Column Splice Connection

Project: Godrej II
Column: BOX 500X500X25
Input
Steel grade fy 350 Mpa
Axial load on steel col Pu 15000 kN
Assuming 50% laod will b transferred by bearing,
Load on each Splice P1 = (Pu*0.5)/4 1875 kN
Width of steel column B 500 mm
Moment M 130 kNm
Force acting due to moment P2 = M/B 260 KN
Total force on each splice - 4 sides P 2135 KN
Area required A = P/(0.6fy) 10167 mm2
Assuming Width of Plate Wp=B-30 470 mm
Thickness of plate req Tp=A / Wp 21.63 mm
Provide Splice plate thk each side 25 mm

WELD CHECK
Factored Vertical force V 2135 kN
Thickness of the weld t 12 mm
Effective thickness of the weld tw 8.4 mm
Length of the weld (shown in blue) lw =(Ls+Wp) 1470 mm
Actual Shear stress 172.9 N/mm2 OK
Permissible Shear stress q = 0.6fy 210 N/mm2
Provide splice plate length Ls 1000 mm