weeken
Weekly circulation, it is possible to set 6 periods called events each day with
different temperatures, also you can select "manual mode" or "temporary
control mode" according to your individual requirements. The thermostat is 2 23:00 15℃
recommended for the control of electric heating devices or on/off valve actuator
used in water-based heating systems.
Advanced setting (qualified person preferred)
Selection Table: When the thermostat is turned off, You can press" " and turn on it at the same
Model Current Application time ,then you can enter the mode of advanced setting.
Symbol Setting or
Built-in & floor sensor, floor limit sensor, period 1 ADJ Temperature Adjust measured temperature
M6.713 3A
programming calibration
Built-in & floor sensor, floor limit sensor, period 2 SEN Sensor mode IN: built-in sensor
M6.723 3A OUT: floor sensor
programming,a potential- free output ALL: both sensors
Built-in & floor sensor, floor limit sensor, period 3. LIT Limitation Adjust limitation value,
M6.716 16A temperature Limitation range:5℃~60℃
programming
4 DIF Switching Adjust switching differential
M6.703 3A A pair of contacts for potential- free output differential
5 LTP Antifreeze Turn on/off Anti-frozen
function function
6 PRG Set vacation 00: 5/2 day mode
Technical data: mode 01: 6/1 day mode
Voltage : AC230V (AC110V/AC24V available) 02: 7 day mode
Power consumption : 2W 7 RLE Potential- free Change the present
Setting range : 5℃~90℃ output and main linkage way
Limitation range : 5℃~99℃ (factory setting: 35℃) power output in
Switching differential :0.5℃~10℃ (factory setting: ±1℃) the
Ambient temperature : -5℃~50℃ same/different
Protective housing : IP20 way
Housing material : self-extinguishing PC 8 DLY Delay time of Change linkage delay time
Potential- free
output
Daily use of the thermostat 9 HIT Max temperature Limitation temperature
1) on/off " " setpoint
2) In the manual mode,press " " or" "to make temporary control。 AFAC Reset to factory Press" "and hold for 5s,all
3) Press" " or" " to increase or decrease pre-set temperature. settings parameters will be reset
4) Press" " and" "and hold for 5 seconds at the same time to adjust Sensor failure:
time. Press " " to choose object to adjust; Press" " or" " to Please select the right sensor mode when operation, it will display the
"Err" symbol on screen far sensor failure, thermostat must be checked till
increase or decrease your set values; Press " " to confirm and exit.
the fault is eliminated
5) Press the " " key to select manual mode or clock-controlled program
mode.
6) It displays the time or the pre-set temperature alternately, and it displays Explanation of symbols:
the measured temperature directly.
7) When you press " " and" "at the same time and hold for 5 seconds,
the thermostat will be locked/unlocked. When it is locked, no operation Manual mode Period mode
can be carried out until it is unlocked. Six period
Antifreeze
temperature
:
Display symbols: Time
Period programming 43
86 13
Press " " and hold for 5s to enter the mode of Period programming.
1 06:00 20℃
start/end time
Set programmed
2 08:00 15℃
temperature
weekday
3 11:30 15℃
Set
4 12:30 15℃
5 17:00 22℃
the
6 22:00 15℃
Connection diagram
M6.713 1 2 3 4 5 6 7
M6.716 1 2 3 4 5 6 7
X
L N L1 N1 Sensor
AC230V 16A
M6.723
M6.703 1 2 3 4 5 6 7
L N COM NO NC Sensor
AC230V 3A
Advanced Settings
Extreme care MUST be taken when adjusting the technical parameters found within the advanced settings. Operation of
these functions should only be undertaken by competent people and the following details should be read carefully.
To enter advanced settings turn the thermostat off, then hold the key down and press simultaneously.
Thermostat Installation
Make electrical connections to the thermostat (see
below.) Mount the thermostat back onto the
backing plate & replace the frame.