ZT 111
ZT 111
ZT 111
Introduction..........................................................1
Safety Information................................................1
Instrument Overview............................................3
LCD Display...................................................3
Function Buttons............................................5
Rotary Switch.................................................7
Input Terminals..............................................9
Measurements Instruction..................................10
Measure AC/DC Voltage..............................10
Measure AC/DC Current..............................10
Measure Resistance.....................................11
Test for Continuity........................................12
Test Diodes..................................................12
Measure Capacitance..................................13
Measure Frequency.....................................14
Measure Duty Cycle.....................................15
Measure Temperature...................................15
Test NCV………………………………………16
Safety Information
To avoid possible electrical shock, fire, or
personal injury, please read all safety information
before you use the product. Please use the
product only as specified, or the protection
supplied by the product can be compromised.
• Examine the case before you use the product.
Look for cracks or missing plastic. Carefully look
at the insulation around the terminals.
• The measurement must be made with correct
input terminals and functions and within the
allowable measuring range.
• Do not use the product around explosive gas,
vapor, or in damp or wet environments.
1
Downloaded from www.Manualslib.com manuals search engine
• Keep fingers behind the finger guards on the
probes.
• When the product has already been connected
to the line being measured, do NOT touch the
input terminal that is not in service.
• Disconnect the test leads from the circuit before
changing the mode.
• When the voltage to be measured exceeds 36V
DC or 25V AC, the operator shall be careful
enough to avoid electric shock.
• Misuse of mode or range can lead to hazards,
be cautious. “ ” will be shown on the display
when the input is out of range.
• Low level of a battery will result in incorrect
readings. Change the batteries when battery
level is low. Do not make measurements when
the battery door is not properly placed.
2
Downloaded from www.Manualslib.com manuals search engine
Instrument Overview
LCD Display
② ③ ④ ⑤ ⑥ ⑦
① ⑧
⑱
⑰
⑯
⑮ ⑨
⑭
⑬ ⑫ ⑪ ⑩
① Continuity test.
Temperature test.
②
(Fahrenheit or Celsius)
③ Diode test.
④ Duty cycle test.
⑤ Display freezes present reading.
⑥ Resistance test. (Ohm)
3
Downloaded from www.Manualslib.com manuals search engine
⑦ Frequency test. (Hertz)
⑧ Capacitance test. (Farad)
⑨ Voltage test. (Volt)
⑩ Current test. (Ampere)
Manual range. The user selects
⑪
the range.
Auto range. The product selects
⑫
the range with the best resolution.
The product measures both
⑬ sinusoidal and nonsinusoidal ac
waveforms accurately.
⑭ Low battery. Replace batteries.
⑮ Alternating current.
⑯ Direct current.
⑰ Negative readings.
⑱ Unsafe Voltage.
Measurement units.
4
Downloaded from www.Manualslib.com manuals search engine
Function Buttons
① ②
Range/Backlight Button
• Push this button once to enter the manual
range mode. In manual range mode,
each push increases the range; when the
highest range is reached, the next push
will lead to the lowest range. To exit the
①
manual range mode, turn the rotary
switch.
• Push for more than 2 seconds to turn on
the backlight; long-push again to turn off
or the backlight automatically turns off
after 2 minutes.
5
Downloaded from www.Manualslib.com manuals search engine
SEL/HOLD Button
• Push to select alternate measurement
modes on a rotary switch setting,
including:
1. DC V/AC V/Frequency/Duty Cycle
2. DC mV/AC mV/Temperature
3. Resistance/ Continuity/ Diode/
② Capacitance
4. Frequency/Duty Cycle
5. DC A/AC A
6. DC μA/AC μA
7. NCV
• Push for more than 2 seconds to hold the
current reading on the display; long-push
again to continue normal operation.
6
Downloaded from www.Manualslib.com manuals search engine
Rotary Switch
7
Downloaded from www.Manualslib.com manuals search engine
DC voltage ≤999.9V
AC voltage ≤750V
Frequency with high voltage
Duty Cycle from 1%~99%
DC voltage ≤99.99mV
AC voltage ≤99.99mV
Celsius: -20~1000
Fahrenheit: -4~1832
Ohms ≤99.99MΩ
Continuity. Beeper turns on at <50Ω
Diode test. Displays above 3V
Farads ≤9.999mF
Frequency with low voltage
Duty Cycle from 1%~99%
DC A ≤9.999A
AC A ≤9.999A
DC A ≤999.9μA
AC A ≤999.9μA
8
Downloaded from www.Manualslib.com manuals search engine
Input Terminals
9
Downloaded from www.Manualslib.com manuals search engine
Measurements Instruction
Measure AC/DC Voltage
1. Connect the black test lead to the COM
Terminal and the red lead to the VΩHz
Terminal.
2. Turn the rotary switch to or to .
3. Press SEL to toggle between AC/DC.
4. Touch the probes to the correct test points of
the circuit to measure the voltage.
5. Read the measured voltage on the display.
*Do not measure voltage that exceeds the extremes
as indicated in the Specifications.
*Do not touch high voltage circuit during
measurements.
10
Downloaded from www.Manualslib.com manuals search engine
2. Turn the rotary switch to or .
3. Press SEL to toggle between AC/DC.
4. Break the circuit path to be measured, connect
the test leads across the break and apply
power.
5. Read the measured current on the display.
*Do not measure current that exceeds the extremes
as indicated in the Specifications.
*Use the A mA Terminal and the Mode when
you are measuring an unknown current. Then
switch to the VΩHz Terminal and the Mode if
necessary.
*Do not input voltage at this setting.
Measure Resistance
1. Connect the black test lead to the COM
Terminal and the test lead to the VΩHz
Terminal.
2. Turn the rotary switch to , and the display
will show “ ”.
3. Touch the probes to the desired test points of
the circuit to measure the resistance.
4. Read the measured resistance on the display.
11
Downloaded from www.Manualslib.com manuals search engine
*Disconnect circuit power and discharge all
capacitors before you test resistance.
*Do not input voltage at this setting.
Test Diodes
1. Connect the black test lead to the COM
Terminal and the red lead to the VΩHz
Terminal.
12
Downloaded from www.Manualslib.com manuals search engine
2. Turn the rotary switch to , press SEL twice
to toggle to the Diode Mode.
3. Connect the red probe to the anode side and
the black probe to the cathode side of the
diode being tested.
4. Read the forward bias voltage value on the
display.
5. If the polarity of the test leads is reversed with
diode polarity or the diode is broken, the
display reading shows “ ”.
*Do not input voltage at this setting.
*Disconnect circuit power and discharge all
capacitors before you test diode.
Measure Capacitance
1. Connect the black test lead to the COM
Terminal and the red lead to the VΩHz
Terminal.
2. Turn the rotary switch to , press SEL three
times to toggle to the Capacitance Mode.
13
Downloaded from www.Manualslib.com manuals search engine
3. Connect the red probe to the anode side and
the black probe to the cathode side of the
capacitor being tested.
4. Read the measured capacitance value on the
display once the reading is stablized.
*Disconnect circuit power and discharge all
capacitors before you test capacitance.
Measure Frequency
1. Connect the black test lead to the COM
Terminal and the red lead to the VΩHz
Terminal.
2. Turn the rotary switch to (applies to low
frequency with high voltage), press SEL twice
to toggle to the Frequency Mode; or turn the
rotary switch to (applies to high frequency
with low voltage).
3. Touch the probes to the desired test points.
4. Read the measured frequency value on the
display.
14
Downloaded from www.Manualslib.com manuals search engine
Measure Duty Cycle
1. Connect the black test lead to the COM
Terminal and the red lead to the VΩHz
Terminal.
2. Turn the rotary switch to (applies to low
frequency with high voltage), press SEL three
times to toggle to the Duty Cycle Mode; or turn
the rotary switch to (applies to high
frequency with low voltage), press SEL once to
toggle to the Duty Cycle Mode.
3. Touch the probes to the desired test points.
4. Read the measured duty cycle value on the
display.
Measure Temperature
1. Connect the black thermocouple probe to the
COM Terminal and the red probe to the VΩHz
Terminal.
15
Downloaded from www.Manualslib.com manuals search engine
2. Turn the rotary switch to , press SEL three
times to measure temperature(℃), or press
SEL four times to measure temperature(℉).
3. Touch the probes to the desired test points.
4. Read the measured temperature on the
display.
*Do not input voltage at this setting.
Test NCV
1. Turn the rotary switch to .
2. Hold the product and move it around, the built-
in beeper will beep when the inner sensor
detects AC voltage nearby. The stronger the
voltage is, the quicker the beeper beeps.
16
Downloaded from www.Manualslib.com manuals search engine
Maintenance
Beyond replacing batteries and fuses, do not
attempt to repair or service the product unless you
are qualified to do so and have the relevant
calibration, performance test, and service
instructions.
17
Downloaded from www.Manualslib.com manuals search engine
2. Loosen the screw on the battery door and
remove the battery door.
3. Replace the used batteries with new batteries
of the same type.
4. Place the battery door back and fasten the
screw.
18
Downloaded from www.Manualslib.com manuals search engine
Specifications
General Specifications
Display(LCD) 9999 Counts
Ranging Auto/Manual
Material ABS
Update Rate 3 Times/Second
Ture RMS √
Data Hold √
Backlight √
Low Battery Indication √
Auto Power Off √
Mechanical Specifications
Dimension 130*65*32mm
Weight 114g
Battery Type 1.5V AAA Battery * 2
Warranty One year
Environmental Specifications
Temperature 0~40℃
Operating
Humidity <75%
Temperature -20~60℃
Storage
Humidity <80%
19
Downloaded from www.Manualslib.com manuals search engine
Electrical Specifications
20
Downloaded from www.Manualslib.com manuals search engine
Function Range Resolution Accuracy
21
Downloaded from www.Manualslib.com manuals search engine
Function Range Resolution Accuracy
9.999nF 0.001nF ±(5.0%+20)
99.99nF 0.01nF
999.9nF 0.1nF
Capacitance 9.999μF 0.001μF ±(2.0%+5)
99.99μF 0.01μF
999.9μF 0.1μF
9.999mF 0.001mF ±(5.0%+5)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
Frequency ±(0.1%+2)
99.99kHz 0.01kHz
999.9kHz 0.1kHz
9.999MHz 0.001MHz
Duty Cycle 1%~99% 0.1% ±(0.1%+2)
22
Downloaded from www.Manualslib.com manuals search engine
Function Range Resolution Accuracy
(-20~1000)℃ 1℃
Temperature ±(2.5%+5)
(-4~1832)℉ 1℉
Diode √
Continuity √
NCV √
23
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine