Compaction Testing SAIC-A-1005 15-Nov-17 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Note: To verify that the area/ material being inspected was tested by
SA approved third party testing agency, the test results attached with
this RFI shall be verified by the relevant PID inspection unit if copy of
the test results had been received directly from the third party lab. If
not available in the PID Inspection Unit, the inspector shall contact
the third party laboratory representative and request for an
explanation. If the explanation is not reasonable, NCR shall be
issued to the third party lab through the Batch Plant and Civil Testing
Group.
Nuclear density gauges, when used, shall have a valid calibration SAES-A-114
A7
certificate per the requirement of ASTM D6938, Sec. 8. Sec. 3.2
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Under foundations with static loads over 320kPa and foundations for
vibrating or heavy machinery and pavements, 85% of relative density
SAES-A-114
A10 (ASTM D4253/ASTM D4254) for cohesionless soils or 95% of of the
Sec. 6.3.6.2
maximum density as determined by ASTM D1557 for cohesive
materials.
The compaction requirement for base coarse shall not be less than
SAES-Q-006
A12 98% of the maximum laboratory dry density as determined by ASTM
Sec. 5.2.2.2
D1557 or AASHTO T180..
The compaction requirement for subbase shall not be less than 95%
SAES-Q-006
A13 of the maximum laboratory dry density as determined by ASTM
Sec. 5.2.2.2
D1557 or AASHTO T180..
The depth of the test holes shall be no greater than 300mm (12 SAES-A-114
A15
inches) deep. (ASTM D 2922, Sec. 1.1) Sec. 6.4.2
REMARKS:
REFERENCE DOCUMENTS:
1- SAES-A-114 -- Excavation and Backfill, 30 September , 2014
2- SAES-Q-006 -- Asphalt Concrete Pavement, 26 November 2014