3ARR3, 3ARR22 Type

MOTOR START POTENTIAL RELAY

General Description
A voltage sensitive, electromagnetic type motor
starting relay with normally closed snap-action
Potential Motor Start Relay
contacts used to disconnect the start capacitor on 35A and 50A Rating
capacitor-start, induction-run and capacitor-start,
capacitor-run motors. The relay has a protective
cover which eliminates the need for additional
electrical and mechanical protection. A variety of
mounting brackets are available. Terminals may be
either Quick Connect Tab Type or Screw Type.

Typical Applications
• Central air conditioner compressors
• Submersible pump motors
• Motors generally over 1/3 HP with start
capacitors

Operation
The relay is energized by a magnet coil electrically
connected across the start winding of the motor and Endurance
responds to the increase in start winding voltage as the • 100,000 to 500,000 operations
motor accelerates from zero to the normal running (depending on load)
speed. The relay contacts are actuated by the armature
of the relay to disconnect the start capacitor at a speed
where the motor has sufficient torque to bring it up to Mounting
normal running speed. The relay remains energized • Mounting Bracket
during the run operation of the motor, keeping the relay Select from available brackets in Appendix “C”.
contacts open. When the motor is de-energized, the
relay contacts re-close for the next motor start. • Mounting Position
Each relay is designed for a specific application which Each relay is calibrated in the intended
includes the coil rating for continuous run voltage and mounting position. Specify desired
the pickup and dropout calibration for proper motor mounting position from Appendix “D”.
starting.

Circuits
If there is a terminal in position #6, it must be the same
Terminals polarity as terminals #1, #2, and #4 to prevent possible
• Quick Connect Type flashover. If there is no terminal in #6 position, #4 can
0.250” x 0.032” (6.3 mm x 0.8 mm) be either polarity.
• Screw Type, Tin Plated Brass
#8-32 Thread
Electrical Ratings
• Contacts
35 Amperes max, 50/60 Hz, break only (3ARR3)
50 Amperes max, 50/60 Hz, break only (3ARR22)
• Continuous Coil Rating
60 Hz; 130 to 500 Volts
50 Hz; 117 to 470 Volts
See Appendix “B” for Coil Groups and Ratings.

ZETTLER Controls, Inc. www.zettlercontrols.com


75 COLUMBIA • ALISO VIEJO, CA 92656 • PHONE: (949) 360-5840 • FAX: (949) 360-5839 • E-MAIL: SALES@ZETTLERCONTROLS.COM
12/09/19
3ARR3, 3ARR22 Type
GENERAL OUTLINE DIMENSIONS

Application Procedure
Use the part number scheme from Appendix “A” to create Agency Approvals
part number requirements. UL File #SA 44129
CSA included in UL

Calibration
Relay is factory calibrated for pickup and dropout voltages
to match motor speed and torque curves for the specific
application requirements. See Appendix “B” for
calibrations available for each coil group.

ZETTLER Controls, Inc. www.zettlercontrols.com


75 COLUMBIA • ALISO VIEJO, CA 92656 • PHONE: (949) 360-5840 • FAX: (949) 360-5839 • E-MAIL: SALES@ZETTLERCONTROLS.COM

12/09/19
3ARR3, 3ARR22 Type
APPENDIX A (Ordering Part Number)

Relay model number (Example: 3ARR3AA2A1)


3ARR

Mounting Position (#1 to #6) Appendix D

Coil Calibration (One or two letters) Appendix B

Coil Group (One or two digits) Appendix B

Mechanical Form (One or two letters)* Appendix C

Basic Model Type (3 or 22)**

* Mechanical Form per appendix C or assigned by the ZC Application Engineer as required.


** Basic Model Type is selected based on capacitor disconnect current ("3" for 35A) ("22" for 50A).

ZETTLER Controls, Inc. www.zettlercontrols.com


11/12/14
75 COLUMBIA • ALISO VIEJO, CA 92656 • PHONE: (949) 360-5840 • FAX: (949) 360-5839 • E-MAIL: SALES@ZETTLERCONTROLS.COM

12/09/19
APPENDIX B (Coil Group and Calibration)

12/09/19
ZC MOTOR START RELAY (3ARR3, 3ARR22) DATA

12/09/19
ZC MOTOR START RELAY (3ARR3, 3ARR22) DATA

12/09/19
ZC MOTOR START RELAY (3ARR3, 3ARR22) DATA

12/09/19
ZC MOTOR START RELAY (3ARR3, 3ARR22) DATA

12/09/19
3ARR3, 3ARR22 Type
APPENDIX C (Mechanical Form)

METAL BRACKET MOUNT METAL BRACKET MOUNT


SCREW TERMINATION (QD TERMINALS)
(Bracket 741A584) (Bracket 741A584)
A5 - (5 Terminals, Dual on #4) B5 - (5 Terminals, Dual on #4)
A3 - (3 Terminals) B3 - (3 Terminals)

PLASTIC TAB MOUNT PANEL MOUNT


(SCREW TERMINALS) (QD TERMINALS) (SCREW TERMINALS) (QD TERMINALS)
C5 - (5 Terminals, Dual on #4) D5 - (5 Terminals, Dual on #4) E5 - (5 Terminals, Dual on #4) F5 - (5 Terminals, Dual on #4)
C3 - (3 Terminals) D3 - (3 Terminals) E3 - (3 Terminals) F3 - (3 Terminals)

UNIVERSAL BRACKET MOUNT *


(Bracket 74-500536-5)
(SCREW TERMINALS) (QD TERMINALS)
G5 - (5 Terminals, Dual on #4) H5 - (5 Terminals, Dual on #4)
G3 - (3 Terminals) H3 - (3 Terminals)

* Several bracket mounting options available

ZETTLER Controls, Inc. www.zettlercontrols.com


12/09/19
75 COLUMBIA • ALISO VIEJO, CA 92656 • PHONE: (949) 360-5840 • FAX: (949) 360-5839 • E-MAIL: SALES@ZETTLERCONTROLS.COM
3ARR3, 3ARR22 Type
APPENDIX D (Mounting Positions)

ZETTLER Controls, Inc. www.zettlercontrols.com


75 COLUMBIA • ALISO VIEJO, CA 92656 • PHONE: (949) 360-5840 • FAX: (949) 360-5839 • E-MAIL: SALES@ZETTLERCONTROLS.COM

12/09/19

You might also like