Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Masonry Beam Design Based On TMS 402-16/13: V F D B

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Masonry Beam Design Based on TMS 402-16/13
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES ) 0 No, (reduced fm' by 0.5)
TYPE OF MASONRY ( 1=CMU, 2=BRICK ) 1 CMU
MASONRY STRENGTH fm' = 1.5 ksi
REBAR YIELD STRESS fy = 60 ksi

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2) Yes


SERVICE SHEAR LOAD V = 4.56 k
SERVICE MOMENT LOAD M = 13.68 ft-k
WIDTH b = 8 in
EFFECTIVE DEPTH d = 45 in
CLEAR SPAN Lc = 12 ft
LOAD TYPE (1=SEISMIC, 0=WIND, 5=GRAVITY) 1 Seismic [THE BEAM DESIGN IS ADEQUATE.]
VERTICAL REINF. 1 # 4 @ 8 in o.c.
TENSION REINFORCEMENT 2 # 6

ANALYSIS
ALLOWABLE STRESS FACTOR SF = 0.667
ALLOWABLE REINF. STRESS (1.33 or 1.0) Fs = 32 ksi
ALLOWABLE MASONRY STRESS Fb=(SF)(0.33fm') = 0.33 ksi
MASONRY ELASTICITY MODULUS Em = 1350 ksi, (TMS 402 4.2.2)
STEEL ELASTICITY MODULUS Es = 29000 ksi, (TMS 402 4.2.2)
EFFECTIVE WIDTH bw = 7.63 in [Satisfactory, Lc < 32 bw]
MODULAR RATIO n = 21.48
TENSION REINFORCEMENT RATIO r = 0.003

THE NEUTRAL AXIS DEPTH FACTOR IS THE LEVER-ARM FACTOR IS

k
k  2rn   rn   rn j  1
2
= 0.281 = 0.906
3
THE TENSILE STRESS IN REINFORCEMENT DUE TO FLEXURE IS

M
fs = 4.57 ksi < Fs [SATISFACTORY]
A s jd
THE COMPRESSIVE STRESS IN THE EXTREME FIBER DUE TO FLEXURE IS

2M
fb = 0.08 ksi < Fb [SATISFACTORY]
jk b w d 2
THE SHEAR STRESS IN MASONRY IS

V   Av F sd  ' 
fv = 13.3 psi < F v  MIN  SF  1.125 f m  0.5 
'
 ,  SF  2 f m
b wd   A nS  
(TMS 402 8.3.5)
= 51.6398 psi [SATISFACTORY]
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Masonry Beam Design Based on UBC 97
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES ) 1 Yes, (Sec. 2107.1.2)
TYPE OF MASONRY ( 1=CMU, 2=BRICK ) 1 CMU
MASONRY STRENGTH fm' = 1.5 ksi
REBAR YIELD STRESS fy = 60 ksi
ALLOWABLE INCREASING ? (UBC/CBC 1612.3.2) Yes
SERVICE SHEAR LOAD V = 15.1 k
SERVICE MOMENT LOAD M = 83 ft-k
WIDTH b = 12 in
EFFECTIVE DEPTH d = 40 in
CLEAR SPAN Lc = 12 ft
LOAD TYPE (1=SEISMIC, 0=WIND, 5=GRAVITY) 5 Gravity Only [THE BEAM DESIGN IS ADEQUATE.]
VERTICAL REINF. 1 # 4 @ 8 in o.c.
TENSION REINFORCEMENT 2 # 7

ANALYSIS
ALLOWABLE STRESS FACTOR SF = 1.333
ALLOWABLE REINF. STRESS (1.33 or 1.0) Fs = 32 ksi
ALLOWABLE MASONRY STRESS Fb=(SF)(0.33fm') = 0.66 ksi
MASONRY ELASTICITY MODULUS Em = 750 fm' = 1125 ksi, (Eq. 6-4. 2106.2.12.1)
STEEL ELASTICITY MODULUS Es = 29000 ksi
EFFECTIVE WIDTH bw = 11.63 in [Satisfactory, Lc < 32 bw]
MODULAR RATIO n = 25.78
TENSION REINFORCEMENT RATIO r = 0.0026

THE NEUTRAL AXIS DEPTH FACTOR IS THE LEVER-ARM FACTOR IS

k
k  2rn   rn   rn
2 = 0.304 = 0.899
j  1
3
THE TENSILE STRESS IN REINFORCEMENT DUE TO FLEXURE IS

M = 23.09 ksi < Fs [SATISFACTORY]


fs
A s jd
THE COMPRESSIVE STRESS IN THE EXTREME FIBER DUE TO FLEXURE IS

2M 0.39 ksi Fb
fb = < [SATISFACTORY]
jk b w d 2
THE SHEAR STRESS IN MASONRY IS


< 51.64 psi
F v   SF  MIN ( f
'
m , 50) 
V = 36 psi [SATISFACTORY]
fv
jb wd
F v   SF  MIN (3 f m , 150) 
(Sec. 2107.2.17) < ' 154.92 psi [SATISFACTORY]

CHECK THE MINIMUM AREA OF SHEAR REINFORCEMENT REQUIRED :

V 0.14 in2 / ft < Av  0.30 in2 / ft ( No shear reinf. Reqd )



F sd s

You might also like