Load Sensing Control Block SB12 PDF
Load Sensing Control Block SB12 PDF
12
Load-Sensing Control Block Replaces:
RE 64 386/11.10
SB12
Application areas
– fork lift trucks
– construction machines
– municipal vehicles
– harvesters
Operating instructions
– Part 1: General information: RE 64 020-B1 Repair instructions
– Part 2: SB12 directional control valves for mobile – directional control valve block, series SB12:
applications: RDE 64 386-R1
RE 64 386-B2
2/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
valve 3
6 End plate 7
7 Shuttle valve for load-pressure selection
B
A
1 0 2
4
1 0 2
2
R P
Modular system
A1 B1 A2 B2 EF C1 D1 C3 D3 GH
EM
ES RM
PN
1 0 2 1 0 2
L20 L30
1 0 2 1 0 2 F
L50 L70
Q1 Q2 Q3
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 3/40
L 30 – A1 B2 Q1 – RM
2. Spool symbol
EM direct operated electromagnetic actuation
1 0 2
20 1 Switching
2 Proportional
1 0 2
30
RM Detent, mechanical release
1 0 2
50
ES1 Electrical switch
1 0 2 F
70
ES2 Position sensor
C3 Check valve, in A
D3 el. actuated in B
E Secondary PRV in A
F adjustable in B
Mechanical actuation – M
Characteristics
General Valve blocks consisting of:
1 port plate, 1 end plate
1...10 directional control valve elements and shuttle valves
3 tie bolts
Mass Directional control valve, mechanically actuated: 3.0 kg
Directional control valve, electrically actuated: 3.8 kg
Port plate: 2.7 kg
End plate: 1.8 kg
Fixing Thread in port plate and end plate (standard: M 8)
Line ports Internal thread, see order details
Installation position As desired
Port plate configuration Standard: left-hand version
Ambient temperature –30 °C...+80 °C
Hydraulic
Hydraulic fluid Mineral oil based hydraulic oil acc. to DIN/ISO,
other fluids, e.g. environmentally acceptable fluids, on request
Viscosity 10...800 mm2/s permitted range
20...100 mm2/s recommended range
12...2000 mm2/s range permitted for start-up
Temperature of hydraulic fluid In operation +20 °C...+90 °C, for short periods –30 °C...+100 °C
Filtration Oil contamination class 19/16 acc. to ISO/DIS 4406 or class 10 acc. to
NAS 1638, obtained with filter β25 75 1)
Operating pressure P pmax = 250 bar (pump side)
at port A, B pmax = 280 bar (consumer side), in combination with check valves 300 bar
R pmax = 20 bar (return side)
W pmax = 250 bar
Leakage A, B 씮 R Standard: QL = 18 cm3/min
at p = 125 bar, ν = 33 mm2/s with check valve: QL = 2 cm3/min
ϑ = 50 °C with shock valve: QL = 20 cm3/min
Nominal flow see diagram “Operating limits”, page 16
Mechanical
Spool strokes Symbol L20: ± 8 mm
L30, L50: ± 6 mm
L70: ± 6 + 5 mm
Actuating forces < 200 N in spool axis direction
Type of protection IP 69 K, with ES1 IP 54, with ES2 IP 64
1) Retention rate for dirt particles > 25 μm is 1:75, i.e. 98.67 %
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 5/40
Note
Definition of the proportional range: The dither values are to be interpreted as The dither data may need to be examined
0.02 x Qnom to Qnom. Current decay for values for minimum hysteresis. All dither with respect to the given system and, if
the specified dither signals via a spark- data are guide values. necessary, reoptimized.
suppression diode (Uf < 1 V).
6/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Order details
Directional control valves
Qnom
Port Port with AP p
Symbol Comments A B [l/min / bar] Order number
L 20 M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 004
R Y P B without M22 x 1.5 / 1 50 / 3 0 521 608 073
1 0 2
1 0 2
L20 ES1 with switch hub and spare M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 024
R Y P B
parts set E-switch incl.
1 0 2
L20 D1 ES2 without M22 x 1.5 / 1 120 / 8.4 R 917 003 192
R Y P B without M22 x 1.5 / 3 100 / 6 R 917 004 505
1 0 2
L20 D1 N for connection of the subplate without M22 x 1.5 / 3 70 / 3 R 917 005 356
R Y P B with cut-out function
1 0 2
L30 end plate valve unit M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 R 917 004 171
B
A
1 0 2
R Y P
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 7/40
Qnom
Port Port with AP p
Symbol Comments A B [l/min / bar] Order number
L30 A1 B1
A1 B1 p = 300 bar M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 008
R Y P B
A
1 0 2 A1 p = 250 bar M22 x 1.5 / 1 M22 x 1.5 / 1 50 / 3 0 521 608 032
B1 p = 125 bar
L30 A1 B2
B
A1 p = 300 bar M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 009
R Y P
A
1 0 2
A1 p = 90 bar M22 x 1.5 / 1 M22 x 1.5 / 1 50 / 3 0 521 608 043
A
1 0 2
A
1 0 2
L30 E
E p = 120 bar M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 022
R Y P B
A
(100...150 bar)
1 0 2
L30 F
R Y P B F p = 120 bar M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 023
A (100...150 bar)
1 0 2
L30 EF
R Y P B
E F p = 175 bar M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 011
(150...230 bar)
A
1 0 2
E F p = 175 bar M22 x 1.5 / 1 M22 x 1.5 / 1 50 / 3 0 521 608 069
(150...230 bar)
8/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Qnom
Port Port with AP p
Symbol Comments A B [l/min / bar] Order number
L30 H
H p = 125 bar M18 x 1.5 / 3 M18 x 1.5 / 3 50 / 3 R 917 005 357
R Y P B
A
1 0 2
L30 PN pN max = 4 bar *) M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 066
min = 1 bar
R Y P B
*) proportional control
A
1 0 2
L30 ES1 with switch hub and spare M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 025
parts set E-switch incl.
R Y P B
A
1 0 2
R Y P B
A
1 0 2
L30 C1D1 Q2 Q = 34 l/min (2...34) M18 x 1.5 / 1 M18 x 1.5 / 1 34 / 3 0 521 608 071
R Y P B
A
1 0 2
R Y P B
A
1 0 2
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 9/40
Qnom
Port Port with AP p
Symbol Comments A B [l/min / bar] Order number
L50 M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 012
R Y P B
A
1 0 2
L70 RM detent engagement in F M18 x 1.5 / 1 M18 x 1.5 / 1 50 / 3 0 521 608 013
R Y P B
A
1 0 2 F
L30 EM1 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 833
R Y P B
A
b 1 0 2 a
L30 EM2 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 827
R Y P B
A
b 1 0 2 a
L30 C1D1 EM1 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 834
R Y P B
A
b 1 0 2 a
L30 C1D1 EM2 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 7 / 3 0 521 608 841
R Y P B
A
b 1 0 2 a
L30 EF EM2 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 R 917 002 484
R Y P B
E F p = 230 bar
b 1 0 2 a
A (150...230 bar)
10/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Qnom
Port Port with AP p
Symbol Comments A B [l/min / bar] Order number
L30 Q3 EM2 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 859
R Y P B
A
b 1 0 2 a
L50 EM1 24 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 831
R Y P B 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 847
A
b 1 0 2 a
L50 EM2 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 10 / 3 R 917 001 607
R Y P B
A
b 1 0 2 a
L50 C3 D3 EM1 12 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 821
R Y P B
A
b 1 0 2 a
L50 Q3 EM1 12 V Jet M22 x 1.5 / 1 M22 x 1.5 / 1 30 / 3 0 521 608 829
R Y P B
A
b 1 0 2 a
L50.2 Q3 EM1 12 V Jet M22 x 1.5 / 1 M22 x 1.5 / 1 36 / 3 0 521 608 830
R Y P B
A
0 2 a
L50.2 Q3 EM2 24 V Jet M18 x 1.5 / 1 M18 x 1.5 / 1 30 / 3 0 521 608 837
R Y P B
A
0 2 a
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 11/40
Port plates
Δp Qmax Ports
Symbol bar l/min P, R, W, Y, S Order number
A1 R Y P 3 50 P: M 18 x 1.5 1 525 503 390
R: M 22 x 1.5
3 50 P: M 18 x 1.5 1 525 503 524
R: plugged
R P 6 75 P: M 18 x 1.5 1 525 503 528
R: M 22 x 1.5
3 50 P: M 18 x 1.5 1 525 503 503
R: M 22 x 1.5
Y: G1/4
A3 R Y P
3 50 P: M 18 x 1.5 1 525 503 394
R: M 22 x 1.5
W: M 18 x 1.5
R P W
R Y P
A2 R Y P
2.5/7 80 P: M 22 x 1.5 1 525 503 392
R: M 26 x 1.5
3/8.4 90 P: M 22 x 1.5 1 525 503 525
R: M 26 x 1.5
R P 3/11 95 P: M 22 x 1.5 1 525 503 531
R: M 26 x 1.5
6/16 100 P: M 22 x 1.5 1 525 503 505
R: M 26 x 1.5
A4 R Y P
2.5/7 80 P: M 22 x 1.5 1 525 503 396
R: M 26 x 1.5
W: M 22 x 1.5
R W P
End plates
Subplate
R Y P
LS switching valve – Connection of load sensing to return flow. R 917 003 111
Check valve switching valve – prevents / allows relief of check
valve of the bordering directional control valve L20 D1 N.
Manual lowering function.
Accessories
Y2
Shuttle valve for load tap 1 527 419 006
(left-hand version)
Y1
Y
p [bar] Pos. 1
30 1 527 410 084
Shock valve A1 B1
50 1 527 410 082
80 1 527 410 079
90 1 527 410 078
1 100 1 527 410 081
3
120 1 527 410 083
140 1 527 410 077
160 1 527 410 080
180 1 527 410 076
200 1 527 410 070
220 1 527 410 073
250 1 527 410 076
280 1 527 410 072
300 1 527 410 061
Pos. 2
Anticavitation valve A2 B2
1 523 105 083
2
Pos. 3
Spare parts set: locking screw for A1 B1
1 527 010 355
A2 B2
3
p [bar] Pos. 4
Secondary PRV, adjustable E F
25... 60 1 527 410 089
4 60...100 1 527 410 123
100...150 1 527 410 069
150...230 1 527 410 063
WBIHYD
Characteristics, directional control valves
ν = 35 mm2/s, ϑ = 50 °C
) ^
) )
^
K
L
(
9
L^
7 (
7
7 9 7 9
) 9
)
) ( ) ( 7
K^
7 9 7 9
8UVTBSTPUD
14 L30
Δp 6 bar only with L50
L30Q1
Δp switchover L70
Control Δp on pressure compensator 12
control- p [bar]
10
Necessary
L20
8 s = 8 mm
(spool
travel)
6
0
Operating limits 0 20 40 60 80 100 120
direct operated electromagnetic actuation Qnom [l/min]
WBIHYD
1 Braking load,
i.e. lifting or pressing at control Δp = 3 bar
2 Braking load,
i.e. lifting or pressing at control Δp = 8.4 bar
3 Driving load,
i.e. lowering or pulling,
A씮R
4 Driving load,
i.e. lowering or pulling,
B씮R
8UVTBSTPUD
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 15/40
90
Flow versus spool travel
(characteristic curve) 80
p = 6 bar
70
60
50
p = 3 bar
40
30
20
10
8 6 4 2 0 2 4 6 8
s [mm]
40 2,4
Qnom [l/min]
Flow Q and solenoid current I
versus spool travel
IM [A]
(characteristic curve)
30 1,8
20 1,2
10 0,6
0
0 1 2 3 [mm] Valve strok
s [mm]
16/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
12
10
rt
6 ring, resso
Feder, sp
p 4 bar
4 p 3 bar
R P p 2,5 bar
0
0 10 20 30 40 50 60 70 80
Qnom [l/min]
240
220
200
180
160
R
P 140
120
0
0 10 20 30 40 50 60 70 80
Qnom [l/min]
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 17/40
Dimensions
Ø 16.4
8D11
83.7 R
95
R R R
41.5
Y
P
16
128 34 8
193
8h11
21.5
40
60.8
100.2
112.4 7.9
28.5
70
Operating element
16.6°
16
.6
13.5° °
211
16.5
60.5
°
16.5°
178
18/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Dimensions
RM F 2 0 1 Pos
566
R R R
Y
P
248
ES 1
B A
R R R
Y
P
max 247
ES 2 B A
A
R
R R R
Y P
128.3 34 40
214.9
248.9
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 19/40
Dimensions
34.3
A
R
72.2
R R R
Y
P
13
259.9
R R R
Y
P
232.8 81.5
314.3
20/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Dimensions
R R R
Y
P
194
Directional control valve with auxiliary function
C1 D1 109
2 0 1 Pos
52 66
B A
R R R
Y
P
E F A
R R R
Y
P
201.27
B A
R R R
Y
P
128.3 34 40
158.6
192.6
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 21/40
Dimensions
2-pin mating
Directional control valve with auxiliary function connector 2-polig
Gegenstecker
C3 D3 EM
143.6
3.6
108.5
41.5
229.3 78.5
311.6
Q1
A
R
96.7
R R R
Y
P
17
158.3
193
Q3
A
R
130.6
R R R
41.5
13.5
Y
P
34
34
158.3 38
193
22/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Dimensions
Port plates A1 A2
Left-hand version
P
M R1
118
96.5
58
Y
min.11
16.5
M8
41.5
M8 (3x)
(2x)
13±0.2
10 21 20
40 68
128
20
98
94 17
140
112.4 7.9
3.7
6.5
4
70
RC
90.7
70
RB RA RD
8.2
51.5
8.5 (2x)
Y P
13±0.2
72.5
112.4 19
M8
94 11tief (2x)
11deep (2x)
34.5
28
18.5
14
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 23/40
Dimensions
122.5
105
147.3 19.5
1.5
179.4 (2x) 40
208.6 (2x)
103.4
24/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Dimensions
118
96.5
M8 M8
min.11
30 30 40 (2x)
+2
4x40+24=184 -3
R
193
100.2
109
60.8
52
28.5
P
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 25/40
LS circuit examples
Standard control block with fixed pump Standard control block with variable pump
R Y P R Y P
R Y P B R Y P B
A A
1 0 2 1 0 2
R Y P B R Y P B
A A
1 0 2 1 0 2 F
R Y P B R Y P B
A A
1 0 2 1 0 2
R Y P B R Y P B
A
1 0 2 1 0 2
R Y P R Y P
R P R Y P
26/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
R Y P
R Y P B
Double acting valve for the auxiliary function
A
1 0 2
R Y P B
A
Double-acting valve with integrated pilot pressure insert
1 0 2 for a continuous transition from pushing load to pulling load
during tilting.
R Y P B
Single-acting valve with integrated check valve for leak-free
A
1 0 2
load holding with the lift/lower function
R Y P Subplate with LS switching valve for connection of load sensing to check flow,
check valve switching valve for relief of check valve of bordering directional control
valve L20 D1 N and manual lowering function.
R N P
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 27/40
Open center pump control, fine-control residual flow and pri- Connection:
mary PRV function via pressure compensator in block 1, i.e. Control line Y via port plate from block 2 to end plate block 1.
block II does not require a pressure compensator of its own. P and R via pipeline with branch before block 1.
Block 1 Block 2
R Y P R Y P
R Y P B R Y P B
R Y P R Y P
R P R Y P
SB12 – EM
Return port in the end plate at port plate with Q greater than Return port only in end plate up to
30 l/min. Q = 30 l/min.
Port plate symb. A3/A4 not usable. Port plate symb. A3/A4 not usable.
s s
R Y P R Y P
R Y P B R Y P B
A A
R Y P R Y P
R P R P
28/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
A
1 0 2
R Y P
R Y P B
A
1 0 2
R Y P
R N P R P
R Y P R Y P
R Y P B R Y P B
A A
R Y P R Y P
R N P R P
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 29/40
Functional description
“Load sensing” principle and converted to heat. With negative switching overlap
Load sensing, i.e. the variable load pressure, is detected and of the open center pump control, the excess pressure can be
fed to a pressure compensator or a pump controller. This prin- reduced.
ciple offers the following advantages over other systems:
2.2 Fixed pump with “load sensing”
1. Load-independent flow control The excess flow is not removed by means of the maximum
The pressure differential Δp at the variable throttle cross- pressure valve, but instead via a parallel pressure compensa-
section of the directional control valve is kept constant. As tor. This does not open at p1, but instead at the measured load
a result, load fluctuations are compensated and the flow or pressure p2 plus the spring precharge pressure, which deter-
cylinder speed is kept constant. This only applies for the mines the pressure difference Δp at the throttle. This configura-
cylinder with the highest load pressure which is accessed via tion corresponds to a 3-way flow control valve and ensures not
shuttle valves. only improved power balance, but also a consumer flow which
is independent of load fluctuations.
2. Power drops in the fine control range
Flow control through throttling inevitably has losses. These 2.3 Variable pump with “load sensing”
losses are minimized through the “load sensing” principle. The pressure compensator is a component of the pump con-
A comparison with other systems illustrates this advantage. trol system and controls the delivery according to the opening
cross section of the throttle. This adaptation occurs when the
2.1 Fixed pump with open center pump control load pressure is detected, i.e. neither excess pressure nor
The excess flow is removed via the pressure-relief valve. excess delivery occurs. Only the pressure difference Δp at the
Because its set value p1 exceeds the load pressure p2, there throttle, determined by the spring of the pressure compensator,
is excess pressure. Thus, there is excess power which is still generates a slight dissipation power. This system requires
shared between the throttle and the pressure-relief valve a variable pump with corresponding controller.
OC system LS system
F variable
variabel F variable
variabel
P2 Q2 Q2
P2
N
p p = const
variabel
variable
N P p p p
P2 p
P1 Q2 p
Q = const
Q Q
30/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
p
P1
P2 Q2
N
p P2
N P
P1
QPU
Q
Q2 QPU
p
P1
Q2
P2
p
p P2
P
P2 p
QPU
Q
Q2 QPU
p
Q2 P1
P2
p
p
P P2
P2 p
p
Q
Q2 QPUmax.
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 31/40
3. Power drops in the open center pump control For LS systems, the open center pump control occurs with
In standard systems with open center pump control by means minimal pressure directly in the port plate. With the Δp switch-
of the valve block, the open center pump control pressure is over (optional), this pressure can also be minimized.
dependent on the number of directional control valve segments.
OC system LS system
p p
4 4
3
3
2
1 2
1
Q Q
4. Actuation force at the valve spool hydraulic power. For LS systems, the actuating forces are
In standard systems, the flow forces, and thus the actua- smaller and remain constant.
ting forces at the valve spool, increase with the transmitted
OC system LS system
F F
p,Q p,Q
5. Control characteristic tion to the open center pump control must be more strongly
With conventional systems, the flow is load dependent. More- throttled. LS systems are characterized by a control charac-
over, the connection to the consumer at higher load pressures teristic which is independent of load pressure.
is opened only with a larger spool travel since the connec-
OC system LS system
Q Q
P1 ... P2
N
P1 P1, P2, P3
P2 N T
S
P3 P
P1 P2 P3 S S
32/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Port plate 2 1
Basic version p = 3 bar P
In addition to the infeed and return ports of the valve block for
use with fixed pumps, the port plate contains a pressure com-
pensator as well as an adjustable pressure-relief valve. The R P
pressure compensator performs 3 functions:
• In combination with the instantaneous throttle cross sections R
R
at the directional-control-valve pilot spools, it functions as
a 3-way flow regulator. The load pressure acts on the spring
side of the pressure compensator via control line Y. The P
spring determines the pressure differential at the throttle
cross sections of the directional control valves. This is held
constant by the pressure compensator (p = 3 bar).
3 4
• When the control line is depressurized (all directional control
valves in the home position), the pressure compensator
opens due to the effect of the inflow pressure and releases
the open center pump control. R Y P
• Together with the adjustable pilot valve, the pressure com-
pensator forms the main level of a pilot controlled pressure-
relief valve for ensuring the maximum operating pressure.
R P
Port plate
R Y P
with p switchover
2.5 bar/7 bar
Q2 = Q1
p2
p1
= 50 = 80 l/min
7
Q
Q2 80 p p==7 7bar
bar
2.5
mit
with pp switchover
Umschaltung
The increased pressure differential does, however, mean
increased power drops, which are to be avoided particularly
during open center pump control. 50 p p==3 3bar
bar
Grundausführung
Basic version
A switchover from p = 2.5 bar during open center pump
control to p = 7 bar with opened directional control valves
is realized with a special port plate. The switchover occurs via
a switching valve which is integrated in the pressure compen-
sator.
S
Q p
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 33/40
Basic version B A 3
The basic version shown here is a double-acting directional
control valve with 2 service line ports A and B. The valve spool 2
2 Return spring
3 Opening cross section
4 Shuttle valve R Y P B
5 Check valve 1 0 2
A
Ports
P Pump
A, B Consumers
R Tank
Y Load Sensing (LS)
Directional control valve – actuation types, auxiliary functions in the main axis
Mechanical actuation RM
Characteristic UA
following ideal zero-point [xUS]
calibration on the valve
Sensitivity: ± 6 %
Linearity: ± 1.5 % 75%
Measuring span
Messspanne
25%
-s +s
100% 100%
Measuring
Messwegpath
Pneumatic actuation PN
X1 X2
Auxiliary actuation with respect to hand lever.
Actuation via pneumatic switching valve.
pst min. 1 bar
pst max. 4 bar
X1 X2
Shock valves A1 B1 A2 B2
p [bar]
p [bar]
320
16
300
280 14
260
12
240
220 10
200 8
180 A2 B2
160 6
140
4
120
100 2
80
60 0 10 20 30 40 50 60
QQ nom [l/min]
Nenn
40
20
0
0 10 20 30 40 50 60 70 80
QQ [l/min]
nom [l/min]
Nenn
36/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
B A R Y P B
Pilot pressure inserts G H
A
1 0 2
R P
t
ns
A
compensator of the port plate as a
co
1 0 2
3-way flow control valve. During parallel
p=
operation, the highest load pressure is
reported to the pressure compensator. R Y P
May either be fixed or adjustable.
Q
2-way flow control valve in the inflow Q2
B Qmax
For limiting Qmax in parallel operation. A
1 0 2
Also effective if the load pressure of the
other consumers is higher.
S
38/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
A
in the inflow Q3 1 0 2
Subplate
R Y P
Subplate with LS switching valve for connection
of load sensing to return flow, check valve
switching valve for relief of check valve of
bordering directional control valve L20 D1 N
and manual lowering function.
SB12 RE 64 386/02.12 Hydraulics Bosch Rexroth AG 39/40
Notes
40/40 Bosch Rexroth AG Hydraulics SB12 RE 64 386/02.12
Notes
Bosch Rexroth AG This document, as well as the data, specifications and other information
Mobile Controls set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
Robert-Bosch-Straße 2 be reproduced or given to third parties without its consent.
D-71701 Schwieberdingen The data specified above only serve to describe the product. No state-
Fax +49 (0) 711-811 26 78 01 ments concerning a certain condition or suitability for a certain application
info.brh-stf@boschrexroth.de can be derived from our information. The information given does not release
www.boschrexroth.com/brm the user from the obligation of own judgment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.