Actimed:, The Following Versions Are Available
Actimed:, The Following Versions Are Available
Actimed:, The Following Versions Are Available
Prüftechnik
für Medizin
und Industrie
ACTIMED
Test and management software
Because of the constant extension and improvement of the ACTIMED software, the following
versions are available:
ACTIMED 4.12
ConActX-test module 1.95
ConActX 2.77
at one’s disposal. For further updates please contact our technical support
S.P.L. Elektronik
Forstweg 1
D - 14656 Brieselang
GERMANY
http://www.spl-elektronik.com
2. Update
Proceeding:
For 64-bit systems, please make sure that you are using the 32-bit ODBC Data Source
Administrator! If this is not found in the system control, this can also be manually started under
"\Windows\SysWOW64\odbcad32.exe".
With "configuration..." the path indication must be set for both data sources:
e.g. D:\tree name\actimed3db.mdb.
REGEDIT4
[-HKEY_CURRENT_USER\Software\ODBC\ODBC.INI\CxTmDB]
[HKEY_LOCAL_MACHINE\Software\ODBC\ODBC.INI\Actimed_3DB]
"DBQ"="C:\\Programme\\ConActX\\Data\\ACTIMED3DB.mdb"
[HKEY_LOCAL_MACHINE\Software\ODBC\ODBC.INI\CxTmDB]
"DBQ"="C:\\Programme\\ConActX\\Data\\ACTIMED3DB.mdb"
Windows are creating a user-related, so called, “VirtualStore”, in which some folders and files are
mirrored or reflected.
Therefore, unusual effects may occur sometimes, e.g. when the folder C:\Program Files\ConActX\
is mirrored in the folder C:\Users\USERNAME\appData\Local\VirtualStore\ConActX, e.g.:
We recommend you to give the user a full access to the directory C:\Program Files\ConActX,
which happens like this:
• Within the Windows Explorer, select the directory C: \ Program Files \ ConActX, press the
right mouse button and select "Properties".
• In the new window select the "Security" tab and click on the "Edit" button right below the
"Group or User Name" tag.
• Please select the "user (account name \ user)" and after that ", click on "Full access" in the
lower "User permissions" window under "Allow".
• Now click on "Accept" or "OK" to confirm it.
• This should give the user all access and write permissions for the ConActX folder and
subdirectories.
If the VirtualStore has once been activated, it has proven itself as a workaround to move the
ConActX folder from the VirtualStore to a non-mirrored folder (see above). If they do not show their
expected data, they are most likely contained in the folder which was previously moved from the
VirtualStore. In this case, you should copy the database of the previously moved folder to your
ACTIMED installation.
5. Help
Start ConActX and check under "Configuration" tab whether values are contained in the fields or
not. If not, select a value in the pull-down menus. Considering that, it does not matter which one
you choose, it must only contain something in it.
In ACTIMED 4 there was a little change in the printer layout. To use old ACTIMED 3 print layouts
with ACTIMED 4, a small change to the layout is necessary with the designer. In order to do this,
be sure to follow these steps:
• Before making a change in an existing layout, make backup of it. A layout consists of 3
files: *.lsp, *.lst and *.lsv.
• If the layout files of the ACTIMED 3 test report are not already in the folder
"ConActX\ACTIMED_4\ Reports\Report\", please copy the related *.lsp, *.lst and *.lsv files
into it.
• In this step, the layout must be opened with the program/application “Designer”.
• If there is a test report which has not been edited yet, but is opened in the designer, the
following expression error appears:
With ACTIMED 4, there are two new variables for the report available: Hardware_Version and
Software_Version. If you want to use these new variables in your old ACTIME 3 report, you have
to add them within the Designer.
5.3 Display / rendering issues
Here is a small tutorial to help you to solve display/rendering issues with ACTIMED:
• Please check your settings by pressing the right mouse button on the desktop and then
clicking on "Properties".
• In the "Display Properties" window, select the "Design" tab and set it to "Windows -
Classic".
• Within the tab "Settings", you will find the "Advanced" button. Click on it with the mouse and
a window which says "Properties of ............." will appear.
• The “DPI setting” under the “General” tab should be set to “Normal size (96 DPI)”.
If that’s the case, all windows within ACTIMED should be displayed correctly.
If you still have display / rendering issues, please update your graphic card driver and restart
Windows.
Other named products in particular are trademarks or registered trademarks of their respective
companies
Yours sincerely
S.P.L. Elektronik