FMB120 Quick Manual v1.4
FMB120 Quick Manual v1.4
FMB120 Quick Manual v1.4
Warranty Disclaimer........................................................................ 16
Know your device .......................................................................... 3
Pinout ................................................................................................. 4
Wiring scheme................................................................................... 5
Characteristics............................................................................. 11
2 FMB120 | Wiki
Know your device
3 FMB120 | Wiki
Pinout
Table 1 FMB120 2x6 socket pinout
4 FMB120 | Wiki
Wiring scheme
1
Automotive relay
5 FMB120 | Wiki
Set up your device
How to insert Micro-SIM card and
connect the battery
1. Gently remove FMB120 cover using plastic pry tool from both
sides.
2. Insert Micro-SIM card as shown with PIN request disabled or
read our Wiki how to enter it later in Teltonika Configurator.
Make sure that Micro-SIM card cut-off corner is pointing
forward to slot.
3. Connect battery as shown to device. Position the battery in
place where it does not obstruct other components.
4. After configuration, see “PC Connection (Windows)”, attach
device cover back.
Figure 4 Cover removal Figure 5 Micro-SIM card insert Figure 6 Battery connection Figure 7 Attaching cover back
6 FMB120 | Wiki
PC Connection (Windows) Setup will continue installing the driver and eventually the
confirmation window will appear. Click Finish to complete the
setup.
1. Power-up FMB120 with DC voltage (10 – 30 V) power supply
using supplied power cable. LED’s should start blinking, see
“LED indications”.
2. Connect device to computer using Micro-USB cable or
Configuration (Windows)
Bluetooth connection: At first FMB120 device will have default factory settings set. These
• Using Micro-USB cable settings should be changed according to the user's needs. Main
▬ You will need to install USB drivers, see “How to install configuration can be performed via Teltonika Configurator
USB drivers (Windows)” software. Get the latest Configurator version from here.
• Using Bluetooth Configurator operates on Microsoft Windows OS and uses
▬ FMB120 Bluetooth is enabled by default. Turn on prerequisite MS .NET Framework. Make sure you have the correct
Bluetooth on your PC, then select Add Bluetooth or version installed.
other device > Bluetooth. Choose your device named –
Table 2 MS .NET requirements
“FMBxxx_last_7_imei_digits”, without LE in the end.
Enter default password 5555, press Connect and then MS .NET REQUIREMENTS
select Done. Operating MS .NET Framework
Version Links
3. You are now ready to use the device on your computer. system version
Windows Vista
7 FMB120 | Wiki
Various Status window tabs display information about GNSS,
GSM, I/O, Maintenance and etc. FMB120 has one user editable
profile, which can be loaded and saved to the device. After any
modification of configuration the changes need to be saved to
device using Save to device button. Main buttons offer following
Figure 8 Language selection
functionality:
Configuration process begins by pressing on connected device
(Figure 9 Device connected via USB). 1. Load from device – loads configuration from device.
default.
8 FMB120 | Wiki
Default configuration settings
Quick SMS configuration Movement and ignition detection:
Default configuration has optimal parameters present to ensure Vehicle movement will Ignition will be detected
best performance of track quality and data usage. be detected by by vehicle power voltage
accelerometer between 13,2 – 30 V
Quickly set up your device by sending this SMS command to it:
Device makes a record On Moving if one of these events happen:
" setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0"
300 seconds passes Vehicle turns 10 degrees
Note: Before SMS text, two space symbols should be inserted.
Speed difference
GPRS settings:
Vehicle drives 100 between last coordinate
• 2001 – APN meters and current position is
• 2002 – APN username (if there greater than 10 km/h
are no APN username, empty Device makes a record On Stop if:
field should be left) 1 hour passes while
• 2003 – APN password (if there vehicle is stationary
and ignition is off
are no APN password, empty
field should be left) Records sending to server:
If device has made a
Server settings:
record it is sent to the
• 2004 – Domain server every 120
• 2005 – Port seconds
• 2006 – Data sending protocol After successful SMS configuration, FMB120 device will
(0 – TCP, 1 – UDP) synchronize time and update records to configured server.
Time intervals and default I/O elements can be changed by using
Teltonika Configurator or SMS parameters.
9 FMB120 | Wiki
Mounting recommendations
▬ 3 A, 125 V external fuse shall be used.
10 FMB120 | Wiki
LED indications Characteristics
Basic characteristics
Table 3 Navigation LED indications Table 5 Basic characteristics
Accuracy <3m
BEHAVIOUR MEANING
Hot start <1s
Blinking every second Normal mode
Warm start < 25 s
Blinking every two seconds Sleep mode
Cold start < 35 s
Blinking fast for a short time Modem activity
11 FMB120 | Wiki
POWER OPERATING ENVIRONMENT
Input voltage range 10-30 V DC with overvoltage protection Operating temperature (without
-40 °C to +85 °C
battery)
Back-up battery 170 mAh Li-Ion battery 3.7 V (0.63 Wh) Storage temperature (without
-40 °C to +85 °C
battery)
At 12V < 6 mA (Ultra Deep Sleep)
Operating humidity 5% to 95% non-condensing
At 12V < 8 mA (Deep Sleep) Ingress Protection Rating IP41
Power consumption At 12V < 11 mA (Online Deep Sleep) Battery charge temperature 0 °C to +45 °C
At 12V < 20 mA (GPS Sleep) Battery discharge temperature -20 °C to +60 °C
At 12V < 35 mA (nominal) -20 °C to +45 °C for 1 month
Battery storage temperature
-20 °C to +35 °C for 6 months
BLUETOOTH
FEATURES
Specification 4.0 + LE
Sensors Accelerometer
Temperature and Humidity sensor,
Green Driving, Over Speeding detection,
Supported peripherals Headset, OBDII dongle, Inateck Barcode
Jamming detection, GNSS Fuel Counter,
Scanner, Universal BLE sensors support DOUT Control Via Call, Excessive Idling
Scenarios detection, Immobilizer, iButton Read
INTERFACE Notification, Unplug detection, Towing
Digital Inputs 3 detection, Crash detection, Auto Geofence,
Digital Outputs 2 Manual Geofence, Trip
Analog Inputs 2 GPS Sleep, Online Deep Sleep, Deep Sleep,
Sleep modes
Ultra Deep Sleep
CAN Adapter inputs 1
FOTA Web, FOTA, Teltonika Configurator
1-Wire 1 Configuration and firmware update (USB, Bluetooth), FMBT mobile application
GNSS antenna Internal High Gain (Configuration)
GSM antenna Internal High Gain Configuration, Events, DOUT control,
SMS
USB 2.0 Micro-USB Debug
GPRS commands Configuration, DOUT control, Debug
LED indication 2 status LED lights
SIM Micro-SIM + eSIM Time Synchronization GPS, NITZ, NTP
Memory 128MB internal flash memory LLS (Analog), LV-CAN200, ALL-CAN300,
Fuel monitoring OBDII dongle, CAN-CONTROL
PHYSICAL SPECIFICATION Digital Input 1, Accelerometer, External
Dimensions 65 x 56,6 x 20,6 mm (L x W x H) Ignition detection Power Voltage, Engine RPM (CAN Adapters,
Weight 55 g OBDII dongle)
12 FMB120 | Wiki
Electrical characteristics
Table 6 Electrical characteristics
ANALOG INPUT
VALUE
CHARACTERISTIC DESCRIPTION Input voltage (Recommended Operating
MIN. TYP. MAX. UNIT Conditions), Range 1
0 +10 V
13 FMB120 | Wiki
Safety information All wireless data transferring devices produce
interference that may affect other devices which are
This message contains information on how to operate FMB120 safely. By placed nearby.
following these requirements and recommendations, you will avoid
The device must be connected only by qualified
dangerous situations. You must read these instructions carefully and
follow them strictly before operating the device! personnel.
• The device uses SELV limited power source. The nominal voltage is The device must be firmly fastened in a predefined
+12 V DC. The allowed voltage range is +10..+30 V DC. location.
• To avoid mechanical damage, it is advised to transport the device in
The programming must be performed using a PC with
an impact-proof package. Before usage, the device should be placed
autonomic power supply.
so that its LED indicators are visible. They show the status of device
operation.
Installation and/or handling during a lightning storm
• When connecting the 2x6 connector wires to the vehicle, the
is prohibited.
appropriate jumpers of the vehicle power supply should be
disconnected.
• Before unmounting the device from the vehicle, the 2x6 connector The device is susceptible to water and humidity.
must be disconnected. The device is designed to be mounted in a
zone of limited access, which is inaccessible to the operator. All
Risk of explosion if battery is replaced by an incorrect
related devices must meet the requirements of EN 60950-1 standard.
type. Dispose of used batteries according to the
The device FMB120 is not designed as a navigational device for boats.
instructions.
Do not disassemble the device. If the device is Battery should not be disposed of with general
damaged, the power supply cables are not isolated or household waste. Bring damaged or worn-out
the isolation is damaged, DO NOT touch the device batteries to your local recycling center or dispose
before unplugging the power supply. them to battery recycle bin found in stores.
14 FMB120 | Wiki
Certification and Approvals
• FMB120 EAC
• FMB120 REACH
• FMB120 Declaration of IMEI assignment
• FMB120 CE / RED
• FMB120 E-Mark
• FMB120 RoHS
• FMB120 Declaration of device operation temperature
15 FMB120 | Wiki
Warranty Warranty Disclaimer
TELTONIKA guarantees its products to be free of any TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS
manufacturing defects for a period of 24 months. With additional WITH TRAINING AND EXPERIENCE. ANY OTHER USE RENDERS
agreement we can agree on a different warranty period, for more THE LIMITED WARRANTIES EXPRESSED HEREIN AND ALL
detailed information please contact our sales manager. IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY
EXCLUDED. ALSO EXCLUDED FROM THIS LIMITED WARRANTY
Contact us teltonika.lt/company/contacts ARE ANY AND ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES
INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR REVENUE,
All batteries carry a reduced 6 month warranty period.
LOSS OF TIME, INCONVENIENCE OR ANY OTHER ECONOMIC
If a product should fail within this specific warranty time, the LOSS.
product can be:
More information can be found at teltonika.lt/warranty-repair
• Repaired
• Replaced with a new product
• Replaced with an equivalent repaired product fulfilling the same
functionality
• TELTONIKA can also repair products that are out of warranty at
an agreed cost.
16 FMB120 | Wiki