COM Port Pin COM1 COM2 COM1 COM2 COM1 COM2 Wiring:
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422
(4) Mounting dimensions
Type Wire gauge (AWG) Stripped length Torque
1 - - D+ - - TXD+ Solid 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
DOP-103BQ
2 RXD - - - RXD -
Stranded 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
3 TXD - - - TXD -
4 - D+ - D+ - RXD+
Please refer to the following diagram when wiring the power connector. The temperature
5 GND GND GND rating of the cable must be greater than 75oC (167oF).
6 - - D- - - TXD-
7 RTS - - - RTS -
8 CTS - - - CTS -
9 - D- - D- - RXD-
Model DOP-103BQ
Backlight LED backlight (half-life under room temperature 25oC > 20,000 hours) *1
SD N/A
Calendar Built-in
Note:
1. The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the
maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the
room temperature of 25oC with ambient humidity.
2. The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
3. The HMI power consumption is the power consumed when the HMI is not connecting with other
peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power
supply is 1.5 to 2 times of the specified power consumption.
4. Isolated power supply is recommended.
5. For DOPSoft programming software for DOP-100 series and the user manual, you can download them
at http://www.delta.com.tw/ia.
6. DOP-100 series can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.