Exhibit 8 Manual ‐ Confidential 

Radio Frequency Electromagnetic Exposure


CDMA/GSM/LTE/WCDMA

Safety Information

5/124 46-LZA 701 6001 Uen Rev CX


Radio Frequency Electromagnetic Exposure

Copyright

© Copyright Ericsson AB 2009-2018. All rights reserved.

Disclaimer

No part of this document may be reproduced in any form without the written
permission of the copyright owner.

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use of
this document.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 2 (50)
Radio Frequency Electromagnetic Exposure

Contents

1 Introduction...............................................................................4

2 Compliance Boundaries for Electromagnetic Exposure ......4


2.1 Macro RBS .................................................................................4
2.2 Micro RBS ................................................................................25
2.3 Pico RBS ..................................................................................39
2.4 Radio Dot System.....................................................................46

References.................................................................................................51

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 3 (50)
Radio Frequency Electromagnetic Exposure

1 Introduction
This document provides information on Radio Frequency (RF)
Electromagnetic Field (EMF) exposure from antennas either integrated in or
connected to a radio base station (RBS) or a radio unit in the RBS 6000
family.

2 Compliance Boundaries for


Electromagnetic Exposure
The compliance boundary defines the minimum separations that should be
kept between the antenna and a person to ensure that the ICNIRP [1], FCC [2]
and Innovation, Science and Economic Development Canada [3] RF exposure
limits are not exceeded.

Ericsson has performed advanced numerical or experimental RF exposure


assessments in accordance with European standards [4], [5] in order to
determine compliance boundaries for minimum and maximum power
configurations of the RBS product with recommended antennas. The resulting
dimensions, in meters, for a compliance boundary for both general public and
occupational exposure are shown in the sections below for macro, micro, and
pico RBS products as well as for the radio dot system.

The compliance boundary is defined as a cylinder or as a box surrounding the


antenna/equipment. For configurations employing sector coverage antennas,
the antenna/equipment is not located at the center of the compliance
boundary. Instead it is located almost at the edge, facing towards the center of
the cylinder/box. Figures illustrating the employed compliance boundaries for
different configurations are provided in the subsections below.

2.1 Macro RBS


For the macro case, both cylindrical and box-shaped compliance boundaries
are used as illustrated in Figure 1 and Figure 2. Box-shaped compliance
boundaries are used for AIR configurations and for multicolumn MIMO
configurations.

The distance between the back of the antenna and the cylinder/box is the
"Distance behind antenna". The height of the cylinder/box is the antenna
height plus a certain, equal distance above and below the antenna. For a box-
shaped compliance boundary the ‘Width’ represents the width of the box.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 4 (50)
Radio Frequency Electromagnetic Exposure

Figure 1. Cylindrical Compliance Boundary.

Figure 2. Box-shaped Compliance Boundary.

The resulting compliance boundary dimensions, in meters, for both general


public and occupational exposure are shown in Table 1-1, Table 1-2, and
Table 1-3 for RU (internal radio unit), Tables 2-1, 2-2, 2-3, 2-4, 2-5, 2-6 and
2-7 for RRU (external radio unit), and Tables 3-1 and 3-2 for AIR (antenna
integrated radio unit).

It should be noted that Table 1 through Table 3 show examples for specified
typical antennas and for minimum and maximum power levels, including the
power tolerances and assumed transmission losses. As the antenna field
distributions will differ for other antennas and power levels, calculations or
measurements may be necessary to establish the compliance boundary for
other configurations chosen by the customer. Other calculations or
measurements may also be required if exposure limits other than [1] or [2] are
specified in national regulations. For further information on RF exposure
assessment methods, see [6].

The expanded uncertainty (k=2) is 2.3 dB for the underlying calculations of


the power density used for assessment of the compliance boundary
dimensions listed in Table 1 through Table 3.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 5 (50)
Radio Frequency Electromagnetic Exposure

Characteristics of the antennas recommended and tested for macro RBS 6000
configurations are listed in Table 4.

The total powers fed to the antennas (including tolerance and assumed
transmission loss) are given in Table 5 for using RU, Table 6-1, Table 6-2 and
Table 6-3 for using RRU and Table 7-1 and 7-2 for using AIR.

Table 1-1 Cylindrical Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Powers using RU (Internal Radio Unit) with 0.6 dB
Tolerance and Assumed 3 dB Transmission Loss.
Dimensions of the cylindrical compliance boundary (m)
Mode and output power for RU (internal radio unit) Distance behind
Diameter Height
antenna
Nominal output power
Band Standard1 GP O GP O GP O
from the radio
20 W 0.9 0.4 2.6 2.6 <0.1 <0.1
B0 (900P) G/W/L
100 W 5.4 1.0 2.7 2.6 <0.1 <0.1
20 W 0.9 0.3 1.4 1.4 <0.1 <0.1
B1 (2100) W/L
100 W 4.8 0.9 1.6 1.4 <0.1 <0.1
G/W/L/C 20 W 0.9 0.3 1.4 1.4 <0.1 <0.1
B2 (1900) C 80 W 4.1 0.8 1.5 1.4 <0.1 <0.1
G/W/L 100 W 4.9 0.9 1.6 1.4 <0.1 <0.1
20 W 1.1 0.3 1.4 1.4 <0.1 <0.1
B3 (1800) G/W/L
100 W 5.0 1.1 1.5 1.4 <0.1 <0.1
20 W 0.9 0.3 1.4 1.4 <0.1 <0.1
B4 (17/2100) W/L/C
80 W 4.0 0.8 1.6 1.4 <0.1 <0.1
G/W/L/C 20 W 2.5 0.6 1.4 1.3 <0.1 <0.1
B5 (850)
100 W 5.7 2.5 1.6 1.4 <0.1 <0.1
20 W 1.0 0.3 1.4 1.4 <0.1 <0.1
B7 (2600) L
60 W 3.2 0.6 1.4 1.4 <0.1 <0.1
20 W 2.4 0.6 1.3 1.3 <0.1 <0.1
W/L
100 W 5.6 2.5 1.6 1.3 <0.1 <0.1
B8 (900E)
20 W 0.9 0.4 2.6 2.6 <0.1 <0.1
G
100 W 5.4 1.0 2.7 2.6 <0.1 <0.1
20 W 1.5 0.4 1.5 1.4 <0.1 <0.1
B11 (1500) W
60 W 4.6 1.0 1.6 1.4 <0.1 <0.1
20 W 2.7 0.6 2.0 1.9 <0.1 <0.1
B12 (70012) L
60 W 5.7 1.5 2.2 2.0 <0.1 <0.1
20 W 2.7 0.6 2.0 1.9 <0.1 <0.1
B13 (70013) L
60 W 5.6 1.5 2.2 2.0 <0.1 <0.1
20 W 2.6 0.6 2.0 1.9 <0.1 <0.1
B14 (70014) L
60 W 5.6 1.4 2.2 2.0 <0.1 <0.1
20 W 2.6 0.7 1.4 1.3 <0.1 <0.1
B20 (800DD) L
80 W 5.2 2.3 1.6 1.3 <0.1 <0.1
20 W 2.5 0.6 1.4 1.4 <0.1 <0.1
B28 (700) L
100 W 5.7 2.5 2.0 1.4 <0.1 <0.1

1The standards are abbreviated in the tables of this document: G/W/L/C/VTF =


GSM/WCDMA/LTE/CDMA/Verizon Technical Forum.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 6 (50)
Radio Frequency Electromagnetic Exposure

Table 1-2 Box Shaped Compliance Boundary Dimensions for General Public
(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Power Configurations with MIMO using RU (Internal Radio
Unit) with 0.6 dB Tolerance and Assumed 3 dB Transmission
Loss.
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for RU (internal radio unit) Distance in
using MIMO antenna and 0.6 dB tolerance Distance
front Width Height
behind antenna
of antenna
Nominal
Number of output power
Band Standard GP O GP O GP O GP O
Tx/Rx from
the radio
B13 (700) L 4 240 W 16 7.1 12.6 5.4 3.2 2.2 0.1 0.1

Table 1-3 Box Shaped Compliance Boundary Dimensions for General Public
(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Power Configurations with MIMO using more than one RU
(Internal Radio Unit) with 0.6 dB Tolerance and Assumed 3 dB
Transmission Loss.
Dimensions of the box-shaped compliance
boundary (m)
Mode and output power for configurations with more than one RRU (external
Distance Distance
radio unit) with 0.6 dB tolerance and 0.5 dB transmission loss
in front Width Height behind
of antenna antenna
Nominal output IEC 62232
Product name Band Standard power from the installation GP O GP O GP O GP O
radios class
4 x RUS 01 B4 (2100) L 4 x 60 W E+ 11.7 4.8 9.1 3.2 3.3 1.5 <0.1 <0.1
4 x RUS 02 B2 (1900) L 4 x 80 W E+ 12.6 5.4 10.1 4.5 3.7 1.7 <0.1 <0.1
4 x RUS 02 B5 (800) L 4 x 100 W E+ 17.9 8.0 13.8 6.2 3.2 2.0 <0.2 <0.1

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 7 (50)
Radio Frequency Electromagnetic Exposure

Table 2-1 Cylindrical Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Powers using RRU (External Radio Unit) with 0.6 dB
Tolerance and Assumed 0.5 dB Transmission Loss.
Dimensions of the cylindrical compliance boundary (m)
Mode and output power for RRU (external radio unit) Distance behind
Diameter Height
antenna
Nominal output power
Band Standard GP O GP O GP O
from the radio
20 W 1.6 0.4 2.6 2.6 <0.1 <0.1
B0 (900P) G/W/L
120 W 9.8 2.0 2.9 2.6 <0.1 <0.1
20 W 1.5 0.4 1.4 1.4 <0.1 <0.1
B1 (2100)2 W/L
120 W 9.3 2.3 1.8 1.5 <0.1 <0.1
40 W 4.3 0.9 1.5 1.5 <0.1 <0.1
B1 (2100)3 W/L
160 W 9.4 3.7 1.6 1.5 <0.1 <0.1
20 W 1.7 0.4 1.4 1.4 <0.1 <0.1
B2 (1900) G/W/L
160 W 8.9 2.3 1.7 1.5 <0.1 <0.1
20 W 1.8 0.4 1.4 1.4 <0.1 <0.1
B3 (1800)4 G/W/L
160 W 9.3 3.5 1.7 1.5 <0.1 <0.1
40 W 4.3 1.0 1.5 1.5 <0.1 <0.1
B3 (1800)5 G/L
160 W 9.1 3.9 1.6 1.5 <0.1 <0.1
B1 (2100) / B3
W, G/L 160 W 9.2 3.8 1.6 1.5 <0.1 <0.1
(1800)6
20 W 1.5 0.4 1.4 1.4 <0.1 <0.1
B4 (17/2100) W/L/C
120 W 7.8 2.0 1.7 1.4 <0.1 <0.1
20 W 3.4 1.2 1.4 1.3 <0.1 <0.1
B5 (850) G/W/L/C
160 W 9.7 4.4 2.0 1.5 <0.2 <0.1
20 W 1.9 0.4 1.4 1.4 <0.1 <0.1
B7 (2600) L
160 W7 10.3 3.7 1.6 1.5 <0.2 <0.1
20 W 3.3 1.2 1.4 1.3 <0.1 <0.1
G/W/L8
160 W 9.5 4.3 2.0 1.4 <0.1 <0.1
B8 (900E)
20 W 1.6 0.4 2.6 2.6 <0.1 <0.1
G9
120 W 9.9 2.0 2.9 2.6 <0.1 <0.1
20 W 1.8 0.4 1.4 1.4 <0.1 <0.1
B9 (17/1800) W/L
60 W 5.2 1.2 1.6 1.4 <0.1 <0.1
20 W 3.0 0.6 1.6 1.4 <0.1 <0.1
B11 (1500) W/L
80 W 7.4 1.9 1.8 1.6 <0.1 <0.1
20 W 4.2 0.9 2.0 1.9 <0.1 <0.1
B12 (70012) L
80 W 9.0 3.8 2.4 2.0 <0.1 <0.1
20 W 4.1 0.9 2.0 1.9 <0.1 <0.1
B13 (70013) L
120 W 10.8 4.7 2.5 2.1 <0.1 <0.1
B20 (800DD) L 20 W 3.5 1.4 1.4 1.3 <0.1 <0.1

2 This row shows results for the KRE 101 1985/1 antenna
3 This row shows results for the KRE 101 2085/1 v02 antenna.
4 This row shows results for the KRE 101 1985/1 antenna
5 This row shows results for the KRE 101 2085/1 v02 antenna.
6 KRE 101 2085/1 v02 transmits simultaneously on B1 and B3 with the power divided equally among the

two bands
7 This row shows results for the KRE 101 2085/1 v02 antenna.
8 This row shows the compliance boundary obtained with the X-pol macro RBS directional antenna

(KRE 101 2021/1).


9 This row shows the compliance boundary obtained with the X-pol macro RBS directional antenna

(KRE 101 2057/1).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 8 (50)
Radio Frequency Electromagnetic Exposure

Dimensions of the cylindrical compliance boundary (m)


Mode and output power for RRU (external radio unit) Distance behind
Diameter Height
antenna
Nominal output power
Band Standard GP O GP O GP O
from the radio
80 W 7.0 3.2 1.8 1.4 <0.1 <0.1
20 W 1.7 0.4 1.4 1.4 <0.1 <0.1
B25 (1900G) L/C
80 W 6.0 1.3 1.6 1.4 <0.1 <0.1
B25 (1900G) W/L 160 W 8.9 2.3 1.7 1.5 <0.1 <0.1
20 W 3.4 1.2 1.4 1.3 <0.1 <0.1
B26 (850) L/C
80 W 6.8 3.1 1.7 1.4 <0.1 <0.1
20 W 3.4 1.2 1.6 1.4 <0.1 <0.1
B28 (700) L 80 W 6.8 3.0 2.2 1.5 <0.1 <0.1
160 W 9.6 4.4 2.9 1.8 0.2 <0.1
20 W 3.4 1.2 1.6 1.4 <0.1 <0.1
B29 (700) L
80 W 7.0 3.0 2.3 1.6 <0.1 <0.1
20 W 4.7 1.2 2.3 2.0 <0.1 <0.1
B31 (450) L
80 W 9.5 4.2 2.9 2.2 <0.1 <0.1
20 W 3.0 0.6 1.6 1.4 <0.1 <0.1
B32 (1500) L
160 W 10.6 4.5 2.0 1.6 <0.1 <0.1
20 W 1.9 0.4 1.4 1.4 <0.1 <0.1
B38 (2600) L
80 W 6.4 1.4 1.4 1.4 <0.1 <0.1
20 W 1.8 0.4 1.4 1.4 <0.1 <0.1
B39 (1900) L
80 W 6.1 1.3 1.6 1.4 <0.1 <0.1
20 W 1.6 0.4 1.4 1.4 <0.1 <0.1
B40 (2300) L
100 W 7.0 1.5 1.5 1.4 <0.1 <0.1
20 W 1.9 0.4 1.4 1.4 <0.1 <0.1
B41 (2500) L
120 W 8.0 2.1 1.4 1.4 <0.1 <0.1
20 W 3.3 1.6 1.2 1.2 <0.1 <0.1
B42 (3500) L
80 W 6.4 3.0 1.2 1.2 <0.1 <0.1
20 W 1.5 0.4 1.4 1.4 <0.1 <0.1
B66 (17/2100) W/L
160 W 9.2 2.3 1.8 1.5 0.1 <0.1

Table 2-2 Cylindrical Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Powers using RRU (External Radio Unit) operating on
multiple bands with 0.6 dB Tolerance and Assumed 0.5 dB
Transmission Loss.
Dimensions of the cylindrical compliance boundary (m)
Mode and output power for RRU (external radio unit) Distance behind
Diameter Height
antenna
Nominal output power
Band Standard GP O GP O GP O
from the radio
10 W 2.3 0.6 1.4 1.4 <0.1 <0.1
B18 / B2810 L
100 W 7.6 3.4 2.2 1.5 <0.1 <0.1
2W 0.3 0.2 1.4 1.4 <0.1 <0.1
B311 L
20 W 1.8 0.4 1.4 1.4 <0.1 <0.1

10 This row shows the result for RRU 22F2 with operation on B18 and B28 with power ratios of 60 % and
40 % on these bands, respectively.
11 This row shows the results for RRU 22F1.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 9 (50)
Radio Frequency Electromagnetic Exposure

Table 2-3 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Power Configurations with MIMO Multi-Column Antennas using
RRU (External Radio Unit) with 1 dB Tolerance and Assumed 0.5
dB Transmission Loss.
Mode and output power for RRU Dimensions of the box-shaped compliance boundary (m)
(external radio unit) using MIMO antenna Distance in
and 1 dB tolerance Distance
front Width Height
behind antenna
of antenna
Nominal
Number output power
Band Standard GP O GP O GP O GP O
of Tx/Rx from
the radio
B38 40 W 11.2 2.7 9.4 2.0 2.1 1.6 <0.1 <0.1
L 8
(2600) 120 W 20.2 8.3 17.1 6.5 2.8 1.8 0.2 <0.1
B39 40 W 7.8 2.9 9.0 2.2 1.6 1.4 <0.1 <0.1
L 8
(1900) 80 W 11.2 4.8 13.2 5.2 1.9 1.4 0.3 <0.1
B41 40 W 11.2 2.7 9.4 2.0 2.1 1.6 <0.1 <0.1
L 8
(2500) 240 W 28.8 12.4 24.4 10.1 3.6 2.1 0.2 <0.1

Table 2-4 Cylindrical Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Power Configurations with RRU (External Radio Unit) with 1 dB
Tolerance and Assumed 0.5 dB Transmission Loss.
Dimensions of the cylindrical compliance boundary (m)
Mode and output power for RRU (external radio unit)
with 1 dB tolerance Distance behind
Diameter Height
antenna
Nominal output power
Band Standard GP O GP O GP O
from the radio
20 W 2.0 0.5 1.4 1.4 <0.1 <0.1
B38 (2600) L
80 W 6.7 1.5 1.4 1.4 <0.1 <0.1
20 W 1.6 0.4 1.4 1.4 <0.1 <0.1
B40 (2300) L
40 W 3.9 0.7 1.4 1.4 <0.1 <0.1

Table 2-5 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Power Configurations with MIMO Multi-Column Antennas using
RRU (External Radio Unit) with 0.6 dB Tolerance and Assumed
0.5 dB Transmission Loss.
Mode and output power for RRU (external radio Dimensions of the box-shaped compliance boundary (m)
unit) using MIMO antenna and 0.6 dB tolerance Distance in Distance
front of Width Height behind
antenna antenna
Nominal
Number output power
Band Standard GP O GP O GP O GP O
of Tx/Rx from the
radio
B1 (2100) W/L 4 160 W 12.7 5.3 9.9 3.6 3.5 1.6 <0.1 <0.1
B1 (2100) /
L/W/G 4 160 W 12.1 5.0 9.1 3.0 1.8 1.5 <0.1 <0.1
B3 (1800)12
40 W 7.2 1.4 4.6 0.7 1.6 1.5 <0.1 <0.1
B2 (1900) G/W/L 4
160 W 15.4 6.4 11.7 3.8 2.0 1.6 0.1 <0.1
12 KREB2101 2294/1 transmits simultaneously on B1 and B3 with the power divided equally among the two
(1900) /
bandsB66A (2100) L 8 320 W 17.2 7.4 13.5 6.1 4.2 1.9 0.3 0.1
13
13 Two KRE 101 2294/1 (4 Tx) antennas transmit on B2 (4 Tx) and B66A (4 Tx) with the power distributed
B2 (1900) /
equally among
B66A (2100)the Ltwo bands 8 320 W 17.5 7.6 13.7 6.2 4.6 2.1 0.3 0.1
14 Two14KRE 101 2294/1 (4 Tx) antennas transmit on B2 (4 Tx) and B66A (4 Tx) with power distributed as

25 % and 75 % over the two bands, respectively.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 10 (50)
Radio Frequency Electromagnetic Exposure

B2 (1900) /
B66A (2100) L 4 280 W 11.2 4.7 9.2 3.2 3.0 1.5 0.3 0.1
15

L 4 20 W 4.6 0.8 2.3 0.4 1.6 1.5 <0.1 <0.1


B3 (1800) 40 W 7.1 1.7 4.9 0.9 1.6 1.5 <0.1 <0.1
G/L 4
160 W 15.0 6.4 11.6 4.2 2.1 1.6 <0.1 <0.1
B3 (1800)16 G/L 4 160 W 12.1 5.1 9.6 4.3 3.8 2.0 <0.1 <0.1
40 W 7.3 1.4 5.0 0.8 1.5 1.5 <0.1 <0.1
B4 (17/2100) W/L 4
160 W 15.3 6.3 11.7 4.1 1.9 1.5 0.1 <0.1
B5 (850) W/L 4 160 W 15.2 6.8 11.6 5.2 2.7 2.0 <0.1 <0.1
40 W 7.9 1.1 4.2 0.7 1.6 1.5 <0.1 <0.1
B7 (2600) L 4
160 W 17.3 6.7 13.1 2.9 2.1 1.6 0.3 <0.1
B8 (900E) G/W/L 4 160 W 14.7 6.6 11.5 5.2 2.5 2.0 <0.1 <0.1
B14 (700) L 4 160 W 17.4 7.8 13.6 5.9 3.3 2.3 0.1 0.1
40 W 5.6 1.3 3.8 0.9 2.0 1.8 <0.1 <0.1
B25 (1900G) L/C 4
160 W 13.6 4.5 11.8 2.9 3.4 1.9 <0.2 <0.1
25 W 5.9 0.9 2.9 0.5 1.6 1.5 <0.1 <0.1
B30 (2300) L 4
100 W 13.7 4.7 9.4 2.1 1.7 1.5 <0.1 <0.1
40 W 7.9 1.1 4.5 0.7 1.6 1.5 <0.1 <0.1
B38 (2600) L 4
160 W 17.3 6.7 12.0 3.5 2.0 1.6 <0.3 <0.1
20 W 4.8 0.6 2.2 0.4 1.6 1.5 <0.1 <0.1
B40 (2300) L 4
160 W 17.4 7.0 12.2 3.9 1.9 1.6 <0.1 <0.1
20 W 3.2 0.6 1.9 0.4 1.6 1.5 <0.1 <0.1
B41 (2500) L 4
160 W 17.3 6.7 12.0 3.5 2.0 1.6 <0.3 <0.1
40 W 10.6 2.5 8.8 1.7 1.9 1.5 <0.1 <0.1
B41 (2500) L 8
160 W 22.1 9.2 19.2 7.5 3.0 1.8 <0.2 <0.1
40 W 7.3 1.4 5.0 0.8 1.5 1.5 <0.1 <0.1
B66 (17/2100) W/L 4
240 W 15.3 6.6 12.2 5.5 4.4 2.0 <0.1 <0.1
B71 (600) L 4 160 W 17.9 7.8 16.3 6.3 3.6 2.7 <0.3 <0.1

15 KRE 101 2294/1 (4 Tx) antenna transmits on B2 (2 Tx) and B66A (2 Tx) with power distributed as 43 %
and 57 % over the two bands, respectively.
16 This row shows the compliance boundary obtained with the X-pol macro RBS directional antenna

(KRE 101 2294/1).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 11 (50)
Radio Frequency Electromagnetic Exposure

Table 2-6 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Power Configurations with MIMO Multi-Column Antennas using
RRU (External Radio Unit) with time-division duplexing (TDD),
0.6 dB Tolerance and Assumed 0.5 dB Transmission Loss.
Dimensions of the box-shaped compliance
boundary (m)
Mode and output power for RRU (external radio unit) using MIMO antenna Distance
Distance
and 0.6 dB tolerance in front
Width Height behind
of
antenna
antenna
Nominal output
IEC 62232
Band Standard power from the TDD factor GP O GP O GP O GP O
installation class
radio

B4017 L 4 x 40 W E+ 0.74 11.0 4.5 8.0 2.8 3.8 1.7 <0.1 <0.1

Table 2-7 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and
MaximumPower Configurations with MIMO Multi-Column Antennas
using more than one RRU (External Radio Unit) with 0.6 dB
Tolerance and Assumed 0.5 dB Transmission Loss.
Dimensions of the box-shaped compliance
boundary (m)
Mode and output power for configurations with more than one RRU (external
Distance Distance
radio unit) with 0.6 dB tolerance and 0.5 dB transmission loss
in front Width Height behind
of antenna antenna
Nominal output IEC 62232
Product name Band Standard power from the installation GP O GP O GP O GP O
radios class
4 x 30 W E+ 10.3 4.3 8.3 2.9 3.1 1.5 <0.1 <0.1
2 x RRUS 11 B2 L
4 x 40 W E+ 11.9 5.0 9.5 4.3 3.5 1.5 <0.1 <0.1
4 x 30 W E+ 10.7 4.4 8.6 2.9 3.1 1.5 <0.1 <0.1
2 x RRUS 11 B4 L
4 x 40 W E+ 12.4 5.2 9.9 4.5 3.5 1.6 <0.1 <0.1
4 x 30 W E+ 13.1 5.8 10.1 4.6 2.4 2.0 <0.1 <0.1
2 x RRUS 11 B5 L
4 x 40 W E+ 15.1 6.7 11.6 5.2 2.7 2.0 <0.1 <0.1
2 x RRUS 11 B13 L 4 x 40 W E+ 14.9 6.7 11.6 5.2 3.5 2.0 <0.1 <0.1
2 x RRUS 12 B2 L 4 x 60 W E+ 14.7 6.3 11.7 5.3 4.3 2.0 <0.1 <0.1
2 x RRUS 12 B4 L 4 x 60 W E+ 15.3 6.6 12.2 5.5 4.4 2.0 <0.1 <0.1
2 x RRUS 12 B5 L 4 x 60 W E+ 18.5 8.3 14.3 6.4 3.3 2.0 <0.2 <0.1

17 This row shows results for the KRE 101 2294/1 antenna.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 12 (50)
Radio Frequency Electromagnetic Exposure

Table 3-1 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Minimum and Maximum
Power Configurations using AIR (Antenna Integrated Radio) with
0.6 dB Tolerance and Assumed 0 dB Transmission Loss.
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for AIR (antenna integrated Distance in Distance
radio) front of Width Height behind
antenna antenna
Nominal output power
Band Standard GP O GP O GP O GP O
from the radio
20 W 1.9 0.5 1.2 0.4 1.5 1.5 0 0
B1 (2100)18 W/L
60 W 5.5 1.1 4.0 0.7 1.5 1.5 0 0
20 W 1.7 0.5 1.2 0.5 2.0 2.0 0 0
B1 (2100)19 W/L
60 W 5.4 1.1 3.3 0.8 2.0 2.0 0 0
20 W 2.7 0.6 1.3 0.4 1.5 1.5 0 0
B2 (1900)20 G/W/L
60 W 5.9 1.6 4.1 0.9 1.7 1.5 0 0
20 W 1.8 0.5 1.0 0.4 2.5 2.5 0 0
B2 (1900)21 G/W/L
60 W 5.1 1.0 3.3 0.6 2.6 2.5 0 0
20 W 1.3 0.5 1.2 0.4 2.0 2.0 0 0
B2 (1900)22 G/W/L
60 W 5.4 1.2 3.6 0.9 2.0 2.0 0 0
B2 (1900) 23 G/W/L 120 W 14.2 6.1 10.4 3.4 1.9 1.6 < 0.1 0
B2 (1900)24 G/W/L 120 W 11.1 4.7 8.0 3.0 2.5 2.0 0 0
20 W 2.6 1.0 1.8 0.6 1.5 1.5 0 0
B3 (1800)25 G/W/L
60 W 5.6 1.9 3.6 1.4 1.5 1.5 0 0
20 W 1.9 0.5 1.3 0.5 2.5 2.5 0 0
B3 (1800)26 G/W/L
60 W 5.2 1.1 4.1 1.0 2.5 2.5 0 0
B3 (1800)27 G/L 120 W 12.8 4.8 11.5 3.1 2.8 2.0 0 0
20 W 2.0 0.6 1.4 0.4 1.5 1.5 0 0
B4 (17/2100)28 W/L
60 W 5.7 1.4 4.2 0.8 1.6 1.5 0 0
20 W 1.8 0.5 1.2 0.4 2.5 2.5 0 0
B4 (17/2100)29 W/L
60 W 5.3 1.1 3.5 0.7 2.6 2.5 0 0
20 W 1.7 0.5 1.2 0.5 2.0 2.0 0 0
B4 (17/2100)30 W/L
60 W 5.4 1.1 3.3 0.8 2.0 2.0 0 0
B4 (17/2100)31 W/L 120 W 15.2 6.1 10.5 3.0 1.8 1.5 0 0
20 W 1.2 0.4 0.9 0.4 1.5 1.5 0 0
B7 (2600) L
60 W 3.3 0.9 2.4 0.5 1.5 1.5 0 0
B7 (2600)32 L 120 W 10.8 2.6 7.0 1.5 5.7 2.5 0 0
B3 (1800), G/L, L 240 W 16.7 6.9 13.6 4.0 5.8 2.6 0 0

18 This row shows the compliance boundary dimensions of the KRE 101 2144/1 antenna.
19 This row shows the compliance boundary dimensions of the KRE 101 2168/1 antenna.
20 This row shows the compliance boundary dimensions of the KRE 101 2132/1 antenna.
21 This row shows the compliance boundary dimensions of the KRE 101 2174/1 antenna.
22 This row shows the compliance boundary dimensions of the KRE 101 2170/1 antenna.
23 This row shows the compliance boundary dimensions of the KRE 105 244/1 antenna.
24 This row shows the compliance boundary dimensions of the KRE 101 241/1 antenna.
25 This row shows the compliance boundary dimensions of the KRE 101 2148/1 antenna.
26 This row shows the compliance boundary dimensions of the KRE 101 2166/1 antenna.
27 This row shows the compliance boundary dimensions of the KRE 105 241/1 antenna.
28 This row shows the compliance boundary dimensions of the KRE 101 2133/1 antenna.
29 This row shows the compliance boundary dimensions of the KRE 101 2149/1 antenna.
30 This row shows the compliance boundary dimensions of the KRE 101 2167/1 antenna.
31 This row shows the compliance boundary dimensions of the KRE 105 216/1 antenna.
32 This row shows the compliance boundary dimensions of the KRE 105 237/1 antenna.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 13 (50)
Radio Frequency Electromagnetic Exposure

Dimensions of the box-shaped compliance boundary (m)


Mode and output power for AIR (antenna integrated Distance in Distance
radio) front of Width Height behind
antenna antenna
Nominal output power
Band Standard GP O GP O GP O GP O
from the radio
B7 (2600)33
20 W 3.6 0.8 1.7 0.4 2.0 2.0 0 0
B8 (900E) G/W
60 W 7.0 1.9 4.8 1.2 2.0 2.0 0 0
20 W 3.6 0.7 1.8 0.4 2.1 2.0 0 0
B20 (800DD)34 L
60 W 7.2 1.9 5.4 1.1 2.3 2.0 0 0
20 W 3.5 1.2 2.5 0.6 1.5 1.5 0 0
B20 (800DD)35 L
60 W 6.2 2.8 4.8 1.8 1.8 1.5 0 0
B66
W/L 120 W 15.1 6.1 10.7 3.2 1.9 1.6 0 0
(17/2100)21
B66 (17/2100)
36 W/L 120 W 9.8 2.6 12.2 2.8 2.6 2.0 0 0
B2 (1900), B66
G/W, W/L 240 W 20.9 9.1 15.4 6.0 2.2 1.6 < 0.1 0
(17/2100) 37
B7 (2600),
B66 (17/2100) L, W/L 240 W 14.2 5.3 14.1 3.5 5.9 2.6 0 0
38

Note: The distance behind antenna given in Table 3 is measured from the
back of the AIR radio unit.

Table 3-2 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Maximum Power
Configurations using AIR (Antenna Integrated Radio) with time-
division duplexing (TDD) and Assumed 0 dB Transmission Loss.
Dimensions of the box-shaped compliance
boundary (m)
Mode and output power for AIR (antenna integrated radio) Distance Distance
in front Width Height behind
of antenna antenna
Nominal IEC 62232 Output
Product TDD
Band Standard EIRP per Installation power GP O GP O GP O GP O
name factor
beam39 class tolerance
B41E
AIR 6468 L 72.1 dBm E+ 1 dB 0.9 17.4 7.8 21.9 9.8 13.5 6.0 0 0
(2600)
B41
AIR 6468 L 71.3 dBm E+ 1.5 dB 0.9 16.9 7.5 21.1 9.4 13.0 5.8 0 0
(2600)
B42
AIR 6468 L 71.8 dBm E+ 1 dB 0.9 17.8 8.0 22.4 10.0 13.8 6.1 0 0
(3500)
B257A
AIR 5121 VTF 46 dBm E+40 1.5 dB 0.89 1.8 0.8 2.3 1.0 1.0 0.5 0 0
(28000)

33 KRE 105 245/1 transmits simultaneously on B3 and B7 with the power divided equally among the two
bands.
34 This row shows the compliance boundary dimensions of the KRE 101 2087/1 antenna.
35 This row shows the compliance boundary dimensions of the KRE 101 2131/1 antenna.
36 This row shows the compliance boundary dimensions of the KRE 105 241/1 antenna.
37 KRE 105 244/1 transmits simultaneously on B2 and B66 with equal power ratios.
38 KRE 105 245/1 transmits simultaneously on B7 and B66 with equal power ratios.
39 The stated EIRP value is the peak beam EIRP without power tolerance included.
40 The total EIRP for 8 beams is equal to 55 dBm i.e, above E+ power limit.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 14 (50)
Radio Frequency Electromagnetic Exposure

Table 4 Characteristics for the tested antennas


X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna
directional antenna directional antenna directional antenna directional antenna
specifications
(BXA-70063/6CF) (KRE 101 1985/1) (KRE 101 2085/1 v01) (KRE 101 2085/1 v02)
Antenna
Height: 1.8 m Height: 1.3 m Height: 1.4 m Height: 1.45 m
dimensions
Half-power
63 degrees 64-68 degrees 60-61 degrees 63, 68, 58 degrees
beam width
Antenna gain 17 dBi 18.2 dBi 18 dBi 18.2,17.6,19 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees


B1, B2, B3, B4, B9,
Tested bands B12, B13, B14 B7, B38, B40, B41 B1, B3, B7
B25, B39
X-pol macro RBS X-pol macro RBS
X-pol macro RBS
Antenna directional 8-branch directional 8-branch X-pol macro RBS
directional antenna
specifications antenna (TYDA- antenna (ODS- directional antenna
(KRE 101 2057/1)
202415D4T0) 090R15NV06(F))
Antenna
Height: 1.4 m Height: 1.4 m Height: 2.6 m Height: 1.4 m
dimensions
Half-power
29 degrees ≤25 degrees 65-66 degrees 67 degrees
beam width
Antenna gain 20 dBi 22 dBi 17 dBi 18 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees

Tested bands B39 (MIMO only) B38, B41 (MIMO only) B0, B8 B11, B32

X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2087/1), (KRE 101 2132/1), (KRE 101 2133/1), (KRE 101 2146/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna
Height: 2.0 m Height: 1.4 m Height: 1.4 m Height: 2.0
dimensions
Half-power
66 degrees 62 degrees 62 degrees 63 degrees
beam width
Antenna gain 16 dBi 18 dBi 18 dBi 16 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees

Tested bands B20 (AIR only) B2 (AIR only) B4 (AIR only) B8 (AIR only)

X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2149/1), (KRE 101 2144/1), (KRE 101 2148/1), (KRE 101 2166/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna
Height: 2.3 m Height: 1.4 m Height: 1.4 m Height: 2.4 m
dimensions
Half-power
60 degrees 65 degrees 65 degrees 63 degrees
beam width
Antenna gain 17 dBi 18 dBi 18 dBi 17.2 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees

Tested bands B4 (AIR only) B1 (AIR only) B3 (AIR only) B3 (AIR only)

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 15 (50)
Radio Frequency Electromagnetic Exposure

X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2163/1), (KRE 101 2131/1), (KRE 101 2174/1), (KRE 101 2170/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna Height: 2.0 m
Height: 1.4 m Height: 1.4 m Height: 2.4 m
dimensions
Half-power 63 degrees
55 degrees 67 degrees 60 degrees
beam width
Antenna gain 18.1 dBi 14.2 dBi 16.8 dBi 17.9 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees

Tested bands B7 (AIR only) B20 (AIR only) B2 (AIR only) B2 (AIR only)

X-pol macro RBS X-pol macro RBS


X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna
directional antenna directional antenna
specifications (KRE 101 2167/1), (KRE 101 2168/1),
(KRE 101 2224/1) (RFS APXVSPP18-C)
Integrated in AIR Integrated in AIR
Antenna
Height: 1.4 m Height: 1.8 m Height: 2.0 m Height: 2.0 m
dimensions
Half-power
65-68 degrees 65 degrees 63 degrees 63 degrees
beam width
Antenna gain 14.2-14.8 dBi 18 dBi41 18.1 dBi 18.1 dBi

Down tilt 0 degrees 0 degrees 0 degrees 0 degrees

Tested bands B18, B28, B29 B25 B4 (AIR only) B1 (AIR only)

X-pol macro RBS X-pol macro RBS X-pol macro RBS


X-pol macro RBS
Antenna directional antenna directional antenna directional antenna
directional antenna
specifications (KRE 105 216/1), (KRE 105 237/1), (KRE 105 245/1),
(KRE 101 2092/1)
Integrated in AIR Integrated in AIR Integrated in AIR
Antenna
Height: 1.5 m Height: 1.4 m Height: 2.0 m Height: 2.0 m
dimensions
62/64 degrees (B3),
Half-power
57-67 degrees 61 degrees 62/58 degrees 63/58 degrees (B7)
beam width
59/63 degrees (B66)
17 / 16.9 (B3),
Antenna gain 17.5 -18.9 dBi39 18.439 17.1/17.942 17.5 / 17.9 (B7)43
17.5 / 17.3 (B66)
Down tilt 0 degrees 0 degrees 2.5 degrees 2.5 degrees
B2, B3, B4, B7, B30,
Tested bands B4 B7 B3, B7, B66
B38, B40, B41, B66
X-pol macro RBS X-pol macro RBS
X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna
directional antenna directional antenna
specifications (KRE 105 244/1), (KRE 105 241/1),
(KRE 101 1902/1) (KRE 101 2260/1)
Integrated in AIR Integrated in AIR
Antenna
Height: 2 m Height: 1.0 m Height: 1.4 m Height: 2.0 m
dimensions
59 / 65 degrees (B2),
Half-power 62 degrees (B2),
65 degrees 70.6 degrees 62 / 64 degrees (B3),
beam width 61 degrees (B66)
59 / 63 degrees (B66)
17.5 / 16.9 (B2),
17.8 (B2),
Antenna gain 15 dBi 17.7 dBi 17.0 / 16.9 (B3),
18.3 (B66)39
17.5 / 17.3 (B66)40
Down tilt 0 degrees 2 - 12 degrees 2 degrees 2 degrees

Tested bands B31 B42 B2, B66 B2, B3, B66

41 The far-field properties for this antenna are given for one of the ports excited.
42 The far-field properties for this antenna correspond to values for the two array columns (broadside
beam excitation).
43 The far-field properties for this antenna correspond to values for the two array columns (broadside

beam excitation).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 16 (50)
Radio Frequency Electromagnetic Exposure

X-pol macro RBS Internal AAS


Antenna X-pol macro RBS X-pol macro RBS
directional antenna antenna
specifications directional antenna44 directional antenna45
(KRE 101 2021/1) (KRE 105 257/1)
Antenna
Height: 1.3 m Height: 1.8m Height: 0.99m Height: 1.8m
dimensions
Half-power
65-67 degrees 32.7 degrees 12±4 degrees 33.2
beam width
Antenna gain 15 dBi 19.5 dBi46 24.347 19.448
±60° (azimuth)
Down tilt/
0 degrees 0 degrees 73° - 113° 0 degrees
beam steering
(elevation)
Tested bands B5, B8, B20, B26 B14 B41E B13

X-pol macro RBS X-pol macro RBS X-pol macro RBS


Internal AAS
Antenna directional antenna directional antenna directional antenna
antenna
specifications (ODI-065R15I02- (KRE 101 2301/1) (KRE 101 2294/1)
(PAAM)49
Q)
Height x Width:
Antenna
Height: 2.4 m Height: 2.0 m Height: 1.5 m 0.07 m x 0.07 m
dimensions
per PAAM
Half-power
67 degrees 60 degrees 59-68 degrees 12±2 degrees
beam width
17.9 dBi (B1,B2,B4,
15.6 dBi (B5)51
B66)51
Antenna gain 1950 dBi 15.8 dBi (B8) 51 2452 dBi
17.3 dBi (B3)51
14.8 dBi (B13) 51
18.3 dBi (B40)51
Down tilt/ ±60° (azimuth)
0 degrees 2 degrees 2 degrees
beam steering ±15 (elevation)
B1, B2, B3, B4, B40,
B5, B8, B13
Tested bands B71 B66 B257A
(4TX MIMO)
(4TX MIMO)

44 Two 2 Tx antennas based on BXA-70063/6CF were used to create a 4 Tx antenna model for B14 since

no real antenna was available


45 Two 2 Tx antennas based on BXA-70063/6CF were used to create a 4 Tx antenna model for B13 since

no real antenna was available


46 The information specified here is the data obtained for the 2 Tx antenna model based on BXA-

70063/6CF
47 The stated gain value is the peak beam gain.
48 The information specified here is the data obtained for the 2 Tx antenna model based on BXA-

70063/6CF
49 The antenna unit consists of four Phase Array Antenna Modules (PAAM) with 2 active beams per each

PAAM.
50 The far-field properties for this antenna correspond to values for the two array columns (broadside

beam excitation).
51 The far-field properties for this antenna are given for one of the ports excited.
52 The stated gain value is the peak beam gain.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 17 (50)
Radio Frequency Electromagnetic Exposure

Internal AAS Internal AAS


Antenna
antenna antenna
specifications
(KRE 105 264/1) (KRE 105 257/2)
Antenna
Height: 0.99 m Height: 0.99m
dimensions
Half-power
12±4 degrees 12±4 degrees
beam width
Antenna gain 24.053 23.554
±60° (azimuth) ±60° (azimuth)
Down tilt/
73° - 113° 73° - 113°
beam steering
(elevation) (elevation)
Tested bands B2 B41

53 The stated gain value is the peak beam gain.


54 The stated gain value is the peak beam gain.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 18 (50)
Radio Frequency Electromagnetic Exposure

Table 5 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RU (Internal Radio Unit) including 0.6 dB
Tolerance and 3 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 40.6/11.5
B0 (900P) G/W/L
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B1 (2100) W/L
50.0/100 47.6/57.5
G/W/L/C 43.0/20 40.6/11.5
B2 (1900) C 49.0/80 46.6/45.7
G/W/L 50.0/100 47.6/57.5
43.0/20 40.6/11.5
B3 (1800) G/W/L
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B4 (17/2100) W/L/C
49.0/80 46.6/45.7
43.0/20 40.6/11.5
B5 (850) G/W/L/C
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B7 (2600) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
W/L
50.0/100 47.6/57.5
B8 (900E)
43.0/20 40.6/11.5
G
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B11 (1500) W
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B12 (70012) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B13 (70013) L
47.8/60 45.4/34.7
B13 (70013)55 L 53.8/240 51.4/138
43.0/20 40.6/11.5
B14 (70014) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B20 (800DD) L
49.0/80 46.6/45.7
43.0/20 40.6/11.5
B28 (700) L
50.0/100 47.6/57.5

55 These assessments were made for a 4-branch antenna (4 Tx).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 19 (50)
Radio Frequency Electromagnetic Exposure

Table 6-1 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) including 0.6 dB
Tolerance and 0.5 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.1/20.4
B0 (900P) G/W/L
50.8/120 50.9/123
43.0/20 43.1/20.4
B1 (2100) W/L
52.0/160 52.1/162.2
B1 (2100) 56 W/L 52.0/160 52.1/162.2
43.0/20 43.1/20.4
B2 (1900) G/W/L
52.0/160 52.1/162.2
46.0/40 46.1/40.7
B2 (1900)57 L
52.0/160 52.1/162.2
B2 (1900) /
L 55.0/320 55.1/324
B66A (2100) 58
B2 (1900) /
L 55.0/320 55.1/324
B66A (2100)59
B2 (1900) /
L 54.5/280 54.6/288
B66A (2100) 60
43.0/20 43.1/20.4
B3 (1800) G/W/L
52.0/160 52.1/162.2
L 43.0/20 43.1/20.4
B3 (1800)61 46.0/40 46.1/40.7
G/L
52.0/160 52.1/162.2
B1 (2100),
W, G/L 52.0/160 52.1/162.2
B3 (1800)61
B1 (2100) / B3
W, L 52.0/160 52.1/162.2
(1800) 62
43.0/20 43.1/20.4
B4 (17/2100) W/L/C
50.8/120 50.9/123
46.0/40 46.1/40.7
B4 (17/2100)61 L
52.0/160 52.1/162.2
43.0/20 43.1/20.4
B5 (850) G/W/L/C
52.0/160 52.1/162.2
B5 (850)63 W/L 52.0/160 52.1/162.2
43.0/20 43.1/20.4
B7 (2600) L
50.8/120 50.9/123
46.0 / 40 46.1 / 40.7
B7 (2600)61 L
52.0 / 160 52.1 / 162.2

56 These assessments were made for a 4-branch antenna (4 Tx).


57 These assessments were made for a 4-branch antenna (4 Tx).
58 These assessments were made for an 8-branch antenna (8Tx). The product is transmitting

simultaneously on B2 (4 Tx) and B66A (4Tx) with the power distributed equally.
59 These assessments were made for an 8-branch antenna (8Tx). The product is transmitting

simultaneously on B2 (4 Tx) and B66A (4Tx) with power distributed as 25 % and 75 % over the bands,
respectively.
60 These assessments were made for a 4-branch antenna (4 Tx). The product is transmitting

simultaneously on B2 (2 Tx) and B66A (2Tx) with power distributed as 43 % and 57 % over the bands,
respectively.
61 This power level is used in a multi-band product transmitting simultaneously on B1 and B3 with the

power distributed equally among the two bands.


62 These assessments were made for a 4-branch antenna (4 Tx). The product is transmitting

simultaneously on B1 and B3 with the power distributed equally.


63 These assessments were made for a 4-branch antenna (4 Tx).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 20 (50)
Radio Frequency Electromagnetic Exposure

Nominal output power from the Total power delivered to


Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.1/20.4
G/W/L
52.0/160 52.1/162.2
B8 (900E)
43.0/20 43.1/20.4
G
50.8/120 50.9/123
B8 (900E)64 G/W/L 52.0/160 52.1/162.2
43.0/20 43.1/20.4
B9 (17/1800) W/L
47.8/60 47.9/61.7
43.0/20 43.1/20.4
B11 (1500) W/L
49.0/80 49.1/81.3
43.0/20 43.1/20.4
B12 (70012) L
49/80 49.1/81.3
43.0/20 43.1/20.4
B13 (70013) L
50.8/120 50.9/123
B14 (700) L 52 / 160 52.1 / 162.2
37.8/6.0 37.9/6.2
B18 (800), 36.0/4.0 36.1/4.1
L
B28 (700)65 47.8/60.3 47.9/61.7
46.0/39.8 46.1/40.7
43.0/20 43.1/20.4
B20 (800DD) L
49.0/80 49.1/81.3
43.0/20 43.1/20.4
B25 (1900G) W/L/C
49.0/80 49.1/81.3
46/40 46.1/40.7
B25 (1900G)66 W/L/C
52/160 52.1/162.2
43.0/20 43.1/20.4
B26 (850) L/C
49.0/80 49.1/81.3
43.0/20 43.1/20.4
B28 (700) L 49.0/79.4 49.1/81.3
52.0/160 52.1/162.2
43.0/20 43.1/20.4
B29 (700) L
49.0/80 49.1/81.3
44.0 / 25 44.1 / 25.7
B30 (2300) L
50.0 / 100 50.1 / 102.3
43.0/20 43.1/20.4
B31 (450) L
49.0/80 49.1/81.3
43.0/20 43.1/20.4
B32 (1500) L
52.0/160 52.1/162.2
43.0/20 43.1/20.4
B38 (2600) L
49.0/80 49.1/81.3
46.0/40 46.1/40.7
B38 (2600)70 L
52.0/160 52.1/162.2
43.0/20 43.1/20.4
B39 (1900) L
49.0/80 49.1/81.3
43.0/20 43.1/20.4
B40 (2300) L
50.0/100 50.1/102
46.0/40 46.1/40.7
B40 (2300) 70 L
52.0/160 52.1/162.2
B41 (2500) L 43.0/20 43.1/20.4

64 These assessments were made for a 4-branch antenna (4 Tx).


65 This power level is used in a multi-band product transmitting simultaneously on B18 and B28 with
power distributed as 60 % and 40 % over the bands, respectively.
66 These assessments were made for a 4-branch antenna (4 Tx).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 21 (50)
Radio Frequency Electromagnetic Exposure

Nominal output power from the Total power delivered to


Band Standard
radio (dBm/W) antenna (dBm/W)
46.0/40 46.1/40.7
50.8/120 50.9/123
52.0/160 52.1/162.2
B41 (2500) 70 L 43.0/20 43.1/20.4
52.0/160 52.1/162.2
46.0/40 46.1/40.7
B41 (2500)67 L
50.8/120 50.9/123
43.0/20 43.1/20.4
B42 (3500) L
49.0/80 49.1/81.3
B66 46.0/40 46.1/40.7
W/L
(17/2100) 70 53.8/240 53.9/245.5
B71 (600) L 52.0/160 52.1/162.2

Table 6-2 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) with time-division
duplexing (TDD) including 0.6 dB Tolerance, 0.5 dB Transmission
Loss and Maximum TDD factor.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
B40 (2300) L 46 / 160 50.8 / 120

Table 6-3 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) including 1 dB
Tolerance and 0.5 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.5/22.4
B38 (2600) L
49.0/80 49.5/89.1
46.0/40 46.5/44.7
B38 (2600)68 L
50.8/120 51.3/134.9
46.0/40 46.5/44.7
B39 (1900)72 L
49.0/80 49.5/89.1
43.0/20 43.5/22.4
B40 (2300) L
46.0/40 46.5/44.7
46.0/40 46.5/44.7
B41(2500)72 L
53.8/240 54.3/269.2

67 These assessments were made for an 8-branch antenna (8 Tx).


68 These assessments were made for an 8-branch antenna (8 Tx).

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 22 (50)
Radio Frequency Electromagnetic Exposure

Table 7-1 Total Power to the Antenna for Minimum and Maximum Power
Configurations using AIR (Antenna Integrated Radio Unit)
including 0.6 dB Tolerance and 0 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.6/22.9
B1 (2100)69 W/L
47.8/60 48.4/69.2
43.0/20 43.6/22.9
B2 (1900)70 G/W/L
47.8/60 48.4/69.2
50.8 / 120 51.4 / 138
43.0/20 43.6/22.9
G/W/L
B3 (1800)71 47.8/60 48.4/69.2
G/L 50.8 / 120 51.4 / 138
43.0/20 43.6/22.9
B4 (17/2100)72 W/L 47.8/60 48.4/69.2
50.8/120 51.4/138
43.0/20 43.6/22.9
B7 (2600) 73 L 47.8/60 48.4/69.2
50.8/120 51.4/138
B3 (1800),
G/L, L 53.8 / 240 54.4 / 275
B7 (2600)74
43.0/20 43.6/22.9
B8 (900E) G/W
47.8/60 48.4/69.2
43.0/20 43.6/22.9
B20 (800DD)75 L
47.8/60 48.4/69.2
B66 (17/2100)76 W/L 50.8 / 120 51.4 / 138
B2 (1900),
B66 G/W, W/L 53.8 / 240 54.4 / 275
(17/2100) 77
B3 (1800),
L, W/L 53.8 / 240 54.4 / 275
B7 (2600)78

69 B1 has been tested for two different antennas.


70 B2 has been tested for five different antennas.
71 B3 has been tested for four different antennas.
72 B4 has been tested for four different antennas.
73 B7 has been tested for three different antennas.
74 This power level is used in a multi-band product transmitting simultaneously on B3 and B7 with the

power distributed equally among the two bands.


75 B20 has been tested for two different antennas.
76 This power level is applicable to two different products capable of transmission on B66.
77 This power level is used in a multi-band product transmitting simultaneously on B2 and B66 with the

power distributed equally among the two bands.


78 This power level is used in a multi-band product transmitting simultaneously on B7 and B66 with the

power distributed equally among the two bands.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 23 (50)
Radio Frequency Electromagnetic Exposure

Table 7-2 Total Power to the Antenna for Minimum and Maximum Power
Configurations using AIR (Antenna Integrated Radio Unit)
including Tolerance, 0 dB Transmission Loss and Maximum TDD
Factor
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
B41E (2600) L 50.8 / 120 51.3 / 136
B41 (2600) L 50.8 / 120 51.8 / 151
B42 (3500) L 50.8 / 120 51.8 / 151
B257A (28000) VTF 31 / 1.3 32 / 1.6

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 24 (50)
Radio Frequency Electromagnetic Exposure

2.2 Micro RBS


For the micro products, box-shaped compliance boundaries are used. For
configurations with internal antennas or external sector coverage antennas,
the front and back compliance distances are defined from the
equipment/antenna casing as shown in Figure 3. For configurations with
external omni-directional antennas, the compliance boundary dimensions are
defined with respect to the origin centered between the dipole antenna
elements, see Figure 4.

Figure 3. Box-shaped Compliance Boundary used for configurations with


internal antennas and for configurations with external sector coverage
antennas. The front and back compliance distances are defined from the
EUT/antenna casing.

Figure 4. Box-shaped Compliance Boundary used for configurations with


external omni-directional antennas. The compliance boundary dimensions are
defined with respect to the origin centered between the dipole antenna
elements.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 25 (50)
Radio Frequency Electromagnetic Exposure

The resulting compliance boundary dimensions in meters are shown in


Table 8 and Table 9. The power levels used for the assessments include
power tolerances and transmission losses. The transmitted field distributions
are dependent on the used antenna. Separate calculations or measurements
may therefore be necessary to establish compliance boundaries for
configurations employing other external antennas chosen by the customer.
For further information on RF exposure assessment methods, see [6]. The
expanded uncertainty (k=2) is 2.3 dB for the underlying calculations of the
power density used for assessment of the compliance boundary dimensions
listed in Table 8.

Characteristics of the antennas recommended are listed in Table 10.

The total powers fed to the antennas (including tolerance and assumed
transmission loss) are given in Table 11.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 26 (50)
Radio Frequency Electromagnetic Exposure

Table 8-1 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for mRRUS 12 with 1 dB
tolerance and 0 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the mRRU Distance in Distance
(external radio unit) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case79 from the radio
B1 (2100),
KRE 101 2141/1, W/L 2×5W 0.9 0.4 0.8 0.4 1.0 0.6 0 0
Vertical
B3 (1800),
KRE 101 2141/1, W/L 2×5W 0.8 0.4 0.9 0.4 1.0 0.6 0 0
Vertical
B7 (2600),
KRE 101 2142/1, L 2×5W 0.9 0.4 0.8 0.4 1.0 0.6 0 0
Vertical
B1 (2100),
KRE 101 2141/1, W/L 2×5W 0.9 0.4 1.0 0.6 0.8 0.4 0 0
Horizontal
B3 (1800),
KRE 101 2141/1, W/L 2×5W 0.8 0.4 1.0 0.6 0.9 0.4 0 0
Horizontal
B7 (2600),
KRE 101 2142/1, L 2×5W 0.9 0.4 1.0 0.6 0.8 0.4 0 0
Horizontal
B1 (2100),
KRE 101 1985/1, W/L 2×5W 0.8 0.2 0.5 0.2 1.4 1.4 <0.1 <0.1
Horizontal/Vertical
B3 (1800),
KRE 101 1985/1, W/L 2×5W 1.0 0.2 0.6 0.2 1.4 1.4 <0.1 <0.1
Horizontal/Vertical
B1 (2100),
KRE 101 2024/1, W/L 2×5W 0.6 0.3 1.2 0.6 0.6 0.3 0.6 0.3
Vertical
B3 (1800),
KRE 101 2024/1, W/L 2×5W 0.7 0.3 1.3 0.7 0.7 0.3 0.7 0.3
Vertical
B7 (2600),
KRE 101 2024/1, L 2×5W 0.5 0.3 0.9 0.5 0.4 0.2 0.5 0.3
Vertical
B1 (2100),
KRE 101 2024/1, W/L 2×5W 0.6 0.2 1.3 0.7 0.6 0.3 0.6 0.2
Horizontal
B3 (1800),
KRE 101 2024/1, W/L 2×5W 0.7 0.3 1.3 0.8 0.6 0.3 0.7 0.3
Horizontal
B7 (2600),
KRE 101 2024/1, L 2×5W 0.5 0.4 1.0 0.7 0.4 0.2 0.5 0.4
Horizontal

79 The installation case refers to the orientation of the equipment.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 27 (50)
Radio Frequency Electromagnetic Exposure

Table 8-2 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for mRBS 6501 with 1 dB
tolerance and 0 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the mRBS Distance in Distance
(micro-RBS) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case80 from the radio
B1 (2100),
KRE 101 2141/1, W/L 2×5W 0.9 0.4 0.8 0.4 0.8 0.5 0 0
Vertical
B3 (1800),
KRE 101 2141/1, W/L 2×5W 0.8 0.4 0.8 0.4 0.8 0.5 0 0
Vertical
B7 (2600),
KRE 101 2142/1, L 2×5W 0.9 0.4 0.8 0.4 0.9 0.5 0 0
Vertical
B1 (2100),
KRE 101 2141/1, W/L 2×5W 0.9 0.4 0.8 0.5 0.8 0.4 0 0
Horizontal
B3 (1800),
KRE 101 2141/1, W/L 2×5W 0.8 0.4 0.8 0.5 0.8 0.4 0 0
Horizontal
B7 (2600),
KRE 101 2142/1, L 2×5W 0.9 0.4 0.9 0.5 0.8 0.4 0 0
Horizontal
B1 (2100),
KRE 101 1985/1, W/L 2×5W 0.8 0.2 0.5 0.2 1.4 1.4 <0.1 <0.1
Horizontal/Vertical
B3 (1800),
KRE 101 1985/1, W/L 2×5W 1.0 0.2 0.6 0.2 1.4 1.4 <0.1 <0.1
Horizontal/Vertical
B7 (2600),
KRE 101 2085/1, L 2×5W 1.0 0.1 0.6 0.2 1.4 1.4 < 0.1 < 0.1
Horizontal/Vertical
B1 (2100),
KRE 101 2024/1, W/L 2×5W 0.6 0.3 1.2 0.6 0.6 0.3 0.6 0.3
Vertical
B3 (1800),
KRE 101 2024/1, W/L 2×5W 0.7 0.3 1.3 0.7 0.7 0.3 0.7 0.3
Vertical
B7 (2600),
KRE 101 2024/1, L 2×5W 0.5 0.3 0.9 0.5 0.4 0.2 0.5 0.3
Vertical
B1 (2100),
KRE 101 2024/1, W/L 2×5W 0.6 0.2 1.3 0.7 0.6 0.3 0.6 0.2
Horizontal
B3 (1800),
KRE 101 2024/1, W/L 2×5W 0.7 0.3 1.3 0.8 0.6 0.3 0.7 0.3
Horizontal
B7 (2600),
KRE 101 2024/1, L 2×5W 0.5 0.4 1.0 0.7 0.4 0.2 0.5 0.4
Horizontal

80 For internal antennas and antennas mounted on the equipment, the installation case refers to the
orientation of the equipment. For external antennas not mounted on the equipment, the installation case
refers to the orientation of the antennas.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 28 (50)
Radio Frequency Electromagnetic Exposure

Table 8-3 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for Radio 2203 with 1 dB
tolerance and 0 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the RRU Distance in
(micro-RBS) Distance
front of Width Height
behind radio
radio
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case84 from the radio
B1 (2100)
KRE 101 2249/1 W/L 2×5W 1.2 0.5 1.0 0.5 0.8 0.4 0 0
Vertical
B3 (1800)
KRE 101 2249/1 W/L 2x5W 1.1 0.5 1.0 0.5 0.8 0.4 0 0
Vertical
B1 (2100),
KRE 101 2024/1 W/L 2×5W 0.6 0.2 1.4 0.8 0.6 0.2 0.6 0.2
Vertical
B7 (2600)
KRE 101 2250/1 W/L 2x5W 1.1 0.5 1.0 0.5 0.7 0.4 0 0
Vertical
B5 (800)
KRE 101 2199/1 W/L 2x5W 1.2 0.6 1.1 0.6 1.2 0.6 0 0
Vertical
B8 (900)
KRE 101 2199/1 W/L 2×5W 1.2 0.6 1.1 0.5 1.2 0.6 0 0
Vertical
B1 (2100),
KRE 101 2266/1 W/L 2×5W 0.6 0.2 1.3 0.8 0.6 0.2 0.6 0.2
Vertical
B3 (1800)
KRE 101 2266/1 W/L 2x5W 0.6 0.2 1.4 0.8 0.6 0.3 0.6 0.2
Vertical
B5 (800)
KRE 101 2266/1 W/L 2x5W 0.9 0.4 1.8 1.0 0.9 0.4 0.9 0.4
Vertical
B7 (2600)
KRE 101 2266/1 W/L 2x5W 0.6 0.2 1.3 0.8 0.6 0.2 0.6 0.2
Vertical
B8 (900)
KRE 101 2266/1 W/L 2×5W 0.9 0.4 1.8 1.0 0.8 0.4 0.9 0.4
Vertical

Table 8-4 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for RRU 2208 with 1 dB
tolerance and 0 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the RRU Distance in
(micro-RBS) Distance
front of Width Height
behind radio
radio
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case81 from the radio
B41 (TD 2500), 2×1W 0.5 0.2 0.5 0.2 0.3 0.2 0.0 0.0
KRE 101 2250/2 L
Vertical 2 × 10 W 1.6 0.7 1.4 0.7 0.8 0.4 0.0 0.0

81 The installation case refers to the orientation of the equipment.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 29 (50)
Radio Frequency Electromagnetic Exposure

Table 8-5 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for mRRUS 61 with 1 dB
tolerance and 0 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the mRRU Distance in Distance
(external radio unit) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case85 from the radio
B38 (2600),
KRE 101 2142/2, L 2×5W 0.7 0.3 0.7 0.3 0.8 0.5 <0.1 <0.1
Vertical

Table 8-6 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for RRU 22F3 with 0.6 dB
tolerance and 0.2 dB transmission loss (intended markets:
Europe/Rest of world).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the RRU Distance in
(micro-RBS) Distance
front of Width Height
behind antenna
antenna
Band, antenna, Nominal output power
Standard GP O GP O GP O GP O
installation case82 from the radio
2.8 W (B1: 1.2 W,
B1 / B18 / B2883, 0.3 0.1 1.3 1.0 0.4 0.3 0.3 0.1
B18: 0.8 W, B28: 0.8 W)
KRE 101 2245/1, L
28 W (B1: 12 W,
Vertical 1.2 0.5 2.7 1.5 1.1 0.5 1.2 0.5
B18: 8 W, B28: 8 W)

The maximum available power to Radio 2205, tested for B46A (5155 MHz –
5250 MHz) for the European market, including output power tolerance of 1 dB
and 0 dB transmission loss is 17.8 mW, which is less than the applicable low-
power exclusion level of 20 mW specified in [7]. As a consequence, no RF
exposure evaluation is required, and the product is inherently in compliance
with the appropriate RF exposure standards and recommendations.

82 For internal antennas and antennas mounted on the equipment, the installation case refers to the
orientation of the equipment. For external antennas not mounted on the equipment, the installation case
refers to the orientation of the antennas.
83 This row shows the result for RRU 22F3 with simultaneous operation on B1, B18 and B28 with power

ratios of 42.9 %, 28.6 % and 28.6 %, respectively. The orientation of the antennas is independent from
the orientation of the RRU.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 30 (50)
Radio Frequency Electromagnetic Exposure

Table 9-1 Box-Shaped Compliance Boundary Dimensions for General


Public/Uncontrolled (GP) Exposure for mRRUS with 1 dB
tolerance and 0 dB transmission loss (intended markets:
USA/Canada).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the RRU Distance in Distance
(external radio unit) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case84 from the radio
B2 (1900),
KRE 101 2141/1, W/L 2×5W 0.8 0.8 0.9 0.2
Vertical
B2 (1900),
KRE 101 2141/1, W/L 2×5W 0.7 0.9 0.8 0.2
Horizontal
B2 (1900),
KRE 101 2233/1, W/L 2×5W 0.4 0.7 0.7 0.4
Vertical
B2 (1900),
KRE 101 2233/1, W/L 2×5W 0.4 0.9 0.9 0.4
Horizontal
B4 (2100),
KRE 101 2141/1, W/L 2×5W 1.0 0.9 0.9 0.2
Vertical
B4 (2100),
KRE 101 2141/1, W/L 2×5W 0.8 0.9 0.9 0.2
Horizontal
B4 (2100),
KRE 101 2024/1, W/L 2×5W 0.4 0.7 0.7 0.4
Vertical
B4 (2100),
KRE 101 2024/1, W/L 2×5W 0.5 0.9 0.9 0.5
Horizontal
B7 (2600),
KRE 101 2142/1, L 2×5W 0.5 0.7 0.9 0.2
Vertical
B7 (2600),
KRE 101 2142/1, L 2×5W 0.5 0.9 0.7 0.2
Horizontal
B7 (2600),
KRE 101 2024/1, L 2×5W 0.3 0.7 0.7 0.3
Vertical
B7 (2600),
KRE 101 2024/1, L 2×5W 0.3 0.9 0.9 0.3
Horizontal
B12 (700),
KRE 101 2134/1, L 2×5W 1.0 0.8 0.9 0.2
Vertical
B12 (700),
KRE 101 2134/1, L 2×5W 1.0 0.9 0.8 0.2
Horizontal
B12 (700),
KRE 101 2245/1, L 2×5W 0.5 1.1 1.1 0.5
Horizontal
B13 (750),
KRE 101 2135/1, L 2×5W 1.1 1.0 1.0 0.2
Vertical
B13 (750),
KRE 101 2135/1, L 2×5W 1.2 1.0 1.0 0.2
Horizontal
B13 (750),
KRE 101 2245/1, L 2×5W 0.6 1.2 1.2 0.6
Horizontal

84 The installation case refers to the orientation of the equipment.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 31 (50)
Radio Frequency Electromagnetic Exposure

Table 9-2 Box-Shaped Compliance Boundary Dimensions for General


Public/Uncontrolled (GP) Exposure for mRBS with 1 dB tolerance
and 0 dB transmission loss (intended markets: USA/Canada).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the mRBS Distance in Distance
(micro-RBS) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case85 from the radio
B2 (1900),
KRE 101 2141/1, W/L 2×5W 1.0 0.9 1.0 0.2
Vertical
B2 (1900),
KRE 101 2141/1, W/L 2×5W 0.9 1.0 0.9 0.2
Horizontal
B2 (1900),
KRE 101 2233/1, W/L 2×5W 0.6 0.8 0.8 0.6
Vertical
B2 (1900),
KRE 101 2233/1, W/L 2×5W 0.4 1.0 1.0 0.4
Horizontal
B4 (2100),
KRE 101 2141/1, W/L 2×5W 0.8 0.9 0.9 0.2
Vertical
B4 (2100),
KRE 101 2141/1, W/L 2×5W 0.8 0.9 0.9 0.2
Horizontal
B4 (2100),
KRE 101 2024/1, W/L 2×5W 0.4 0.7 0.7 0.4
Vertical
B4 (2100),
KRE 101 2024/1, W/L 2×5W 0.3 0.9 0.9 0.3
Horizontal
B7 (2600),
KRE 101 2142/1, L 2×5W 0.6 0.8 0.9 0.2
Vertical
B7 (2600),
KRE 101 2142/1, L 2×5W 0.5 0.9 0.8 0.2
Horizontal
B7 (2600),
KRE 101 2024/1, L 2×5W 0.3 0.8 0.8 0.3
Vertical
B7 (2600),
KRE 101 2024/1, L 2×5W 0.3 0.9 0.9 0.3
Horizontal
B12 (700),
KRE 101 2134/1, L 2×5W 1.0 0.9 0.9 0.2
Vertical
B12 (700),
KRE 101 2134/1, L 2×5W 1.1 0.9 0.9 0.2
Horizontal
B12 (700),
KRE 101 2245/1, L 2×5W 0.5 1.1 1.1 0.5
Horizontal
B13 (750),
KRE 101 2135/1, L 2×5W 1.0 1.1 0.9 0.2
Vertical
B13 (750),
KRE 101 2135/1, L 2×5W 1.1 0.9 1.1 0.2
Horizontal
B13 (750),
KRE 101 2245/1, L 2×5W 0.6 1.2 1.2 0.6
Horizontal
B25 (1900),
KRE 101 2141/1, L 2×5W 0.9 0.8 0.9 0.2
Vertical
B25 (1900),
KRE 101 2141/1, L 2×5W 0.9 0.9 0.8 0.2
Horizontal

85 The installation case refers to the orientation of the equipment.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 32 (50)
Radio Frequency Electromagnetic Exposure

Dimensions of the box-shaped compliance boundary (m)


Mode and output power for the mRBS Distance in Distance
(micro-RBS) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case85 from the radio
B25 (1900),
KRE 101 2233/1, L 2×5W 0.5 0.9 0.9 0.5
Vertical
B25 (1900),
KRE 101 2233/1, L 2×5W 0.4 1.0 1.0 0.4
Horizontal

Table 9-3 Box-Shaped Compliance Boundary Dimensions for General


Public/Uncontrolled (GP) Exposure for Radio 2203 with 0.6 dB
tolerance and 0 dB transmission loss (intended market: USA)
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the mRRU Distance in Distance
(micro-RRU) front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case89 from the radio
B2/25 (1900)
KRE 101 2249/1, W/L 2×5W 0.7 0.6 0.6 0.2
Vertical
B2/25 (1900)
KRE 101 2233/1, W/L 2×5W 0.3 0.9 0.9 0.3
Vertical
B2/25 (1900)
KRE 101 2245/1, W/L 2×5W 0.3 0.9 0.9 0.3
Vertical
B5 (850)
KRE 101 2199/1, W/L 2×5W 0.7 0.6 0.6 0.2
Vertical
B5 (850)
KRE 101 2233/1, W/L 2×5W 0.3 1.0 1.0 0.4
Vertical
B66A (2100) ,
KRE 101 2249/1 W86/L 2×5W 0.8 0.6 0.6 0.2
Vertical
B66A (2100),
KRE 101 2233/1, W90/L 2×5W 0.2 0.9 0.9 0.3
Vertical
B66A (2100),
KRE 101 2245/1, W90/L 2×5W 0.3 0.9 0.9 0.3
Vertical

Table 9-4 Box-Shaped Compliance Boundary Dimensions for General


Public/Uncontrolled (GP) Exposure for Radio 2203 with 0.6 dB
tolerance and 0 dB transmission loss (intended market: Canada)
Mode and output power for the mRRU Dimensions of the box-shaped compliance boundary (m)
(micro-RRU)

86 For WCDMA/UMTS the Radio 2203 B66A is limited to B4 frequencies.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 33 (50)
Radio Frequency Electromagnetic Exposure

Distance in Distance
front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case89 from the radio
B2/25 (1900)
KRE 101 2249/1, W/L 2×5W 1.2 1.0 1.0 0.2
Vertical
B2/25 (1900)
KRE 101 2233/1, W/L 2×5W 0.4 1.0 1.0 0.5
Vertical
B2/25 (1900)
KRE 101 2245/1, W/L 2×5W 0.4 1.1 1.1 0.5
Vertical
B5 (850)
KRE 101 2199/1, W/L 2×5W 1.2 1.0 1.0 0.2
Vertical
B5 (850)
KRE 101 2233/1, W/L 2×5W 0.6 1.6 1.6 0.8
Vertical
B7 (2600)
KRE 101 2250/1 W/L 2×5W 1.1 0.9 0.9 0.2
Vertical
B7 (2600)
KRE 101 2233/1 W/L 2×5W 0.3 0.9 0.9 0.4
Vertical
B7 (2600)
KRE 101 2245/1 W/L 2×5W 0.3 0.9 0.9 0.3
Vertical
B66A (2100),
KRE 101 2249/1, W90/L 2×5W 1.4 1.0 1.0 0.2
Vertical
B66A (2100),
KRE 101 2233/1, W90/L 2×5W 0.5 1.1 1.1 0.5
Vertical
B66A (2100),
W90/L 2×5W
KRE 101 2245/1, 0.6 1.1 1.1 0.6
Vertical

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 34 (50)
Radio Frequency Electromagnetic Exposure

Table 10-1 Characteristics for the tested internal antennas used with mRRUS,
mRBS, RRU 2208, Radio 2203 and Radio 2205.
Internal X-pol Internal X-pol Internal X-pol Internal X-pol Internal X-pol
Antenna sector coverage sector coverage sector coverage sector coverage sector coverage
specifications antenna antenna antenna antenna antenna
(KRE 101 2141/1) (KRE 101 2135/1) (KRE 101 2142/1) (KRE 101 2134/1) (KRE 101 2142/2)
Antenna
dimensions — — — — —
(m)
Half-power
beam width 68 – 81 79 – 92 93 – 108 86 - 106 76 - 96
(degrees)
Antenna gain
5.8 – 7.9 5.3 – 6.6 4.8 – 5.4 5.2 – 6.7 6.8 – 6.1
(dBi)
Down tilt
— — — — —
(degrees)
B1, B2, B3, B4,
Tested bands B13 B7 B12 B38
B25

Internal X-pol Internal X-pol Internal X-pol Internal X-pol Internal X-pol
Antenna sector coverage sector coverage sector coverage sector coverage sector coverage
specifications antenna antenna antenna antenna antenna
(KRE 101 2150/2) (KRE 101 2249/1) (KRE 101 2199/1) (KRE 101 2250/1) (KRE 105 259/1)
Antenna
dimensions — — — — —
(m)
Half-power
beam width 65 ± 10 85 — 82 ± 13
90º ± 10º
(degrees)
Antenna gain
> 10 > 7.5 6.9, 6.5 > 7.5 10.5
(dBi)
Down tilt
— 8 — 8 —
(degrees)
B1, B2, B3, B25,
Tested bands B41 B5, B8 B7 B46A
B66A

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 35 (50)
Radio Frequency Electromagnetic Exposure

Table 10-2 Characteristics for the tested external antennas used with mRRUS,
mRBS, RRU 2208 and Radio 2203.
External X-pol External X-pol
External V-pol omni- External V-pol omni- External V-pol omni-
Antenna sector coverage sector coverage
directional antenna directional antenna directional antenna
specifications antenna antenna
(KRE 101 2024/1) (KRE 101 2245/1) (KRE 101 2233/1)
(KRE 101 2085/1) (KRE 101 1985/1)
Antenna
dimensions Height: 1.4 Height: 1.3 Height: 0.12 Height: 0.2 Height: 0.19
(m)
Half-power
beam width 58 64 – 68 omni omni omni
(degrees)
Antenna gain
19.0 17.7 - 18 2 2 2
(dBi)
Down tilt
0 0 — — —
(degrees)
B2, B7, B12, B13,
Tested bands B7 B1, B3 B1, B3, B4, B7 B2, B7, B25, B66A
B25, B66A

External V-pol omni-


Antenna
directional antenna
specifications
(KRE 101 2266/1)
Antenna
dimensions Height: 0.19
(m)
Half-power
beam width Omni
(degrees)
Antenna gain
2
(dBi)
Down tilt

(degrees)
Tested bands B1, B3, B5, B7, B8

Table 10-3 Characteristics for the tested antennas used with RRU 22F3.
External V-pol omni-
Antenna
directional antenna
specifications
(KRE 101 2245/1)
Antenna
dimensions Height: 0.2
(m)
Half-power
beam width omni
(degrees)
Antenna gain
2
(dBi)
Down tilt

(degrees)
Tested bands B1, B18, B28

Table 11-1 Total Power to the mRRUS, mRBS, RRU 2208, Radio 2203, and
Radio 2205 antennas.
Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm/W) to the antenna (dBm/W)

B1 (2100) W/L 40 / 10 41 / 12.6

B2 (1900) W/L 40 / 10 41 / 12.6

B3 (1800) W/L 40 / 10 41 / 12.6

B4 (2100) W/L 40 / 10 41 / 12.6

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 36 (50)
Radio Frequency Electromagnetic Exposure

Nominal output power from the Upper limit of power delivered


Band Standard
radio (dBm/W) to the antenna (dBm/W)

B5 (850)87 W/L 40 / 10 41 / 12.6

B5 (850)88 W/L 40 / 10 40.6 / 11.5

B7 (2600) L 40 / 10 41 / 12.6

B8 (900) W/L 40 / 10 41 / 12.6

B12 (700) L 40 / 10 41 / 12.6

B13 (750) L 40 / 10 41 / 12.6

B25 (1900) W/L 40 / 10 41 / 12.6

B38 (2600) L 40 / 10 41 / 12.6

33 / 2.0 34 / 2.5
B41 (TD 2500) L
43 / 20 44 / 25

B46A (5000) L 11.5 / 0.014 12.5 / 0.018

B66A (2100) W/L 40 / 10 40.6 / 11.5

Table 11-2 Total Power to the RRU 22F3 antennas.


Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm/W) to the antenna (dBm/W)

B1 (2100) L 12 / 40.889 13 / 41.293

B18 (800) L 8.0 / 39.093 8.7 / 39.493

B28 (700) L 8.0 / 39.093 8.7 / 39.493

87 For configurations with 1 dB power tolerance and 0 dB transmission loss.


88 For configurations with 0.6 dB power tolerance and 0 dB transmission loss.
89 This row shows the result for RRU 22F3 with simultaneous operation on B1, B18 and B28 with power

ratios of 42.9 %, 28.6 % and 28.6 %, respectively.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 37 (50)
Radio Frequency Electromagnetic Exposure

According to FCC and Innovation, Science and Economic Development


Canada requirements, of relevance for the USA and Canada, Radio 2205 may
be classified as a mobile device with an intended separation distance to the
user or nearby persons of at least 20 cm. Conducted EMF tests have
confirmed that the exposure levels are below the exposure limits at 20 cm
separation distance for the internal and external antenna configurations in
Table 12

Table 12 Characteristics for the tested configurations of Radio 2205 with


compliance confirmed at 20 cm separation distance.
Internal X-pol sector coverage External X-pol omni-directional
Antenna
antenna antenna
specifications
(KRE 105 259/1) (Galtronics P6480i)
Antenna dimensions
— Height: 0.63
(m)
Horizontal half-power
beam width 90º ± 10º omni
(degrees)
Vertical half-power
30º ± 5º 19
beam width (degrees)
Antenna gain
10.5 6
(dBi)
Tested bands B46 B46

Standard L L
Nominal output power
from the radio (24 / 0.25) (28.5 / 0.71)
(dBm/W)

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 38 (50)
Radio Frequency Electromagnetic Exposure

2.3 Pico RBS


For EU and markets other than US and Canada, box-shaped compliance
boundaries have been determined with the front and back compliance
distances defined from the equipment casing as shown in Figure 5. The widths
and heights are specified including the dimensions of the product.

Figure 5. Box-shaped Compliance Boundary. The front and back compliance


distances are defined from the equipment casing.

For ceiling mounted external antennas, cylinder-shaped compliance


boundaries have been determined with the front, back and radial compliance
distances defined relative to the equipment casing as shown in Figure 6.

Figure 6. Cylinder-shaped Compliance Boundary. The compliance distances


are defined relative to the equipment casing.

The compliance boundary dimensions in meters are shown in Table 13. The
power levels used for the assessments include power tolerances and
transmission losses where applicable. The expanded uncertainty (k=2) for the
underlying specific absorption rate (SAR) and field strength measurements is
less than 30%.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 39 (50)
Radio Frequency Electromagnetic Exposure

The nominal power levels (excluding tolerances) are given in

Table 14.

According to FCC and Innovation, Science and Economic Development


Canada requirements, of relevance for the USA and Canada, a Pico RBS is to
be classified as a mobile device with an intended separation distance to the
user or nearby persons of at least 20 cm. Conducted EMF tests have
confirmed that the exposure levels are below the exposure limits at 20 cm
separation distance for the internal and external antennas used individually or
combined, see Table 15.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 40 (50)
Radio Frequency Electromagnetic Exposure

Table 13-1 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for RBS 6401 with the
internal antenna KRE 101 2139/1 with 0.6 dB power tolerance and
0 dB transmission loss. (Intended markets: Europe/Rest of world
(RoW)).
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for the RBS
(radio base station) Distance in Distance
Width Height
front of EUT behind EUT
Nominal output
3GPP band Standard power from the GP O GP O GP O GP O
radio

B1 (2100) W 2×1W 0.20 0.06 0.2690 0.2694 0.4291 0.4295 0 0

W 2×1W

B1 (2100) WiFi 2.4 GHz 0.1 W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0

WiFi 5 GHz 0.25 W

B1 (2100) L 2×1W 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0

L 2×1W
B1 (2100) WiFi 2.4 GHz 0.1 W 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
WiFi 5 GHz 0.25 W
B2
W 2×1W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0
(1900)

W 2×1W

B2 WiFi FCC-RoW
0.1 W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0
(1900) 2.4 GHz
WiFi FCC-RoW
0.25 W
5 GHz
B2
L 2×1W 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
(1900)
L 2×1W
WiFi FCC-RoW
B2 0.1 W
2.4 GHz 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
(1900)
WiFi FCC-RoW
0.25 W
5 GHz

Table 13-2 Box-Shaped Compliance Boundary Dimensions for General Public


(GP) and Occupational (O) Exposure for RBS 6402 with the
internal antenna KRE 105 660/1 with 0.6 dB power tolerance and
0 dB transmission loss. (Intended markets: Europe/Rest of world
(RoW)).

90 Same as product width. This implies that there is no compliance distance to the side of the product.
91 Same as product height. This implies that there is no compliance distance above or below the product.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 41 (50)
Radio Frequency Electromagnetic Exposure

Dimensions of the box-shaped compliance boundary (m)


Mode and output power for the RBS
(radio base station) Distance in Distance
Width Height
front of EUT behind EUT
3GPP/ Wi-Fi band & Nominal output
hardware Standard power from the GP O GP O GP O GP O
configuration type radio
B1 (2100)
W 2 × 0.25 W 0 0 0.2894 0.2894 0.1795 0.1795 0 0
without fan module
B1 (2100)
W 2 × 0.25 W 0 0 0.2894 0.2894 0.1995 0.1995 0 0
with fan module
B7 (2600)
L 2 × 0.25 W 0 0 0.2894 0.2894 0.1795 0.1795 0 0
without fan module
B7 (2600)
L 2 × 0.25 W 0 0 0.2894 0.2894 0.1995 0.1995 0 0
with fan module
B1 (2100), B3 (1800)
or B7 (2600)
combined with B1 L 4 × 0.25 W 0.02 0.01 0.31 0.30 0.21 0.21 0 0
(2100), B3 (1800) or
B7 (2600)
B1 (2100), B3 (1800)
2 × 0.25 W (B1, B3,
or B7 (2600)
B7)
combined with B46A L 0.01 0 0.30 0.2851 0.1952 0.1952 0 0
2 × 0.025 W (B46A)
(5200), or B46D
2 × 0.13 W (B46D)
(5800)
B1 (2100), B3 (1800)
or B7 (2600)
combined with B1 L 4 × 0.25 W
(2100), B3 (1800) or Wi-Fi 2 GHz 3 × 0.40 W 0.02 0.01 0.30 0.29 0.20 0.20 0 0
B7 (2600) and Wi-Fi Wi-Fi 5 GHz 3 × 0.50 W
2 GHz and Wi-Fi
5GHz

Table 13-3 Dimensions of the cylinder-shaped compliance boundary for


general public (GP) and occupational (O) exposure for the
RBS 6402 with the external cellular antennas with 0.6 dB output
power tolerance and connected with the supplied transmission
cable. (Intended markets: Europe/Rest of world (RoW)).
Dimensions of the cylinder-shaped compliance boundary (m)
Mode and output power for the equipment under test
(EUT) Distance in Distance in radial Distance behind
front of EUT direction EUT
Nominal output
3GPP band Standard power from the GP O GP O GP O
radio

B1 (2100) W/L 2 × 0.25 W 0 0 0 0 0 0

B3 (1800) L 2 × 0.25 W 0 0 0 0 0 0

B7 (2600) L 2 × 0.25 W 0 0 0 0 0 0

Table 14-1 RBS 6401 Nominal Power Levels.


Nominal output power from the
Band Standard
radio (dBm/W)

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 42 (50)
Radio Frequency Electromagnetic Exposure

B1 (2100) W/L 33/2

B2, B25 (1900) W/L 33/2

WiFi, 2.4 GHz


B1 (2100) 20/0.1
FCC- RoW

WiFi, 5 GHz
B1 (2100) 24/0.2592
FCC- RoW

WiFi, 2.4 GHz


B2, B25 (1900) 20/0.1
FCC- RoW

WiFi, 5 GHz
B2, B25 (1900) 24/0.2596
FCC- RoW

Table 14-2 RBS 6402 Nominal Power Levels.


Nominal output power from the
Band Standard
radio (dBm/W)

B1 (2100) W/L 27/0.593

B2 (1900) W 27/0.597

B2,25 (1900) L 27/0.597

B2,25 (1900) L 30/194

B3 (1800) L 27/0.595

B4(2100) W/L 27/0.597

B4(2100) L 30/198

B7 (2600) L 27/0.597

B7 (2600) L 30/198

B1 (2100), B3 (1800) or B7
(2600) combined with B1 (2100), L 30/198
B3 (1800) or B7 (2600)

B2,25 (1900), B4 (2100) or B7


(2600) combined with B46A L 28.8/0.75
(5200)

92 The power level provided corresponds to the maximum power among the available bands.
93 This output power value corresponds to the EUT with one RF card installed or to the configuration with
an external antenna.
94 This output power value corresponds to the EUT with both RF cards installed.
95 This output power value corresponds to the configuration with an external antenna.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 43 (50)
Radio Frequency Electromagnetic Exposure

Nominal output power from the


Band Standard
radio (dBm/W)

B2,25 (1900), B4 (2100) or B7


(2600) combined with B46D L 28.8/0.75
(5700)

B1 (2100), B3 (1800) or B7
(2600) combined with B46A L 27.4 / 0.55
(5200)

B1 (2100), B3 (1800) or B7
(2600) combined with B46D L 28.8 / 0.75
(5800)

B1 (2100), B3 (1800) or B7
(2600) combined with B1 (2100),
L + Wi-Fi 31/1.2796
B3 (1800) or B7 (2600) and
Wi-Fi 2 GHz and Wi-Fi 5GHz

B2,25 (1900), B4 (2100) or B7


(2600) combined with B2,25
(1900), B4 (2100) or B7 (2600) W/L + Wi-Fi 31/1.27100
and Wi-Fi 2 GHz and Wi-Fi
5GHz

Table 15-1 Characteristics for the tested antennas used with RBS 6401 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Internal X-pol sector coverage External V-pol omni-directional
Antenna
antenna antenna
specifications
(KRE 101 2139/1) (KRE 101 2024/1)
Antenna dimensions
— Height: 0.12
(m)
Half-power beam
width 62 – 105 omni
(degrees)
Antenna gain
6.4-8.3 2
(dBi)
Tested bands B1, B2, B25 B2, B25

Table 15-2 Characteristics for the tested antennas used with RBS 6402 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
External H/V
Internal PIFA
Antenna Internal antenna Internal antenna linearly polarized
antenna
specifications (KRE 105 211/1) (KRE 105 211/2) antenna
(KRE 105 660/1)
(Laird CMD69273)
Diameter 219 mm
Antenna × Height 94mm /
dimensions — — — Height extending
(m) beneath the ceiling
44 mm
Half-power beam
width — — — —
(degrees)
Antenna gain 5.0 B2/B4/B25
4.5 (Max) 6 (Max) 6 (Max)
(dBi) 5.6 B7
B46A, B46D,
Wi-Fi 2.4 GHz,
Tested bands B2 ,B4, B7, B25 Wi-Fi 2.4 GHz, B2, B4, B7, B25
Wi-Fi 5 GHz
Wi-Fi 5 GHz

96
This output power values corresponds to the configuration with two cellular band RF-cards and one
Wi-Fi RF-card.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 44 (50)
Radio Frequency Electromagnetic Exposure

2.4 Radio Dot System


For EU and countries other than USA and Canada, cylinder-shaped
compliance boundaries are defined with the front, back and radial compliance
distances relative to the equipment casing as shown in Figure 7.

Figure 7. Cylinder-shaped Compliance Boundary. The


compliance distances are defined relative to the equipment
casing.

The compliance boundary dimensions for the Radio Dot, in meters, are shown
in Table 16, Table 17 and Table 18. A distance of zero means that the radio
head is compliant at the surface. The power levels used for the assessments
include power tolerances and transmission losses. The expanded uncertainty
(k=2) for the underlying SAR measurements is less than 30%. The total
power fed to the antennas for RD 2242, RD 4442 and RD 2243 (including
tolerance) is given in Table 19, Table 20, and Table 21, respectively.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 45 (50)
Radio Frequency Electromagnetic Exposure

Table 16 Cylinder-Shaped Compliance Boundary Dimensions for General


Public (GP) and Occupational (O) Exposure for RD 2242. A 2 dB
power tolerance and 0 dB transmission loss is assumed. (intended
markets: Europe/Rest of world (RoW)).
Dimensions of the cylinder-shaped compliance
boundary (m)
Mode and output power for the RBS
(radio base station) Distance in Distance in the
front of radio Radial distance back of the
head radio head
Nominal output
3GPP band Standard GP O GP O GP O
power from the radio

B1 (2100) W/L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

B3 (1800) L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

B7 (2600) L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

B40 (2300) L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

Table 17 Cylinder-Shaped Compliance Boundary Dimensions for General


Public (GP) and Occupational (O) Exposure for RD 4442. A 2 dB
power tolerance and 0 dB transmission loss is assumed. (intended
markets: Europe/Rest of world (RoW)).
Dimensions of the cylinder-shaped compliance
boundary (m)
Mode and output power for the RBS
(radio base station) Distance in Distance in the
front of radio Radial distance back of the
head radio head
Nominal output
3GPP band Standard power from the GP O GP O GP O
radio97
B1 (2100) B1: W/L B1: 2 × 0.05 W
0.0 0.0 0.0 0.0 0.0 0.0
B3 (1800) B3: L B3: 2 × 0.05 W
B1 (2100) B1: W/L B1: 2 × 0.05 W
0.0 0.0 0.0 0.0 0.0 0.0
B7 (2600) B7: L B7: 2 × 0.05 W
B3 (1800) B3: L B3: 2 × 0.05 W
0.0 0.0 0.0 0.0 0.0 0.0
B7 (2600) B7: L B7: 2 × 0.05 W

97 Simultaneous operation on two radio bands

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 46 (50)
Radio Frequency Electromagnetic Exposure

Table 18 Cylinder-Shaped Compliance Boundary Dimensions for General


Public (GP) and Occupational (O) Exposure for RD 2243. A 2 dB
power tolerance and 0 dB transmission loss is assumed. (intended
markets: China, Europe/Rest of world (RoW)).
Dimensions of the cylinder-shaped compliance
boundary (m)
Mode and output power for the RBS
(radio base station) Distance in Distance in the
front of radio Radial distance back of the
head radio head
Nominal output
3GPP band Standard power from the GP O GP O GP O
radio

B1 (2100) W/L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

B3 (1800) W/L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

B7 (2600) L 2 × 0.05 W 0.0 0.0 0.0 0.0 0.0 0.0

0.01 (H&T) 98
B40A (2300) L 2 x 0.125 W 0.0 0.0 0.0 0.0 0.0
0.0 (L)99

Table 19 RD 2242 Nominal Power Levels.


Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm/W) to the antennas (dBm/W)
B1 (2100) W/L 20 / 0.1 22 / 0.16

B2 (1900) W/L 20 / 0.1 22 / 0.16

B2 (1900)100 L 17 / 0.05 19 / 0.08

B3 (1800) L 20 / 0.1 22 / 0.16

B4 (2100) L 20 / 0.1 22 / 0.16

B4 (2100)101 L 17 / 0.05 19 / 0.08

B5 (850) L 20 / 0.1 22 / 0.16

B7 (2600) L 20 / 0.1 22 / 0.16

B13 (700) L 20 / 0.1 22 / 0.16

B17a (700) L 20 / 0.1 22 / 0.16

B40 (2300) L 20 / 0.1 22 / 0.16

98 Head and Trunk exposure


99 Limbs exposure
100 Power levels with hardened casing
101 Power levels with hardened casing

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 47 (50)
Radio Frequency Electromagnetic Exposure

Table 20 RD 4442 Nominal Power Levels.


Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm / W)102 to the antennas (dBm / W)103
B1 (2100) B1: W/L
23 / 0.2 25 / 0.32
B3 (1800) B3: L
B1 (2100) B1: W/L
23 / 0.2 25 / 0.32
B7 (2600) B7: L
B3 (1800) B3: L
23 / 0.2 25 / 0.32
B7 (2600) B7: L

Table 21 RD 2243 Nominal Power Levels.


Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm / W) to the antennas (dBm / W)
B1 (2100) W/L 20 / 0.1 22 / 0.16

B3 (1800) W/L 20 / 0.1 22 / 0.16

B7 (2600) L 20 / 0.1 22 / 0.16

B40A (2300) L 24 / 0.25 26 / 0.40

According to FCC and Innovation, Science and Economic Development


Canada requirements, of relevance for USA and Canada, a Radio Dot may be
classified as a mobile device with an intended separation distance to the user
or nearby persons of at least 20 cm. Conducted EMF tests have confirmed
that the RF exposure levels are below the exposure limits at 20 cm separation
from the radio head, see Table 22, Table 23, and Table 24.

102 Simultaneous operation on two radio bands


103 Simultaneous operation on two radio bands

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 48 (50)
Radio Frequency Electromagnetic Exposure

Table 22 Characteristics for the tested antennas used with RD 2242 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B2 3
(KRE 101 2191/2)
Internal sector coverage antenna
B2 4.75
(KRE 101 2191/2)104
Internal sector coverage antenna
B4 2.5
(KRE 101 2191/2)
Internal sector coverage antenna
B4 2.7
(KRE 101 2191/2)105
Internal sector coverage antenna
B5 -0.4
(KRE 101 2187/1)
Internal sector coverage antenna
B13 -2.0
(KRE 101 2185/1)
Internal sector coverage antenna
B17a -2.6
(KRE 101 2184/2)

Table 23 Characteristics for the tested antennas used with RD 2243 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B41 3.8
(KRE 101 2342/1)
Internal sector coverage antenna
B25 1.8
(KRE 101 2309/1)
Internal sector coverage antenna
B66A 2.9
(KRE 101 2309/1)

Table 24 Characteristics for the tested antennas used with RD 4442 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B25, B66A 1.8, 2.9
(KRE 101 2309/1)
Internal sector coverage antenna
B48 3
(KRE 101 2311/1)

104 The maximum gain obtained with hardened casing


105 The maximum gain obtained with hardened casing

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 49 (50)
Radio Frequency Electromagnetic Exposure

References

[1] ICNIRP, “Guidelines for limiting exposure to time-varying electric,


magnetic, and electromagnetic fields (up to 300 GHz)”, International
Commission on Non-Ionizing Radiation Protection (ICNIRP), Health
Physics, vol. 74, pp 494-522, April 1998.
[2] FCC, Code of Federal Regulations CFR title 47, part 1.1310
“Radiofrequency radiation exposure limits”, Federal Communications
Commission (FCC), August 1997.
[3] Industry Canada, Radio Standard Specification (RSS) 102, “Radio
Frequency Exposure Compliance of Radiocommunication Apparatus
(All Frequency Bands)”, 2015.
[4] EN 50385, “Product standard to demonstrate the compliance of base
station equipment with radio frequency electromagnetic field exposure
limits (110 MHz – 100 GHz), when placed on the market”, European
Committee for Electrotechnical Standardization (CENELEC), 2017.
[5] EN/IEC 62232:2017, Determination of RF field strength, power density
and SAR in the vicinity of radiocommunication base stations for the
purpose of evaluating human exposure, August 2017.
[6] Ericsson, “Radio Frequency Electromagnetic Fields”, Safety
Information, 124 46-EN/LZT 720 0399.
[7] EN 50663:2017, “Generic standard for assessment of low power
electronic and electrical equipment related to human exposure
restrictions for electromagnetic fields (0 Hz - 300 GHz)”, European
Committee for Electrotechnical Standardization (CENELEC), May
2017.

5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23  Ericsson AB 2009-2018 50 (50)