INSTALLATION GUIDE
4.02.0250.20010 2.7 en-US ENGLISH
Important User Information
Disclaimer
The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any
inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability
for any errors that may appear in this document.
HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product
development. The information in this document shall therefore not be construed as a commitment on the part of
HMS Industrial Networks and is subject to change without notice. HMS Industrial Networks makes no commitment
to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are only
intended to help improve understanding of the functionality and handling of the product. In view of the wide range
of possible applications of the product, and because of the many variables and requirements associated with any
particular implementation, HMS Industrial Networks cannot assume responsibility or liability for actual use based on
the data, examples or illustrations included in this document nor for any damages incurred during installation of the
product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the
product is used correctly in their specific application and that the application meets all performance and safety
requirements including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will
under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of
undocumented features or functional side effects found outside the documented scope of the product. The effects
caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility
issues and stability issues.
2 Features ............................................................................................................................... 5
6 Troubleshooting ................................................................................................................ 15
6.1 Interface Installation: Driver Not Found ............................................................................. 15
8 Support .............................................................................................................................. 16
1 User Guide
Please read the manual carefully. Make sure you fully understand the manual before using the
product.
1.4 Conventions
Instructions and results are structured as follows:
► instruction 1
► instruction 2
→ result 1
→ result 2
Lists are structured as follows:
• item 1
• item 2
Bold typeface indicates interactive parts such as connectors and switches on the hardware, or
menus and buttons in a graphical user interface.
This font is used to indicate program code and other
kinds of data input/output such as configuration scripts.
This instruction must be followed to avoid a risk of reduced functionality and/or damage
to the equipment, or to avoid a network security risk.
2 Features
The VCI is an universal driver for all Ixxat-Interfaces and already included in the scope of delivery
of the interface. As a DLL for Windows XP/7/8/10 the VCI forms the interface between the user
application and the various Ixxat-Interfaces. A special feature is its uniform programming
interface, which allows a change between various interface types without adapting the user
software.
The VCI supports all current Ixxat-Interfaces. Information about supported interfaces and version
of the VCI driver is available within the support area on www.ixxat.com.
This installation guide applies for various VCI driver software versions. When the VCI driver is
installed, the names of the automatically installed folders and files correspond to the software
version in use. In the following sections the names are referred to the VCI software version 4. If
software version 3 is installed the names differ corresponding to the version number.
Make sure that the old version is uninstalled before updating to the newer version.
With VCI V 3 two lists are shown: Available Devices and Running Devices.
The name of the device is displayed in the VCI Device Server Control.
► Enter IP of device in use in field IP/URL (to set IP address of CAN@net NT see User Manual
CAN@net NT).
► Adjust special settings if necessary.
Special settings
Setting Enabled Disabled
Logging Debugging information is stored during usage of the Debugging information is not
device. Necessary if HMS Industrial Networks stored.
support needs logging files.
With the CAN@net NT TCP/IP connection monitoring is activated. The VCI Device Server cyclically checks
if the connection between computer and device is still established. A connection breakdown is recognized
after approximately 15-20 seconds. The device is then removed from VCI and the reestablishment of the
connection is attempted. When the device is successfully found it is announced to VCI and is available for
VCI applications. After reconnecting CAN controller and filter settings are lost. The interface must be
started and initialized again in the application.
1 NT
2
3
4
5
With VCI V 3 the devices are displayed in two lists: Available Devices and Running Devices (instead of
the symbols in VCI V4).
► Select the device in list (1) and click button Start (2).
→ Device is announced to VCI (indicated by green symbol ).
→ When the device is ready to use with the VCI application, symbol is shown.
To test if the connection succeeded, start canAnalyser Mini. All started devices are shown in the list of
available CAN channels.
► To stop a running device select the device in the list and click button Stop (3).
→ Selected device is ready to edit or remove.
► To configure an existing device select the device in the list and click button Edit (4).
To remove an existing device:
► Select the device in the list.
► Click button Remove (5).
► Confirm security message with Yes.
VCI Device Server Control is only used for configuring VCI devices. Announcement and removal is done by
Ixxat VCI V4 Device Server Service. Devices are controlled by INI-files stored in folder Documents and
Settings/Application Data/Ixxat/VCI/4.x. For more information read Readme.txt in folder Program Files/
HMS/Ixxat VCI 4.0/Device Server.
With VCI V 3 two lists are shown: Available Devices and Running Devices.
The name of the device is displayed in the VCI Device Server Control.
► Make sure that CAN@net II and network interface are located in the same IP address
domain (IP and subnet), e.g. PC Ethernet port 192.168.1.55 / CAN@net 192.168.1.xxx.
Edit settings:
► In field IP/URL enter IP-address of CAN@net II.
► In field Password enter password. The preset password is IXXAT.
► In field Confirm Passw. enter password again.
► Adjust special settings if necessary.
Special settings
Setting Enabled Disabled
Download Firmware Firmware of the device is downloaded on the Useful when using slow connections.
device on every start. Firmware has to be flashed permanently
on the device with flash programming
software (see support area on www.ixxat.
com).
Logging Debugging information is stored during usage of Debugging information is not stored.
the device. Necessary if HMS Industrial
Networks support needs logging files.
Disconnect Detection Enables TCP/IP connection monitoring. Cyclically
checks if the connection between computer and
device is still established.
A connection breakdown is recognized after
approximately 15-20 seconds. The device is then
removed from VCI and the reestablishment of
the connection is attempted. When the device is
successfully found it is announced to VCI and is
available for VCI applications. CAN controller
and filter settings are lost.
1 2
3
4
5
With VCI V 3 the devices are displayed in two lists: Available Devices and Running Devices (instead of
the symbols in VCI V4).
► Select the device in list (1) and click button Start (2).
→ Device is announced to VCI (indicated by green symbol ).
→ When the device is ready to use with the VCI application, symbol is shown.
To test if the connection succeeded, start canAnalyser Mini. All started devices are shown in the list of
available CAN channels.
► To stop a running device select the device in the list and click button Stop (3).
→ Selected device is ready to edit or remove.
► To configure an existing device select the device in the list and click button Edit (4).
To remove an existing device:
► Select the device in the list.
► Click button Remove (5).
► Confirm security message with Yes.
VCI Device Server Control is only used for configuring VCI devices. Announcement and removal is done by
Ixxat VCI V4 Device Server Service. Devices are controlled by INI-files stored in folder Documents and
Settings/Application Data/Ixxat/VCI/4.x. For more information read Readme.txt in folder Program Files/
HMS/Ixxat VCI 4.0/Device Server.
The Bluetooth® connection can only be established if VCI Device Server Control is
executed with administrator rights (although there is no visible difference when starting
as normal user).
With VCI V 3 two lists are shown: Available Devices and Running Devices.
The name of the device is displayed in the VCI Device Server Control.
Further settings
► Adjust special settings if necessary.
Special settings
Setting Enabled Disabled
Logging Debugging information is stored during usage of the Debugging information is not
device. Necessary if HMS Industrial Networks support stored.
needs logging files.
Disconnect Detection Enables Bluetooth connection monitoring. Cyclically
checks if the connection between computer and device
is still established.
A connection breakdown is recognized after
approximately 30-40 seconds. The device is then
removed from VCI and the reestablishment of the
connection is attempted. When the device is
successfully found it is announced to VCI and is available
for VCI applications. CAN controller and filter settings
are lost.
2
1
3
4
5
With VCI V 3 the devices are displayed in two lists: Available Devices and Running Devices (instead of
the symbols in VCI V4).
► Select the device in list (1) and click button Start (2).
→ Device is announced to VCI (indicated by green symbol ).
→ When the device is ready to use with the VCI application, symbol is shown.
To test if the connection succeeded, start canAnalyser Mini. All started devices are shown in the list of
available CAN channels.
► To stop a running device select the device in the list and click button Stop (3).
→ Selected device is ready to edit or remove.
► To configure an existing device select the device in the list and click button Edit (4).
To remove an existing device:
► Select the device in the list.
► Click button Remove (5).
► Confirm security message with Yes.
VCI Device Server Control is only used for configuring VCI devices. Announcement and removal is done by
Ixxat VCI V4 Device Server Service. Devices are controlled by INI-files stored in folder Documents and
Settings/Application Data/Ixxat/VCI/4.x. For more information read Readme.txt in folder Program Files/
HMS/Ixxat VCI 4.0/Device Server.
6 Troubleshooting
6.1 Interface Installation: Driver Not Found
Possible cause of failure:
• Hardware was installed before VCI installation
• INF files of driver CD were installed via right-hand mouse button
For the hardware installation the location of the relevant INF file is required. INF files are not
available in unpacked form and must be installed via the hardware wizard.
Remedial actions:
► Abort the hardware wizard.
► Install the VCI Driver.
► Restart Windows.
→ Hardware is automatically detected.
→ Hardware-wizard starts automatically.
VCI V2 and V4
The parallel usage of VCI V2.20 and VCI V4 is not possible. For information about the support of
VCI V2.20 by VCI V4 see www.ixxat.com/support.
VCI V3 and V4
The parallel usage of one interface with VCI V3 and one with VCI V4 is not possible.
8 Support
Observe the following information in the support area on www.ixxat.com/support:
• information about products
• FAQ lists
• installation notes
• updated product versions
• release notes