FOR
AC LOCOMOTIVES
1
ELECTRIC LOCO TRAINING CENTRE.
The air brake system is being introduced both in coaching and freight stock
on large scale. The problems/failures connected with air brake system are dealt with
exclusively and in detail. In addition to the TROUBLESHOOTING, this book
consists of Operating Instructions and Operation of Multiple Units,
problems/failures regarding air brake trains and other instructions.
We sincerely hope that the LOCO PILOTS community will make the best use of the
end product of the efforts put in by all of us.
2
DEAR LOCO PILOT.
1. BE ENERGY CONSCIOUS.
3
CONTENTS
TSD for
4 WAG5, WAG7, WAM4(6P), WAP1 and WAP4 class locos
4
STANDARD INSTRUCTIONS FOR LOCO PILOT AND LC.
1. During trouble shooting in block section, utmost care should be taken to trouble shoot
the fault, and resume traction within 20 minutes. If unsuccessful LC/TPC control is to
be informed, for assistance. All efforts should be made to minimize and curtail
detentions in block section.
2. In MU/Consist, if one of the loco fails, try to clear block section, with good loco or
good locos without wasting time for trouble shooting.
3. In case of trouble shooting in MU/Consist locos, the abnormal sign should always be
picked up from leading loco. There after all the observations and interventions shall be
made on the loco which is defective.
4. When ever HOBA is placed in OFF position during trouble shooting in one of the loco
in MU/Consist, HOBA of other locos also to be kept in OFF position.
5. While wedging contactors or relays ensure that the auxiliary contacts are fully operated
and contactors do not chatter after wedging.
7.a) During trouble shooting if MPH is isolated, the train can be worked up to the
destination provided MVRH is working normally and there is no appreciable rise in the
oil level in the transformer gauge.
5
The loco should be withdrawn in a planned manner by the LC.
b) In case MVRH is isolated – Put HC105 on ‘0’,if HC105 is not provided Wedge Q118,
clear block section with the following current rating.
Starting: 920 amps for 10 minutes.
Continuous 500 amps.
c) In case MVSL is isolated – Clear block section with the current rating of 500 Amps.
9. Whenever any equipment (including TM)/relay are isolated on a locomotive, loco pilot
must record in the loco log book and inform LC at the first available opportunity.LC must
ensure planned withdrawal of the loco from service.
10. Driver must record all cases of on line loco troubles/other unusual occurrences/ wheel
slipping, clearly mentioning the time loss in block section/station, time and place of
occurrence as well as information given to LC.
11. Whenever HPAR is placed in “0” position during trouble shooting in one of the loco
in MU/Consist, HPAR of other locos also to be kept in “0” position.
6
DIFFERENCE BETWEEN WAG5, WAM4 (6P) AND WAG7
7
15. TRACTIVE EFFORT 35.6 T (max) 30 T 30.8 T 42 T
used. 18.8 T
(Continuous)
at 72 kmph
16. QD 2 Nos. 2 Nos. 2 Nos
(Differential relay) QD-1 for TM2&3
Locos up to 23384 QD-1 for TM1&3 QD-2 for TM4&5 QD-1 for TM2&3
QD-2 for TM4&6 QD-2 for TM4&5
Locos beyond 23385 QD-1 for TM2&3
QD-2 for TM4&5
17 Main compressors 3 Nos. (MCP1,MCP2 3 Nos. (MCP1, 3 Nos. (MCP1,MCP2
(MCP) & MCP3) MCP2 & MCP3) & MCP3)
8
14. WEIGHT 108.3 T 112.8 T
15. TRACTIVE EFFORT 32.49 T 30.8 T
18.8 T (Cont) at 72 kmph
16. QD (Differential relay) 2 Nos. 2 Nos.
QD-1 for TM2&3 QD-1 for TM2&3
QD-2 for TM4&5 QD-2 for TM4&5
17 Main compressors (MCP) 3 Nos. (MCP1, MCP2 & 2 Nos. (MCP1 & MCP2)
MCP3)
9
TROUBLE SHOOTING DIRECTORY
FOR WAG5, WAG7, WAM4(6P), WAP1 AND WAP4 CLASS LOCOS
Page
Sr.No Contents
No
CHAPTER- ONE
Checking operation of tripping failures & trouble shooting of red
1
target dropped relays
CHAPTER- TWO
2
Tripping failure
CHAPTER-THREE
Traction failure, Precautions on relay wedging
3
CHAPTER FOUR
4
1. Miscellaneous failures.
2.DRUM contactors in pictorial view with operation
CHAPTER FIVE
1.Trouble Shooting for Static converter loco
2. Trouble Shooting for Microprocessor loco
3. ANNEXURE-A(VCD & its trouble shooting)
5
4. ANNEXURE-B(Working with leading loco in MU/Consist,
when leading loco is defective to clear block section only
5.ANNEXURE-C(Nomenclature of Relays, HMCS position,
Cantilever Assembly, Technical details)
10
TROUBLE SHOOTING DIRECTORY FOR
WAG5/WAG7/WAM4 (6P)/WAP1/WAP4 LOCOS
CHAPTER I
CHECKING OPERATION IN CASE OF TRIPPING FAILURES
Preparation-1
Tripping on line, Bring back MP to 'O'. Wait 15 second for LSGR to glow. Check
panto if found any abnormality do accordingly Refer Page No. -------. Check the relay
targets by physically operating reset button of each safety relay. If any relay target
shows red indication refer the page number as follows.
Srl Abnormal sign TSD
No. PageNo.
3. QLA tripped 00
4. QOA tripped 00
11
2. QLM ALONGWITH Check corresponding CKT.Check RSI block,J-
1,J-2,CTF-1,2,3,Line contactors, shunting
contactors,SJ coils, traction motors, if no
abnormality noticed then
QRSI-1 or QRSI-2 i. Reset the relay indicators — Resume
OR traction.
QLM ALONG WITH If DJ trips again — through the same relays,
QRSI-1, QOP1 Put HMCS on position II, III & IV one by one.
OR Resume traction.
QRSI-2 & QOP2 Observe the above relays dropping
OR Put HMCS in that position
QRSI-1, QRSI-2 ALONG where tripping does not occur, Reset relay
WITH QOP target. Close DJ. Resume traction.
CAUTION
DO NOT PUT HQOP/HOBA IN ‘OFF’ POSITION UNLESS TRACTION MOTOR-
ISOLATION IS TRIED THROUGH OPERATION OF HMCS.
12
To reset Mechanical QLM
13
Probable defects Action to be taken by the Driver
observation/checking
3. IF QLA HAS TRRIPED Check for smoke omission from auxiliary
motors,
contactor panel, ARNO and R118 & C118.
If no abnormality — Reset the relay indicator.
Close DJ. Resume traction.
If DJ trips again through QLA.
Check for smoke emission.
If no smoke emission — Reset the relay target,
close DJ.
Resume traction.
14
Probable Defects/ Action to be taken by the Driver.
observation/ checking
MPH Put HPH on "0". Ensure MVRH is working,
Continue Traction not exceed the following
ratings :
920 Amps for 10 minutes
500 Amps continuous.
Check TFP oil level frequently
MCP-1
or
MCP-2
or
MCP-3
or Isolate the defective auxiliary and use the good
one. Resume traction
MPV-1
or
MPV-2.
.
.
15
NOTE: AFTER ISOLATING ANY AUXILIARY MOTOR, ENSURE THE
CORRESPONDING CONTACTOR IS IN OPEN CONDITION AND ENTER IN E
LOCO LOGBOOK, INFORM LC.
16
Put HVSI-1/HVSI-2, HVSL1/HVSL-2 and
HVMT-1/ HVMT-2 on 'O'. correspondingly
If load permits — Resume traction.
If load does not permits — Inform LC.
CAUTION
17
CHAPTER-II
(Tripping failure)
If no relay target shows red indication, to pick up abnormal sign do as given below.
Preparation-2
Ensure MP on “0”, MPJ on “0”& LSGR glows. Open all auxiliary switches except
BLCP”A”.Close BLDJ, Press BLRDJ and observe LSDJ, UA needle & LSCHBA to pick
up “8” abnormal signs as follows :-
2. No tension on line LSDJ goes out but UA OHE supply, Panto, Roof
needle does bar & foreign body on
not deviate loco roof
18
6. OPERATION-1 Take one traction MVSI-1/QVSI-1,
Notch. And wait MVSI-2/QVSI-2
If LSDJ glows Q 44 or SMGR
within15sec.
Case-1
While standing:-
Open DJ,Put both HVSI 1&2 switch on “0”.Close DJ,take 6 traction notches and
wait “15” seconds.if LSDJ glows.
Case-2
While on Run:-
Take 6 traction notches and wait “15” seconds. If LSDJ glows –OP-II.
8. 41 TWAC
DJ trips repeatedly either after checking of OP.-1 in between 2nd to 5th notch or
after checking OP-2 in between 7th to 32nd notch
CHECK PANTO FIRST AND THE RELAY TARGETS AFTER EVERY TRIPPING
19
ICDJ
(LSDJ REMAINS GLOWING [Re-Check relay target, if dropped trouble shoot as per
page No. __)
Remarks -1 For SU
Remarks - 2 For MU/consists-Refer page No 00
Probable defects/
observation/checking Action to be taken by the Driver.
REMARK-I
Ensure BLDJ is closed, LSGR glowing
20
and ZPT is in other than 'O' position.
Check MR pressure and RS pressure. Check
BPEMS in both cab.
21
HQCVAR & HC105 put on ‘O’.Work the train,
while closing DJ manually operate Q118.
(In case of MU manual operation of Q118 in trailing loco is not possible during run .
So Put back all the above switches in position-1 one by one, observe Q118 after 5 secs,
If Q118 gets de-energised :
1) If HVMT-1/HVMT-2/HVRH kept in normal position and Q118 gets de-energised then
put back concerning switch on position III & remaining all other switches on “1”Resume
traction. Observe the working of auxiliary whose switch is kept on position - III. (Relay
isolated).
2) If on keeping HVSL-1/2,or HPH or HQCVAR on 1.If Q118 gets de-energised then
put HVSL-1&2, HPH on III & HQCVAR on 0. Resume traction. Observe the working of
auxiliary whose switch is kept on position - III. (Relay isolated).
22
D. IF Q45 ALONE NOT ENERGISED a. Operate BLDJ few times & Change the
position of ZPT. Ensure GR on '0’. Operate GR
manually from 0 to 1 and back to 0 a few times.
Close BLDJ, press BLRDJ/BP2DJ — Close DJ.
b. If still Q-45 not energised—Operate Q45
manually. Release Q45 after LSCHBA goes out.
Resume traction.
Everey time for closing DJ, Operate Q45
manually.
c. If DJ does not close—Don't release Q45.
Check Q44. If Q44 is energised — try from
other cab.
If DJ closes — Resume traction
Clear the block section, observing the G&/SR in
force.
If unsuccessful — Request for assistance.
23
c. If unsuccessful again—while going to trailing loco. (In
which LSGRPT remains glowing)
Keep leading loco in energised condition, with BLVMT
closed.
Ensure proper fitness of the MU jumpers connected
between locos.
On trailing loco press BP2DJ. Close DJ.
IF DJ CLOSED Come back to leading loco — Resume traction.
IF DJ DOES NOT CLOSE Trouble shoot on trailing loco as per Remark -1.
IMPORTANT INSTRUCTIONS
LSDJ GOES OUT BUT UA FAILS TO DEVIATE AND LSDJ COMES AGAIN
1.CLOSE BLDJ, PRESS - put “ON” flasher light & control the speed
BLRDJ IF UA DOES NOT upto 60 kmph at night
DEVIATE RELEASE BLRDJ - While on run check OHE, PANTO, TRACK
AFTER LSDJ GLOWS AGAIN AND TRAIN,note the Time,KM,& section
-In front and rear.
- If any abnormality noticed — lower panto.
Stop the train, comply with GR 6.03 — Contact LC/ TPC.
If no abnormality is noticed :
Ensure Rs pressure is more than 8.0 kgs/sq. cm.
Close DJ once in every minute for three times.
Don't Release BLRDJ till DJ trips.
If tension restores — Continue traction.
It still tension not restored :
Put other panto into service.
If successful — Clear block section.
- On arrival at station. Try with original panto. If no
tripping — Resume traction.
If tripping occurs.
24
Take Power Block and ground the loco. Check loco roof.
Observe all safety precautions as given below
(REFER IMPORTANT INSTRUCTIONS GIVEN
BELOW)
- If unsuccessful with other panto.
Stop the train near an emergency socket.
Send ALP to check the train with guard
Lower the panto. Check loco roof from ground level. Look
for any abnormality and foreign body.
- Contact LC/TPC.
IF UNABLE TO CONTACT - Raise panto once in every three minutes for three
TPC/TLC times.
- If tension not restored — Lower panto. Ask for
assistance.
- Observe SR 6.04.02 (d)(i).
- If tension restored after 05 minutes clear the block section
at 35/20 kmph as per SR 17.09.01(5)(ii)
LSDJ GOES OUT BUT GLOWS AGAIN BEFORE LSCHBA GOES OUT
OPERATION 'A'
25
Remark -1 for SU
Remark - 2 for MU/CONSIST.
REMARK-II
26
LSDJ & LSCHBA GOES OUT BUT LSDJ GLOWS AGAIN WITHIN 15 SECONDS
AFTER LSCHBA GOES OUT
OPERATION 'B'
Remark - 1 for SU
Remark - 2 for MU/CONSIST. Refer page no. 63
27
1. IF DJ HOLDS Observe the working of both MVSL1 & MVSL 2.
28
Remove Wedge from Q118. Ask for
assistance/Relief loco.
REMARK-II
NOTE
29
LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER CLOSING BLVMT.
OPERATION 'O'
30
- Wedge Q118.
Close DJ — Clear block section.
Observe the working of blowers of M
VRH, M VMT-1 &2.
31
On arrival at station — Request for
assistance.
ii. MVMT1 or MVMT2 not working.
Put corresponding HVMT1 or2,HVSL1
or2&HVSI1 or 2 on 'O'.
If Block 1 is isolated — Take safety
measures.
Wedge C106. Manually operate Q118
— Close DJ.
If load permits — Resume traction.
If load does not permit — Contact LC.
REMARK-II
Trouble shoot as the Remark-I for
leading loco. Proceed to the trailing
loco. Do the same operation as given
under Remark-I for SU/leading loco.
NOTE
1. WEDGING OF Q118 IS NOT PERMITTED ON TRAILING LOCOS.
2. IF MVMT1 IS ISOLATED. WEDGE C106.manually operate Q118 to close DJ.
32
WOAMA Relay with wedging screw COMET Relay with wedging
OPERATION -1
33
Remark -1 for SU.
Remark - 2 for MU/consist.
REMARK-I
- Put HVSI-I & II on position - III.
- Close DJ.
- Take one traction notch and wait for 15
seconds.
2.IF DJ TRIPS AGAIN i. Put the HVSI1 & 2 on position -1. and
check SMGR pressure between 3 to 3.5
kg/cm2 and for any air leakage
- Operate GR manually a few times —
Resume traction,
ii. If unsuccessful.
Isolate the RSI block one by one. If load
permits — Resume traction, iii.
If Unsuccessful — Clear Block Section
by Manual Control of GR.
34
permits — Resume traction. If the load
does not permit — Contact LC.
REMARK II
Trouble shoot as per Remark-I for leading loco.Check the proper fitment of the
MU jumpers.Proceed to the trailing loco.Do the same operation on trailing loco.In
MU/consist — Follow the instructionas given under Remark-I for SU/leading
loco.
OPERATION-II
35
Remark 1 -forSU.
Remark 2 - for MU/consist. Refer page No. 68
Probable defect/ Action to be taken by the driver.
Observation/Checking
REMARK-I
Ensure HVRH, HVMT-1 and 2 on position-l.
Close DJ.Close BLVMT. Check the working of
blowers.
36
ii. If the compressors are not working—
Refer page No. 00 (Miscellaneous failures
for auxiliaries not working.)
REMARK-II
Trouble shoot as per Remark-I for leading
loco. Proceed to the trailing loco. Do the
same operation on trailing loco as given
under Remark-I for SU/leading loco.
During the course of trouble shooting :
When one or more blower contactors are
wedged.
Put HVMT1, HVMT2 and HVRH on
position III. Check Q118.
i. If Q118 is not energised.
Come back to leading loco — Resume
traction.
ii. If Q118 is not energised.
Put back HVMT1, HVMT2 and HVRH on
position I.
Manually operate Q118 on trailing loco.
Close DJ with BP2DJ.
Resume traction. Clear block section.
On arrival at next station.
If the load does not permit—Request for
assistance.
NOTE
1. BEFORE PUTTING HC105 ON POSITION 'O', ENSURE ALL THE
BLOWERS ARE WORKING.
2. AFTER PUTTING HC 105 ON '0\ CHECK WORKING OF BLOWERS
EVERY 15 MTS. ON RUN.
3. ON WEDGING CONTACTORS C105, C106 OR C107 CLOSE BLVMT,
MANUALLY OPERATE Q118. PRESS BP2DJ TO CLOSE DJ.
a. Release BP2DJ after LSCHBA goes out.
b. Release Q118 after all blowers start or after 1 min.
37
TWAC
(TRIPPING WITHOUT ANY APPARENT CAUSE)
IF THE TRIPPING OCCURS SPECIALLY ON HIGHER NOTCHES, CHECK THE
UA. IF UA SHOWING — BELOW 19KV, CLEAR BLOCK SECTION ON LOWER
NOTCHES AND INFORM LC/TPC AT THE NEXT STATION.
38
In case if HPH is kept on III — Continue
traction.
Observing the following current ratings.
Starting - 920 amps for 10 minutes.
Continues - 500 amps.
5.IF TRIPPING OCCURS AGAIN ** Put HQOP-1 & 2 in 'OFF'
position and HQOA on 'O'.
Resume traction.
6.IF TRIPPING OCCURS AGAIN Put HOBA in off position
(On all locos in MU/Consist) —
Resume traction.
7.IF UNSUCCESSFULL Change the cab or loco. Clear the block
section. Observe instructions of SR,
4.21.01 (b)(i).
8. IF UNSUCCESSFULL Try to clear block section by manual
control of GR
9.IF UNSUCCESSFUL AGAIN If tripping permits — continue hauling
the train.
If tripping does not permit — Stop the
train at the
next station/emergency socket —
Inform LC.
Enter in the loco log book.
NOTE 1. ENSURE RS PRESSURE MORETHAN 8.0 KG/SQ. CM AFTER
EVERYTRIPPING
2. OBSERVE IF LOCO TRIPS IN BETWEEN NOTCH 2' TO 5 OR
AFTER NOTCH 6.
39
CHAPTER-III
TRACTION FAILURES
PAGE
b. GR is progressing. 00
40
TRACTION FAILURES
41
Put MPJ in forward position, if LSB extinguished,
Resume traction,
iv. If LSB still remain glowing :
Trip DJ. Take safety measures Wedge Q50.
resume traction.
II. IF LSB IS EXTINGUISHED
a. Check and ensure the following.
i. BP pressure to be 5kg/sq.cm.
ii. PR-2 is in de-energised condition
Iv If QRS is in de-energised condition,
- wedge QRS in eneregised condition
Proper fitting of MP couplers (2 nos).
Operate EEC — Resume traction.
If unsuccessful :
Operate MP or EEC from rear cab.
Clear block section only.
Observe GR & SR rules in force.
b.On arrival at station or if unsuccessful after
changing cab.
v. ENSURE Q51 IS IN DE-ENERGISED
CONDITION.,
If Q51 is in energised condition,
Wedge Q51 de-energised condition — Resume
traction.
vi. ENSURE Q-52 IS IN DE-ENERGISED
CONDITION.
If Q52 is in energised condition,
Wedge Q52 in de-energised condition —
Resume traction.
vii. Ensure ZSMGR knob and ZSMS are in correct
position.
vii. Operate BL few times(both cabs).
ix. Check SMGR pressure is 3 to 3.5 kg/cm2
III. IF Q51 & Q52 ARE GOOD
(ie. DE-ENERGISED) c.i. Operate GR manually few times from 'O' to 10
Put and back to '0'. Resume traction.
ii. If unsuccessful — Clear block section.
Operate manual control of GR inSU/Leading
Loco.
InMU —
If load permits — Clear block section with good
loco.
If load does not permit — Contact LC.
NOTE : 1. In MU Manual Control of GR on Trailing Loco is not permitted.
42
2. In MU/Consist operation while working with EEC, Whenever the GR is
brought to 'O' by BPR — bring MP to 'O'. Before progressing — put MP
again On 'N'
3. After wedging a relay observe safety precautions as mentioned in page
no.
1. Watch and ensure BP pressure and vacuum is adequate and the train is running
safely.
2. Whenever the train is parted, immediately keep MP on '0' and bring GR to 0 '0'.
3. When RS is opened and A-9 is brought to emergency, keep MP on '0'.
2. After closing DJ, close one by one auxiliary switches with a time gap of 5 seconds
43
to avoid overload on ARNO.
3. If DJ trips then before closing DJ, bring MP to ‘0’,MPJ to ‘0’ and put HBA ‘OFF’
then energise the LOCO as per procedure, otherwise ICDJ will experienced.
1. Check the working of all auxiliaries frequently whose interlocks are provided in Q118
branches. i.e., MVRH, MVMT1, MVMT2, MPH, MVSL1, MVSL2.
2. If any auxiliary does not work (or smoke emission found), then open DJ and lower panto
immediately and take precautionary measures.
1. Against regular practice on Neutral Section before arriving “close DJ” board do not close
BLDJ.
2. Frequently check the working of MVSI1, MVSI2.
3. Bring MP to ‘O’ and open DJ if found LOW/NO tension on line, so frequently watch ‘UA’
in driving desk.
4. Observe smoke emission from Q30 and RQ30
5. Observe OHE voltage on UA.
When No-tension on line remains for a long time, then remove the wedge of Q45 to avoid
chattering sound of Q44, Q118.
Precautions after wedging QSVM.
1. BLVMT should be switched on before closing DJ.
2. BLCP should be switched on after 5 seconds of SIV rams up full voltage. (SIV ON LED
glows or LSCHBA extinguishes)
Precautions after wedging QTD101.
BLCP/BLCPD should be switched on after 5 seconds of SIV rams up full voltage. (SIV ON LED
glows or LSCHBA extinguishes)
44
TOTAL LOSS OF TRACTIVE EFFORT
OR
IMPOSSIBILITY TO START DURING TRACTION, AMETERS DO NOT DEVIATE
1. B.GR IS PROGRESSING
CCPT(10A)
+110V
BL1 BL2 VS3
MP1 MP2
-,+,N(TR) GR CL 1-32
-,+,N(TR)
DJ
Q50
L1 L3 L4 L6
CTF1(TR)
CTF2(TR)
CTF3(TR)
HVSI1 HVSI2
0 1 2 3 0 1 2 3
HVMT1 HVMT2
0 1 2 3
L1 L2 L3 L4 L5 L6
45
IF UNSUCCESSFUL TO
RESUME TRACTION In case of SU Loco — Request for assistance.
In case of MU/Consist —
If load permits — Clear block section with good loco. If
load does not permit — Contact LC.
NOTE
In MU/Consist — During starting or on run
IF Ammeters on leading loco deviates abnormally high, check the trailing loco. If GR
progress but both ammeters does not deviate refer 1.b. above.
If both ammeters are deviating on all loco check the train for brake binding.
I. IF LSB DOES NOT GLOW. Ensure MP on O and observe LSB with MPJ 'F' or 'R’. If
LSB does not glow, refer page number 00 (Trouble
Shoot for TLTE during traction).
46
NOTE
Remark -1 ForSU.
Remark - 2 For MU/Consist.
47
IF RIGHT HAND SIDE
AMMETER (A2) DOES
NOT DEVIATE. Put HMCS-2 on IV (TM 6 is isolated). Resume
traction.
REMARK-II.
Trouble shoot as per Remark-I for leading loco.
connection of ammeter--voltmeter
ALL WAG-5A & WAG-5B up to 23384
1. Left hand ammeter Al indicates current for TM3 in both cab.
2. Right hand ammeter A2 indicates current for TM6 in both cab.
3. UMTI in cab 1 indicates voltage for TM1.
4. UMT2 in cab 2 indicates voltage for TM4.
5. QD1 connected between TM1 & TM3.
6. QD2 connected between TM4 & TM6.
Position of HMCS HMCS-1 HMCS-2
I TM-1, 2 & 3 are TM-4 5 & 6 are
in service. in service.
II TM-1 isolated. TM-4 isolated.
III TM-2 isolated. TM-5 isolated.
IV TM-3 isolated. TM-6 isolated.
48
1.b. LSP GLOWS ON RUN WITHOUT SLIPPING AND GR COMES TO 'O' ON
Single/MU/consist for locos 23385 WAG-5A and onwards
49
CONNECTION OF AMMETERS-VOLTMETERS-QD FOR LOCOS 23385 ONWARDS
1. Left hand side ammeter (A1) in both cabs indicate current for TM3.
2. Right hand side ammeter (A2) in both cabs indicate current for TM4.
3. UMT-1 incab-1 (U1) indicate voltage for TM1.
4. UMT-2 in cab-2 (U2) indicate voltage for TM-6.
5. QD-1 is connected between TM-2 and TM-3.
6. QD-2 is connected between TM4 and TM-5.
+ 110V
BL1 BL2
1 MP 2 1 MP 2
CL ON-,0 CL ON N,0
ZSMS CL
ON 1
Q52
BPR1 BPP2
Q51 Q51
Q50 Q50
BPP1 BPR2
ZSMGR CL
6 'O'CLOCK
POSITION
GR CL GR CL
6-32 32-1
VE2
-VE
50
c. If unsuccessful, clear block section from rear cab,
Observing GR & SR rules in force.
ACTION OF Q20
(ENERGISED) If auto regression is experienced without the use of
MPS.It may be due to the action of Q20.
Note the TM voltage at which auto regression takes
place.Resume traction — Work at lower notches.
Note : Do not use MPS,If auto regression takes place with glowing of LSP
on using MPS.
3. SLIPPED PINION - If the damaged traction motor is not detected. Stop the
train. Advise the Asstt. driver to stand near the track. Apply IAB, take two
traction notches. Ask the Asst. Driver to observe Armature of all traction
motors.If any armature rotates —Isolate the corresponding traction motor.
Resume traction — Clear block section.On arrival at station — request for
assistance/Relief loco.
4. LOCKED AXLE. - By moving loco. Observe the rotation of all the wheels.
If any pair of wheels are not rotating—isolate that particular TM. Move the
loco forward and backward two to three times. Observe wheel rotation.
If all wheels are rotating - Continue traction. If any pair of wheels is not
rotating — Request for assistance.
51
CHAPTER-III
MISCELLANEOUS FAILURES
2. ELECTRICAL FAILURES -
a. Pantograph failures 00
52
n. Cab fans are not working 00
1. PNEUMATIC FAILURES
Abnormal sign or
observation Action to be taken by driver.
53
Abnormal sign Action to be taken by driver.
or observation
Isolate the corresponding sander electro valve. Close
the sanding cut out cock,
vi. In case of leakage or damage from MU air hose.
Isolate angle cock between the locos. Build up MR
pressure individually on each loco. Resume traction,
vii. In case of air leakage from Auto Drain valve.
Close Auto Drain valve isolating cock,
viii. In MU/Dead loco — Ensure LT cock/MU-2B
on trailing loco is on closed/trail position.
ix. Ensure no leakage from IP. If there is any
leakage from IP. Close I.P. isolating cock.
x.Observe continuous air leakage from air dryer if
found so, then isolate air dryer.
b. RS PRESSURE
NOT BUILDING UP i.Ensure BA voltage is more than 80 Volts,
ii. Ensure CPA is working
iii. Ensure RAL is open
iv. Ensure RS drain cock & CPA drain cocks is
closed,
v. Change the panto,
vi. Check leakage from CPA, safety valve, VEPT,
RDJ and its drain cock, DJ oil separator.
If there is no leakage — Close RAL cock.
Build up pressure for ten minutes.
Even if RS gauge does not indicate any pressure.
Raise panto — Close DJ.
vii. Tap RS non-return valve gently(Z type)
c. BP PRESSURE
NOT BUILDING UP/
MAINTAINING. Close BP angle cock of loco towards train.
Check BP gauge in both CABS,
54
c. Check leakage from :
i. DAB/A9 - Operate A9 few times - properly. Drain the moisture in MR.
If unsuccessful — Change the cab. Work the train as per GR & SR rules
in force,
ii. C-2 VALVE - If necessary, gently tap. iii. D1/D2 — Emergency valve if
necessary, operate few times, iv. In MU : Check BP air hose and angle
cock for leakage or damage in MU.
AIR-STOCK- Close BP angle cock between locos. Energise from trailing
loco — Clear block section.
VACUUM-STOCK — Do same operation. Wedge QRS on trailing loco.
Energise from leading loco. Resume traction. — Clear block section.
On arrival at next station -Change the damaged BP hose of loco.
d. BP NOT DROPPING
BY DAB/A9 1. Operate DAB/A9 a few times.
2. If unsuccessful, drain MR.
3. Ensure in non driving cab,
DAB (A9) isolating cocks are in close position.
4. If still unsuccessful drive from rear cab.
Observe GR & SR rules in force.
5. Gently tap BP charging C2 relay valve
e. LOCO BRAKES
NOT RELEASING i. Keep IAB/DAB in released position.
ii. Move the isolating cock of C3W distributor valve
towards CAB-1.
iii. Release C3W distributor valve of loco/locos.
Ensure the brake cylinder gauge needle comes to
'O'.
iv. In MU Ensure MU2B valve in trail position in
trailing loco,
v. Drain out full presure.Rebuild pressure — Release
loco brakes. If still brake do not release. Tap gently
on C2 relay valve of brake cylinder.
vi.Isolate bogie brake C.O.C & ensure all BC pressure
goes to atmosphere through the C.O.C vent ,then
open the C.O.C
f. BP PRESSURE
55
FLUCUATING
ON RUN. Use BLCPD. Maintain minimum 9 kg sq. cm. MR
pressure.
NOTE
1.By reducing the Control Reservoir pressure to 1.4 Kgs. by HS4 Valve, vacuum
may be increased by 4 to 5 cms. 2.
2.In case of Vacuum stock, if leading loco is defective Wedge PV Contactors
(C111/C121)
56
Abnormal sign Action to be taken by driver.
or observation
2. ELECTRICAL FAILURES
A. PANTOGRAPH FAILURES
i. Check MR/RS pressure is more than 8 Kgs./sq.cm.
ii. Change the position of ZPT.
iii. If other panto raises - resume traction.
iv. If other panto does not raise - check CCBA &CCPT.
v. If CCBA & CCPT are good - check VEPT isolating cocks for proper opening.
Operate VEPT manually few times — Resume traction,
IF CCPT MELTS i. Renew the fuse — Resume traction,
IF CCPT MELTS AGAIN ii. Put HOBA in 'OFF' position on ail locos.
Renew CCPT — Resume traction,
IF CCPT AGAIN MELTS iii. Change the panto.
If unsuccessful — Request for assistance.
IF PANTO IS DAMAGED iv.Stop the train. Take emergency power block.
Secure the panto & broken parts properly.
Open the concerning HPT.
Close the concerning VEPT cut out cock.
Resume traction with other panto.
B.DJ LOCKED IN CLOSED POSITION
I. LSDJ extinguished on unlocking BL i.If the panto is raised —
LSDJ NOT GLOWING BUT LSCHBA, Lower the panto immediately.
LSGR & LSGRPT GLOW.IF MPJ kept Ensure glowing of LSDJ in other cab.
“F”or “R” LSB lamp will glow ii.If LSDJ glows — Resume normal
OR traction,
iii. If LSDJ does not glow — increase
MR/RS
Pressure to more than 8 kgs./cq. cm.
— open BLDJ.
57
Abnormal sign Action to be taken by driver.
or observation
In case of NO-Tension vii. Frequently check for any smoke emission from
on line LSDJ does not glow. power/auxiliary circuit.
UA drops to zero LSCHBA Ensure proper functioning of the auxiliaries on run.
glows and auxiliary sound Check safety relay targets.
reduces. viii. If UA does not deviate — lower panto.
Observe instructions on page number 8 for
'No tension' on line.
NOTE
IF Q100 IS ENERGISED,
Take safety measures — wedge all contactors. Close
DJ by manually operating Q118. Resume traction.
58
iii. In MU/consist:
if load permits—clear block section with good loco. If
load does not permit — contact LC.
[Press BLSN for checking defective loco] II. If
CCA holds —
Close BLCP(A), BLPV & BLVMT
one after another and observe CCA.
59
and also wedge Q-100 in de-energise condition.
Resume Traction by operating Q118 manually. Work
the train upto destination after taking other
precautions.
In MU on trailing Loco.
i. If load permits — Continue traction with leading
loco,
ii. In MU if leading loco is defective : Follow as
above.
60
H.CPA DOES NOT a. Check fuse CCBA.
START WHEN ZCPA b. If fuse is melted - replace fuse CCBA.
IS CLOSED. c. If it melts again - put HOBA in 'OFF' on all
locos. Replace fuse CCBA - Resume traction.
d. If the fuse is good - check the terminal of ZCPA. If
disconnected, connect the same. Resume traction.
61
N.CAB FANS ARE NOT
WORKING. Check CCVT - If melted renew CCVT.
S. LSB GLOWING DURING RB. i.Bring MP to '0' - Wait till LSB extinguishes.
ii.Check QF1, QF2 and QE.
iii.If any of them is showing RED, reset & use
RB.
iv. If LSB glow again and the above target
drops -Do not use RB.
v. If all targets are normal Use RB not
exceeding - 650A/325V.
62
IN THE SAME ARM Isolate the corresponding block. If load permits
- Resume traction. If load does not permit -
Contract LC.
3. IF NO FUSE IS MELTED Ignore the glowing of LSRSI.
Enter in the loco logbook - Inform LC.Resume
traction.
63
REVERSER J – 1 & J - 2
64
TROUBLE SHOOTING FOR STATIC CONVERTER LOCO
65
ICDJ
1.Ensure QSIT in de energise & LSSIT extinguished, check SIV panel also in addition to
normal checks.
2.Trouble shoot as per TSD.& follow the following trouble shooting
i)If Q45 & Q44 both energized, then ensure RDJ drain cock closed, air control
cutout cock is open, check VCB pressure 4.8 kg/cm2,MR/RS pressure more than 8
kg/cm2 & then close DJ.
If unsuccessful
ii) Put HQOP-1&2 in ‘off’ position & close DJ.
If unsuccessful
iii) Put HOBA in ‘off’ position.
If unsuccessful
iv) Put HBA in ‘off’ for 3 minutes &close DJ.
If unsuccessful
v) Contact with TLC
NO TENSION ON LINE (If provided, H-3 will also glow)
Trouble shoot as per TSD
Note: In case of OHE voltage above 31 KV & SIV does not start but DJ in closed
condition ,Contact TLC/TPC or wait for normal tension in OHE.
LSRSI REMAINS GLOWING
Trouble shoot as per TSD
TWAC
Trouble shoot as per TSD.
If unsuccessful
Put HBA in ‘off’ for 3 minutes &try.
DJ trips through all safety relays except QSIT
Trouble shoot as per TSD
DJ trips through QSIT & LSSIT glows
i)Check all auxiliary circuit for smoke emission from all auxiliary motors,
contactor panel, switch panel,SIV panel, cab fan,cab heater etc.In addition see
display of VFD panel for fault message & also check any fault LED glowing.
If smoke emission found:- Trouble shoot as per TSD
If smoke emission found from SIV panel: - contact with TLC after taking safety
precautions as per GR&SR
ii)If no abnormality found:-
Reset QSIT, close DJ & resume traction
iii)If unsuccessful :-
Remove CCSPM & change the position of HRAVT one by one, change
the position of HCP/ZPV,Reset QSIT,close DJ
iv) If unsuccessful:-
Put all the auxiliary switches on ‘0’& BLCP,BLPV&BLVMT in open
position ,Reset QSIT & close DJ.
If successful, Put all switch to normal position one by one & isolate the
faulty motor/auxiliary and work accordingly.
v) If unsuccessful:-
Put HOBA/HBA in ‘off’ for 3 minutes &try.
66
vi) In case of earth fault indication
Put HSIV in ‘0’ position, Press earth fault bypass push button
(ELD).Reset QSIT ,Close DJ& clear block section within 45 minutes.
Then contact TLC.
vii) If unsuccessful:-
Contact with TLC with SIV MAKE & fault message in VFD panel.
OPERATION- A (While closing DJ releases BLRDJ as soon as LSDJ extinguished)
Checking sign: Same as conventional loco
Probable cause :- i) Q30 or its NOI on Q44 branch
ii)GR on ‘0’ I/L on Q44 branch
iii) NCI of QCON on Q118 branch
Trouble shooting:-
Close DJ & try to release BLRDJ after LSCHBA extinguishes.
a) If DJ trips before releasing BLRDJ:-Close DJ by manually operating
Q118 every time (NCI of QCON on Q118 branch defective)
b) If DJ trips after releasing BLRDJ:-Wedge Q45 in energise condition
& clear block section with safety precautions
OPERATION- B (BLVMT should remain in open position)
Checking sign: Same as conventional loco
Probable cause :- i) NCI of C105, C106, C107 on Q118 branch
ii) MPH/QPH, MVSL/QVSL-1&2
Trouble shooting:-
Close BLVMT first, and then check operation B.
i) If DJ holds: - Resume traction, always close BLVMT before closing DJ
ii) If DJ trips: - Trouble shoot as per TSD (QCVAR is removed in this
loco)
OPERATION-O
Checking sign:-
Same as conventional loco (Wait15seconds after LSCHBA goes out)
Probable cause: - Same as conventional loco
Trouble shooting: - Same as conventional loco
Note:- On isolating Block -1, wedging of C-106 & manual operation of Q118 is not
required
OPERATION-I
Checking sign:- Same as conventional loco
Probable cause: - Same as conventional loco
Trouble shooting: - Same as conventional loco
OPERATION-II
Checking sign:- Same as conventional loco
Probable cause: - Same as conventional loco
Trouble shooting: - Same as conventional loco
Note:-
After wedging any blower contactor manual operation of Q118 is not required.
MISCELLANEOUS FAILURE
A) DJ closes but SIV does not start:-
67
a) Check OHE voltage, if more than 31 KV, wait till OHE tension becomes
normal or contact with TLC/TPC
b) Check CCINV,
If melts, renew the same
If again melts, put HOBA position & try.
c) If CCINV is good:-
Close BLVMT, SIV will start after 2 seconds & resume normal traction.
If unsuccessful or on closing BLVMT, SIV does not restart:-
a) Check QSVM,
If de-energised, check CCA
If CCA melts, renew the same,
If CCA again melted, Put HOBA in ‘OFF’ position.
If CCA found good, trip DJ & wedge QSVM, Resume traction
(BLVMT to be switched ON before closing DJ)
b) If QSVM in good condition
Put HBA in ‘off’ for 3 minutes &close DJ.
If unsuccessful isolate all the auxiliaries.
If successful put normal one by one.
If unsuccessful Contact TLC.
NOTE:-Do not operate any programme switch when SIV is in ‘ON ‘condition.
B) QCON defective:-
Indication:-
i)LSCHBA does not extinguish, DJ remains in closed condition& SIV
remains in ‘ON’ position
ii)CP will not work on closing BLCPAor BLCPD
iii)H-1 lamp will not glow.
Trouble shooting:-
Wedge QCON in energized condition with following precautions
i)While closing DJ manually operate Q118
ii)BLCPA to be put ON after 5 seconds of SIV picks up.
iii)If experienced ICDJ after wedging QCON,first close DJ ,then wedge QCON
C) CCA melts:-
Indication:-
i) All auxiliaries running with contactors will not start
ii) On closing BLVMT, SIV will not restart.
iii) On run Auxiliaries stop working, if GR is above 5th notch, DJ will trip.
Trouble shooting:-
i) Open HBA,Renew CCA,then close HBA,
if again melts-Put HOBA in ‘OFF’ position & try.
if again melts- Put back HOBA in ‘ON’ position, remove CCA,wedge required
numbers of contactor , QSVM &follow precautions:-
a) Create leakage from MR drain cock
b) Before closing DJ,close BLVMT
c) While closing DJ, manual operation of Q118 is not
required
68
if melts again on closing BLCPD-
1) Change the position of HCP &renew CCA
If melts again-
1) Put HCP on ‘0’
2) Wedge contactor of CPs (as per requirement)
3) Open BLCP, renew CCA
4) Create slight leakages from drain cock of MR
b) Close BLVMT, check CCA
if melts-
2) Open BLVMT & renew CCA
Wedge C105, C106, C107, and QSVM & follow
precautions:-
a) Before closing DJ,close BLVMT
b) While closing DJ, manual operation of Q118 is not
required
69
TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BY
SIEMENS
70
following relevant precautions.
4 Out side fault / External fault with 1. Put HBA on 0, check any abnormality in
fault message on scroll display as auxiliaries, if found so, isolate the defective
* EARTH LOCK auxiliary, again put HBA on 1 and energise the
loco.
71
TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BY
AUTO METER (KIT2/3)
72
normal and close DJ. On putting particular switch on 1 if
DJ trips, put that particular switch on 0 and work the
train following relevant precautions.
* If DJ trips again and same message shows, ask for
relief loco
9 External Earth Fault with 1. Put HBA on 0, check any abnormality in auxiliaries, if
message on scroll screen as any isolate the defective auxiliary, again put HBA on 1
follows: and energise the loco.
* ELD _ FT
2. If there is no abnormality in auxiliaries but fault
massage again comes, put HBA on 0, open all BL
switches, put HPH, HVSL-1&2, HVSI-1&2, HVMT-
1&2, HVRH and HRAVT on 0 (if HRAVT is not
provided, remove CCRA-1, CCRA-2, CCVT fuses,
manually trip MCB near TFVT) , again put HBA on 1
and energise the loco.
73
TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BY
AUTO METER (GENEREC)
Duties of Loco Pilot when DJ/VCB trips.
74
message on scroll screen as energise the loco.
follows:
ELD _ FT * If unsuccessful, put HBA on 0, check any
abnormality on auxiliaries & isolate the defective
auxiliary, again put HBA on 1 and energise the loco.
75
TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BY
HIND RECTIFIER (HIRECT)
76
particular switch on 1, if DJ trips put that particular
switch on 0 and work the train following relevant
precautions.
4.If DJ/VCB trips again and comes fault message
again, put all auxiliary switches on normal, put
HSIV on 0 provided on TB panel, press Reset Push
Button provided on SI unit and energise the loco.
Clear block section and inform to TLC. If Earth
Fault Bypass switch or HSIV not provided, ask for
relief loco.
77
INSTRUCTION FOR TROUBLE SHOOTING OF STATIC INVERTER
VFD and trouble shooting to be done accordingly. HSIV Switch is provided to by pass earth fault
occurs in auxiliary power circuit.
SI
Fault code/ indications Action to be Taken by crew
NO.
A SIV fails to start (i) Check CCINV fuse. If melted, replace it.
without any (ii) if CCINV repeatedly melt put HOBA OFF in all
indication. locomotives & replace CCINV fuse.
(iii) if again fails to start, trip the loco, put HBA OFF,
wait for 2 seconds & try again.
B OHE OUT OF If OHE Voltage is not in between 17.5 KV, then wait
RANGE, (H-3 lamp for normalization of OHE or contact TLC/TPC.
glowing)
C Internal fault, rectifier Reset the STC by pressing RESET Pus button switch
fault , fan fault , fuse provided in the STC front cover.
trip, etc. (H-2 lamp If not provided, trip the loco, put HBA OFF , wait for
glowing) 2 seconds and try again.
D Outside fault, (i) check for smoke emission from auxiliary motors,
External fault, Earth contactors panels, SIV. Ensure all contactor are
fault etc.(H-4 lamp open.
glowing).
(ii) if now abnormalities, close DJ, Resume traction.
78
SI
Fault code/ indications Action to be Taken by crew
NO.
E SIV fails to start after (i) check CCINV & CCA fuse (both locos in case
putting BLVMT ‘ON’ of MU) & Replace if melted.
(ii) if both are OK, check QSVM relay. If not
rectified ask for assistance.
(iii) Wedge the QSVM relay & put BLVMT
‘ON’ SIV will start along with all blowers.
F Tripping after starting Refer TSD page no. 63 and trouble shooting will
of blower motors. be done for tripping in operation ‘O’
G CCA melting even Wedge C101, C102, C103, C105, C106, & C107.
HOBA ‘OFF’ Energize the converter and work as per advice of
TLC.
Note: wedging of Q118 in rear loco is not
required for SIV locos during wedging of C105,
C106 & C107.
NOTE:
(i) HSIV & HRAVT switches are provided on the switch board.
(ii) HSIV switch is to be put ‘0’ in case of earth fault in auxiliary circuit when-
(a) the loco motive is stuck up in the middle of block section and to work the train
up to next section for 45 minutes only.
(b) it is not possible to identify & isolate the faulty circuit.
(c) Earth bypass push button has been passed in SIV.
(iii) The position of HSIV shall be restored to ‘I’ , After rectification of the faultand
entry must be done in the log book by the loco pilot and / or maintenance staff.
(iv) SWITCH POSITION OF HRAVT
0 Χ Χ Χ Χ
1 √ √ √ √
2 Χ √ √ √
3 Χ Χ √ Χ
(v) If 3-phase MVRF is provided:-
(a) During RB : Put MP on “0” and open DJ. Bring MP on “P” and then close DJ.
MVRF will stop and MVRF will start working.
(b) After RB : Open DJ, bring MP on “0” from “P”, close DJ and resume traction.
79
TROUBLE SHOOTING FOR UNIFIED STATIC
CONVERTOR FITTED LOCO
(a) Display of status:
fallowing set of status indications are recommended for the driving
crew. The display shall be in from of LED/LED clusters as indicated below:
Following instruction should be followed by the driving crew in respect of the above:
80
3. Red LED indication of This indicates that fault is inside the SIV.
“Internal Fault” comes Normally such fault can not be tackle on
ON line, unless the fault is transient. Driver
should trun OFF the battery, turn it ON again
and energize the locomotive and if
successful, work the train.
81
(b) Display of functional parameters:
1. Input voltage
ΧΧΧ
2. Input current
ΧΧΧ
3. Output voltage Line to Line voltage
ΧΧΧ
4. Output current Line Current
ΧΧΧ
5. CHBA voltage
ΧΧΧ
6. CHBA current
ΧΧΧ
1. Input fuse Failure In case the input fuse is blown due to high current
drawn.
2. Input voltage high Input voltage Exceeding upper limit.
82
9. Output voltage low Output voltage drop below lower limit
14. Input current high In case of input high current conditions persisting.
23. CHBA voltage low Charger voltage drops below lower limit
1. The fault display on the VFD/LCD will appear in case a fault occurs in the SIV due
to internal / external causes.
2. The fault in plain 20 characters text will appear on the display.
3. the faults will remain displayed till the operator / driver acknowledges them by
pressing the acknowledgement key.
4. Once acknowledges button is pressed or 110V dc battery power supply to converter
is switch OFF & ON, The fault display will be reset and parameters will be
displayed.
(i) ARNO Loco leading and SIV Loco trailing :
In case ,ARNO Loco in leading position, as per the instruction ARNO Loco LP to
switch ‘OFF’ BLVMT and after starting of ARNO loco pilot then Put ‘ON’ BLVMT
with this condition :-
When loco pilot closes DJ leading loco ARNO will start after 3.5 secs. And
starting time of SIV loco is approximately 6 seconds.As and when BLVMT will
switch ‘ON’ the trailing loco,which is SIV,the SIV will switch ‘OFF’ and after 2
83
seconds of delay,the SIV will start again and take complete 8 seconds time to full
voltage.
In this condition,if loco pilot takes notches beyond 5 th notch,the DJ of trailing
loco will trip as the air flow relay of QVMT-1 or QVMT-2 or QVRH are not picked
up.The loco pilot shall be counseled to start taking notches only after extinguishing of
the LSCHBA indication .
84
MICROPROCESSOR LOCO
TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY
MEDHA
If any fault message comes on display unit with buzzer, note the fault message and then press
“Ack”
Sr.No. Fault message on display unit Duties of Loco Pilot
C118 N/C Contact Fail
1 Check C118 is opened fully.
Ensure C118 Opening Do not Press BLRDJ
C118 Stuck up
Release BLRDJ and ensure C118 is
2 Ensure opening of C118
opened fully
Release BLRDJ if pressed
No Tension
3 Wait for OHE Voltage Trouble shoot as per TSD of WAG5
Retry to close DJ
OHE low / No Voltage
4 Trouble shoot as per TSD of WAG5
Apply Emergency Brake
DJ tripped Via QOP-1
5
Reset QOP-1 isolate faulty TM by HMCS-1
DJ tripped Via QOP-2
6
Reset QOP-2 isolate faulty TM by HMCS-2 Trouble shoots as per WAG-5 TSD.
DJ tripped Via QOA
7 Put HQOA on 0
Check all Auxiliary / Heater, follow TSD
8 DJ tripped Via QRSI-1
Reset QRSI-1 isolate faulty TM by HMCS-1 Follow TSD inform TLC
85
9 DJ tripped Via QRSI-2
Reset QRSI-2 isolate faulty TM by HMCS-2
Follow TSD inform TLC Trouble shoots as per WAG-5 TSD.
10 DJ tripped Via QLM
Check transformer / GR oil splashing.
DJ tripped Via QVSL-1
11 Check MVSL-1 if normal Put HVSL-1 on 3
Resume Traction
DJ tripped Via QVSL-2
12 Check MVSL-2 if normal Put HVSL-2 on 3
Resume Traction
DJ tripped Via QVMT-1
13 Check MVMT-1 if normal Put HVMT-1on 3
Resume Traction Put corresponding switch on 3, close DJ
DJ tripped Via QVMT-2 and check corresponding auxiliary.
14 Check MVMT-2 if normal Put HVMT-2on 3 - If auxiliary is working, work the train.
Resume Traction - If auxiliary is not working, isolate the
Check MVRH if normal Put HVRH on 3 particular auxiliary and work the train
15
Resume Traction following relevant precautions.
DJ tripped Via QVSI-1
16 Check MVSI-1 if normal Put HVSI-1on 3
Resume Traction
DJ tripped Via QVSI-2
17 Check MVSI-2 if normal Put HVSI-2on 3
Resume Traction
DJ tripped Via QPH
18 Check TFP oil level frequently
Put HPH on 0 & clear block section.
19 DJ tripped due to GR stuck between notch Bring GR to 0 manually, close DJ and
Bring GR to 0 manually. clear block section by manually control
Clear block section manually. of GR
20 DJ tripped due to Low / No ARNO voltage Inform to TLC and ask for relief loco.
21 DJ tripped Via QLA.
Isolate faulty auxiliary machine, if fault
exists make loco dead and inform to TLC. Trouble shoots as per WAG-5 TSD.
86
QVRF not working
23 Do not use DBR.
Do not use Dynamic Braking.
ICDJ through QOP-1 Dropped
24 Put HQOP-1 OFF Trouble shoots as per WAG-5 TSD.
On running condition watch HTC
ICDJ through QOP-2 Dropped
25 Put HQOP-2 OFF
On running condition watch HTC
ICDJ through QOA Dropped
26 Put HQOA on 0
Check auxiliary machines
ICDJ through QLM Dropped
27 Check HT compartment for Oil splashing.
Inform to TLC.
28 ICDJ through QRSI-1 dropped
29 ICDJ through QRSI-2 dropped.
ICDJ through QLA dropped
30 Check ARNO
Inform to TLC
ICDJ through QPDJ dropped
31 Check RS pressure / leakage Trouble shoots as per WAG-5 TSD.
Start CPA to build up pressure
Reverser are neither in F or R
32 Set the Reverser manually Trouble shoots as per WAG-5 TSD.
Resume traction
CTFs are neither in T nor B
33 Set the CTFs manually on T side only. Trouble shoots as per WAG-5 TSD.
Resume traction.
GR not in Zero
34 Put GR at 0 manually Bring GR to 0 manually and close DJ
Close DJ
Brake applied through IP Close IP cut out cock and do not use
35
Do not use DBR DBR
36 Auto regression Via RGEB Ensure BP pressure is 5 kg/cm2 intact.
If not Brake applied check for leakage
- If auto regression takes place due to
wheel slip, press QD and apply sanders.
Auto regression Via QD
37 - If auto regression takes place due to
Press BPQD / Resume traction
traction motor defects, isolate defective
traction motor.
Auto regression Via TM over voltage Work the train on lower notches and
38
Check TM voltage inform to TLC
Braking Fault SWC Operated Ensure SA-9 is in released and do not
39
Do not use Loco Brake during DB use DBR
40 Working with One CPU Resume traction and inform to TLC.
41 EEPROM Failed Resume traction and inform to TLC.
87
42 Other CAB display fail Resume traction and inform to TLC.
43 Loco in LT STATUS MESSAGE during LT testing
Press BLDJ
Select Panto After energising loco STATUS
44
Press BLRDJ MESSAGE
HVMT-1 in Position 0
After isolating MVMT-1, STATUS
45 L-1, L-2 and L-3 cut off Half power
MESSAGE
available
HVMT-2 in Position 0
After isolating MVMT-2, STATUS
46 L-4, L-5 and L-6 cut off Half power
MESSAGE
available
HVSI-1 in Position 0
After isolating MVSI-1, STATUS
47 L-1, L-2 and L-3 cut off Half power
MESSAGE
available
HVSI-2 in Position 0
After isolating MVSI-2, STATUS
48 L-4, L-5 and L-6 cut off Half power
MESSAGE
available
49 Reverser not as per MPJ position Trouble shoots as per WAG-5 TSD
50 CTFs not as per MP position Trouble shoots as per WAG-5 TSD
C-145 Open HMCS-1 / 2 not in 1
51 Do not use DBR
Do not use DBR
DBR Overheating or QF / QE operated
52 Do not use DBR
Do not use DBR
Build up RS pressure
53 DJ tripped via DJ FB fail If unsuccessful, inform to TLC / ask for
relief loco
Battery charger Out put fail
54 Check CHBA Trouble shoots as per WAG-5 TSD
Clear block section
Put HBA on 0 and check C-107 is
opened
ICDJ through C-107 Feed back fail
55 Operate C-107 few times manually and
Inform TLC
try to close DJ
If unsuccessful, inform to TLC.
88
GR stuck up on Notches
58 Bring GR to 0 manually and close DJ
Put GR on 0 manually
Put HBA on 0 and check C-107 is
opened fully
DJ tripped via C-107 Feed back fail
59 Operate C-107 manually few times and
Inform to TLC
try to close DJ
If unsuccessful, inform TLC
Put HBA on 0 and check C-106 is
opened fully
DJ tripped via C-106 Feed back fail
Operate C-106 manually few times and
60 Put HVMT-2 on 0
try to close DJ
Clear section and inform to TLC
If unsuccessful, put HVMT-2 on 0, clear
section and inform to TLC
Put HBA on 0 and check C-105 is
opened fully
DJ tripped via C-105 Feed back fail
Operate C-105 manually few times and
61 Put HVMT-1 on 0
try to close DJ
Clear section and inform to TLC
If unsuccessful, put HVM1-2 on 0, clear
section and inform to TLC
Check C118 is fully opened.
62 DJ tripped Via C118 N/C contact fail
If unsuccessful, ask for relief loco
63 ARNO not picking up Inform to TLC / ask for relief loco
64 TM voltage channel Noisy Resume traction and inform to TLC.
65 V965 voltage channel noisy Resume traction and inform to TLC.
66 ARNO voltage channel noisy Resume traction and inform to TLC.
67 User changed configuration / Loco No. Resume traction. STATUS MESSAGE
Communication Link Display in Cab-2
68 Resume traction and inform to TLC
fail
Communication Link Display in Cab-1
69 Resume traction and inform to TLC
fail
70 RTC Fail Resume traction and inform to TLC
71 V 965 Channel fail Inform to TLC / Ask for relief loco
72 ARNO channel fail Inform to TLC / Ask for relief loco
Q-20 will not energise, work the train by
73 TM voltage channel fail
observing Voltmeter and inform to TLC.
74 Auto – regression via ACP Reset ACP and work the train
After putting HPAR on 0, STATUS
75 BPAR put in bypass
MESSAGE
After putting HPAR on 1, STATUS
76 BPAR restored
MESSAGE
89
TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY
STESALIT (FDCS-9648)
Duties of Loco Pilot when DJ/VCB trips
Sr.No. Display panel / Message on screen Duties of Loco Pilot
1 C-118 N/C Contact Fail Check C-118 is opened fully
90
27 ICDJ due to QLM Dropped Trouble shoots as per WAG-5 TSD
28 ICDJ due to QRSI-1 Dropped Trouble shoots as per WAG-5 TSD
29 ICDJ due to QRSI-2 Dropped Trouble shoots as per WAG-5 TSD
30 ICDJ due to QLA Dropped Trouble shoots as per WAG-5 TSD
31 ICDJ due to QPDJ Dropped Trouble shoots as per WAG-5 TSD
32 Reverses are Neither in F nor in R Trouble shoots as per WAG-5 TSD
33 CTFs are Neither in T Nor in B Trouble shoots as per WAG-5 TSD
34 GR Not in Zero Bring GR to 0 manually and close DJ
35 Brake Applied Through IP Close IP cut out cock. Do not use DBR
36 Auto Regression Via RGEB Ensure BP pressure is 5 kg/cm2
37 Auto Regression Via QD - If auto regression takes place due to wheel slip, press
BPQD and apply sanders.
- If auto regression takes place due to TM defective,
isolate defective traction motor and work the train.
38 Auto Regression Via TM Over Work the train on lower notches and inform to TLC.
Voltage
39 Braking Fault. SWC Operated Ensure SA-9 is in release position and do not use DBR
40 Working with one CPU Inform to TLC
41 System Error Resume traction and inform to TLC
42 Other Cab display fail Resume traction and inform to TLC
43 Loco in LT During LT Testing STATUS MESSAGE
44 Auto Regression Via ACP Reset ACP
45 HVMT-1 in Position 0 While isolating MVMT-1 STATUS MESSAGE
46 HVMT-1 in Position 2 While putting HVMT-1 on position 2 STATUS
MESSAGE
47 HVMT-2 in Position 0 While isolating MVMT-2 STATUS MESSAGE
48 HVMT-2 in Position 2 While putting HVMT-2 on position 2 STATUS
MESSAGE
49 HVSI-1 in Position 0 While isolating MVSI-1 STATUS MESSAGE
50 HVSI-1 in Position 2 While putting HVSI-1 on position 2 STATUS
MESSAGE
51 HVSI-2 in Position 0 While isolating MVSI-2 STATUS MESSAGE
52 HVSI-2 in Position 2 While putting HVSI-2 on position 2 STATUS
MESSAGE
53 Reversers Are Not as per MPJ
Trouble shoots as per WAG-5 TSD
position
54 CTFs Are Not as per MP position Trouble shoots as per WAG-5 TSD
55 C 145 Open HMCS-1/2 Not in 1 Do not use DBR
56 C 145 Open DBR overheated Do not use DBR
57 Auto Regression Via QF/QE Do not use DBR
58 Battery Charger Output Fail Trouble shoots as per WAG-5 TSD
59 J Forward Feedback Fail Manually operate J-1, J-2 few times
60 J Reverse Feedback Fail Manually operate J-1, J-2 few times
Sr.No. Display panel / Message on screen Duties of Loco Pilot
Manually operate CTF-1, 2 & 3 few times and put on
61 CTF Traction Feedback Fail
Traction side
62 CTF Brake Feedback Fail Manually operate CTF-1, 2 & 3 few times and put on
91
Traction side
Do not use DBR
Put HBA on 0 and check C-107 is opened.
63 ICDJ through C-107 Feedback fail Manually operate C-107 few times and try to close DJ
If unsuccessful, inform to TLC
Put HBA on 0 and check C-106 is opened.
Manually operate C-106 few times and try to close DJ
64 ICDJ through C-106 Feedback fail
If unsuccessful, HVMT-2 on 0, clear section and inform
to TLC
Put HBA on 0 and check C-105 is opened.
Manually operate C-105 few times and try to close DJ
65 ICDJ through C-105 Feedback fail
If unsuccessful, HVMT-1 on 0, clear section and inform
to TLC
Check RS pressure.
66 DJ tripped via DJ FB fail
If unsuccessful, inform to TLC / Ask for relief loco.
DJ Feedback found close before
67 Inform to TLC / Ask for relief loco.
DJ is closed
Auto Regression via DBR pressure
68 Do not use DBR
switch
69 UCDJ due to Q-44 operated Inform to TLC / Ask for relief loco.
BRLDJ released before C-118 is
70 Press BLRDJ 3-4 seconds
energised
71 UCDJ due to feedback failed Inform to TLC / Ask for relief loco.
DJ tripped due to GR stuck on Bring GR to 0 manually, close DJ and clear block
72
Notches section by manual control of GR
Clear block section by manual control of GR and inform
73 Auto regression via Q-50
to TLC
Note: If any fault message comes on display unit, trouble shoot as per fault message. If trouble is not
rectified, before asking relief loco, Loco Pilot do as follows
a. Put HOBA in OFF and try to rectify the trouble.
b. Switch off Battery for 3 minutes and try to rectify the trouble.
92
TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY
ADCFDS
Duties of Loco Pilot when DJ/VCB trips
93
MICROPROCESSOR BASED LOCO
TROUBLE SHOOTING
ICDJ:
1. Check Add. CCBA, CCBA, CCPT & CCCPU. If any fuse melts, renew the same. If again fuse
melts, keep HOBA in OFF and renew the fuse.
3. Check safety relay target, if any relay energized, act according to TSD.
5. Ensure GR on ‘0’
7. Keep HQOP 1 in OFF, HQOP 2 in OFF, and HOBA in OFF and try.
9. Keep HBA on ‘0’, wait for 3 minutes and try to energise the locomotive.
TLTE:
Try to clear the section by manual operation of GR.At times, the fault diagnostic systems
are giving erratic information leading to wrong guidance since they are not stabilized fully.
Hence Loco Pilots should follow the normal procedure of troubleshooting.
94
ANNEXURE-A
VIGILANCE CONTROL DEVICE (VCD)
Operating Instructions of VCD for loco pilot
Do’s Don’ts
After BL key is unlocked, check for ‘VCD OK’LED signal on VCD display panel.If that
LED glows it is an indication that VCD in working condition and it is in service.
If VCD indicates ‘VCD Fault’ then by pass VCD and record in loco log book.
Always keep VCD in service Don’t By pass VCD with out proper reason
Always keep IP valve in service Don’t close IP Valve Cock.If IP valve is closed
VCD indicates as ‘BP-FED-Fault’ at the time of
test/penalty brake.
Always act in time (<76 secs.)to Don’t press ack.push button continuously for more
acknowledge VCD in vigilance than 60 sec.It will lead to application of penalty
cycle(60 secs.)+or flash cycle(8 brake through IP valve with auto regression.
secs.),by any of these methods
a)By any ACK push button or
b) Operate any horn switch or
c)Operate sanders or
d)Notches up/down or
e)Brakes applied through A-9
or SA-9
Note: 1.If brakes are applied by loco pilot through A-9 or SA-9 there is no need to
acknowledge VCD as it is in vigilance suppression mode.
2. When BL key is unlocked VCD will apply test brake as soon as BP pressure
reaches 4.5 kg/cm2 to check whether the IP valve is in service or not
Penalty brake : If VCD is not acknowledged during the above period, it applies penalty
brake for 30 secs. through IP Valve with auto regression
Procedure to Release Brake : After extinguish of yellow flashing LEDs on VCD
display panel, keep MP in ‘0’ position and press any VCD ack pueh button switch to
release brakes.
Bypass VCD :If VCD indicates”VCDFault” on its display panel or behaves erratically
than bypass VCD and record in log book.
How to Bypass : VCD bypass switch is available only in VCD master on its right side.
Brake and open the seal & remove cover to access bypass switch and put it to ‘off’.
95
ANNEXURE-B
96
ANNEXURE-C
TECHNICAL DETAILS
SYMBOL EQUIPMENT SPECIFICATION
RTPR Voltage Stabiliser Input 420 Volts AC±20% (SPECIFIED)
Out put 380 Volts AC±20% (ACTUAL)
i. 32 Volts for head lights.
ii. 24 Volts for instrument, lights.
iii. 16 Volts for dimmer.
Head light bulb 32 Volts - 250 watts.
DC-DC DC-DC convertor Input 110 Volts DC
Output 24 volts DC
Head light bulb 24 volts(100W/90W)
VT Cab fan Input 110VAC±22V2%
RA Cab heaters Input 420 Volts AC±20% (SPECIFIED)
380 Volts AC±20% (ACTUAL)
LC Cab lights Input 110VD.C.
LE Entrance lights Input 110VD.C.
LM Corridor & HT
Compartment lights Input 110VD.C.
LS Signalling lights Input 110VD.C.
FL Flasher lights Input 110 D.C.
SPM Speedometer Input 110 VD.C. (Stabiliser)
Out Put 60 V (Electronic SPM)
24 V (Hasler Berne)
36 V (Autometers)
97
NOMENCLATURE OF RELAYS
SL. NO. SYMBOL FUNCTION
1. QLM High Voltage Over Load Relay
2. QRSI Over Load Relay for Rectifier
3. QE Over Load Relay for Braking Excitation
4. QF Over Load Relay for Braking
5. QOP Earth Fault Relay for Power Circuit
6. QOA Earth fault relay for Auxiliary Circuit
7. QD Wheel Slip Detection Relay. (Current Differential)
8. QCVAR ARNO starting phase Relay
9. QPH Relay for Oil Pump for Transformer
10. QPDJ Pressure Switch for DJ
11. QVRH Air Flow Relay for Transformer Oil Cooling Blower Motor
12. QVMT Air Flow relay for Traction Motors Blower
13 QVSL Air Flow Relay for Smoothing Reactor Blower Motor
14. Q-20 Over Voltage Relay for Traction Motors
15. Q-30 No Voltage Relay
16. Q-44 Protection Relay Rectifier Blower and GR
17. Q-45 DJ Closing Relay
18 Q-46 GR Monitoring Relay
19 Q-48 Wheel Slip Protection Relay. (Time lag & Signalling)
20 Q-49 GR Synchronizing Relay
21 Q-50 Relay for Reversor and CTF
22 Q-51 Relay for Auto-Regression
23 Q-52 Notch to Notch Relay
24 QV-60 Relay for LSDJ
25 QV-61 Relay for LSCHBA
26 QV-62 Relay for LSGR
27 QV-63 Relay for LSRSI
28 QV-64 Relay for LSB
29 Q-100 Relay for Auxiliary Working
30 Q-118 Relay for Auxiliary Protection
31 QSIT Protection Relay for SIV
32 QCON SI on relay
33 QSVM Relay for TM Blower starting
34 QVCD VCD relay
35 QTD 105 Time delay on relay for C105
36 QTD 106 Time delay on relay for C106
37 Q119 Relay for unloader valve
38 QTD 101 Time delay on relay for CPs
39 QFL Relay for Flasher light
40 QPR-1 Time delay on relay for flasher light
41 QVSOL Relay for fault indication in trailing loco
98
PROGRAMME SWITCHES-WAM-4. WAG-5 & WAG-7 LOCOS
SWITCH POSITION
0 I II III
1. HPH MPH ISOLATED SERVICE ISOLATED SERVICE
QPH ISOLATED SERVICE SERVICE ISOLATED
2. HVRH MVRH ISOLATED SERVICE ISOLATED SERVICE
QVRH ISOLATED SERVICE SERVICE ISOLATED
3. HVMT-1-2 MVMT1-2 ISOLATED SERVICE ISOLATED SERVICE
QVMTI-2 ISOLATED SERVICE SERVICE ISOLATED
4. HVSL1-2 MVSL1-2 ISOLATED SERVICE ISOLATED SERVICE
QVSL1-2 ISOLATED SERVICE SERVICE ISOLATED
5. HVSI1-2 MVS11-2 ISOLATED SERVICE ISOLATED SERVICE
QVS11-2 ISOLATED SERVICE SERVICE ISOLATED
0 1 Position - 0 indicates
6. HBA ISOLATED SERVICE
7. HQOA ISOLATED SERVICE BYPASSING QOA
8. ZCPA, OFF ON (SERVICE)
(ISOLATED)
9. HQCVAR ISOLATED SERVICE BY PASSING QCVAR
10. HCHBA ISOLATED SERVICE BY PASSING CHBA
11. HOBA OFF ON OFF BY PASSING RHOBA.
(ISOLATED) (SERVICE)
12. HQOP 1-2 OFF ON OFF BY PASSING RHQOP.
(ISOLATED) (SERVICE)
13 HPAR ISOLATE SERVICE Q51 BYPASSING IN MICROPROCESSED LOCO
99
POSITION. ISOLATION OF TM. VOLT METER/AMP METER INDICATION. QD ACTION
FOR ALL WAG-5 LOCOS UPTO 23384
Symbol Condition No. of TM Indication Amp Meter QD Operation
of/L/Cont isolated volt Meter
HMCS1-I L1,L2, L3 NIL UMT1 deviate A-1 deviate QD1 in Service
closed
HMCS1-II L1 open TM1 UMT1 Not A-1 deviate QD1 supressed
deviate
HMCS1-III L2 open TM2 UMT1 deviate A-1 deviate QD1 in Service
HMCS1-IV L3 open TM3 UMT1 deviate A-1 not deviate QD1 supressed
HMCS2-I L4, L5, L6 NIL UMT2, deviate A-2, deviate QD2 in Service
closed
HMCS2-II L4 open TM4 UMT2 Not A-2 deviate QD2 supressed
deviate
HMCS2-III L5 open TM5 UMT2 deviate A-2 deviate
QD2 in Service
HMCS2-IV L6 open TM6 UMT2 deviate QD2A-2 not deviate
suppressed
APPLICATION ON WAG-5 LOCOS 23385 ONWARD ONLY
CANTILEVER-PARTS:
100
PARTS
1. Mast fitting for hook insulator. 2. Stay tube insulator
3. Stay tube arm 4.Stay tube sleeve
5. Tube cap 6.Mast bracket fitting
7. Bracket tube insulator 8.Register arm hook
9. Bracket tube 10.Register arm dropper
11. Tube cap 12.Anti wind clamp
13. Register eye piece assembly. 14. Drop bracket
15. Steady arm hook 16.Steady arm swivel
17. Steady arm 18.Contact wire
19. Contact wire swivel clip 20.Catenary wire.
101
PANTO PARTS ON LOCO ROOF
INDEX
1. BASE FRAME.
2. BALI BEARING.
3. HORIZONTAL SPINDLE.
4.
5. LOWER ARAL.
6. CENTRAL ARTICULATION.
7. TUBES.
8. TUBE.
9. THRUST ROD.
10. FIXED POINT.
11. TRANSVERSAL TUBE.
12. SLEEVES.
13. SHANK.
14. TRANSVERSAL TUBE END
15. SPRING BOX.
16. ROD.
17. SPRING.
18. BALANCING MEMBER.
19. ARMS.
102
103
104