Elective-I: Advanced Steel Design: M.Tech. First Semester (Structural Engineering) (C.B.C.S.)

This document outlines an exam for an advanced steel design elective, providing 10 potential design problems to solve worth 14 marks each, covering topics like welded beam-column connections, framed beam-column connections, steel chimney design, gantry girder design, industrial portal frame design, foot bridge truss member design, factors for bridge type selection, rectangular water tank design, and circular water tank design. Students are instructed to solve one question from questions 1-2, one from 3-4, and so on, for a total of 70 marks. Relevant codes and assumptions are referenced.

Uploaded by

Dhiraj Nimje
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
219 views

Elective-I: Advanced Steel Design: M.Tech. First Semester (Structural Engineering) (C.B.C.S.)

This document outlines an exam for an advanced steel design elective, providing 10 potential design problems to solve worth 14 marks each, covering topics like welded beam-column connections, framed beam-column connections, steel chimney design, gantry girder design, industrial portal frame design, foot bridge truss member design, factors for bridge type selection, rectangular water tank design, and circular water tank design. Students are instructed to solve one question from questions 1-2, one from 3-4, and so on, for a total of 70 marks. Relevant codes and assumptions are referenced.

Uploaded by

Dhiraj Nimje
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

M.Tech. First Semester (Structural Engineering) (C.B.C.S.

)
Elective-I : Advanced Steel Design
P. Pages : 2 NKT/KS/17/8111
Time : Three Hours *1342* Max. Marks : 70
_____________________________________________________________________
Notes : 1. All questions carry marks as indicated.
2. Solve Question 1 OR Questions No. 2.
3. Solve Question 3 OR Questions No. 4.
4. Solve Question 5 OR Questions No. 6.
5. Solve Question 7 OR Questions No. 8.
6. Solve Question 9 OR Questions No. 10.
7. Due credit will be given to neatness and adequate dimensions.
8. Assume suitable data whenever necessary.
9. Illustrate your answers whenever necessary with the help of neat sketches.
10. Use of non programmable calculator is permitted.
11. 15800-1984, 15800-2007 structural steel table may be consulted

1. An ISMB 300 transmit end reaction of 200kN and bending moment of 90kN-m to the 14
flange of column ISHB 300 @ 576.8N/m. Design a welded connection.

OR

2. Design a framed connection at the end of a beam ISMB 300, 8 m span, carrying a total 14
UDL of 20 kN/m with flange of a column ISMB 500.

3. Explain in detail load effect on self supporting chimney and on cantilever chimney. 14

OR

4. Design a steel chimney to the following particulars: - 14


- height of the chimney – 60 m
- diameters of the chimney – 5 m
- thickness of the lining – 110 mm
- wind pressure – 1.5 kN/m2 of flat vertical surface.

5. Design a suitable section for gantry girder to be used to carry electrically operated single 14
crane. Use following data:
i) Crane capacity = 300 kN
ii) Span of gantry girder = 7.5m
iii) End clearance = 1.3m
iv) Wheel base = 2.6m
v) c/c of gantry rails = 12m
vi) Weight of crab = 50 kN

OR

NKT/KS/17/8111 1 P.T.O
6. The industrial portal frame shown in fig. 1 (Dimensions are in m) 14
• Design of column
• Design of beam
30kN/m

8m

6m

Fig. 1

7. For a 'N' type foot bridge truss, design on top, one bottom and one vertical member using 14
following data.
i) Span of truss = 16 m (8 panels @ 2m c/c)
ii) Height of truss = 2m
iii) Width of pathway = 3m
iv) L. L = 4 kN/m2
v) 100 mm thick wooden flooring

OR

8. State the various factors for selection of type of bridges. Explain in detail. 14

9. An overhead rectangular water tank consists of a container of plan dimension 7m x 10m 14


and height is 2.5m. The tank was supported on four columns, c/c distance between columns
along shortes span is 6m, while in longer direction is 9m, design bottom plate of container
and upper tier of beams. Assume spacing and number of beams.

OR

10. Design circular steel water tank for a capacity of 100000 litres. The height of staging is 14
12m from ground level. Depth of tank shall not exceed 2.0m.

*********

NKT/KS/17/8111 2