Ultrasonic Flowmeter D118
Ultrasonic Flowmeter D118
Ultrasonic Flowmeter D118
About D118
Applications
1
Ultrasonic Flowmeter D118
Specification
Performance specifications
Flow range ±0.03ft/s ~ ±40ft/s (±0.01m/s ~ ±12m/s)
Accuracy ±0.5% of measured value (for ±1.5ft/s~±40ft/s)
Repeatability 0.15% of measured value
Linerarity ±0.5%
Pipe size 1" to 200"(25mm to 5000mm)
Function specifications
Communication RS232&RS485
Standard SD card
SD Card Max record:512days
Record time interval
Power supply 90 to 245 VAC, 48 to 63 Hz. Or 10 to 36VDC
Keypad 22 keys with tactile action
Display 40 character, 2 line (20 X 2) lattice alphanumeric, back lit LCD.
Transmitter:-40℉~140℉(-40℃~60℃)
Temperature
Transducer:-40℉~176℉(-40℃~80℃,standard)
Humidity Up to 99% RH,non-condensing
Physical specifications
Transmitter NEMA 4X (IP65), Die-cast aluminum
Encapsulated design
Transducer double-shielded transducer cable
Standard/maximum cable length:30ft/1000ft(9m/305m)
2
Ultrasonic Flowmeter D118
Wiring Diagram
Transmitter Dimensions
Transmitter
200mm 98mm
Model:D118
198mm
^ /+
cool heat temp
cap.
4 cap. 5 6
flow sound signal
vel. Enter
vel.
7 8 9
^
cal.
.
zero
0
diag.
< /-
Transducer
56mm
24mm
25mm
32mm
MODEL:D118 Transducer
ANBIENT TEMPERATURE(MAX):80℃
CERTIFICATION:Ex ia II BT6
ENCLOSURE:IP68
FLOW
3
Ultrasonic Flowmeter D118
Flow
Downstream Transducer Pipe Strap
Top View
Flow
Transducer space
w
Flo Downstream Transducer Pipe Strap
Top View
Flow
Transducer space
4
Ultrasonic Flowmeter D118
Vertical
L≥5D
L≥10D
L≥5 0 D
5
Ultrasonic Flowmeter D118
Ordering Information
Description
Digital Correlation Transit Time Flowmeter
Installation method: Wall mount
2G SD card high memory data logging, maximum memorize 512 days data.
Flow Range: 0.03 ~ ±40ft/s (0.01~ ±12 m/s)
Accuracy: ±0.5% of measured value
Repeatability: 0.15%
D118 Pipe Size Range: 1″~200″(25mm ~ 5000mm)
Keyboard:16 (4×4) touch keys
Display: 20*2, alphanumeric, backlit LCD
Power supply: 90-250VAC, 48-63 Hz or 10-36V DC
Transmitter enclosure: IP65, die-cast aluminum machined enclosure
Output: 4~20mADC, OCT pulse output, relay output
Communication: RS-232 / RS-485 terminal Modbus Protocol
Output
1 4-20mA, OCT pulse output, relay output, RS-232 / RS-485
4-20mA, OCT pulse output, relay output, RS-232 / RS-485, RTD temperature
2 input
Transmitter enclosure area classification
1 IP65, die-cast aluminum machined enclosure
2 Explosion-proof enclosure , Ex dia II BT4
Type of transducers
C010 Clamp on transducer, Operating temperature:-40℉ ~ + 176℉(-40℃ ~ + 80℃)
CH020 High temperature Clamp on transducer:32℉ ~ + 302℉(0℃ ~ + 150℃)
W210 Insertion transducer, Operating temperature: - 40℉ ~ + 176℉( - 40℃ ~ + 80℃)
WH101 High temperature Insertion transducer:32℉ ~ + 302℉(0℃ ~ + 150℃)
Transducer Cable Length
030 Standard 30ft (9m)
6
Ultrasonic Flowmeter D118
Product Line
Accuracy: Accuracy:
±1% ±1%
Flow range: Flow range:
0.03 ~±16ft/s 0.03 ~ ±40ft/s
Pipe Size Range: Pipe Size Range:
1″~48″ 1″~48″
Accuracy: Accuracy:
±0.5% ±0.5%
Flow range: Flow range:
0.03 ~ ±40ft/s 0.03 ~ ±40ft/s
Pipe Size Range: Pipe Size Range:
1″~200″ 0.6″~240″
Accuracy:
Prefect performance in single liquid medium.
±0.5%
Eg:Water,Pure water,Beer,Oil, etc.
Flow range:
0.03~±40ft/s
Pipe Size Range:
1''~200''
Remark:The above mode choose doesn’t including the spool piece,it is for customization.
Version:D118-201601