GEN3 Plus Microinverter


TSOL-MS1600 TSOL-MS1800 TSOL-MS2000

Maximized Flexibility Safety Reliability


Efficiency
Individual optimization, Plug & play installation, Max. DC voltage 60V. No Die casting design and glue
se-parate dedicated MPPT Easy to install. threat for high DC voltage. filling technology. Better
for each panel. thermal dissipation.
Integrated LoM protection
New topology design, max. function. Ensure the safety Standard 12 years warranty,
efficiency up to 96.7%. of power grid. Quality guaranteed.

VDE 0126 VDE 4105 EN 50549 INMETRO RD 1699 G 98

TSUNESS Co,. Ltd


sales@tsun-ess.com www.tsun-ess.com +86-512-66186028
Technical Data
Model TSOL-MS1600 TSOL-MS1800 TSOL-MS2000

Input(DC)
Recommended Module Power [W] 300-700+ 300-700+ 300-700+
Start up Voltage [V] 22 22 22
MPPT Voltage Range [V] 16-60 16-60 16-60
Max. Input Voltage [V] 60 60 60
Max. Input Current [A] 16 16 16
Max. Input Short-circuit Current[A] 25 25 25
Quantity of MPPT 4 4 4
Output [AC]
Max. Continous Output Power [VA] 1600 1800 2000
Nominal Continous Output Power [W] 1600 1800 2000
Nominal Output Current [A] 7 7.8 8.7
Max. Output Current [A] 8 9 10
Nominal Output Voltage [V] 220/230/240, L/N/PE
Nominal Frequency [Hz] 50/60
Power Factor >0.99 default, 0.8 leading … 0.8 lagging
Output Current Harmonic Distortion <3%
Max. Units Per Branch 3 2 2
Efficiency
Peak Inverter Efficiency 96.7%
CEC Weighted Efficiency 96.5%
Nominal MPPT Efficiency 99.9%
EU Efficiency 96.3%
Night Time Power Consumption [mW] < 50
Mechanical Data
Dimensions [WxHxD mm] 331 * 218 * 40
Weight [kg] 5.5
Type of Enclosure IP67
Cooling Natural Convection
Environmental Data
Operating Ambient Temperature Range [℃] -40 ℃ to 65℃
Operating Internal Temperature Range [℃] -40 ℃ to 85℃
Relative Humidity 0-100% condensing
Max. Operating Altitude Without Derating [M] 2000
Monitor Integrated WiFi
Protection
Anti-Islanding protection Integrated
Insulation monitoring Integrated Diagram
AC surge protection TYPE II
3
AC overcurrent protection Integrated
MS1600
AC short-circuit protection Integrated
AC over/under voltage protection Integrated
AC over/under
frequency protection Integrated

Over-heat protection Integrated