriolis Flowmeter ▲ ▲ ▲ ▲ ▲ u u u u Coriolis Flowmeter 25:1 0.1-6” 0.15% 0.1% 0 L H
DP Mass Flowmeter ▲ ▲ ▲ u u ▲ ▲ ▲ ▼ DP Mass Flowmeter 40:1 — 0.1% 0.1% — — H
DP Orifice Plate ▲ u u ▲ ▼ ▲ u ▲ ▲ DP Orifice Plate 4:1 >1” 1% 0.1% 10-30 H L
DP Pitot Tube ▲ ▼ ▼ u ▼ ▲ u ▲ ▼ DP Pitot Tube 4:1 0.5-72” 0.75% 0.1% 10 L L
DP Wedge ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▼ DP Venturi 10:1 0.5-72” 1% 0.1% 10 M L
DP Venturi ▲ ▲ u u ▼ u u ▲ ▼ DP Wedge 10:1 0.5-30” 3% 0.5% 12 H H
Fluidic Oscillatory ▲ u ▲ u ▲ ▼ ▼ ▼ ▲ Fluidic Oscillatory 15:1 1-3” 1.5% 0.2% 10 L H

Pressure Transmitter
Magnetic Flowmeter ▲ ▲ ▲ ▲ ▲ ▼ ▼ ▼ ▼ Magnetic Flowmeter 10:1 >0.1” 0.5% 0.2% 5 L M
Paddlewheel ▲ ▼ u u ▼ u u ▼ ▼ Paddlewheel 3:1 0.1-1.5” 2.5% 1% 0 H L
Positive Displacement ▲ ▲ ▲ u ▼ ▲ u ▼ u Positive Displacement 20:1 0.5-6” 1% 0.3% 0 H M
Rotameter ▲ ▼ u u ▼ ▲ ▼ u ▼ Rotameter 5:1 0.2-3” 4-8% 2% 0 M L
Thermal Dispersion ▲ u u u u ▲ ▲ ▼ u Thermal Dispersion 100:1 0.2-72” 0.5% 0.2% 10 L H
Turbine Flowmeter ▲ ▼ u u ▼ ▲ u ▲ u Turbine Flowmeter 10:1 >0.25” 0.5% 0.1% 10-20 H H
V-Notch ▲ u ▼ u u ▼ ▼ ▼ ▼ 50:1
Vortex Flowmeter ▲ u u u ▼ ▲ u ▲ ▼ V-Notch 300:1 — 2-5% 2% 4H 0 L
Weir ▲ u ▼ u u ▼ ▼ ▼ ▼ Vortex Flowmeter H >1” 1% 0.2% 20-30 M L
Weir 300:1 — 2-5% 2% 4H 0 L

Viscosity table for common


substances, page 489.

Temperature Sensors
and Transmitters
Temperature-Compensated Flow Switches and Transmitters
KAL-K Flow Switch/Trend Indicator for Liquids and Oils
Features Approximate Switch Point (GPM) per Pipe Diameter
• No moveable parts Nominal Water Nominal Water Nominal Water
ID Range ID Range ID Range
• Minimal pressure loss
1/2” 0.3 – 5.0 2” 3.1 – 55 8” 50 – 900

Wireless Sensing and


• Simple media adjustment 3/4” 0.5 – 8.9 2-1/2” 4.4 – 80 10” 78 – 1400

Communications
• Temperature compensation 1” 0.8 – 14 3” 7.9 – 140 12” 110 – 2000
1-1/4” 1.1 – 20 4” 12 – 220 16” 200 – 3600
and switch point stability 1-1/2” 2.0 – 35 6” 28 – 500 20” 310 – 5600
• Unaffected by viscosity changes —
even for the smallest flow velocities!
Model Selection Guide
• IP65 enclosure — insensitive to dirt
Description Catalog Number Price
• Designed for minimal pipe intrusion
KAL-K Flow Switch for Liquids, 24 VDC Power
Specifications 304 SS Wetted Parts, 1/2” NPT KAL-4215 $366.00
Measuring Range: Water: 0.05 to 2 m/sec.; Oils: 0.1 to 4 m/sec. approx. 316-Ti SS Wetted Parts, 1/2” NPT KAL-4315 414.00
316-Ti SS Wetted Parts, 3/4” NPT KAL-4320 424.00
Analytical Instruments

Operating Conditions: Pressure: 1450 PSIG max; Temperature: ‑10°–185° F


316-Ti SS Wetted Parts, 3A Sanitary KAL-4340-S 508.00
Switching: Adjustment: By potentiometer; Selectable output: NPN or PNP,
and Systems

open collector; Current: 400 mA max.; Voltage: 24 VDC max.; Status indica- KAL-K Flow Switch, 110 VAC Power, SPST Dry Contact Output for Liquids
tor: Bicolored LED 304 SS Wetted Parts, 1/2” NPT KAL-4215-P03R 543.00
Power: Supply voltage: 24 VDC ±10%; Current draw: 300 mA max. 316-Ti SS Wetted Parts, 1/2” NPT KAL-4315-P03R 591.00
316-Ti SS Wetted Parts, 3/4” NPT KAL-4320-P03R 601.00
Materials: Wetted parts: 304 or 316-Ti stainless steel; Housing: NEMA 4 Nylon
standard, NEMA 7 Al optional Options Fast Response (2.8-6 Sec.) -F 0.00
Quick Disconnect Plug (24 VDC) -M12 93.00
Fittings: 1/2” or 3/4” NPT or 1-1/2” Tri-Clamp®.
Flow Trend Indicator: Eight red LEDs
FLOW: Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
58

V 01.2018
MECHANICAL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

Flowmeters and Switches


RotorFlow® Flow Indicators Gems Shuttle Switches Rise to the Occasion!
RFI is Gems’RotorFlow® at its most basic form — a Fluid, flowing through the switch housing, displaces
bright orange rotor turning with fluid flow. Either a spring-loaded, calibrated shuttle, which is metered
port can be used for incoming flow. relative to a fixed orifice. When flow rate reaches the
Body: Polypropylene, brass, or 316 stainless steel calibrated setpoint, the shuttle moves up to the stem,
actuating the hermetically sealed reed switch. Flow
Other wetted materials: Orange molded Nylon
Flow Measurement

switches respond only to flow — not pressure!


rotor, ceramic rotor pin, polysulfone lens, glass-
Instruments

reinforced polypropylene low flow adapter Occasional Cleanout is a Snap!


Model Selection Guide Remove the bonnet easily without disturbing the
inline body.
Port Flow Ranges (GPM) Pressure Operating Catalog
Size Low* High Max. Temp. ° F Number Price
RotorFlow® RFI Flow Indicator, Polypropylene Body
0.25” 0.1 to 1.0 0.5 to 5.0 100 PSI
0.50” 1.5 to 12.0 4.0 to 20.0 100 PSI
180° Max. 155420
180° Max. 155480
$55.00
55.00 Rugged Flow Switches Deliver
RotorFlow® RFI Flow Indicator, Brass Body Accurate, Reliable Service
0.25” 0.1 to 1.0 0.5 to 5.0 200 PSI 212° Max. 142541 145.00
Pressure Transmitter

0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI 212° Max. 142542 145.00 FS-200 flow switches provide accurate flow
0.75” — 5.0 to 30.0 200 PSI 212° Max. 180392 145.00 detection with 1% repeatability. Bronze and
RotorFlow® RFI Flow Indicator, 316 Stainless Steel Body Teflon® construction delivers long life in water
9/16” 0.1 to 1.0 0.5 to 5.0 200 PSI 212° Max. 174596 185.00 and oil, and fluid temperatures to 300° F.
0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI 212° Max. 173138 185.00 Setpoints are calibrated using water
0.75” — 5.0 to 30.0 200 PSI 212° Max. 181682 215.00 at 70° F on increasing flow with unit in a
horizontal position (lead wires up).

Low Cost Switches for Operating Pressure: 400 PSIG @ 100° F


Operating Temperature: -20° to 200° F
Threaded Plastic Piping Switch: SPDT, 20 vA
Gems FS-500 offers low cost flow monitoring
Temperature Sensors

with a variety of switch actuation points and low Model Selection Guide
and Transmitters

pressure drop. All wetted parts are polypropylene


or stainless steel, making this switch ideal for a wide Flow Bronze Body Stainless Steel Body
range of chemical and temperature requirements. Setting Catalog Catalog
The materials are also NSF or FDA approved for potable Port Size (GPM) Number Price Number Price
water treatment applications including chlorinators, puri- 0.5 27051 $191.00 27059 $569.00
fiers and heaters. 1 27052 191.00 27060 569.00
2 27053 191.00 27061 569.00
Wetted Materials: Housing, Bonnet, Shuttle, Model Selection Guide 3 27054 191.00 27062 569.00
Shuttle Cap: Polypropylene 1” NPT
FS-500 Flow Switch 4 27055 191.00 27063 569.00
O-Ring: Viton® or Buna N 5 27056 191.00 27064 569.00
Catalog 6 27057 191.00 27065 569.00
Spring: 316 Stainless Steel Setpoint Number Price
Wireless Sensing and

8 27058 191.00 27066 569.00


Retaining Clip: PH 15-7 Mo Stainless Steel
Communications

0.25 170231 $71.00 1 27067 365.00 27076 838.00


Maximum Operating Temp.: 0° to 212° F 0.5 170232 71.00 2 27068 365.00 27077 838.00
Setpoint Accuracy: ±20% 1 170233 71.00 4 27069 365.00 27078 838.00
2 175117 71.00 6 27070 365.00 27079 838.00
Switch: SPST, N.O. Pilot Duty 20 VA, 120-240 2.5 170234 71.00 1-1/4” NPT 8 27071 365.00 27080 838.00
VAC or VDC 5 170235 71.00 10 27072 365.00 27081 447.00
Inlet/Outlet Ports: 3/4” Female NPT 12 27073 365.00 27082 838.00
16 27074 365.00 27083 838.00
20 27075 365.00 27084 838.00
General Purpose Switch for Plastic Piping
1.5 27085 447.00 27093 881.00
These Gems FS-400P switches have a noncorrosive, 3 27086 447.00 27094 881.00
clear PVC housing for broad chemical compatibility, and 5 27087 447.00 27095 881.00
Analytical Instruments

are ideal for flow/no-flow detection. 1-1/2” NPT


7.5 27088 447.00 27096 881.00
10 27089 447.00 27097 881.00
and Systems

Materials: PVC, Epoxy, and Buna-N


15 27090 447.00 27098 881.00
Switch: SPST, 20 VA, N.O. at no-flow 20 27081 447.00 27099 881.00
30 27092 447.00 27100 881.00
Model Selection Guide
Connect
Size
Actuation on
Increasing Flow
Pressure
Max.
Operating
Temp (° F)
Catalog
Number Price
Looking for other Gems flow switches or
indicators? Need a different material or port
1/2” NPT* 0.5 GPM ± 20% 120 PSIG 120° 135805 $81.00
size? Call Lesman!
* 3/4” IPS model with 1/2 NPT port installed.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan FLOW:
59

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
MECHANICAL

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Direct Reading Flowmeters
Specifications RCM Series 8000 Flo-Gage® is designed for larger
Accuracy: ±3% full scale pipe sizes and mounts between adjoining flanges
Range: Flow rates to 500 GPM or 4000 SCFM; (ANSI 150#, 300#, DIN PN10, PN16, JIS, AS). Install
Rangeability: 6:1 the Flo-Gage just as you would install an orifice
Mount: Horizontal (standard), flow to the right plate, with flat gaskets and bolts (order separately).
Temperature: 212° F max. , 350° F max. optional Specifications
Pressure: 180 PSIG max., 400 PSIG max. optional

Flow Measurement
Accuracy: ±3% full scale; Repeatability: 1% full scale
Construction: Diecast aluminum housing, glass

Instruments
Range: Flow rates to 3000 GPM liquid or 20000 SCFM
or polycarbonate crystal, bronze body, bronze gas; Rangeability: 6:1
gear movement, Buna-N seals. Other materials
available on request Mount: Horizontal (standard), flow to the right
Options: High/Low alarm relays, 4-20 mA, Operating Conditions: Temperature: 212° F max.,
0-1000 Hz output, digital display for flow rate/ 350° F opt.; Pressure: 180 PSIG max., 400 PSIG opt.
totalization Construction: Bronze body, movement, ABS housing
and crystal, Buna-N seal. Call for other materials
Shown with optional 4-20 mA loop-powered Options: Relay: High/Low alarms; Output: 4-20 mA,
two-wire indicator. Displays 4-1/2 digits for flow 0-1000 Hz frequency. Optional Digital Display.
rate, 8 digits for total­ization. Includes scaled,
Intrinsically safe switches

Pressure Transmitter
open collector output for re­mote totalizer, and
square root extraction for use with W3 solid- available. Call for pricing.
state strain gauge. Call for pricing.

Model Selection Guide


Model Selection Guide for Liquids
Standard mounting is horizontal, (R) designates flow going to the right. For Media Range Fittings Catalog
other configurations, call Lesman. When ordering, please specify media, pres- Type GPM Liquid Flange Size Number Price
sure, and temperature. 0.3 – 2.0 1⁄2” 1⁄2-81-R-02 $470.00
0.4 – 3.0 1⁄2” 1⁄2-81-R-03 470.00
Media NPT Catalog 0.5 – 4.0 1⁄2” 1⁄2-81-R-04 470.00
Type Flow Rate Connection Number Price 0.5 – 6.0 1⁄2” 1⁄2-81-R-06 470.00
0.5 - 6 GPH 1⁄2” 1⁄2-71-R-06-ES $ 580.00 1.5 – 10 1⁄2” 1⁄2-81-R-10 470.00

Temperature Sensors
3.0 - 20 GPH 1⁄2” 1⁄2-71-R-20-ES 580.00 0.5 – 6.0 3⁄4” 3⁄4-81-R-06 530.00

and Transmitters
5.0 - 60 GPH 1⁄2” 1⁄2-71-R-60-ES 580.00 1.5 – 10 3⁄4” 3⁄4-81-R-10 530.00
15 - 100 GPH 1⁄2” 1⁄2-71-R-100-ES 580.00 2.0 – 15 3⁄4” 3⁄4-81-R-15 530.00
0.5 - 4.0 GPM 1⁄4” 1⁄4-71-R-04 470.00 3.0 – 20 3⁄4” 3⁄4-81-R-20 530.00
0.5 - 4.0 GPM 1⁄2” 1⁄2-71-R-04 470.00 2.0 – 15 1” 1-81-R-15 555.00
0.5 - 6.0 GPM 1⁄2” 1⁄2-71-R-06 470.00 3.0 – 20 1” 1-81-R-20 555.00
For 1.5 - 10 GPM 1⁄2” 1⁄2-71-R-10 470.00 5.0 – 40 1” 1-81-R-40 555.00
Liquid 0.5 - 6.0 GPM 3⁄4” 3⁄4-71-R-06 530.00 4.0 – 30 1-1⁄2” 1.5-81-R-30 630.00
1.5 - 10 GPM 3⁄4” 3⁄4-71-R-10 530.00 5.0 – 40 1-1⁄2” 1.5-81-R-40 630.00
3.0 - 20 GPM 3⁄4” 3⁄4-71-R-20 530.00 5.0 – 60 1-1⁄2” 1.5-81-R-60 630.00
3.0 - 20 GPM 1” 1-71-R-20 555.00 15 – 100 1-1⁄2” 1.5-81-R-100 630.00
5.0 - 40 GPM 1” 1-71-R-40 555.00 5.0 – 40 2” 2-81-R-40 730.00
5.0 - 40 GPM 1-1⁄2” 1.5-71-R-40 630.00 5.0 – 60 2” 2-81-R-60 730.00
For
15 – 100 2” 2-81-R-100 730.00

Wireless Sensing and


15 - 100 GPM 1-1⁄2” 1.5-71-R-100 630.00 Liquid

Communications
15 - 100 GPM 2” 2-71-R-100 730.00 20 – 150 2” 2-81-R-150 730.00
30 – 200 2” 2-81-R-200 730.00
5.0 - 40 SCFH 1⁄2” 1⁄2-71-R-40-IES 665.00 30 – 200 3” 3-81-R-200 915.00
15 - 100 SCFH 1⁄2” 1⁄2-71-R-100-IES 665.00 40 – 300 3” 3-81-R-300 915.00
30 - 200 SCFH 1⁄2” 1⁄2-71-R-200-IES 665.00 50 – 400 3” 3-81-R-400 915.00
50 - 400 SCFH 1⁄2” 1⁄2-71-R-400-IES 665.00 60 – 500 3” 3-81-R-500 915.00
1.5 - 10 SCFM 1⁄4” 1⁄4-71-R-10-I 555.00 40 – 300 4” 4-81-R-300 995.00
4.0 - 30 SCFM 1⁄4” 1⁄4-71-R-30-I 555.00 50 – 400 4” 4-81-R-400 995.00
1.5 - 10 SCFM 1⁄2” 1⁄2-71-R-10-I 555.00 50 – 600 4” 4-81-R-600 995.00
For Air 4.0 - 30 SCFM 1⁄2” 1⁄2-71-R-30-I 555.00 100 – 800 4” 4-81-R-800 995.00
or Gas 5.0 - 60 SCFM 1⁄2” 1⁄2-71-R-60-I 555.00 50 – 600 6” 6-81-R-600 1200.00
5.0 - 60 SCFM 3⁄4” 3⁄4-71-R-60-I 615.00 100 – 800 6” 6-81-R-800 1200.00
15 - 100 SCFM 3⁄4” 3⁄4-71-R-100-I 615.00 150 – 1000 6” 6-81-R-1000 1200.00
Analytical Instruments

30 - 200 SCFM 3⁄4” 3⁄4-71-R-200-I 615.00 300 – 2000 6” 6-81-R-2000 1200.00


30 - 200 SCFM 1” 1-71-R-200-I 640.00 50 – 600 8” 8-81-R-600 1650.00
and Systems

50 - 600 SCFM 1-1⁄2” 1.5-71-R-600-I 715.00 150 – 1000 8” 8-81-R-1000 1650.00


50 - 600 SCFM 2” 2-71-R-600-I 815.00 300 – 2000 8” 8-81-R-2000 1650.00
150 - 1000 SCFM 2” 2-71-R-1000-I 815.00 400 – 3000 8” 8-81-R-3000 1650.00
400 - 3000 SCFM 3” 3-71-R-3000-I 1000.00 Options: Add as suffix to catalog number
Options: Add as suffix to catalog number Hi/Low alarm setpoint relays (Req 24 VDC power) –X 350.00
Calibrate for specific gravity other than water -C 85.00 4-20 mA loop-powered output –W 600.00
Hi/Lo alarm setpoint relays (Req. 24 VDC power) -X 350.00 0-100 Hz output –Y 600.00
NEMA 4X Gasketed Meter Case -D 50.00 For gas applications –I 85.00
FLOW: Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
60

V 01.2018
TURBINE Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

Turbine Flowmeters for Gas and Liquid Service


Low Cost Industrial Flowmeters for Liquid Measurement
Features Specifications
• Simple construction allows for rugged Flowmeter Size: 1/4” to 3” diameter
and dependable service at low cost Repeatable Flow Range: 0.25 to 800 GPM
• Off-the-shelf delivery; Companion Accuracy and Linearity: ±1.0% reading or better
Flow Measurement

electronics available in 10 to 15 days Repeatability: ±0.1% reading or better


Instruments

• Outstanding accuracy at low cost, Temperature: ‑450° to 350° F with UB bearing; ‑450° to
without compromise in design 450° F with C bearing
Signal Output: 10 MVRMS or greater with 10KΩ load at
minimum flow rate
Materials: 316 stainless steel; Rotor: 17.4 PH stainless steel;
Bearings: 440C stainless steel or hard carbon composite

For Gas Service For Liquid Service


Pressure Transmitter

Features Features
• Radio frequency (RF or MCP) pickup • Threaded or flanged
coils provide wide rangeability process connections
• Four blade angles available • Outstanding accuracy
(15°, 20°, 25°, and 30°) per • Provides wide flow ranges
flowmeter size for optimum (10:1 to 100:1 turndown
performance ranges available)
• Shielded, self-lubricating ball • Wide variety of process
bearings provide extended life connections and
Temperature Sensors

construction materials
The design of these turbine gas meters minimizes drag effects, which
and Transmitters

results in wide ranges and long-term accuracy. All meters are equipped • Operates over wide range
with special self-lubricating, long-life ball bearings and low-drag, mag- of temperatures and
netic, modulated carrier or pickups. pressures
Gas turbine flowmeters are available with standard flanged, 37° flared,
NPT, or special end fittings. Hazardous and weatherproof coil enclosures Specifications
are available. Size: 1/4” to 12” diameter
Linear Range: 0.35 to 12,000 GPM
Specifications Overrange: 150% of maximum flow (intermittently)
Flowmeter Size: 1/2” x 1/4” to 12” diameter Linearity: ±0.5% reading (±0.25% typical) over tabulated linear flow range
Linear Range: 0.15 to 12,000 ACFM
Wireless Sensing and

Repeatability: ±0.1% (±0.05% typical) over tabulated repeatable range


Communications

Overrange: 150% of maximum flow (intermittently) Pressure Drop: 4 to 5 PSI at maximum linear flow rate at one CSTK
Linearity: ±1% reading Turndown: 10:1 to 100:1
Repeatability: ±0.25% over usable range Temperature: ‑450° to 450° F; High temperature option to 850° F
Temperature: ‑450° to 350° F, to 400° F intermittent heat End Fittings: NPT, MS flared, and flanged; Others available
Bearings: Ceramic hybrid ball bearings only Bearings: Ceramic hybrid ball bearings; Sleeve bearings in tungsten carbide;
Materials: 316 SS. Other materials available for corrosive applications. Teflon and hard carbon composite available
End Fittings: MS flared and flanged styles recommended Materials: 316 SS. Other materials available for corrosive applications.

Need help with turbine flowmeters?


Analytical Instruments

Fill out the application datasheet from


and Systems

Lesman.com/datasheets/ and fax it


back to Lesman.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan FLOW:
61

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
THERMAL

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Thermal Dispersion Mass Flowmeters
Great for Specifications
m et ha ne mass flow Accuracy: Better of ±1% full scale or 4% reading; Repeatability: Better than
applications! 0.2% reading; Linearity: 0.5%
Temperature Limits: ‑20° to 350° F; Calibrated Temperature Range: ±50° F
Pressure Limits: 0 to 1200 PSI (Max. pressure ratings depend on pipe size.)
Pressure Range: Liquids: Unlimited; Gases: 20 atmospheres

Flow Measurement
Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical,
4 to 8 seconds worst case

Instruments
Pressure Drop: Negligible, completely unobstructed flow path
Viscosity: Up to 5000 cps
Flow Rate: (Volumetric flow units for gases should be expressed in standard
or normal units.) Liquids: 0.003 grams/min minimum full scale; Gases: 2 SLPM
minimum full scale. Maximum determined by pipe capacity.
Model 600-9 Inline Design Flow Range: 10:1 (100:1, 1000:1, multiple ranges available)
The Model 600-9 ther­mal mass flowmeter provides reliable, accurate Flow Element: Meets NEMA 4, 7, and 9 explosion-proof requirements. Electrical
flow measurement with no obstructions to the actual flow path. It handles connection: 1/2”; Construction: 316 SS standard (316 SS, 304 SS Hastelloy®,
liquids, slurries, gases, and homogeneous solids through a wide range Monel, Inconel®, tantalum, titanium, gold, platinum, nickel, Carpenter 20®,

Pressure Transmitter
of flow rate, temperature, pressure, viscosity, abrasiveness, or chemical glass); Connections: Flanged, Swagelok®, NPT, VCR, VCO, Tri-Clamp, concen-
compositions. tric reducer, flared, sanitary, high pressure fittings, wafer, barbed, welded,
The 600-9’s sensor is built into the meter’s outer surface and is com- others; Coatings: Teflon®, tungsten, carbide, HMF®
pletely protected from adverse proc­ess conditions. The spool matches Remote Flow Transmitter: Model 9200: Panel or wall mount; Model 926A:
the actual flow pipe in dimensions and construction material, and is NEMA 4 JIC type; Model 926B: NEMA 4, 7, and 9 explosion-proof. Others
impervious to fluid, as is the rest of the line. available upon request
System electronics include the flow analyzer, temperature compensa- Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC,
tor, and signal conditioner to provide a linear output directly proportional 10‑50 mA DC, pulse output)
to mass flow. An optional output provides continuous temperature Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo
measurement. alarm setpoints, bidirectional flow, temperature output, multiple ranges

Need help with thermal dispersion mass flowmeters?

Temperature Sensors
ebsite for
Call or visit our w ion.

and Transmitters
at Fill out the Thermal Instruments application datasheet from
more inform www.Lesman.com/datasheets and fax it back to Lesman.

Model 62-9 Insertion Design


The Thermal Model 62-9 flow probe Specifications
is designed to measure the flow rates of Flow Range: 10:1 (100:1, 1000:1, multiple ranges available)
gases, liquids, or slurries in stacks, irregularly
shaped lines, and process ducts. Unlike Flow Limits: (Volumetric flow units for gases should be expressed in standard
or normal units.) Liquids: 0.02 FPS to 20 FPS FS; Gases: 40 SFPM to 15000
other probe flowmeters, the 62-9 has no
SFPM FS. Maximum determined by pipe capacity.

Wireless Sensing and


apertures that can become clogged with

Communications
par­ticles or distorted by heat. The sensing Accuracy: Better of ±0.5% full scale or 2% reading. Calibrated by weight or
element is located on the probe’s inside volume (0.5% FS). Repeatability: Better than 0.2% reading; Linearity: 0.5%
leading edge and has no contact with the Temperature Limits: ‑20° to 1100° F; Calibrated Temperature Range: ±50° F
flow stream. Pressure Limits: 0 to 60000 depending on size PSI
The 62-9 can be made of pipe or tubing Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical,
using any metal compatible with the flow stream 4 to 8 seconds worst case
of a given application. It can also be built with Viscosity: Up to 5000 cps
extra length, so it can be inserted through a gate
valve and packing gland. This will allow easy Flow Element: Meets NEMA 4, 7, and 9 explosion-proof standards. Con-
struction: 316 SS standard; Connections: Flanged, Swagelok®, NPT sanitary
insertion and removal while the pipe is in use.
Tri-Clamp, hot tapping, retractable, saddle mount; Coatings: Teflon®, HMF®,
Analytical Instruments

The thermal probe’s electrical connections Nedox®


can be made either in a gasketed-type conduit Remote Flow Transmitter: Model 9200: Panel mount or NEMA 4 box; Model
and Systems

or an explosion-proof conduit. For applications 926A: NEMA 4 JIC; Model 926B: NEMA 4, 7, and 9 explosion- proof.
over 350° F, the sensors are made of platinum
embedded in a ceramic matrix, securely bonded Pipe Size: 1” minimum
to the pipe’s inside diameter. An additional Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC,
temperature sensor can also be installed, as 10‑50 mA DC, pulse output)
well as independent circuitry to provide fluid Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo
temperature readout signals. alarm setpoints, bidirectional flow, temperature output, multiple ranges,
flow profile, multipoint, averaging
FLOW Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
62

V 01.2018
ELEMENTS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

Orifice Plates, Flange Unions, and Pitot Tubes


Please allow 10 days for delivery. Other Flow Elements Available
If you need your order faster, just let us know.
In most cases, we can arrange for overnight
from Lesman
or second-day shipping. Or, we’ll work with Pitot Tubes
you to arrange delivery by local messenger Inline sensors for measuring flow in pipe
service. Same-day shipping is available for a lines from 1/2”to 3”nominal size. Uses two
Flow Measurement

small premium. averaging probes of equal area to sense


differential pressure loss while providing
Instruments

Paddle-Type Orifice Plates minimum permanent pressure loss.


Probe or insert-type sensors for measur-
Build a Paddle Type Orifice Plate Part Number ing flow in pipelines from 3” to 24”, using
Full
equal area double averaging pitot tubes
Pipe Flange Face Plate Plate Weep for low permanent pressure loss.
Size Rating Flange? Thickness Material Bore Style Hole?
Venturi Flow Elements
____ __ __ 01 __ C _ Herschel Type
See See Yes=FF 1/8” 304SS=04 Concen- Drain or Classic style Venturi tube designed
Pressure Transmitter

Chart Chart No= Blank 316SS=16 tric Vent=W in accordance with ASME or ISO stan-
Below Below No=Blank dards and offers a constant degree
What bore size do you need? _________________________________________ of accuracy and high repeatability.
Not sure what bore size you need? We can calculate it for you. ($35 flat fee.) Venturi-Nozzle Type
If you need a drain or vent, specify Pipe Schedule or ID: ____________________ Design uses the classical ASME and ISO
standards for highest accuracy, predict-
Raised Face Weld Neck ability, and repeata­bility. Flow condition-
ing gen­erated by unique hydraulic shape
Orifice Flange Unions provides a stable signal in a wide range of flows.
All raised face flange unions are made of A105 carbon steel and include Low-Loss Design (Short-Form)
nuts, bolts, and 1/16” gasket. Design provides proven field per­formance in a variety
Temperature Sensors

of applications. Low installation cost due to short laying


and Transmitters

Build a Raised Face Weld Neck Orifice Flange Part Number length, reduced operating costs, and a wide range of sizes
Pipe Flange Material Face Flange Pipe and materials add up to the right choice for your needs.
Size Rating Grade Style Style Schedule Hardware
Bluff Body Differential Pressure Flowmeters
____ __ CS R WN 40 C
The bluff body flowmeter is the only differential pressure flowmeter
See 300#=03 A105 Raised Weld Schedule Complete that fully conditions the flow prior to
Chart 600#=06 Carbon Face Neck 40 with Nuts, measurement. It’s ideal for lines with
Below Steel Bolts, and limited straight piping. This flowmeter
(No 150#) Gaskets provides repeatable accuracy up to
±0.5% flow rate, even under the most
difficult flow conditions, and over a wide
Wireless Sensing and

Pipe Size and Flange Rating Options range of Reynolds numbers.


Communications

(1) Select Your Pipe Size Because this meter can accurately
Pipe Size Code Pipe Size Code Pipe Size Code measure disturbed flow, it doesn’t re-
0.5” 0050 3” 0300 14” 1400 quire the upstream or downstream straight pipe runs of many other
0.75” 0750 4” 0400 16” 1600 flowmeters; so, it can fit where other flowmeters can’t because of
1” 0100 5” 0500 18” 1800 limited space or weight requirements..
1.25” 0125 6” 0600 20” 2000
Left: Precision flow tube, Right: Insertion weld-on saddle.
1.5” 0150 8” 0800 24” 2400
2” 0200 10” 1000 30” 3000
2.5” 0250 12” 1200 36” 3600
(2) Specify the Flange Rating
Analytical Instruments

Flange Code Flange Code Flange Code


150# 01 300# 03 600# 06
and Systems

Call, fax, or e-mail your completed part number to Lesman


for a quote on price and delivery. Prices are valid for two
weeks from the quote date.

Need help finding the flow element you need? Fill out the application datasheet from
www.Lesman.com/datasheets and send it to Lesman for engineering review.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan MULTIVARIABLE
63

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
TRANSMITTER

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Smart Multivariable Flowmeter for Gas and Steam
Looking for differential pressure smart
transmitters for your flow applications?
SMV3000 See pages 86 to 89.
Ranges
Differential Pressure:
±400” H2O Ordering Instructions

Flow Measurement
Absolute Pressure: 0 to 750 PSIA Make one selection from each table section below. Check any restriction letters

Instruments
Process Temperature: or notes (E.g.: N3) to be sure the unit is available. A finished catalog number looks
-328° to 842° F like this: SMA110-E1A-00000-S2,MB,F1C3-XXXX

Model Selection Guide


Catalog Avail-
Description Number ability Price
Differential Pressure Range Pressure Range
Features 0”-1” / 25” H2O 0-100 PSIA SMA110 ↓ $2939.00
0"-1" / 400" H2O 0-750 PSIA SMA125 ↓ 2873.00
• Single sensor measures absolute and differential pressure
scon 400"ed
ti/ nu this
Honeywell has di sman
0"-1" H2O 0-3000 PSIG SMG170 ↓ 2938.00
from one pipe intrusion r
ll Le fo

Pressure Transmitter
Process Vent/Drain Barrier
• Calculations for volumetric or mass flow prod rate, t. Plea
uclinear or se ca Head
t,
Valve, Plug Diaphragm
n on it s re pl ac emenSteel
square root output conformity for differential
informatio pressure, Material Carbon 316 SS 316L SS A _ _ • • • 0.00
and engineering units display for PV, flow rates martLine SMV800 . SS
316 316 SS 316L SS E _ _ • • • 77.00
the S Hastelloy C Hastelloy C Hastelloy C J _ _ v v 1608.00
• Improves efficiency in commissioning, start-up, and on- Monel Monel Monel L _ _ v 821.00
going maintenance through local and remote interface Fill Fluid Silicone _ 1 _ • • • 0.00
with SmartLine Configuration Toolkit and host system CTFE _ 2 _ • • • 57.00
Process 1/4" NPT _ _ A • • • 0.00
Condensed Specifications Head 1/2" NPT with Adapter (1/4" NPT Head) _ _ H t t t 0.00
Temperature: -40° to 200° F; Meter Body : -40° to 257° F No Selection 00000 • • • 0.00
Pressure: 1” H2O Abs for 2 hrs @ 158° F min.; Overpressure: 3000 PSI None 00 • • • 0.00

Temperature Sensors
Analog Meter (0-100 Even, 0-10 Sq. Root.) ME • • • 170.00
Two-Wire Output: 4–20 mA or digital (DE protocol)

and Transmitters
Viton Head Gaskets (1/2" Gaskets Special) VT • • • 0.00
RFI Protection (Std.): Negligible effect (20–1000 MHz @ 30V/meter) Mounting Bracket — Carbon Steel MB • • • 20.00
Materials: Process Interface: 316L SS, Hastelloy C-276, Monel, Tantalum Mounting Bracket — Stainless Steel SB b • • • 75.00
diaphragms; 316 SS, Carbon Steel, Monel, Hastelloy process heads; Flat Mounting Bracket — Carbon Steel FB • • • 20.00
Teflon, Viton head gaskets; Carbon Steel, A286 SS (NACE) bolting; Mount- Lightning Protection LP • • • 68.00
ing Bracket: Carbon Steel; Electronics Housing: Low Copper Aluminum Stainless Steel Customer Wired-On Tag
Hazardous Conditions: Housing meets NEMA 4 (watertight) and NEMA (4 Lines, 28 Char/Line, User-Supplied Info.) TG • • • 24.00
7 (explosion-proof ); FM, CSA, ATEX approval available. Multivariable Transmitter Configuration MC • • • 85.00
Write Protection WP • • • 22.00
Differential Pressure Measurement Clean for Oxygen/Chlorine Service, Certificate 0X j j j 211.00
Upper Range Limit (URL): 400” H2O (1000 mbar) Approval Type Location/Class

Wireless Sensing and


Turndown Ratio: ±400:1 Explosion Proof Cl I, Div 1, Gr A-D

Communications
Dust Ignition Proof Cl II, III, Div 1, Gr E-G 1C • • • 0.00
Minimum Span: 20” H2O square root; 1” H2O linear
Suitable for Cl III, Div 1
Zero Elevation/Suppression: No limit (min. span) within ±100% URL. Non-Incendive Cl I, Div 2, Gr A-D
Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital FM Intrinsically Safe Cl I, II, III, Div 1, Gr A-G b
Mode: Lesser of ±0.075% calibrated span or ±0.15% reading. Explosion Proof Cl I, Div 1, Gr B-D
Dust Ignition Proof Cl II, III, Div 1, Gr E-G 1J • • • 0.00
Absolute Pressure Measurement Suitable for Cl III, Div 1
Upper Range Limit (URL): 750 PSIA; Minimum Span: 5 PSIA Non-Incendive Cl I, Div 2, Gr A-D
Intrinsically Safe Cl I, II, III, Div 1, Gr A-G
Turndown Ratio: 150:1
Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital Restrictions
96
Mode: Lesser of ±0.075% calibrated span or ±0.15% reading. b Select only one option from this group. See pagewell
e y
for Hon 00
Analytical Instruments

j Available only on units with CTFE fill ( _ 2 _ in Fill Fluid).


Temperature Measurement
t Available only with 1/2” NPT adapter flange (Options SCT30
smart n
and Systems

Range (Pt100Ω RTD): -328° to 1562° F operating; 1.08° F accuracy S2, T2, or V2).
tio
Adjustment Range: Limit to zero/span within range. v Includes side vent drain at no added cost. configurait.
Accuracy (Reference): Analog Mode: Digital accuracy + Output D/A ac- w Available only with 316SS process heads. Not available to o lk
curacy; Digital Mode: Digital accuracy; (Output D/A): ±0.025% of span with side vent/drain (SV).
Thermocouple Burnout: User-selectable detection: ON = up- or down-
scale failsafe action, critical status message for any open lead. Add a three-valve manifold to your transmitter!
See page 345. For 100Ω RTDs, see page 98.
View full specifications online at Lesman.com
FLOWMETER Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
64

V 01.2018
SYSTEMS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

Honeywell VersaFlow — Flowmeters for Any Application


Flow Measurement
Instruments

Electromagnetic Flowmeter Coriolis Mass Flowmeter


• Conductivity down to 1 uS/cm • Innovative twin measuring tube sensors with optimized flow
Pressure Transmitter

• Temperatures to 356° F (180° C) divider for minimal pressure loss


• Available sizes 0.1” to 80” (DN 2.5-3000) • For applications up to 266° F (130° C)
• Stainless steel flow tube spool with carbon steel or stainless • Measures from 0.3 to 430,000 kg/h flow
steel flanges • Pressure-resistant jacket to 1450 PSI (100 bar)
• Standard liner materials: PTFE, PFA, ETFE, hard rubber, and • Excellent zero stability
polyurethane • Available with hygienic process connections for food and
• Electrodes available in 316 stainless steel, Hastelloy C, plati- pharmaceutical applications
num, titanium, tantalum, carbon, PTFE, and Cermet • Rapid signal processing, even with product and temperature
• Signal converters available in wall mount, rack mount, com- changes or sudden changes in density
pact, and field-ready housings
Temperature Sensors

• Modular electronics concept and data redundancy – sensor


and Transmitters

• Signal converter offers local display, infrared interface, HART and plug-and-play electronics are easy to replace
communications, four isolated outputs • Viscous or shear-sensitive products
• Diagnostics to standards better than requested by NAMUR • Products requiring low flow velocities, products with en-
2650: 100% flow sensor and converter check, 100% process/ trained solids or gas, or products in homogeneous mixtures
application check, 100% linearity/calibration check
• Flow and purity measurement, density, temperature, and
• Accuracy to ±0.15% measured value concentration measurement
• Suitable for all conductive applications
VersaFlow coriolis measures mass flow, density, volume, temperature,
• Measures flow in any application, from clean liquids to slur- mass, or volume concentration and solids content with a single device.
ries and pastes with high solids content It’s the only Coriolis sensor for mass flow in its class with secondary
Wireless Sensing and

• Abrasion-, chemical-, and vacuum-resistant pressure containment standard. It offers a high degree of accuracy,
Communications

even for problematic applications. All meters consist of a sensor and a


VersaFlow magnetic flowmeter is suitable for a variety of measuring converter. The converter is mounted integral to the sensor or remotely
tasks and applications, including rapidly changing media, pH jumps, large via a field-mount kit, a wall-mount housing, or a 19” rack-mount module.
amounts of solids, or pulsating flow. It delivers significant cost savings
during planning, procurement, installation, and training. Condensed Specifications
VersaFlow is wired exactly like a traditional magmeter, but no earth Flow Rate: 0–240 to 0–15800 lbs/min, depending on sensor model
connection to the liquid is required. This reduces the high costs involved Accuracy: Liquid: ±0.15% actual measured flow rate; Gas: ±0.5% actual
with purchasing exotic metal grounding rings or electrodes. measured flow rate
A new virtual reference grounding eliminates the need for grounding Density Measuring Range: 25-155 Lbs/Ft3 (400-2500 Kg/m3)
electrodes or rings, reducing installation costs and potential leak points. Temperature Measuring Range: -40° to 302° F (-40° to 150° C); Accuracy:
Analytical Instruments

It provides complete isolation with opto-couplers of the flow converter’s ±1.8° F (1° C)
input amplifier and coil power circuits. The measurement circuit “floats” Materials: Sensors available in Stainless steel, Titanium, Hastelloy, or Tantalum,
and Systems

at liquid’s potential, sensing only the induced voltage caused by the aluminum or stainless steel housings
velocity of the conductive liquid flowing through the sensor.
Approvals: FM, CSA, ATEX, 3A (depending on model selected)
A calibrated flow simulator is available for magmeters to troubleshoot
converter and other system indicators and controls. It replaces the flow Visit www.Lesman.com for complete specifications.
sensor in the system and simulates no-flow and up to five flow rates to
troubleshoot flow output issues.
Visit www.Lesman.com for complete specifications. See our viscosity table for common substances, page 489.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan FLOWMETER
65

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
SYSTEMS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
VersaFlow Vortex for Monitoring
Steam Production and Transfer
Cost of a steam leak
There are two costs associated with the production of steam. The
first is the gas feed to the boiler. The other is in monitoring the ef-

Flow Measurement
ficiency of the lines transporting the steam.

Instruments
The major concern, once a line is designed, is the integrity of the
pipeline and how much steam is being lost to leakage.
By placing a vortex meter at the discharge of the boiler and tak-
ing advantage of the integral temperature measurement, you can
accurately measure the generated steam. If you have a flow meter
on the gas feed line, you can monitor boiler efficiency by comparing
gas use to pounds of steam produced.

Vortex Flowmeter Then, by placing another vortex meter at a designated spot further
downstream of the boiler, you can make the measurement again
• Works with conductive or non-conductive liquids, industrial and compare the flow rate of the steam to what’s coming off the

Pressure Transmitter
compressed gases boiler. Any reduction in flow not accounted for by any usage points
in between can be attributed to leakage.
• Sensors with 0.5” to 12” flanges or 0.5” to 4” sandwich sizes
As you can see in the table, even a small leak can cost thousands
• Two-wire device with integrated pressure and temperature of dollars per year, not including the additional cost it takes to manu-
compensation, plus compensation for saturated steam facture more steam to compensate for the loss. Left unchecked, a
• Non-wearing, fully welded stainless steel construction with 1/2” leak can cost upwards of $50,000 per year.
high corrosion, pressure, and temperature resistance Cost of steam leaks, given 100 PSI steam flow, at $5.00 per 1000 pounds.
• Optimal process reliability: Intelligent stable readings, free of Steam Loss per Total Cost per Annual
external signal processing Size of Leak Month (Lbs) Month Cost
• Maintenance-free sensor design 1/8” 52,500 $262.50 $3,150.00

Temperature Sensors
3/16” 117,000 $585.00 $7,020.00
• Current, pulse, and HART communications outputs

and Transmitters
1/4” 210,00 $1,050.00 $12,600.00
For superheated and saturated steam measurement, steam boiler 5/16” 325,000 $1,625.00 $19,500.00
monitoring, compressor output monitoring, measuring consumption in 3/8” 470,000 $2,350.00 $28,200.00
compressed air systems, measuring consumption of industrial gases, SIP 7/16” 637,000 $3,185.00 $38,220.00
and CIP processes in the food, beverage, and pharmaceutical industries
1/2” 835,000 $4,175.00 $50,100.00
VersaFlow 100 is the only vortex flowmeter with integrated pressure
and temperature compensation in two-wire technology, providing One pound of 100 PSI steam contains about 1,200 BTUs. 1 MCF of
maximum performance at the lowest installed cost. VersaFlow provides natural gas contains 1 million BTUs.
reliable measurement of operating, standard volumetric, and mass flow If the steam is produced at 85% efficiency, the input energy is 1411
of conductive and non-conductive liquids, gases, and vapors, even with BTUs per pound. (1200/0.85=1411) So, 1000 pounds of steam requires
fluctuating pressures and temperatures. 1.4 million BTUs to produce it. The cost to produce 1000 pounds of

Wireless Sensing and


steam from natural gas is 1.4 x cost/MCF. So, when natural gas costs

Communications
Condensed Specifications $7/MCF, the cost of 1000 pounds of steam is $9.80.
Measuring Principle: Karman vortex street Further, by using the vortex meter’s local display or the HART®
Measured Value: Primary: Number of separated vortices; Secondary: Operat- protocol, you can track temperature and see any extraordinary heat
ing and standard volumetric flow or mass flow loss from where you measured at the boiler. Heat loss means energy
Accuracy: Reynolds numbers (Re)≥20000: ±0.75% for liquids, Re≥20000: ±1% costs, so tracking this variable can be critical.
for gases or vapors; 10000<Re<20000: ±2% for liquids, gases, or vapors; Honeywell’s VersaFlow vortex meter is the only meter of its type
Repeatability: ±0.1%; Stability: ±0.1% over 1 year
that offers integral temperature compensation standard, and integral
Process Medium Viscosity: <10 cP pressure compensation as an option. These features improve accuracy
Outputs: Current: 4-20 mA; Pulse: Pulse frequency 0.5 Hz; Communications: and significantly reduce energy costs. VersaFlow can also be used for:
HART® protocol • Burner consumption measurement
Analytical Instruments

Approvals: FM: Class 1, Div 1; ATEX: II 2G EEx d ia [ia] IIC T6 • Controlling compressor capacity, consumption measurement in
and Systems

compressed air networks


Visit www.Lesman.com for complete specifications.
• SIP and CIP processes in the food, beverage, and pharmaceutical
industries
To select a Honeywell VersaFlow system for • Measuring industrial gases (natural gas, oxygen, nitrogen, hydro-
your application, complete the datasheet from gen, and argon)
www.Lesman.com/datasheets/ and send it to • Conductive and non-conductive liquids
Lesman for engineering review.
MAGNETIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
66

V 01.2018
FLOWMETERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS FM MAGFLO Electromagnetic Flowmeters


Flexible Transmitter Electronics
Need FM Class I, Div 1 meters?
Choose between Mag 5000 (±0.5% accuracy) and Mag 6000 (±0.25%
MAGFLO models are available for harsh
accuracy) for high performance, easy operation, and reduced mainte-
environments. Call Lesman for help.
nance. Mag 5000 is a robust solution for all-around applications. Mag
6000 is for the more demanding applications where higher accuracy
and greater functionality are required.
The Mag 6000i (Industry) transmitter is designed for the special de-
Flow Measurement

mands in the process industry. The robust, full-metal housing provides


superb protection, even in the harshest industrial environments. Full
Instruments

input and output functionality is provided, even in the ATEX EEx d version.
Individual calibration and fingerprint (mag-
netic property) data are pre-programmed
at the factory and stored in the MAGFLO’s
SensorPROM module. Setup data is added
during configuration. This unique combina-
tion ensures a cost-effective, easy, and error-
free installation.
MAGFLO flowmeters make it easier for you to manage flow. Whether Plug and play communication modules
Pressure Transmitter

it’s installation, managing operations, or verifying continuous accuracy, make your MAGFLO compatible with your plant network protocol.
our customers rely on Siemens MAGFLO to improve their processes. Changing communications standards or moving the MAGFLO to a dif-
ferent network? Just swap out the communications module. No need
Greater Flexibility and Expandability to buy a new magmeter.
• One transmitter/converter electronics box fits all sensor tubes
• Choice of integral mount, remote pipe or wall mount, explosion-proof, Sensor Tube Designs for Every Industry
or 19” rack mount electronics styles available Mag 5100W: A sensor for all water and wastewater
• Ready for your plant data network! Universal communications slot on applications. With its coned design, increased low-flow
each converter accuracy is achieved, making it especially useful for leak
• Communication modules for HART®, Modbus RTU, Profibus PA/DP. detection. It can be made suitable for direct burial and
Add-on modules allow upgrades without buying a new flowmeter constant flooding. Mag 5100W complies with drinking
water and custody transfer approvals.
Temperature Sensors

Easier to Operate Mag 1100: The flangeless wafer design that meets all
and Transmitters

• Mag 5100W doesn’t require grounding rings flange standards. The Mag 1100 is used in all industries
• Robust construction and materials: PTFE, PFA, Ceramic, and NOVALAK where the corrosion-resistant stainless steel housing and
liners; AISI 316 Ti stainless steel, Hastelloy C, Titanium, Tantalum, and highly resistant liner and electrodes fit even the most
Platinum electrodes extreme process media. Mag 1100s are available with FM
and ATEX approvals for installations in hazardous areas.
• Only Siemens offers NOVALAK, a revolutionary liner material with a
smooth, hard, non-porous finish that provides the highest level of Its obstruction-free performance minimizes the risk of
protection against corrosion, abrasion, high pressure and temperature, deposits. And, it’s unaffected by the suspended solids,
and vacuum conditions. It has the chemical resistance you expect viscosity, and temperatures typically found in pharma-
from PTFE with the mechanical strength and stability of steel. ceutical processes. The Mag 1100 is suitable for CIP and SIP cleaning,
• Uniform user interface for all MAGFLO products and withstands the high pressures of hose-down.
Wireless Sensing and

Mag 1100 Food: Specially designed for the food and


Communications

Easier to Commission beverage industry, Mag 1100F offers unique and flexible
• Pushbuttons on transmitter electronics make setup easy for techni- process connections. Mag 1100F was the first to pass
cians and contractors EHEDG hygienic test and meets all sanitary standards. Its
• SensorPROM holds identity of each flowmeter: Calibration data, performance is unaffected by suspended solids, viscosity,
magnetic properties, user setup, and programming. and temperature changes.
• SensorPROM module enables instant measurement at power-up The Mag 1100F features an AISI 316 stainless steel
enclosure with an IP67/NEMA 4X rating that is upgrad-
Easier to Service able to IP68/NEMA 6P. It’s delivered with your choice of flange adapter,
• Transmitter replacement requires no programming with metal-to-metal design, and no grounding connection required.
• SensorPROM automatically updates all settings after initialization
Analytical Instruments

Advanced Diagnostics of Application and Metering


• Identification in clear text and error log
and Systems

Siemens has
• Error categories: Function, warning, permanent, and fatal Tri‑Clover and
• Transmitter self-check including outputs and accuracy Tri‑Clamp adapters
• Sensor check function in stock, ready for
• Overflow quick assembly and
• Empty pipe, partial filling, low conductivity, electrode fouling shipment!
• System verification with MAGFLO Verificator
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan MAGNETIC
67

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
FLOWMETERS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
MAGFLO?
Why Do So Many Engineers Choose
g rings.
(1) Universal • Mag 5100W doesn’t need groundin
Signal Modules for fits all sens or tube s, so one universal spare cov-
Communication • One transmitter
ers all applications.
the keypad — contractors
• Easy transmitter configuration with
(2) SensorPROM
and technicians love them !
Memory Module cation service from Siemens,
1
• Owners can schedule on-site verifi
FLO Verificator unit.
or do their own verification with MAG a

Flow Measurement
2 serv er a quick swap-out.
• SensorPROM makes replacement
, it’s easy to get data

Instruments
on mod ules
• With the universal communicati
onto the plant netw ork.
rd of reliability, with calibration
• They can produce a traceable reco
data and verification test results.

Call for
Plug and Play communication modules and swappable SensorPROM Verificator
In-Situ Verification Service!
memory module make replacing electronics quick and painless!
Using the MAGFLO Verificator, Sie-

Pressure Transmitter
mens offers in-situ verification for docu-
Mag 3100: This flexible and comprehensive sensor menting continuous accuracy for critical
program offers a wide range of sizes, to fit a wide variety process applications — especially crucial
of general industry applications. Liners and measuring when your application is required to
electrodes capable of withstanding the most extreme meet ISO 9001, ISO 4001 or other quality
processes are available. All welded construction provides management programs.
a ruggedness that suits the toughest environments. Through in-depth analysis, Siemens
Mag 3100P: Designed to meet the most common specifications in the has identified the parameters that influ-
chemical and process industries. It features fully welded construction for ence the accuracy of a flowmeter operat-
ruggedness, and PTFE or PFA liners and Hastelloy electrodes for flexibility. ing in the real world. These parameters
Mag 8000W: These battery-powered units give you the flexibility to are checked using a patented verification
install a reliable water meter almost anywhere, without technique for MAGFLO flowmeters.

Temperature Sensors
sacrificing accuracy or performance. It’s optimized for In-situ verification requires no interruption of flow, no opening of pipes,

and Transmitters
leakage detection and accurate billing. and no disconnection of cabling. The Verificator can run a full installation
The Mag 8000W features a datalogger with selectable test of the transmitter, sensor, and cabling — all in less than 15 minutes!
log interval up to 26 months, an infrared (IrDA) port for Transmitter Test: The transmitter test is a flow simulation test that
on-site downloads, power management with selectable checks the whole electronic system from signal input to output. Using
battery alarm levels, a self-check feature with automated the magnetic field energy, the Verificator simulates a flow signal to the
data backup, and three totalizers, one with user reset. transmitter input. By measuring transmitter output, the Verificator cal-
culates its accuracy against factory-defined values.
Transmag 2: For Heavy-Duty Applications
Flowmeter Insulation Test: This“cross-talk”test of the entire flowmeter
Thanks to its pulsed AC system, the Transmag 2 is ensures that the sensor flow signal is unaf-
capable of measuring where conventional DC field fected by external influences. In this test,

Wireless Sensing and


technology fails, including applications with high con- the Verificator generates a high voltage

Communications
centrations of pulp stock, heavy slurries, or slurries with disturbance within the coil circuit, and
magnetic particles. then looks for any cross-talk induced in the
Magnetic particles in the media boost the magnetic field in the flow- flow signal circuit. By generating dynamic
meter and cause bad readings. Transmag 2 overcomes this issue with disturbances close to the flow signal, the
a second compensating coil circuit. The alternating field technology flowmeter is tested for noise immunity to a maximum level.
generates a much stronger magnetic field within the sensor, to measure Sensor Magnetism Test: This “boost” test of the magnetic field coil
more reliability and with greater precision — even when the media has ensures that the electromagnetic signal meets the original settings.
a high concentration of solids. In the boost test, the Verificator changes the magnetic field pattern
There’s a solution to every abrasive media application, and uses high voltage to get quick stable magnetic conditions. Then, it
and the choice of construction material is crucial to pro- compares the current sensor magnetism
tect the flowmeter. Besides inlet protection rings, Siemens to the factory “fingerprint” determined
Analytical Instruments

offers a broad range of liner and electrode materials — during initial calibration, and stored in
like the soft LINATEX rubber and NOVALAK liner, which SensorPROM.
and Systems

have proven themselves in these harsh environments. An authorized, signed certificate docu-
ments the verification, and includes test
Need help finding the right magmeter? results with pass/fail approval, installa-
Download the application datasheet from tion specifications, flowmeter specifica-
www.Lesman.com/datasheets/ and send it to Lesman for tion and configuration, and Verificator
engineering review. specification with calibration date (to ensure traceability to national and
international standards.)
MAGNETIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
68

V 01.2018
FLOWMETERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS FM MAGFLO Electromagnetic Flowmeters


Call for
Verificator
service
Flow Measurement
Instruments

Integral Mount Rack/Panel Mount Remote Mount MAGFLO Verificator SensorPROM Communication Wall mount Junction
Mag 5000/Mag 6000 Mag 5000/Mag 6000 Mag 6000i (Ex d) Memory Module Modules Box for Mag 5000/6000

MAGFLO Transmitter Electronics MAGFLO Mag 5000 MAGFLO Mag 6000


• ULc Approved FM Class 1, Div 2 • ±0.5% Accuracy with All Sensors • ±0.25% Accuracy with Selected Sensors
• Rated NEMA 4X and NEMA 6 • 1 Current, 1 Digital, 1 Relay Output Standard • Advanced Batch Control Functions
• Choice of 115–230 VAC or 12–24 VAC/VDC Power • Available with HART® Communication • Add-On Plug-In Communication Modules
• 3-Line, 20-Character Backlit Display • Only Available for Sensors 1/2” to 48” • Required for Use with Sensors Larger than 56”
• Can be Ordered Blind (No Local Digital Display) • Optional Design: Mag 6000i Industrial Enclosure
Pressure Transmitter

Step 1: Choose your electronics by accuracy, power, and mounting style. Step 2: Choose your flow sensor by size and liner material.
Add connecting cables and any accessories you need. Issue your order to Siemens Industry Inc, c/o Lesman Instrument Company.

Model Selection Guide


Description Catalog Number Price Description Catalog Number Price
Mag 5000 Transmitters; Max. Measuring Error: 0.5% of Flow Rate Interconnect Cables (Price per foot, two lengths required per installation)
Integral Mount, 115-230 VAC 7ME6910-1AA10-1AA0 $1345.00 Standard Interconnect Cable FDK:001STCAB ** $3.00
Integral Mount, 11-30 VDC 11-24 VAC 7ME6910-1AA30-1AA0 1345.00 Special Interconnect Cable (for Empty Pipe) FDK:001SPCAB ** 4.00
Integral Mount, No Display, 115-230 VAC 7ME6910-1AA10-0AA0 1117.00 ** Choose two standard or one standard and one special cables.
Integral Mount, HART®, 115-230 VAC 7ME6910-1AA10-1BA0 1555.00 Both are PVC jacket, three-conductor plus overall braided shield.
Temperature Sensors

Rack Mount, 115-230 VAC 7ME6910-2CA10-1AA0 1525.00


and Transmitters

Plug-In Communications Modules for Mag 6000 Electronics


Mag 6000 Transmitters: Max. Measuring Error: 0.25% of Flow Rate
Mag6000 HART Communication Module FDK:085U0226 222.00
Integral Mount, 115-230 VAC 7ME6920-1AA10-1AA0 1584.00 Mag 6000i HART Communication Module FDK:085U0321 227.00
Integral Mount, 11-30 VDC 11-24 VAC 7ME6920-1AA30-1AA0 1584.00 Mag 6000 Modbus RTU/RS485 Module FDK:085U0234 222.00
Rack Mount, IP20/NEMA 2, 115-230 VAC 7ME6920-2CA10-1AA0 1812.00
IP66/NEMA 4 ABS Plastic Enclosure, Spare Parts and Accessories
115-230 VAC 7ME6920-2EA10-1AA0 1834.00 Mag 5000/Mag 6000 Sensorprom 2KB FDK:085U1005 69.00
Mag 6000i Transmitter: Max. Measuring Error: 0.25% of Flow Rate Mag 5000/Mag 6000 Display Unit FDK:085U1039 170.00
Remote Mount IP67/NEMA 4X Sun Shield for Remote-Mt Polyamide Covers A5E01209496 229.00
Aluminum Enclosure 10-220 VDC/AC 7ME6930-2BA20-1AA2 2095.00 Sun Shield for Integral Polyamide Covers A5E01209550 368.00
Mounting Kits and Hardware MAGFLO Verificator
Wall Mount Junction Box IP67/NEMA 4X/6 FDK:085U1053 235.00 MAGFLO Verificator (With Software and
Wireless Sensing and

Submersible Kit for Terminal Box, for IP68, Adapter for IP67/Rack-Mount Models) FDK:083F5061 18560.00
Communications

10m w.g. Rating FDK:085U0220 144.00


21TE Panel Mount Kit for 19” Insert
IP65/NEMA4 Enclosure in ABS Plastic FDK:083F5030 398.00
21TE Back Panel Mount Kit for 19” Insert Great for Drinking Water Applications Battery
IP20/NEMA 2 Enclosure in Aluminum FDK:083F5032 182.00 Powered!
Polyamide Terminal Box with Lid for Flow Sensor Body Mag 8000W (Drinking Water) 0.5%
Field-Mount MAGFLO Sensors FDK:085U1052 222.00 Accuracy, Battery-Powered Magmeter with Standard Mag5100W Sensor,
Connection Plate for 19” Rack Mount FDK:083F4117 84.00 Integral Transmitter, and Integral Battery Pack (2 D-
Brass Adapters, PG13.5 Male to 1/2” NPTF FDK:A6X30005543 19.00 Cells). Qmax=Volume Unit
2” 277 GPM 7ME6810-2YJ31-2AA1 $3016.00
2.5” 440 GPM 7ME6810-3FJ31-2AA1 3027.00
er?
the right magmet
3” 704 GPM 7ME6810-3MJ31-2AA1 3039.00
fi nd in g
Analytical Instruments

Nee d he lp
sheet
4” 1100 GPM 7ME6810-3TJ31-2AA1 3091.00

ou t th e S ie m en s application data back to 5” 1761 GPM 7ME6810-4BJ31-2AA1 3303.00


Fill d fax it
and Systems

/datasheets/ an
6” 2769 GPM 7ME6810-4HJ31-2AA1 3497.00
from Lesman.com r engineering review. 8” 4389 GPM 7ME6810-4PJ31-2AA1 3827.00
Lesman fo

10” 7044 GPM
12” 11007 GPM
7ME6810-4VJ31-2AA1 4321.00
7ME6810-5DJ31-2AA1 5519.00
Now available with wireless interface. Call for details.

Visit www.Lesman.com for more information on Siemens’ line of SITRANS FM MagFlo magnetic flowmeters.
Get specs, manuals, and quick start guides.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan MAGNETIC
69

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
FLOWMETERS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Popular models in 1” to 12” sizes usually available
to ship within two weeks!

Sensors for General Industrial Applications Flow Sensor Body Mag3100P: PTFE Liner, Hastelloy C-276 Electrodes, ANSI
Flow Sensor Body Mag3100: Neoprene Liner, 316SS Electrodes, ANSI Class Class 150 Carbon Steel Flanges, Carbon Steel Housing
150 Carbon Steel Flanges, Carbon Steel Housing 0.5” 7ME6340-1VJ13-2AA2 $1871.00

Flow Measurement
1” 7ME6310-2DJ11-1AA2 $1454.00 1” 7ME6340-2DJ13-2AA2 1702.00
1.5” 7ME6310-2RJ11-1AA2 1473.00 1.5” 7ME6340-2RJ13-2AA2 1733.00

Instruments
2” 7ME6310-2YJ11-1AA2 1520.00 2” 7ME6340-2YJ13-2AA2 1757.00
2.5” 7ME6310-3FJ11-1AA2 1544.00 2.5” 7ME6340-3FJ13-2AA2 1781.00
3” 7ME6310-3MJ11-1AA2 1564.00 3” 7ME6340-3MJ13-2AA2 1809.00
4” 7ME6310-3TJ11-1AA2 1632.00 4” 7ME6340-3TJ13-2AA2 1899.00
6” 7ME6310-4HJ11-1AA2 2219.00 6” 7ME6340-4HJ13-2AA2 2598.00
8” 7ME6310-4PJ11-1AA2 2769.00 8” 7ME6340-4PJ13-2AA2 3826.00
10” 7ME6310-4VJ11-1AA2 3423.00 10” 7ME6340-4VJ13-2AA2 5209.00
12” 7ME6310-5DJ11-1AA2 4824.00 12” 7ME6340-5DJ13-2AA2 7352.00

Pressure Transmitter
Sensors for Food, Beverage, and Pharmaceutical Use For Water and Wastewater Applications
Flow Sensor Body Mag1100: PFA Liner, Hastelloy-C Electrodes, Includes Flow Sensor Body Mag 5100W: Nitrile Rubber Liner, Hastelloy C Electrodes,
EPDM Gaskets, SS Studs and Nuts ANSI Class 150 Carbon Steel Flanges
3/8” DN10 7ME6110-1RA10-1AA2 $1514.00 1” 7ME6580-2DJ14-2AA2 $1092.00
1/2” DN15 7ME6110-1VA10-1AA2 1514.00 1.5” 7ME6580-2RJ14-2AA2 1105.00
1” DN25 7ME6110-2DA10-1AA2 1514.00 2” 7ME6580-2YJ14-2AA2 1142.00
1.5” DN40 7ME6110-2RA10-1AA2 1793.00 2.5” 7ME6580-3FJ14-2AA2 1154.00
2” DN50 7ME6110-2YA10-1AA2 2073.00 3” 7ME6580-3MJ14-2AA2 1167.00
2.5” DN65 7ME6110-3FA10-1AA2 2200.00 4” 7ME6580-3TJ14-2AA2 1217.00
3” DN80 7ME6110-3MA10-1AA2 2334.00 5” 7ME6580-4BJ14-2AA2 1429.00
4” DN100 7ME6110-3TA10-1AA2 2868.00 6” 7ME6580-4HJ14-2AA2 1623.00
8” 7ME6580-4PJ14-2AA2 1953.00
Flow Sensor Body Mag1100: Ceramic Liner, Plati-
10” 7ME6580-4VJ14-2AA2 2447.00

Temperature Sensors
num Electrodes, EPDM Gaskets, SS Studs and Nuts
12” 7ME6580-5DJ14-2AA2 3645.00

and Transmitters
0.078” DN2 7ME6110-1DA20-2AA2 $1577.00 14” 7ME6580-5KJ14-2AA2 5052.00
1/8” DN3 7ME6110-1HA20-2AA2 1577.00 16” 7ME6580-5RJ14-2AA2 5653.00
1/4” DN6 7ME6110-1MA20-2AA2 1378.00 18” 7ME6580-5YJ14-2AA2 6283.00
3/8” DN10 7ME6110-1RA20-2AA2 1378.00 20” 7ME6580-6FJ14-2AA2 6977.00
1/2” DN15 7ME6110-1VA20-2AA2 1378.00 24” 7ME6580-6PJ14-2AA2 7755.00
1” DN25 7ME6110-2DA20-2AA2 1378.00
1.5” DN40 7ME6110-2RA20-2AA2 1652.00
2” DN50 7ME6110-2YA20-2AA2 1928.00
2.5” DN65 7ME6110-3FA20-2AA2 2063.00
3” DN80 7ME6110-3MA20-2AA2 2202.00 Ideal for Applications with High
4” DN100 7ME6110-3TA20-2AA2 2788.00 Concentration of Suspended Solids
Flow Sensor Body Mag1100 Food: PFA Liner, Hastelloy-C Electrodes. (Pulp and Paper, Cement, Mining)

Wireless Sensing and


Select Tri-Clover® or Tri-Clamp® Sanitary Adapter Below TransMag2 Electronics: Patented Pulsed AC Mag-

Communications
3/8” DN10 7ME6140-1RA10-1AA2 $1514.00 netic Flowmeter for High Suspended Solids. IP67/
1/2” DN15 7ME6140-1VA10-1AA2 1514.00 NEMA 4X Enclosure, Max. Measuring Error 0,50%
1” DN25 7ME6140-2DA10-1AA2 1514.00 Rate, 100–230 VAC Power; 1 Current, 1 Digital, 1
1.5” DN40 7ME6140-2RA10-1AA2 1793.00 Relay (or 1 DI) Outputs
2” DN50 7ME6140-2YA10-1AA2 2073.00 4-20 mA with HART Protocol 7ME5034-0AA11-2AA0 $2348.00
2.5” DN65 7ME6140-3FA10-1AA2 2200.00 Profibus PA Protocol 7ME5034-1AA11-1AA0 2925.00
3” DN80 7ME6140-3MA10-1AA2 2329.00
Mounting Bracket (Add Suffix to Model Number) -A02 99.00
4” DN100 7ME6140-3TA10-1AA2 2759.00
Flow Sensor Body 911/E for TransMag 2: PTFE Liner, Hastelloy C4 Electrode,
Tri-Clover® Sanitary Weld-In Adapter: Includes 2
Remote Design, 1/2” NPT Screwed Gland, IP67/NEMA 5 Protection, ANSI Flanges
Clamp Fittings, 2 Clamps, and 2 EPDM Gaskets
1” 7ME5610-2DJ13-2AA2 $2785.00
3/8” (1/2” Tri-Clover) FDK:083G2276 $245.00
1.5” 7ME5610-2RJ13-2AA2 2903.00
Analytical Instruments

1/2” (3/4” Tri-Clover) FDK:083G2277 245.00


2” 7ME5610-2YJ13-2AA2 3130.00
1” FDK:083G2279 295.00
2.5” 7ME5610-3FJ13-2AA2 3514.00
and Systems

1.5” FDK:083G2281 343.00


3” 7ME5610-3MJ13-2AA2 3636.00
2” FDK:083G2282 369.00
4” 7ME5610-3TJ13-2AA2 3926.00
2.5” FDK:083G2283 412.00
5” 7ME5610-4BJ13-2AA2 4100.00
3” FDK:083G2284 499.00
6” 7ME5610-4HJ13-2AA2 4355.00
4” FDK:083G2285 583.00
8” 7ME5610-4PJ13-2AA2 5673.00
10” 7ME5610-4VJ13-2AA2 6784.00
12” 7ME5610-5DJ13-2AA2 9108.00
14” 7ME5610-5KJ13-2AA2 9196.00
16” 7ME5610-5RJ13-2AA2 11011.00
CORIOLIS Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
70

V 01.2018
FLOWMETERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS FC Coriolis Mass Flowmeters


Mass 2100 Coriolis Mass Flow Sensor FC300 Coriolis Mass Flow Sensor
• Accuracy >0.1% mass flow rate • Accuracy >0.1% mass flow rate
• Dynamic turndown ratio >500:1, from • Dynamic turndown ratio >500:1
65 kg/h to a few g/h • One tube with no internal welds,
• Densitometer performance available reductions, or flow splitters
(Accuracy >0.001 g/cm3, repeatability • Balanced pipe design ensures
Flow Measurement

>0.0002 g/cm3) optimal stability under harsh and


Instruments

• Single continuous tube design, with unstable process conditions


no internal welds, reductions or flow • Four-wire Pt1000 temperature mea-
splitters offers optimal hygiene, safety surement for accurate mass flow,
• Market’s biggest wall thickness density and fractional flow
ensures optimal corrosion resistance • Intrinsically safe Ex ia IIC standard
and high-pressure durability
• Intrinsically safe Ex ia standard SITRANS FC300 sensor offers superior performance in flow and den-
sity accuracy, and turndown ratio. The compact enclosure fits in tight
MASS 2100 coriolis mass flow sensor is designed for low flow mea- installation spaces for measuring liquids and gases. It can be installed in
Pressure Transmitter

surement in liquids and gases. One unit measurs mass flow, volume horizontal or vertical position. FC300 can be connected to MASS 6000
flow, density, temperature and fraction. MASS 2100 can be connected transmitters for remote installation only.
to MASS 6000 transmitters for remote installation only.
Specifications
Specifications Sensor Size: DN 4 (1/6”)
Pipe: Inside Diameter: 1.5 mm (0.06”); Wall Thickness: 0.25 mm (0.010”) Mass Flow: Range: 0–772 lb/h; Accuracy: 0.1 % of rate; Repeatability: 0.05 of
Measuring Range: Mass Flow: 0–143 lb/h; Density: 0–0.10 lb/in3; Fraction: rate; Max. Zero Point Error: 0.022 lb/h
0–100° Brix; Temperature: -58° to 257° F (Optional 356° F); Density: Range : 0–0.105 lb/in3; Density Error: 0.00025 lb/in3; Repeatability
Liquid Pressure Measuring Pipe: Stainless steel: 3336 psi at 68° F; Hastelloy Temperature: -40° to 239° F (Optional to 356° F); Temperature Error: 0.9° F
C22/2.4602: 5294 psi at 68° F Brix: 0–100°; Error: 0.3° Brix
Construction: Measuring pipe/connection: 316L stainless steel; Hastelloy Pipe: Inside diameter: 0.14“; Wall thickness: 0.0098“; Liquid pressure measuring
Temperature Sensors

C22/2.4602; Enclosure: IP65 316L stainless steel pipe: 1885 psi at 68° F
and Transmitters

Connection: 1/4” NPTM ANSI/ASME B1.20.1 Construction: 316L stainless steel; Measuring pipe/connection: Hastelloy
Approval: Ex ia IIC T3-T6, DEMKO 03 ATEX 135252X C22/2.4602; Enclosure: IP67/NEMA4 316L stainless steel
Connection: 1/4” NPTM, ANSI/ASME B1.20.1
Approval: UL Class 1 Div. 1, Groups A–D, ATEX
t mass
Mass 6000 Mass Flow Transmitter Learn more abou
sman.com.
Specifications flowmeters at Le
• For mass flow rate, volume flow rate,
density, temperature, fraction flow Current Output: 0/4–20 mA;
(e.g., Brix) Load: < 800 Ω; Time constant: 0–99.9s adjustable
Wireless Sensing and

• One current output, one frequency/ Digital Output: Frequency: 0–10 kHz, 50 % duty cycle; Time constant: 0–99.9s
Communications

pulse output, one relay output, one adjustable; Active: 24 VDC, 30 mA; Passive: 3–30 VDC, max. 110 mA
digital input; All outputs can be Change-Over Relay: Load: 42 V/2 A peak; Functions: Error level, error number,
individually configured with mass, limit, flow direction
volume, or density Digital Input: 11–30 VDC; Start/hold/continue batch, zero point adjust, reset
totalizer 1/2, force output, freeze output
• Adjustable flow direction, with single
Cut-Off: Low-flow 0–9.9% max flow; adjustable density or empty pipe cutoff
and bidirectional flow measurement
Limit Function: Mass flow, volume flow, fraction, density, sensor temperature
• Limit switches with one or two limits,
Totalizer: Two eight-digit counters for forward, net or reverse flow
programmable for flow, density or
temperature Display: Backlit alphanumerical text, 3 x 20 characters for flow rate, totalized
Analytical Instruments

values, settings and faults. Reverse flow indicated by negative sign


• Full batch controller Zero Point Adjustment: Via keypad or remote via digital input
and Systems

• Two built-in totalizers count positive, negative or net Communication: Add-on modules: HART®, PROFIBUS PA and DP, MODBUS
• Noise filter for performance in tough environments RTU RS-485, DeviceNet, FOUNDATION Fieldbus H1
• Auto zero adjustment with zero point evaluation feedback Enclosure: Rating IP67/NEMA 6 Fiberglass reinforced polyamide;
Supply Voltage: 24 VDC/AC, 50–60 Hz
• Full service menu for effective use and troubleshooting
NAMUR: Within the value limits according to "General requirements“ with
• Compatible with MASS 2100, FC300 and other flow sensors error criteria A in accordance with NE 21
Cable Glands: Two 1/2” NPT or M20 polyamide cable glands
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CORIOLIS
71

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
FLOWMETERS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Need help choosing a coriolis mass flowmeter? Not sure coriolis is right for your application? Fill out
the application datasheet from www.Lesman.com/datasheets and fax it back to Lesman.

SITRANS FC430 Coriolis Mass Flowmeter


• Compact design: Install anywhere, • Can be validated and configured for SIL2 or SIL3 operation
fit multiple units into tight spaces; • Meets all IEC Ex, ATEX, and FM hazardous area requirements
Sizes available from 1.2” to 3”
• Standard Siemens local user interface (LUI): Reduces train-
• Flange, pipe thread, hygienic ing needs for added cost and time-efficiency. Full graphical

Flow Measurement
thread and hygienic clamp con- display, straight-forward commissioning, simple navigation,
nections available

Instruments
customized top-level views, standard programming wizards
• HemiShape flow manifold provide guidance for the inexperienced user
for low pressure loss; Avoids • Superior isolation and resistance against
cavitation and separation of external vibrations for 0.1% accuracy,
fragile fluids; Ideal for hygien- 0.05% repeatability, and no twisting
ic use (EHEDG/3A approved)
• MicroSD card stores user and factory set-
• 4-20 mA analog output with HART® tings, calibration data and certificates. For
7.2 standard. Other I/O can be configured for analog, pulse, audit trails and quick transfer of informa-
frequency, relay, or status tion to PC or between transmitters

Pressure Transmitter
• FCT030 transmitter available in remote and compact ver- • Remote FCS400 model’s digital sen-
sions, mountable on all FCS400 sensor sizes DN15 to DN80 sor link guarantees high-speed data
• Fully rotatable (0-180°) pedestal makes access possible from transfer, even with up to 200 meters
all sides, includes simple one-bolt release clamp between sensor and transmitter

Streamlined, compact SITRANS FCS400 sensor One SITRANS FC coriolis mass flowmeter can measure:
The SITRANS FCS400 coriolis mass flow sensor was designed for superior Mass Flow Rate Temperature Total Volume
performance and reliability: a very stable zero point, low pressure loss, Total Mass Brix Fraction Flow
and high immunity to process noise and plant vibrations. Density Volumetric Flow Rate % or Total Fraction
FCS400 is the most compact sensor available in today’s mass flowme-

Temperature Sensors
Innovative and user-friendly SITRANS FCT030 transmitter

and Transmitters
ter market. The small size makes installation and replacement easy, and
possible to fit multiple units into tight spaces. Based on patented digital signal processing technology, the SITRANS
The Siemens CompactCurve tube shape offers a 0.1% flow rate accuracy FCT030 transmitter delivers true multi-parameter measurements with
and high sensitivity for optimal measurement, even with very low flows. enhanced efficiency, security and simplicity. Fully modular for installation
The unit is self-draining and highly resistant to pressure burst. The ultra- and replacement; can be remote or compact mounted with all SITRANS
short tube provides better than 1 kg/m3 density accuracy. FCS400 sensor sizes.
HemiShape flow manifold design ensures balanced flow between Fully graphical interface display can be customized to show you dif-
tubes and makes the FC430 great for use in fragile liquids. It includes ferent information during measurement and diagnostics. Measurement
purge connectors for monitoring, safety relief valves, and rupture discs. views include multivariable numeric display, bar graphs, and trend curves.
The unique design secures low pressure loss and avoids cavitation at the On-screen diagnostics include timestamp and NAMUR results.
separation of fragile liquids — ideal in hygienic applications. Its smooth Four navigational buttons, help text, and wizards for processes make

Wireless Sensing and


surface allows for easy cleaning with minimal flow abstraction.

Communications
servicing the transmitter easy. The common Siemens menu structure,
Models can be ordered for standard, hygienic, or NAMUR service, and display layout, and input methods reduces the need for user training.
can be validated and configured for SIL2 or SIL3 operation standard. (SIL3 The SensorFlash MicroSD card serves as a removable database of
requires two flowmeters in series, monitored by a SIL-rated control system). operational user information and provides direct access to all relevant
certificates and audit trails.
SITRANS FCS400 Sensor Specifications
Sizes: DN15 (1/2”) DN25 (1”) DN50 (2”) DN80 (3”) SITRANS FCT030 Transmitter Specifications
Flow Range (Lb/h): 8,157 25,353 114,640 300,000 Input/Output Channels: Up to 4 channels combining analog, relay or digital
Accuracy: ±0.10%; Repeatability: ±0.05% outputs and binary input
Pressure rating: Measuring tube: 1450 PSI; Sensor enclosure: 20 bar for 1/2” Signal Processing: 100 Hz
and 1” models, 17 bar for 2” and 3” models Communication: HART 7.2
Analytical Instruments

Temperature: Process: -58° to 392° F; Ambient: -40° to 140° F Power supply: 24-90 VDC, 100-240 VAC
and Systems

Material: Wetted parts: 316L SS; Enclosure: IP67-rated 304 SS EMC performance: EN 61326-3-2
Process connections: Flanges: EN1092-1 B1 and D, ANSI/ASME B16.5, JIS; Pipe Local User Interface (LUI): Full graphical display, 240 x 160 pixels
threads: ASME (NPT), BSPP, VCO Quick-Connect; Hygienic threads: DIN11851, Construction: IP67-rated aluminum with corrosion-resistant coating
DIN11864-1, ISO2853, SMS1145; Hygienic clamps: DIN11864-2, DIN32676,
ISO2853, SMS1145 Mechanical load: 18 to 1000 Hz random, 3.17 G rms, in all directions
Approvals: Hazardous area: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Pressure Approvals: Hazardous areas: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Hygienic:
equipment: PED, CRN; Hygienic: 3A, EHEDG; Custody transfer: SITRANS FC430 3A; NAMUR; Custody transfter: SITRANS FC430 OIML R 117; Operational safety:
OIML R 117; Operational safety: SIL2 SIL3 (transmitter and redundant system)
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
72

V 01.2018
FLOWMETERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS F US Clamp-On Ultrasonic Flowmeters


Comparing SITRANS F US Clamp-On Flowmeter Configurations
Model
Flow Measurement
Instruments

SITRANS FTS020 SITRANS FUS1010 SITRANS FUP1010 FUE1010 FUH1010 FUG1010


Basic Standard Portable Energy Industry Hydrocarbon Industry Gas Industry
Applications Applications Applications

Replaces... Controlotron Controlotron Controlotron Controlotron Controlotron Controlotron


1020 1010N, 1010X, 1010P, 1010EN, 1010DV, 1010V, 1010B 1010GC
1010WX 1010WP 1010EP

Flow Range ±40 ft/sec (±12 m/s) bidirectional

0.001 ft/sec
Pressure Transmitter

Flow
(0.0003 m/sec) flow 0.001 ft/sec (0.0003 m/sec) flow 0.001 ft/sec (0.003 m/sec) flow rate independent
Sensitivity
rate independent

1” to 60”
Pipe Sizes 0.25” to 360” (DN 6.4 to DN 9140)
(DN 25 to DN 152)

Two 4–20 mA DC, Two


Optional
Four 4–20 mA user
Two 4–20 mA DC, Two 0–10 VDC, Two 4-Wire 1kΩ 0–10 VDC, Two 4-Wire Two 4–20 mA, Two
None selectable, Two 4-Wire
Inputs RTD 1000Ω RTD, Totalizer 4-Wire 1000Ω RTD
1000Ω RTD
commands (clear/hold)

Two 4–20 mA DC (1kΩ


4–20 mA DC
at 30 VDC), Two 0–10 Two 4–20 mA DC pro-
1x for single channel
Two 4–20 mA DC (1kΩ at 30 VDC), Two 0–10 VDC (5kΩ min.), VDC (5kΩ min.), Four grammable standard,
Outputs 1x 0–5 kHz pulse rate,
Temperature Sensors

Four SPDT relays for status alarms, Two 0–5 kHz frequency, RS232 0–5 kHz pulse rate Two 0–10 VDC, Four
digital isolated
and Transmitters

(None for NEMA 7/IP65 0–5 kHz, RS232


RS232
version), RS232

±0.5–1.0% flow for ±0.5–2.0% flow for ±0.5–1.0% flow for


Out of box 1-2%, cali-
1–2% actual volume velocities >1 ft/sec (0.3 velocities >1 ft/sec (0.3 velocities >1 ft/sec (0.3 0.5–1.0% flow, calibrat- bratable to 0.5%
reading m/sec) m/sec) m/sec) able to 0.15–0.3%
Accuracy of flow, 0.05 of API ±0.005–0.01 ft/sec
(Higher accuracy is ±0.005–0.01 ft/sec ±0.005–0.01 ft/sec ±0.005–0.01 ft/sec
number (interface (±0.0015–0.003 m/sec)
dependent on pipe (±0.0015–0.003 m/sec) (±0.0015–0.003 m/sec) (±0.0015–0.003 m/sec)
detector) for velocities <1 ft/sec
condition) for velocities <1 ft/sec for velocities <1 ft/sec for velocities <1 ft/sec
(0.3 m/sec)
(0.3 m/sec) (0.3 m/sec) (0.3 m/sec)

±0.15–1.0% flow ±0.15% flow for veloci-


0.05% (depending on
0.05–0.1% actual vol- ties >1 ft/sec (0.3 m/
model)
Batch ±0.15% flow for velocities >1 ft/sec (0.3 m/sec) sec)
Wireless Sensing and

ume reading for 5-100


Repeatability ±0.10–0.2% flow for
Communications

ft/sec (1.5–30 m/sec) ±0.0015 ft/sec (0.0005 m/sec) for velocities <1 ft/sec (0.3 m/sec) ±0.0015 ft/sec (0.0005
velocities >1 ft/sec (0.3
velocities, pipe condi- m/sec) for velocities <1
m/sec)
tion dependent ft/sec (0.3 m/sec)

Data Refresh 5 Hz 5 Hz (80 Hz output optional)

Enclosure NEMA 4X/IP65, NEMA NEMA 4X/IP65,


NEMA 4/IP65 IP67 NEMA 4X/IP65, NEMA 7/IP65, NEMA 7/IP66
Ratings 7/IP65, NEMA 7/IP66 NEMA 1/IP40

-40° to 140° F
Liquid (-40° to 60° C)
-40° to 250° (-40° to 120° C) standard; -40° to 450° F (-40° to 230° C) optional
Temperatures
Call for higher temps.
Analytical Instruments

90–240 VAC, 50/60 Hz,


30 VA, 9–36 VDC, 12W
90–240 VAC, 50/60 Hz
and Systems

100–240 VAC, 50/60 Hz, 100–240 VAC, 50/60 Hz, 90–240 VAC, 50/60 Hz, 30 VA, 9–36 VDC, 12W
Power Supply 30 VA or 9–36 VDC,
30 VA, 9–36 VDC, 12W 9–36 VDC, 10W 90–240 VAC, 50/60 Hz, 15 VA or 9–36 VDC, 10W
12W
Internal NiCad battery
(4 hour)

FM, CSA, ATEX, CCOE, FM, CSA, CE (fixed)


Approvals UL, ULc, CE UL, ULc, CE FM, CSA, ATEX, INMETRO, GoST
INMETRO, GoST UL, ULc, CE (portable)

Prices Start at $3509.00 $3857.00 $5136.00 $4697.00 $7595.00 $9141.00


Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
73

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
FLOWMETERS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Engineering specifications and more available online.
Learn more about Siemens SITRANS F US
Clamp-On Ultrasonic Flowmeters by visiting
www.Lesman.com/get/SICF.php

Since the accuracy of a clamp-on ultrasonic flowmeter depends on

Flow Measurement
choosing the right transducer, this is a crucial step in the meter configura-
tion. Siemens offers four types of transducers: universal, universal high

Instruments
temperature, high precision and Doppler. Before deciding on the most
appropriate transducer, consider these factors: pipe thickness, diameter
and material, liquid/gas type, and amount of aeration.
By evaluating all of these aspects before choosing your final configura-
tion, you are sure that your meter will work exactly the way you want it,
Flowmeter right from day one. With flexible configuration options combined with
configuration... permanent and portable versions, finding exactly what you need has
become a lot easier.
there’s an App
for that! Customize your flowmeter by choosing necessary transducers, num-

Pressure Transmitter
ber of channels and enclosures, or select a complete pre-configured
Don’t guess how much money’s system available for HVAC, power, and hydrocarbon
flowing through your pipe. industries.
Clamp-on and know!
As a crucial accessory, the clamp-on program also
• Measure practically any liquid and gas includes an easy-to-use, stand-alone digital ultrasonic
• Performance unaffected by viscosity, flow rate, pipe size, pipe wall thickness gauge. Since even the smallest
solids and aeration content pipe thickness miscalculations can have an impact on
accuracy, this high precision gauge is an indispens-
• High accuracy and repeatability through automatic tempera- able flow measurement tool.
ture compensation and zero drift correction
• Install on pipe sizes up to DN9140 (360”) SITRANS FUS1010: Versatility and Flexibility
Ultrasonic flowmeters can be used

Temperature Sensors
With no moving parts to wear or foul, no need to cut the pipe for within a wide variety of applications

and Transmitters
installation, and high accuracy WideBeam ultrasonic flow measurement and industries, so they’re quickly be-
technology, you have nothing to lose. coming the metering technology of
Siemens’ clamp-on ultrasonic flow technology offers several ad- choice. The versatile SITRANS FUS1010
vantages over other flow measurement methods. Transducers mount illustrates this perfectly.
quickly and easily on the outside of the pipe, so they’re ideal for retrofit It offers numerous advantages in
applications or anywhere corrosive, toxic or high pressure liquids and application adaptability that cannot
gases rule out the option of cutting the pipe. be matched by any other single flow
measurement technology: zero pressure drop, insensitivity to outside
The Transducer is Key noise, high turn-down ratio, interface software, and WideBeam and
Transducers for Siemens ultrasonic Doppler modes.
clamp-on flowmeters are available with

Wireless Sensing and


The SITRANS FUS1010 is available in single, dual

Communications
Doppler and WideBeam transit time mea- channel/beam, and four channel configurations
surement technologies, so there’s a solution plus your choice of three enclosures: NEMA 4X/IP65
to work in practically any installation. wall mount, NEMA 7/IP65 compact, and NEMA 7/
Doppler operation is suggested for IP66 wall mount.
liquids with extensive suspended solids or To accommodate more basic applications, the
aeration, and offers up to 2% flow accuracy. low cost SITRANS FTS020 comes with WideBeam
WideBeam transit time operation is the pre- and as single and dual channel versions, allowing
ferred mode for relatively homogeneous either one or two measurement points.
liquids. Accuracy is up to 0.5% of the flow.
The patented WideBeam technology SITRANS FUP1010 Portable Flowmeter for Check Metering
increases measurement precision by re- and Survey Applications
Analytical Instruments

ducing the sensitivity to any change in For applications that don’t need constant flow monitoring or pipes
the medium type or physical properties. The signal-to-noise ratio is where operators need to check the flow against a known or expected
and Systems

optimized by using the resonant frequency of the pipe wall to transmit value, Siemens offers portable clamp-on ultrasonic flowmeters.
the sound signal into the media, with the wall acting as a waveguide. This The SITRANS FUP1010 is available with a waterproof IP67 enclosure
method produces a focused, coherent signal that makes the technology that makes it ideal for outdoor use. The rugged, impact resistant plastic
particularly valuable for hydrocarbon and gas applications. case simply enables it to withstand rough treatment that would damage
For added flexibility, flowmeters are available that allow switching most other meters.
between Doppler and WideBeam to quickly adapt to varying conditions SITRANS FUP1010 operates on AC or DC power. It has an internal battery
without changing meters. that provides 4 hours of operation and can be recharged in 1.5 hours.
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
74

V 01.2018
FLOWMETERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS F US Clamp-On Ultrasonic Flowmeters


Flow Measurement
Instruments

With the dual channel version, switching between WideBeam and and specific gravity at base temperature and pressure at both reference
Doppler operation for quick adaptation to varying conditions can take and current operating conditions.
place without changing meters. This makes is suitable for any liquid; even The SITRANS FUH1010 for accurate standard volume/mass flow mea-
those with high aeration or suspended solids. Using the meter’s internal surement is required for high end application such as varying viscosity
datalogger, process history can be recorded and stored or downloaded liquids and multi-product pipelines. It’s also ideal for line balance ap-
to a PC or laptop. plications that require normalized volume or mass output.
Pressure Transmitter

Check Metering Kits Outputs are available for density and API. For even more precise density
compensation, analog inputs from densitometers, temperature sensors,
If you need a portable meter that needs to be
viscometers and pressure transmitters can be used.
moved often as part of a flow survey or flow check
measurement, pre-configured check metering kits SITRANS FUE1010 for Energy and Power Applications
are the ideal solution. They can be used for check-
ing the performance and accuracy of any type and The rugged, high precision SITRANS FUE1010 flowmeter is ideally
brand of flow or energy meter. suited for thermal energy and power applications, and large pipe sizes.
Kits come in rugged, weatherproof rolling cases with telescoping Key applications include high precision revenue grade sub-metering
handles. The case holds all the equipment — cables, multiple transducers of thermal energy production, chilled or hot water HVAC installations,
and the ultrasonic flow computer; no need to order extra parts. measurement of ammonia and glycol mixtures, and energy efficiency
monitoring of HVAC equipment and nuclear power plants.
Temperature Sensors

Clamp-on ultrasonic check metering kits are available for water and
As a stand-alone energy meter, the FUE1010 can be used as a remote
and Transmitters

wastewater, oil and gas, and energy industry applications.


communication module. Inputs from other data sources are transferred
Water and Wastewater Application Solutions into the built-in data logger, making it easy to time-stamp all data and
download it for billing, efficiency and operation analysis.
Ultrasonic WideBeam transit time and Doppler flowmeters are en-
gineered to measure a wide range of flow applications found in the
municipal water and wastewater industries.
They can be mounted on any pipe size and material, and range from
simple single meter installations to full flow metering or leak detection
systems in large distribution and collections systems plants.
Single, dual or four channel configurations facilitate the installation
on a very wide range of applications. Dual channel meters can be set
Wireless Sensing and

up on two separate applications and can also provide math functions


Communications

between the two channels. The same applies for the four channel meter,
which can monitor four lines and also has math and multipath functions.
SITRANS FUH1010 for Hydrocarbon Industry Applications
Siemens SITRANS FUH1010 meters are specifically designed to address
the needs of the hydrocarbon industry in applications where traditional
meters cannot perform.
• Continuous operation with highly aerated liquids
• Flow measurement under a wide range of viscosities
• Easy and quick installation with zero process down time
Analytical Instruments

• High performance under less than ideal flow profile conditions Flowmeter Software for Diagnostics and Data Analysis
Easy to use DataView software provides diagnostic capabilities, data
and Systems

SITRANS FUH1010 flowmeters are ideal for crude oil, refined petroleum
or liquefied gas applications. They are available in single, dual, three or logging and trending of meter performance. This diagnostic assures
four beam versions and use WideBeam technology for maximum accuracy. calibration and operational integrity. AGA-10 speed of sound calcula-
tion is incorporated in the software for speed of sound verification.
Clamp-on flowmeters for the hydrocarbon industry are available in
three different versions. The temperature- and pressure-compensated An internal AGA-8 table for fixed gas composition is available for
SITRANS FUH1010 interface detector offers extremely precise interface, standard volume computation. Single, dual, or optional four beam
crude oil and multi­product identification. It is ideal for scraper “pig” and versions are available along with rugged, stainless steel transducer
density indication. The system provides outputs for API number, density, enclosures permit permanent and direct burial installations.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
75

V 01.2018
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
FLOWMETERS

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797

Instruments
Quick Configurations for Popular Models
FUS1010 standard clamp-on flowmeter, FST020 basic clamp-on flowmeter, NEMA 4/
NEMA 4/IP65 enclosure. Includes two 0-10 IP65. Includes one 4–20 mA output per channel
VDC, two 4-20 mA and two 0-5 kHz pulse out- and 1 pulse output (single channel model only.)
puts and four Form C relay outputs, 90-240 VAC Transducer includes pipe mounting kit. Unit is
power, RS232 Modbus RTU communications.

Flow Measurement
UL, cUL, and CE approved standard.

Instruments
Issue all orders to: Siemens Industry Inc,
Issue all orders to: Siemens Industry Inc,
Model Selection Guide c/o Lesman Instrument Company
Model Selection Guide c/o Lesman Instrument Company
Catalog
Catalog
Description Number Price
Description Number Price
FST020 Basic Clamp-On Flowmeter, NEMA 4/IP65 7ME3570- $3509.00
FUS1010 Standard Clamp-On Flowmeter 7ME3530- $3857.00
Channels Single Channel 1H _ _ _- 0.00
Channels/ Single Channel 1AA00- 0.00
Beams Dual Channel/Dual Beam 2AA00- 949.00 Meter 100–240 VAC _ _ A00- 0.00
Power 11.5–28.5 VDC _ _ B00- 0.00
No Sensor 0A_ _ 0.00
C3 Universal, 13” Mounting Frame 0D_ _ 1621.00 No Transducer 0A _ _ 0.00
Channel 1 D3 Universal, 24” Mounting Frame 0E_ _ 1621.00 Channel 1 B3 Universal, 5” Track Mount 0C _ _ 1453.00

Pressure Transmitter
Transducer D1H High Precision 48” Mounting Frame 0P_ _ 2147.00 Transducer C3 Universal, 13” Mounting Frame 0D _ _ 1584.00
D2H High Precision 48” Mounting Frame 0Q_ _ 2345.00 D3 Universal, 24” Mounting Frame 0E _ _ 1584.00
Doppler Strap Kit up to 12” 0S_ _ 903.00 B2H High Precision, 5” Track Mount 0L _ _ 1636.00
Channel 2 No Transducer _ _A1 0.00 Sensor No Cables _ _ A0 0.00
Transducer D1H High Precision 48” Mounting Frame _ _P1 2147.00 Cables 1 x PVC-Jacket, 20’ _ _ B0 107.00
Doppler Strap Kit up to 12” _ _S1 903.00 1 x PVC-Jacket, 50’ _ _ C0 118.00
ID Tag Stainless Steel, Max 68 Characters ,Z-Y19 93.00 ID Tag Stainless Steel, Max 68 Characters ,Z-Y19 93.00
1 x PVC-Jacket, 20’ ,Z-K01 109.00
Sensor 1 x PVC-Jacket, 50’ ,Z-K02 121.00
Cable 1 x PVC-Jacket, 100’ ,Z-K03 213.00
1 x PVC-Jacket, 150’ ,Z-K04 354.00 Program your flowmeter
1 x PVC-Jacket, 200’ ,Z-K05 400.00
with an iPhone or iPad

Temperature Sensors
and Transmitters
SITRANS CONNECTION App for Apple iOS devices enables
direct serial communication between an iPhone, iPad, or
FUP1010 portable clamp-on flowmeter, IP67 iPod touch and any SITRANS F US clamp-on ultrasonic flow
weatherproof, battery powered. Includes RTD meter to enhance all meter functions, like programming,
mounting hardware and cable, pipe mounting kit operational review, and data logging and download.
and spacer bars for each transducer. Call for high SITRANS CONNECTION App makes connectivity possible
temperature transducers. without needing a laptop PC. It simplifies programming with
Issue all orders to: Siemens Industry Inc, a full alphanumeric keypad for easier navigation and parameter entry.
Model Selection Guide c/o Lesman Instrument Company Plus, it lets you share access to your terminal window with a qualified
Catalog
service technician (Wi-Fi or cellular service required).

Wireless Sensing and


Description Number Price
How to Order Flowmeter

Communications
FUP1010 Portable Clamp-On Flowmeter 7ME3510- $5136.00
Channels/ Single Channel 10C _ _ _- 0.00
You can order the SITRANS CONNECTION configuration...
IOS app through the Apple iTunes store or there’s an App
Beams Dual Channel/Dual Beam 20C _ _ _- 1033.00
from Siemens. When you order the software
No Sensor Cable _ _ _A0 _- 0.00 from Siemens, you’ll receive an iTunes for that!
Sensor 1 x PVC-Jacket, 20’ _ _ _B0 _- 140.00 redemption code. At that point, you can
Cable 2 x PVC-Jacket, 20’ _ _ _C0 _- 280.00
download the app from the iTunes store.
1 x PVC-Jacket, 50’ _ _ _D0 _- 185.00
2 x PVC-Jacket, 50’ _ _ _E0 _- 370.00 You will need to purchase a Siemens
Battery None _ _ _ _ 0- 0.00 cable kit to connect your Apple device to the Siemens clamp-on ultra-
Charger Charger Type K for U.S. (NEMA 5-15P) _ _ _ _ 5- 171.00 sonic flowmeter. Select the cable (or cables) you need based on your
No Transducer 0AA0 0.00 flowmeter model.
Analytical Instruments

Channel 1 A2 Universal, 3” Track Mount 0BA0 1588.00


Transducer B3 Universal, 5” Track Mount 0CA0 1588.00 Model Selection Guide
and Systems

C3 Universal, 13” Mounting Frame 0DA0 1968.00 Description Catalog No. Price
ID Tag Stainless Steel, Max 68 Characters ,Z-Y19 93.00 SITRANS Connection App: iTunes Redemption Code A5E32299678 $15.00
Cable Kit–IP67 FUP Weather Proof Portable Meter A5E32299677 242.00
Siemens portable clamp-on ultrasonic flowmeters Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (No Ext I/O) A5E32299675 184.00
are available for rent for survey metering Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (with Ext
I/O), IP40 FUE Portable, FUT, FST020 A5E32299674 140.00
applications.Call for details.
Compare SITRANS F US flowmeter models on page 72.
OPEN CHANNEL Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
76

V 01.2018
FLOW MONITOR Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797


Instruments

SITRANS LUT440 Open Channel Flow Monitor


• Industry-leading accuracy to ±0.04” (1 mm)
• Next generation Sonic Intelligence — improved performance in noisy environments
• Echo profile and trend view on the display for enhanced diagnostics
• Energy-saving algorithms and real time clock help you reduce pump operation
cost by avoiding peak energy periods
• HART® communications with access via panel interface,
Flow Measurement

SIMATIC PDM, Emerson handhelds, and web-browser


Instruments

• Graphical Quick Start Wizards guide you through setup


• Front interface with four-button programming, menu-driven
parameters, and Wizard support
• Datalogger records performance and alarm events Replaces
retired
• Wall, pipe, and DIN rail mounting configurations
Siemens
• Removable terminal strips for hassle-free wiring Milltronics
OCM-III
Pressure Transmitter

s
A complete LUT440 See transducer
system includes: on pages 34 -3 5. An ultrasonic trans-
ducer above the primary
1. Controller device emits a pulse that
2. Echomax transducer strikes the liquid target
3. Additional cable lengths, as and is reflected back as
necessary an echo.
4. Optional sensor mounting The transmit and return
flanges and aiming kits, as times are converted to
necessary digital indications of head,
flow rate, and totalized
flow.
Temperature Sensors
and Transmitters

Specifications
Range: 1 to 200 ft, transducer and material dependent Ordering Instructions
Accuracy: ±1 mm (0.04”) plus 0.17% distance; High ac- Select one option from each table section below. A complete catalog number looks like this:
curacy: ± 0.04” (1 mm), within 10 feet (3 m) range 7ML5050-_ _ _ _ _ - _ _ _ _ -Z
Resolution: Greater of 0.1% measured range or 0.08” Please submit orders to: Siemens Industry Inc,
Temperature: Ambient: -4° to 122° F (-20° to 50° C); Ap- Model Selection Guides c/o Lesman Instrument Company.
plication: -40° to 302° F (-40° to 150° C) Description Catalog Number Price
Interface: Back-lit LCD; Removable display, operational SITRANS LUT440 Ultrasonic Open Channel Flow Monitor 7ML5050-0C_ _ _ $ 1936.00
Wireless Sensing and

up to 5 m (16 ft) from enclosure base


Communications

Enclosure With display A _ _- 135.00


Communications: HART®, USB Display With remote panel mount display B _ _- 306.00
Programming: Four local push buttons, SIMATIC PDM Options No display (blank lid provided) C _ _- 0.00
Emerson AMSTM, web browser (Internet Explorer), Field Input 100 to 230 VAC ± 15% _ _ _ 1 _- 0.00
Device Tool (DT), Emerson FC375/FC475 Voltage 10 to 32 VDC _ _ _ 2 _- 0.00
Output: Three relays: One Form C (SPDT) relay, two Form Cable Inlet 3 cable inlets, cable glands not supplied _ _ _ _ 1- 0.00
A (SPST) relays; One 4–20 mA output (active or passive) 3 cable inlets, 3 M20 cable glands supplied ____2- 17.00
Input: Two discrete inputs (0-50 VDC max switching level) Approvals General purpose CE, FM, CSA US/C, UL, C-TICK 1DA0 0.00
with 24 VDC bias for contact level device and/or pump CSA Class I, II, III, Div 2 Groups A–G 1DC0 66.00
interlock; One temperature sensor input for optional Optional Manufacturer’s test certificate -Z-C11 25.00
TS-3 temperature sensor Adders Stainless steel tag: Max. 27 char plain text -Z-Y15 18.00
Analytical Instruments

Enclosure: Wall/Pipe/DIN Rail mount; 1/2 DIN; Type 4X/ Preset Namur NE43 failsafe setting – <3.6mA -Z-N07 43.00
NEMA 4X/IP 65, panel mount display IP 54 (Type 3/ Documen- Printed English User Manual 7ML1998-5MV01 48.00
and Systems

NEMA 3/IP 54); Polycarbonate. Use of the knock-out tation Printed Quick-Start Guide 7ML1998-5XU81 43.00
on the blind lid for the panel mount version reduces the Printed Communications Manual 7ML1998-5NE01 31.00
electronics enclosure rating to IP 20/NEMA 1. Accessories Tag, stainless steel, 0.47 x 1.77”, one text line 7ML1930-1AC 48.00
Power: AC version: 100 to 230 VAC ±15%, 50/60 Hz, 36 VA Panel Mount Cable Extension 2.5 m (8.2 ft) 7ML1930-1GF 57.00
10 W; DC version: 10 to 32 VDC 10W Cable Glands and Retaining Nuts (3-Pack) 7ML1930-1GB 20.00
HART Modem, USB 7MF4997-1DB 603.00
Approvals: General purpose: CE.CSAUS/C, FM, UL Listed, LUT400 Sunshield, 304 Stainless Steel 7ML1930-1GE 235.00
C-TICK; Hazardous location: CSA Class I, II, III, Division 2
(Groups A–G), CE, ATEX 3D, IECEx, C-TICK Want to add a TS-3 temperature sensor? Call Lesman for pricing.

You might also like