Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Meic - 511: Fluidsim Components

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 11

MEIC – 511

FluidSIM
Components
Student Name: PAJE, JEANUEL ROGER RENDELL A.
TAPAYAN, JOHN FRANCIS D.
ANABO, JUSTIN RUSSELL M.
RUIZ, CARLOS JERICHO B.
MATEO, LESTER AERON E.
VIAÑO, RICHMOND L.
Section: MEIC-511
Instructor Name: ENGR. GEMM LOUCON MANGANTI
SUPPLY ELEMENTS

Compressor, adjustable

The adjustable compressor provides the necessary c


the maximum flow rate can be adjusted under actual o
in the simulation. The pressure is restricted to the pre

Adjustable parameters

Operating pressure: 0 ... 2 MPa

Max. flow rate: 0 ... 5000 l/min

Related Topics
Compressed air supply
Compressor
COMPRESSOR, ADJUSTABLE
The adjustable compressor provides the necessary compressed air, whereby the
maximum flow rate can be adjusted under actual operating conditions and in the
simulation. The pressure is restricted to the preset operating pressure.
Adjustable parameters
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)
Filter, manual condensate drain

The compressed air filter removes contam


The size of the filterable particles is depen
Condensation, which can occur through si
of the compressed air, can be manually dr

Adjustable parameters

Standard nominal flow rate: 0.1 ... 5

Related Topics
Filter
Filter, automatic condensate drain
[10] Compressed air filter

FILTER, MANUAL CONDENSATE DRAIN


The compressed air filter removes contamination from the compressed air. The size of
the filterable particles is dependent upon the filter class. Condensation, which can occur
through sinking temperatures or the expansion of the compressed air, can be manually
drained off.
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
ACTUATORS

Multiple position cylinder

By connecting two cylinders of same piston diameter


stroke three piston stop positions can be realized. Fro
the third stop can be reached either directly or via the
that the maximum stroke of the second piston must b
preceding one. When moving back, an intermediate s
control. The shorter maximum stroke is half of the oth

Adjustable parameters

Force: -1000 ... 1000 N

Max. stroke: 1 ... 2000 mm

Piston position: 0 ... Max. stroke m

Intermediate Stop: 0 ... Piston positio

Piston Area: 0,25 ... 810 qcm

Piston Ring Area: 0,1 ... 750 qcm

Related Topic
Double acting cylinder

MULTIPLE POSITION CYLINDER


By connecting two cylinders of same piston diameter but different maximum stroke
three piston stop positions can be realized. From the first stop position the third stop can
be reached either directly or via the intermediate stop. Note that the maximum stroke of
the second piston must be larger than the preceding one. When moving back, an
intermediate stop requires a particular control. The shorter maximum stroke is half of
the other maximum stroke.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 1 ... 1000 mm (8)
Total stroke: 1 ... 2000 mm (200)
Piston Position: 0 ... 2000 mm (0)
Intermediate position: 0 ... 1000 mm (0)
External force: -10000 ... 10000 N (0)

Vacuum suction nozzle

The vacuum suction nozzle creates its vacuum based


In this case, compressed air flows from connection 1
connection 1v. A sucker can be connected to the vacu
Stopping the input of compressed air at connection 1

VACUUM SUCTION NOZZLE


Related Topic
Adjustable vacuum actuator valve
The vacuum suction nozzle creates its vacuum based on the ejector principle. In this
case, compressed air flows from connection 1 to 3, creating a vacuum at connection 1v.
A sucker can be connected to the vacuum connection 1v. Stopping the input of
compressed air at connection 1 stops any suction also.
Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)
VALVES

12v 1 3
Low pressure amplifier unit, 2 compartments

Each of the two double-level low press


3/2 directional valve that is normally clo
raised to a higher boost pressure level
amplifier and is put out by connection 2

Adjustable parameters

Standard nominal flow rate: 0.1

Related Topic
Ring sensor

LOW PRESSURE AMPLIFIER UNIT, 2 COMPARTMENTS


Each of the two double-level low pressure amplifier units has the function of a 3/2
directional valve that is normally closed. The signal at connection 12 is raised to a
higher boost pressure level through the use of a double-level amplifier and is put out by
connection 2.
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
2

3
12
1 10
Pneumatic counter

The counter registers pneumatic signals starting a


and counting backwards. If zero is reached, then th
signal. This output signal continues until the counte
from at signal at connection 10.

Adjustable parameters

Counter: 0 ... 9999 pulse

Standard nominal flow rate: 0.1 ... 5000 l/mi

Related Topic
Relay counter

PNEUMATIC COUNTER
The counter registers pneumatic signals starting at a predetermined number and
counting backwards. If zero is reached, then the counter releases an output signal. This
output signal continues until the counter is reset either by hand or from at signal at
connection 10.
Adjustable parameters
Counter: 0 ... 9999 (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
VALVE GROUPS

Stepper module, type TAA

The stepper module is made up of a memory unit (3/2-w


AND and an OR component, a viewable announcemen
manual operation.

Adjustable parameters

Initial position: Left, Right

Related Topic
Stepper module, type TAB

STEPPER MODULE, TYPE TAA


The stepper module is made up of a memory unit (3/2-way impulse valve), an AND and
an OR component, a viewable announcement, and an auxiliary manual operation.
Adjustable parameters
Initial Position: Left, Right (Left) Desired position: 0 ... 2 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
2

10

Time delay valve, normally open


3
1

The time delay valve is made up of a pneumatica


one-way flow control valve, and small air accumu
pressure is reached at the control connection 10
switches and stops the flow from passing betwe

Adjustable parameters

Opening level: 0 ... 100 %

Volume: 0.001 ... 100 L

Standard nominal flow rate: 0.1 ... 5000 l/m

Related Topics
TIME DELAY VALVE, Time
NORMALLY OPENclosed
delay valve, normally
One-way flow control valve
The time delay valve is made up of a pneumatically operated 3/2way valve, a one-way
3/2-way valve, pneumatically operated, normally open
flow control valve, and small air accumulator. When the necessary pressure is reached
at the control connection 10 of the unit, the 3/2-way valve switches and stops the flow
from passing between 1 and 2.
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min (10)
Volume: 0.001 ... 100 l (0.01)
Standard nominal flow rate (Directional valve): 0.1 ... 5000 l/min (50)
MEASURING INSTRUMENTS

Pressure indicator

An optical signal is activated when the pressure a


pressure indicator exceeds the preset switching p

Adjustable parameters

Switching pressure: 0.0001 ... 2 MP

Color: 16 standard c

Related Topics
Manometer
Flow meter
PRESSURE INDICATOR
An optical signal is activated when the pressure at the connection to the pressure
display exceeds the preset switching pressure.
Adjustable parameters
Switching pressure: -0.1 ... 40 MPa (3)
Color: 16 standard colors (Blue)
Pressure sensor, analog

This symbol represents the pneumatic part of


analog pressure sensor measures the adjac
into a proportional electrical voltage signal. In
the specified pressure ranges are considered
in the voltage range from 0 V to 10 V is repres
delivers 0 V and the maximum pressure 10 V.

Related Topics
Pressure sensor, analog
PRESSURE SENSOR, ANALOG
Coupling Pneumatics, Electrics and Mechanics
This symbol represents the hydraulic
Open-loop part of the
and Closed-loop analog
Control pressure sensor. The analog
by using
pressure sensor measuresContinuous
the adjacent
Valves pressure and transforms it into a proportional

electrical voltage signal. In the process, only pressures in the specified pressure ranges
are considered. Within this range, the pressure in the voltage range from 0 V to 10 V is
represented, i.e. the minimum pressure delivers 0 V and the maximum pressure 10 V.
Adjustable parameters
Minimum pressure: -40 ... 40 MPa (0)
Maximum pressure: -40 ... 40 MPa (10)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)

You might also like