Time switch

AlphaRex3 D21 - 1-channel


4 126 31 / 32 / 33 - 047 61 / 63 / 6047 60 ®

! Safety notes
This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation and
use can lead to risk of electric shock or fire. Before carrying out the installation read the instructions and take account of
the product’s specific mounting location. Do not open up, dismantle, alter or modify the device except where specifical-
ly required to do so by the instructions. All Legrand products must be opened and repaired exclusively by personnel trained
and approved by Legrand. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement
and guarantees. Use only Legrand brand accessories.

292555/03
The device contains a LiMnO2 primary cell. When the product reaches the end of its life, this cell must be correctly removed and
disposed of in accordance with national legislation and the requirements of environmental protection.
Technical data
4126 31 4126 32 4126 33
047 61 6047 60 047 63
Supply voltage: 230V 50/60Hz 120V 50/60Hz 24V AC/DC
Effective power consumption: Approx. 1 W
Contact rating: 1 changeover contact 16A 250V~µ cos ϕ = 1
Parallel compensation: 600W max. 70µF
Accuracy: ~ 0,1 s / day
single strand multi strand
max. 1,4 Nm
Terminal capacity:
1,5...4 mm
2
1,5...2,5 mm2
Programmes : 56
Battery reserve: 5 years
Storage ambient: -20°C to +60°C
Working ambient: -20°C to +55°C
IP: 20

General information
• Start-up: after applying the supply voltage, the time switch
starts automatically with the last selected function. The relay
position is set by the current program.
• Battery backup
- Backlighting not active
- Data key READ/WRITE only via the menu
Supply voltage L
N

Overview of programmed switching times for the


0 6 12 16 24
week. Resolution 0.5h
Function
Switch status
Receptacle for data key
Day, Time, Date

2 1 4

max. 16 A

L
max. 250 V AC N
R c

Operating principle: Typ 1.B. S. T.


IEC/EN 60730-1, IEC/EN 60730-2-7 4000 W 2000 VA 600 W 70µF 2000 W
Operation in a normal environment
Montage: in distribution panel,
+ +
Degree of contamination: 2 +
LED
Switch output, potential-free
Rated impulse voltage: 4 kV 2000 W 2000 W 2000 W 1000 W 1000 W
Select menu, back to main menu,
Hold down > 1s = operating display

Confirm selection or load parameters

Select menu options or set parameters

Overview

2 3 1 7 4

8
9
6


This symbol indicates that the
* Only available in EXPERT mode.

selection is active.

5
A Set language 2 Set time/date, summertime/wintertime

Summertime: ± 1 hour
Europe: Factory set
SPECIAL: The switchover to/from
summertime can be freely programmed by entering
a start date and end date and is then executed each
year on the same day of the week, e.g. Sunday
3 Programming
A program consists of an ON time, OFF time and associated on and off days.
Programs with predefined on/off days (Mon to Sun, Mon to Fri and Sat and Sun): for these programs,
you only need to set the switching times.
With the „INDIVIDUAL” option,
you can allocate switching times to
specific days of your choice.
The programs of a channel are combined
Set MON and TUES
with a logical OR.
as on/off days

*
CHRONO = All switch commands are executed in chronological order in a week
INPUT = Programs are executed in the order in which they are entered
4 Modes
• Auto - Automatic operation
• Constant ON
• Constant OFF
• Extra
The switch status imposed by the
program is inverted (manual override).
With the next effective switch command,
the time switch resumes control of on/off
switching.

5 Contrast adjustment  1 h-Test


When this function is activated, the output is switched on
for one hour.

After one hour, the time switch returns automatically to


the programmed mode.
 Data key

or

4 128 72/73
Load the programs of the time switch on to a data key (WRITE KEY)
Warning! all programs stored on the data key will be overwritten.

or

Load the programs from the data key to the time switch (READ KEY)
Warning! all programs programmed in the time switch will be overwritten.
 Hour counter
Displays the total relay ON time, (0 to 65535 h) and the date of the last reset.

 Random function
Function to simulate presence.
Function active: the programmed switching cycles are shifted at random within the range of ± 15 minutes.
 Pincode

PIN CODE active: The menus of the time switch will not be accessible unless the PIN CODE has been
entered. When the pin code is active, access to the button and key functions is disabled 1 minute after the
last button press.
PIN free access can be re-enabled by selecting PASSIVE or by resetting the device.

Example
 Expert mode
Some additional functions are available in Expert mode:
• Power grid synchronisation to improve the accuracy
• Cycle function
• Automatic channel switching

Note: Upon switching from ACTIVE to PASSIVE the additional menu items are hidden again and all the
Expert mode settings are cancelled. After re-activating, Expert mode will operate again with the basic
settings.
 Holiday

After activation the holiday program is executed between 0:00h on the start date and 24:00h on the end
date (Constant ON/OFF). After the holiday program has run once, it must be reactivated.
 Activating and deactivating grid synchronisation

Only available in EXPERT mode.


The default setting is PASSIVE. In order to improve the long-term accuracy, it is advisable to activate syn-
chronisation if the time switch is supplied from a on 50/60 Hz grid with frequency adjustment.
 Cycle function
Only available in EXPERT mode

For cyclical switch commands the switching on time is set by logical “OR“ of programs of all types. A fixed
cycle of ON and OFF time then operates within those limits. The cycle always starts with the ON time.
The cycle duration and the ON time within the cycle are the same length for all switching times. The cycle
duration and the ON time can be set independently in one-second increments. If the switching time is shor-
ter than the cycle duration, the cycle will be shortened accordingly. The ON time will remain unchanged. If
the switching time is actually shorter than the ON time, the ON time will be shortened accordingly.

min max
Period 2s 2h
Pulse 1s 1h 59min 59s
15:00:00 15:10:00 15:20:00 15:30:00
0:10:00 0:10:00 0:10:00
15:32:00

Program n
Program 1

Relais Chanal 1
0:04:00 0:04:00 0:04:00
Warning: Elektrical shock - Disconnect all power from the
Reset device before dismantling the module and replacing the
Warning! battery.
The memory will be cleared, Always use a Li cell type battery (LiMnO ) CR2477, 3V
2

and all set data will be lost. high temperature type min +85 °C
Hold down for more than 3 seconds
and at the same time press and release
.
The language, time, date, summertime/
wintertime and switching times will have to
be reentered.

+