Monday, November 18, 2019, 01:17 PM: Page 1 of 13 C:/Users/JEPS T/Desktop/CAVITE 2/STAAD - REPORT/CAVITE 2.anl
Monday, November 18, 2019, 01:17 PM: Page 1 of 13 C:/Users/JEPS T/Desktop/CAVITE 2/STAAD - REPORT/CAVITE 2.anl
Monday, November 18, 2019, 01:17 PM: Page 1 of 13 C:/Users/JEPS T/Desktop/CAVITE 2/STAAD - REPORT/CAVITE 2.anl
PAGE NO. 1
****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 22.00.00.15 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= NOV 14, 2019 *
* Time= 19:34:54 *
* *
* Licensed to: only @ ::LAVTeam:: (R) *
****************************************************
1. STAAD SPACE
INPUT FILE: C:\Users\JEPST~1\Desktop\CAVITE~1\STAAD-~1\CAVITE 2.STD
2. START JOB INFORMATION
3. ENGINEER DATE 14-NOV-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 2.85 0 0; 3 5.7 0 0; 4 0 0 3; 5 2.85 0 3; 6 5.7 0 3; 7 0 0 7
9. 8 2.85 0 7; 9 5.7 0 7; 10 0 0 10; 11 2.85 0 10; 12 5.7 0 10; 13 0 1.3 0
10. 14 2.85 1.3 0; 15 5.7 1.3 0; 16 0 1.3 3; 17 2.85 1.3 3; 18 5.7 1.3 3
11. 19 0 1.3 7; 20 2.85 1.3 7; 21 5.7 1.3 7; 22 0 1.3 10; 23 2.85 1.3 10
12. 24 5.7 1.3 10; 25 0 4.475 0; 26 2.85 4.475 0; 27 5.7 4.475 0; 28 0 4.475 3
13. 29 2.85 4.475 3; 30 5.7 4.475 3; 31 0 4.475 7; 32 2.85 4.475 7; 33 5.7 4.475 7
14. 35 2.85 4.475 10; 36 5.7 4.475 10; 37 1.35 4.475 0; 38 1.35 4.475 3
15. 39 2.85 4.475 5.775; 40 5.7 4.475 5.775; 41 2.85 7.075 0; 42 5.7 7.075 0
16. 43 2.85 7.075 3; 44 5.7 7.075 3; 47 4.58 4.475 3.84; 48 5.7 4.475 3.84
17. 49 4.58 4.475 5.775; 50 4.58 4.475 3
18. MEMBER INCIDENCES
19. 1 1 13; 2 2 14; 3 3 15; 4 4 16; 5 5 17; 6 6 18; 7 7 19; 8 8 20; 9 9 21
20. 10 10 22; 11 11 23; 12 12 24; 13 13 14; 14 14 15; 15 16 17; 16 17 18; 17 19 20
21. 18 20 21; 19 22 23; 20 23 24; 21 13 16; 22 16 19; 23 19 22; 24 14 17; 25 17 20
22. 26 20 23; 27 15 18; 28 18 21; 29 21 24; 30 13 25; 31 14 26; 32 15 27; 33 16 28
23. 34 17 29; 35 18 30; 36 19 31; 37 20 32; 38 21 33; 40 23 35; 41 24 36; 42 25 37
24. 43 26 27; 44 28 38; 45 29 50; 46 31 32; 47 32 33; 49 35 36; 50 25 28; 51 28 31
25. 53 26 29; 54 29 39; 55 32 35; 56 27 30; 57 30 48; 58 33 36; 59 37 26; 60 38 29
26. 61 37 38; 62 39 32; 63 40 33; 64 39 49; 65 26 41; 66 27 42; 67 29 43; 68 30 44
27. 69 41 42; 70 43 44; 71 41 43; 72 42 44; 76 48 40; 77 47 48; 78 49 40; 80 50 30
28. 81 50 47; 82 47 49
29. START GROUP DEFINITION
30. FLOOR
31. _FLOOR1 13 TO 29
32. _FLOOR2 42 TO 47 49 TO 51 53 TO 64 76 TO 78 80 TO 82
33. JOINT
34. END GROUP DEFINITION
35. DEFINE MATERIAL START
36. ISOTROPIC CONCRETE
37. E 2.17185E+007
38. POISSON 0.17
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
************************************************************************************
NO. TYPE FL. LEVEL FL. WT CENTRE OF MASS MASTER JOINT NO.
X Z
************************************************************************************
77. R1 1.0
78. CHECK SOFT STORY ASCE7
79. *EARTHQUAKE LOAD
80. LOAD 1 LOADTYPE SEISMIC TITLE EX
81. UBC LOAD X 1 DEC 1 ACC 0.05
82. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
1 1.30 OK OK
2 4.47 OK OK
***********************************************************
* *
* X DIRECTION : Ta = 0.317 Tb = 0.261 Tuser = 0.000 *
* T = 0.261, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 1236.97 = 160.08 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
83. CHANGE
84. LOAD 2 LOADTYPE SEISMIC TITLE EZ
85. UBC LOAD Z 1 DEC 1 ACC 0.05
86. PERFORM ANALYSIS
***********************************************************
* *
* Z DIRECTION : Ta = 0.317 Tb = 0.255 Tuser = 0.000 *
* T = 0.255, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 1236.97 = 160.08 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
87. CHANGE
88. LOAD 3 LOADTYPE DEAD TITLE DL
89. REFERENCE LOAD
90. R1 -1.0
91. LOAD 4 LOADTYPE DEAD TITLE LL
92. FLOOR LOAD
93. _FLOOR2 FLOAD -1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
************************************************************
************************************************************
163. CHANGE
164. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2017 Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************