LTHE
LTHE
LTHE
TUV Control No.: TUV SAP No: Branch: NOIDA Report No: LTHE-
8116916039 FCHCU -52414-IR-16
OWNER: HPCL Inspection Notification HPCL-HCUV/NOI/3522 R0
Number(s) Dt. 01.11.19
Vendor Name M/s Dee development limited Client’s PO No.(on vendor) REFINERY/75000-52414/PAS
Dt. 17.11.18
Sub Vendor Name: Vendor’s PO No. on sub
(if applicable) : vendor
Stage of inspection:
Kick-off / Pre-inspection meeting Material Identification Interim stage
Sr. No P. O. item no. SAP CODE Item Description PO Quantity Quantity Quantity Remarks
(Unit) offered Accepted
Reference Documents:
Sr. No LTHE Document LTHE document no. Approver Approval Status Date
Title (Specify the details)
2 Specification B016-HCUV-LT-503-PP-SP-
EIL CODE 1 17-05-18
0002 REV 2
Disclaimer: This issue of inspection report does not relieve the Supplier / Manufacturer from their responsibility towards the Client to supply t he item(s) concerned in
Full compliance with requirements of its order specification.
2) ITP Clause No.11(a)- Thickness checked @ 10% by thickness gauge at elbow bends portion (05 points) and found to meet the
requirement.
3) ITP Clause No.11(b) -Visually checked for Surface finishes and found no injurious defect.
4) ITP Clause No.11(c)- Dimensional checked @ 10% randomly, found to meet the specification requirement.
5) ITP Clause No.11(d)- DPT witnessed @10 % on bevel edge on SS material and found no relevant indications.
6) ITP Clause No.11(e)-PMI witnessed @ 20% on SS material & and found to meet the requirement.
8) ITP Clause No. 11(g)-Marking of the item verified randomly and found as per requirement.
2) Dimension, PMI, Chemical & NDT reports reviewed and found in order.
3) Ferrite content on weld deposit report reviewed & found as per requirement.
Disclaimer: This issue of inspection report does not relieve the Supplier / Manufacturer from their responsibility towards the Client to supply the item(s) concerned in
Full compliance with requirements of its order specification.
Areas of concern : -
Disclaimer: This issue of inspection report does not relieve the Supplier / Manufacturer from their responsibility towards the Client to supply the item(s) concerned in
Full compliance with requirements of its order specification.
Disclaimer: This issue of inspection report does not relieve the Supplier / Manufacturer from their responsibility towards the Client to supply the item(s) concerned in
Full compliance with requirements of its order specification.
Disclaimer: This issue of inspection report does not relieve the Supplier / Manufacturer from their responsibility towards the Client to supply the item(s) concerned in
Full compliance with requirements of its order specification.