Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

KEIM Porosil-Leichtputz (Lightweight Render)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Data Sheet

KEIM Porosil®-Leichtputz
(Lightweight render)

1. Product description Base render


The minimum thickness as base render is 10 mm. In
Mineral light-weight mortar manufactured to DIN EN case of layer thicknesses over 20 mm a multilayer
998-1, based on lime, cement, lime sandstone and application is required: strictly follow a sufficient setting
mineral light-weight aggregates, complies with mortar time of the previous layer (1 day per mm render
category CS II, P II to DIN V 18 550. KEIM Porosil- thickness). The previous layer has to be always
Leichtputz is water-repellent. roughened thoroughly.
On aerated concrete stones the base coat has to be
applied in 2 layers wet-on-wet (setting time of the first
2. Field of application layer max. 1-2 hours, total thickness approx. 15 mm).
This way avoids a too intensive dehydration by the
KEIM Porosil-Leichtputz is used as topcoat and base substrate, as the first layer reduces the water absorption.
coat render for interior and exterior applications, With this procedure a sealing primer or prewetting is
especially on highly heat-insulating wall-building unnecessary.
material
Reinforcing render
Fabric embedding rendering method with KEIM
3. Product properties Universalputz as intermediate or top render is required
for masonry with light-weight bricks with λ-values of
• Grain size: 0 – 1.3 mm 0.14 W/mK and less.
• Bulk density: 1.1 g/ cm³
• Colour shade: grey Top render
The layer thickness of the top render depends on the
Material characteristics to DIN EN 998-1 desired rendering method. Do not drop below a
• Compressive strength: minimum thickness of 3 mm. The setting time of the base
after 28 days 1.5–5.0 N/mm², CS II render has to be observed! (1 day per mm render
• Flammability: A1 thickness).
• Water vapour
permeability µ: approx. 12 KEIM Porosil-Leichtputz is suitable for all conventional
• Water absorption: W2 rendering machines. For manual application KEIM
(water-repellent acc. to DIN V 18 550) Porosil-Leichtputz can be mixed with a blunger. When
• Tensile bond strength: ≥ 0.08 N/mm² applying by machine, the render is to be treated with a
(fracture pattern A, B, C) trowel immediately after spraying.
• Thermal conductivity:
λ10,dry : ≤ 0.39 W/(mK) for P = 50%* Application conditions
≤ 0.43 W/(mK) for P = 90%* Air and surface temperature: > 5°C. Do not apply
(*tabular values to EN 1745) under direct sun or on sun-heated substrates In case of
a thin layer application or excessively fast drying
process (e.g strong wind), the finished render surface
4. Application instructions has to be remoistened once or more times.

Substrate preparation Consumption


The substrate must be solid, sound and free from dust Approx. 1 kg per m² per mm thickness.
and dirt. Base coat renders have to be properly set.
Strongly absorbent substrates have to be prewettened. Subsequent coating
Smooth surfaces need a suitable bridging coat, e.g. KEIM Porosil-Leichtputz can be overcoated with KEIM
KEIM Universalputz. mineral coating system, e.g. KEIM Soldalit or KEIM
Granital, after a proper setting time (at least 10 days).
Application A pretreatment with KEIM Ätzflüssigkeit, diluted 1:3
Stand 3/15

Water requirement for KEIM Porosil-Leichtputz approx. with water, is recommended.


8 - 8.5 l for one sack of 25 kg = 25 l wet mortar.
TD KEIM Porosil®-Leichtputz

5. Packaging

25 kg bags

6. Storage

12 months, stored under dry conditions.

7. Disposal

EC Waste Code No. 17 01 01


Any residues must be emptied out of containers before
recycling.

8. Safety instructions

GISBAU Product Code/GISCODE: ZP 1

Provide appropriate protection for surfaces which are


not to be treated (e.g. glass, natural stone, ceramics
etc.). Any splashes on surrounding surfaces or traffic
areas must be rinsed off immediately with plenty of
water. Protect the eyes and skin from splashes. Keep
out of reach of children.

Low chromate content according to TRGS 613.

Please refer to EC Safety Data Sheet.

The stated values and properties are the result of extensive development work
and practical experience. Our recommendations for application, whether given
verbally or in writing, are intended to provide assistance in the selection of our
products and do not establish a contractual relationship. In particular, they do not
release those purchasing and applying our products from the duty of
establishing for themselves, with due care, the suitability of our products for the
intended application. Standard building industry practices must be complied
with. We retain the right to make modifications to improve the products or their
application. This edition supersedes all earlier editions.
Stand 03/15

KEIMFARBEN
Keimstraße 16 Frederik-Ipsen-Straße 6 www.keimfarben.de
D-86420 Diedorf 15926 Luckau info@keimfarben.de
Tel. +49 (821) 4802-0 Tel. +49 (35456) 676-0
GmbH Fax +49 (821) 4802-210 Fax +49 (35456) 676-38