Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Turn On Your Profits: Super Large 5-Inch LCD

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Turn On

Your Profits
Super Large
5-inch LCD

Export Control

30% PV Oversizing

30% Lighter

DT Series 17KW 20KW 25KW


Dual-MPPT, Three-Phase
The GoodWe DT series inverter is suitable for commercial and industrial roofs as well as small and medium-sized
photovoltaic power systems. Because of the reliable grid support capabilities, high waterproof and dustproof
grade and extra-wide voltage range of module, it can not only be used in commercial roof and commercial
power station PV systems, but also is qualified for the design requirements of large-megawatt power stations.

www.goodwe.com
Technical Data GW17K-DT GW20K-DT GW25K-DT

Max. DC Input Power (W) 22100 26000 32500


Max. DC Input Voltage (V)* 1000 1000 1000
MPPT Range (V) 260~850 260~850 260~850
PV String Input Data

Start-up Voltage (V) 250 250 250


MPPT Range for Full Load (V) 400~850 470~850 480~850
Nominal DC Input Voltage (V) 620 620 620
Max. Input Current (A) 22/22 22/22 27/27
Max. Short Current (A) 27.5/27.5 27.5/27.5 33.8/33.8
No. of MPP Trackers 2 2 2
No. of Input Strings per Tracker 2 2 3

Nominal Output Power (W) 17000 20000 25000


Max. Output Apparent Power (VA) 17000 20000 25000
AC Output Data

Nominal Output Voltage (V) 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE
Nominal Output Frequency (Hz) 50/60 50/60 50/60
Max. Output Current (A) 25 30 37
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output) <1.5% <1.5% <1.5%
Efficiency

Max. Efficiency 98.2% 98.4% 98.4%

Euro Efficiency 97.7% 98.1% 98.1%

Anti-islanding Protection Integrated Integrated Integrated


Input Reverse Polarity Protection Integrated Integrated Integrated
Insulation Resistor Detection Integrated Integrated Integrated
Protection

DC SPD Protectioin Integrated Integrated Integrated


Residual Current Monitoring Unit Integrated Integrated Integrated
Output Over Current Protection Integrated Integrated Integrated
Output Short Protection Integrated Integrated Integrated
Output Over Voltage Protection Integrated Integrated Integrated

Operating Temperature Range (°C) -25~60 -25~60 -25~60


Relative Humidity 0~100% 0~100% 0~100%
Operating Altitude (m) ≤4000 ≤4000 ≤4000
Cooling Fan Cooling Fan Cooling Fan Cooling
Noise (dB) <45 <45 <45
General Data

User Interface LCD & LED LCD & LED LCD & LED
Communication RS485 or WiFi RS485 or WiFi RS485 or WiFi
Weight (kg) 39 39 40
Size (Width*Height*Depth mm) 516*650*203 516*650*203 516*650*203
Protection Degree IP65 IP65 IP65
Night Self Consumption (W) <1 <1 <1
Topology Transformerless Transformerless Transformerless
Certifications & Standards

Grid Regulation VDE0126-1-1, VDE-AR-N 4105, VDE0126-1-1, VDE-AR-N 4105, VDE0126-1-1, VDE-AR-N 4105,
AS4777.2, G83/2, EN50438(PL), AS4777.2, G83/2, EN50438(PL), AS4777.2, G83/2, EN50438(PL),
EN50438(SW), EN50438(IR), EN50438(SW), EN50438(IR), EN50438(SW), EN50438(IR),
NRS 097-2-1, ERDF-NOI-RES_13E, NRS 097-2-1,ERDF-NOI-RES_13E, NRS 097-2-1, ERDF-NOI-RES_13E,
IEC61727, IEC62116 IEC61727, IEC62116, MEA, PEA IEC61727, IEC62116

Safety Regulation IEC62109-1&2 IEC62109-1&2 IEC62109-1&2


EMC EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4

*: Maximum operating voltage is 950V.