This document contains important information about the Altivar Machine ATV340 DTM Library software
component and Release Content.
1. Package Content
2. Features
> Parameter graphical sketch views for Analog Encoder, Resolver and Digital Encoder (SSI configuration)
> Support for EtherCAT option card Support of PROFINET option card.
> Parameters can now be added into the IO scanner list via entering the logical address.
> Light weight DTM with reduced size before and after Installation.
> My Dashboard section to configure and monitor drive parameters in a single screen.
> parameter layout tab to configure drive parameters in a graphical and user guided interface. .
> Diagnostic Tab - Improved layout of error data with historic errors
> Diagnostic Tab - A summary screen for better drive health statistics.
> The Display tab to show energy consumed by the drive in hourly, daily, monthly and yearly basis.
> The Display tab - Display drive & motor parameters monitoring in graphical widgets
> Display tab - Data logging for loading logged in the device.
> New motor control Panel to test the motor running conditions. .
> Field bus manuals for option boards can be opened from My Device tab.
> New Print feature to select printable data like Option board parameters etc.
> Save/Restore configuration from the drive through the device menu.
> Autotune the device for the motor with Erase options.
> Support of only English is available in the first version of this software .
3. System Requirement
Equipment Minimum
Equipment Recommended
> Sometimes parameter values cannot be edited in parameter grid inside parameter list tab .Use F2 key to edit
parameter values.
> Local Stop Message will not be displayed,if Local Stop button is pressed momentarily or quickly.The button has to be
pressed firmly for 4-5 Sec.
> Visibility or disabling of a parameter depending on other parameter(s) are not managed at the moment in the
parameter grid.
> We observed that for some drive references, the CLI (Current Limitation) parameter does not reset after a factory
setting.
> Software does not respond after you try to select all parameters in the parameter tab using Ctrl + A.
> Import of configuration stored in the Keypad HMI from SoMove homepage is not yet available.
5. Container Supported
> SoMove V2.7.5 and earlier
> While performing store to device using Modbus TCP with multi config feature, increase Global Time out to 5000ms in
the SoMove container Modbus TCP scan - advanced settings.
> While modifying the topology with MultiConfiguration configured, only Device Reference change is supported.
Firmare Version and Option Card changes are not supported.
> Help feature is not available in this version. It will be updated in the next version once finalized from Technical
Publication team.
> If the drive is configured with multi configuration, drive configuration has to be saved in the DTM for configurations
1,2,and 3 before downloading to the drive.
> Multiconfiguration feature with Input and Output Assignments of the Option card is not supported.
> Current version of the DTM has connection issues with Pactware V5.0
> Connection Interruption in SoMachine FDT Container if there are multiple instances of DTM
> Synchronization issues may occur while transferring a project to a protected device in SoMachine
> Creating Topology for more than 8 DTM instances leads to exception in SoMachine
> Continuous opening and closing of device view screen leads to disfigured display .