Rus Specification
Rus Specification
Rus Specification
Safety Information
Copyright
Disclaimer
No part of this document may be reproduced in any form without the written
permission of the copyright owner.
The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use of
this document.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 2 (50)
Radio Frequency Electromagnetic Exposure
Contents
1 Introduction...............................................................................4
References.................................................................................................51
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 3 (50)
Radio Frequency Electromagnetic Exposure
1 Introduction
This document provides information on Radio Frequency (RF)
Electromagnetic Field (EMF) exposure from antennas either integrated in or
connected to a radio base station (RBS) or a radio unit in the RBS 6000
family.
The distance between the back of the antenna and the cylinder/box is the
"Distance behind antenna". The height of the cylinder/box is the antenna
height plus a certain, equal distance above and below the antenna. For a box-
shaped compliance boundary the ‘Width’ represents the width of the box.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 4 (50)
Radio Frequency Electromagnetic Exposure
It should be noted that Table 1 through Table 3 show examples for specified
typical antennas and for minimum and maximum power levels, including the
power tolerances and assumed transmission losses. As the antenna field
distributions will differ for other antennas and power levels, calculations or
measurements may be necessary to establish the compliance boundary for
other configurations chosen by the customer. Other calculations or
measurements may also be required if exposure limits other than [1] or [2] are
specified in national regulations. For further information on RF exposure
assessment methods, see [6].
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 5 (50)
Radio Frequency Electromagnetic Exposure
Characteristics of the antennas recommended and tested for macro RBS 6000
configurations are listed in Table 4.
The total powers fed to the antennas (including tolerance and assumed
transmission loss) are given in Table 5 for using RU, Table 6-1, Table 6-2 and
Table 6-3 for using RRU and Table 7-1 and 7-2 for using AIR.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 6 (50)
Radio Frequency Electromagnetic Exposure
Table 1-2 Box Shaped Compliance Boundary Dimensions for General Public
(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Power Configurations with MIMO using RU (Internal Radio
Unit) with 0.6 dB Tolerance and Assumed 3 dB Transmission
Loss.
Dimensions of the box-shaped compliance boundary (m)
Mode and output power for RU (internal radio unit) Distance in
using MIMO antenna and 0.6 dB tolerance Distance
front Width Height
behind antenna
of antenna
Nominal
Number of output power
Band Standard GP O GP O GP O GP O
Tx/Rx from
the radio
B13 (700) L 4 240 W 16 7.1 12.6 5.4 3.2 2.2 0.1 0.1
Table 1-3 Box Shaped Compliance Boundary Dimensions for General Public
(GP) and Occupational (O) Exposure for Minimum and Maximum
Output Power Configurations with MIMO using more than one RU
(Internal Radio Unit) with 0.6 dB Tolerance and Assumed 3 dB
Transmission Loss.
Dimensions of the box-shaped compliance
boundary (m)
Mode and output power for configurations with more than one RRU (external
Distance Distance
radio unit) with 0.6 dB tolerance and 0.5 dB transmission loss
in front Width Height behind
of antenna antenna
Nominal output IEC 62232
Product name Band Standard power from the installation GP O GP O GP O GP O
radios class
4 x RUS 01 B4 (2100) L 4 x 60 W E+ 11.7 4.8 9.1 3.2 3.3 1.5 <0.1 <0.1
4 x RUS 02 B2 (1900) L 4 x 80 W E+ 12.6 5.4 10.1 4.5 3.7 1.7 <0.1 <0.1
4 x RUS 02 B5 (800) L 4 x 100 W E+ 17.9 8.0 13.8 6.2 3.2 2.0 <0.2 <0.1
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 7 (50)
Radio Frequency Electromagnetic Exposure
2 This row shows results for the KRE 101 1985/1 antenna
3 This row shows results for the KRE 101 2085/1 v02 antenna.
4 This row shows results for the KRE 101 1985/1 antenna
5 This row shows results for the KRE 101 2085/1 v02 antenna.
6 KRE 101 2085/1 v02 transmits simultaneously on B1 and B3 with the power divided equally among the
two bands
7 This row shows results for the KRE 101 2085/1 v02 antenna.
8 This row shows the compliance boundary obtained with the X-pol macro RBS directional antenna
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 8 (50)
Radio Frequency Electromagnetic Exposure
10 This row shows the result for RRU 22F2 with operation on B18 and B28 with power ratios of 60 % and
40 % on these bands, respectively.
11 This row shows the results for RRU 22F1.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 9 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 10 (50)
Radio Frequency Electromagnetic Exposure
B2 (1900) /
B66A (2100) L 4 280 W 11.2 4.7 9.2 3.2 3.0 1.5 0.3 0.1
15
15 KRE 101 2294/1 (4 Tx) antenna transmits on B2 (2 Tx) and B66A (2 Tx) with power distributed as 43 %
and 57 % over the two bands, respectively.
16 This row shows the compliance boundary obtained with the X-pol macro RBS directional antenna
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 11 (50)
Radio Frequency Electromagnetic Exposure
B4017 L 4 x 40 W E+ 0.74 11.0 4.5 8.0 2.8 3.8 1.7 <0.1 <0.1
17 This row shows results for the KRE 101 2294/1 antenna.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 12 (50)
Radio Frequency Electromagnetic Exposure
18 This row shows the compliance boundary dimensions of the KRE 101 2144/1 antenna.
19 This row shows the compliance boundary dimensions of the KRE 101 2168/1 antenna.
20 This row shows the compliance boundary dimensions of the KRE 101 2132/1 antenna.
21 This row shows the compliance boundary dimensions of the KRE 101 2174/1 antenna.
22 This row shows the compliance boundary dimensions of the KRE 101 2170/1 antenna.
23 This row shows the compliance boundary dimensions of the KRE 105 244/1 antenna.
24 This row shows the compliance boundary dimensions of the KRE 101 241/1 antenna.
25 This row shows the compliance boundary dimensions of the KRE 101 2148/1 antenna.
26 This row shows the compliance boundary dimensions of the KRE 101 2166/1 antenna.
27 This row shows the compliance boundary dimensions of the KRE 105 241/1 antenna.
28 This row shows the compliance boundary dimensions of the KRE 101 2133/1 antenna.
29 This row shows the compliance boundary dimensions of the KRE 101 2149/1 antenna.
30 This row shows the compliance boundary dimensions of the KRE 101 2167/1 antenna.
31 This row shows the compliance boundary dimensions of the KRE 105 216/1 antenna.
32 This row shows the compliance boundary dimensions of the KRE 105 237/1 antenna.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 13 (50)
Radio Frequency Electromagnetic Exposure
Note: The distance behind antenna given in Table 3 is measured from the
back of the AIR radio unit.
33 KRE 105 245/1 transmits simultaneously on B3 and B7 with the power divided equally among the two
bands.
34 This row shows the compliance boundary dimensions of the KRE 101 2087/1 antenna.
35 This row shows the compliance boundary dimensions of the KRE 101 2131/1 antenna.
36 This row shows the compliance boundary dimensions of the KRE 105 241/1 antenna.
37 KRE 105 244/1 transmits simultaneously on B2 and B66 with equal power ratios.
38 KRE 105 245/1 transmits simultaneously on B7 and B66 with equal power ratios.
39 The stated EIRP value is the peak beam EIRP without power tolerance included.
40 The total EIRP for 8 beams is equal to 55 dBm i.e, above E+ power limit.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 14 (50)
Radio Frequency Electromagnetic Exposure
Tested bands B39 (MIMO only) B38, B41 (MIMO only) B0, B8 B11, B32
X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2087/1), (KRE 101 2132/1), (KRE 101 2133/1), (KRE 101 2146/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna
Height: 2.0 m Height: 1.4 m Height: 1.4 m Height: 2.0
dimensions
Half-power
66 degrees 62 degrees 62 degrees 63 degrees
beam width
Antenna gain 16 dBi 18 dBi 18 dBi 16 dBi
Tested bands B20 (AIR only) B2 (AIR only) B4 (AIR only) B8 (AIR only)
X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2149/1), (KRE 101 2144/1), (KRE 101 2148/1), (KRE 101 2166/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna
Height: 2.3 m Height: 1.4 m Height: 1.4 m Height: 2.4 m
dimensions
Half-power
60 degrees 65 degrees 65 degrees 63 degrees
beam width
Antenna gain 17 dBi 18 dBi 18 dBi 17.2 dBi
Tested bands B4 (AIR only) B1 (AIR only) B3 (AIR only) B3 (AIR only)
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 15 (50)
Radio Frequency Electromagnetic Exposure
X-pol macro RBS X-pol macro RBS X-pol macro RBS X-pol macro RBS
Antenna directional antenna directional antenna directional antenna directional antenna
specifications (KRE 101 2163/1), (KRE 101 2131/1), (KRE 101 2174/1), (KRE 101 2170/1),
Integrated in AIR Integrated in AIR Integrated in AIR Integrated in AIR
Antenna Height: 2.0 m
Height: 1.4 m Height: 1.4 m Height: 2.4 m
dimensions
Half-power 63 degrees
55 degrees 67 degrees 60 degrees
beam width
Antenna gain 18.1 dBi 14.2 dBi 16.8 dBi 17.9 dBi
Tested bands B7 (AIR only) B20 (AIR only) B2 (AIR only) B2 (AIR only)
Tested bands B18, B28, B29 B25 B4 (AIR only) B1 (AIR only)
41 The far-field properties for this antenna are given for one of the ports excited.
42 The far-field properties for this antenna correspond to values for the two array columns (broadside
beam excitation).
43 The far-field properties for this antenna correspond to values for the two array columns (broadside
beam excitation).
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 16 (50)
Radio Frequency Electromagnetic Exposure
44 Two 2 Tx antennas based on BXA-70063/6CF were used to create a 4 Tx antenna model for B14 since
70063/6CF
47 The stated gain value is the peak beam gain.
48 The information specified here is the data obtained for the 2 Tx antenna model based on BXA-
70063/6CF
49 The antenna unit consists of four Phase Array Antenna Modules (PAAM) with 2 active beams per each
PAAM.
50 The far-field properties for this antenna correspond to values for the two array columns (broadside
beam excitation).
51 The far-field properties for this antenna are given for one of the ports excited.
52 The stated gain value is the peak beam gain.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 17 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 18 (50)
Radio Frequency Electromagnetic Exposure
Table 5 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RU (Internal Radio Unit) including 0.6 dB
Tolerance and 3 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 40.6/11.5
B0 (900P) G/W/L
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B1 (2100) W/L
50.0/100 47.6/57.5
G/W/L/C 43.0/20 40.6/11.5
B2 (1900) C 49.0/80 46.6/45.7
G/W/L 50.0/100 47.6/57.5
43.0/20 40.6/11.5
B3 (1800) G/W/L
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B4 (17/2100) W/L/C
49.0/80 46.6/45.7
43.0/20 40.6/11.5
B5 (850) G/W/L/C
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B7 (2600) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
W/L
50.0/100 47.6/57.5
B8 (900E)
43.0/20 40.6/11.5
G
50.0/100 47.6/57.5
43.0/20 40.6/11.5
B11 (1500) W
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B12 (70012) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B13 (70013) L
47.8/60 45.4/34.7
B13 (70013)55 L 53.8/240 51.4/138
43.0/20 40.6/11.5
B14 (70014) L
47.8/60 45.4/34.7
43.0/20 40.6/11.5
B20 (800DD) L
49.0/80 46.6/45.7
43.0/20 40.6/11.5
B28 (700) L
50.0/100 47.6/57.5
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 19 (50)
Radio Frequency Electromagnetic Exposure
Table 6-1 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) including 0.6 dB
Tolerance and 0.5 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.1/20.4
B0 (900P) G/W/L
50.8/120 50.9/123
43.0/20 43.1/20.4
B1 (2100) W/L
52.0/160 52.1/162.2
B1 (2100) 56 W/L 52.0/160 52.1/162.2
43.0/20 43.1/20.4
B2 (1900) G/W/L
52.0/160 52.1/162.2
46.0/40 46.1/40.7
B2 (1900)57 L
52.0/160 52.1/162.2
B2 (1900) /
L 55.0/320 55.1/324
B66A (2100) 58
B2 (1900) /
L 55.0/320 55.1/324
B66A (2100)59
B2 (1900) /
L 54.5/280 54.6/288
B66A (2100) 60
43.0/20 43.1/20.4
B3 (1800) G/W/L
52.0/160 52.1/162.2
L 43.0/20 43.1/20.4
B3 (1800)61 46.0/40 46.1/40.7
G/L
52.0/160 52.1/162.2
B1 (2100),
W, G/L 52.0/160 52.1/162.2
B3 (1800)61
B1 (2100) / B3
W, L 52.0/160 52.1/162.2
(1800) 62
43.0/20 43.1/20.4
B4 (17/2100) W/L/C
50.8/120 50.9/123
46.0/40 46.1/40.7
B4 (17/2100)61 L
52.0/160 52.1/162.2
43.0/20 43.1/20.4
B5 (850) G/W/L/C
52.0/160 52.1/162.2
B5 (850)63 W/L 52.0/160 52.1/162.2
43.0/20 43.1/20.4
B7 (2600) L
50.8/120 50.9/123
46.0 / 40 46.1 / 40.7
B7 (2600)61 L
52.0 / 160 52.1 / 162.2
simultaneously on B2 (4 Tx) and B66A (4Tx) with the power distributed equally.
59 These assessments were made for an 8-branch antenna (8Tx). The product is transmitting
simultaneously on B2 (4 Tx) and B66A (4Tx) with power distributed as 25 % and 75 % over the bands,
respectively.
60 These assessments were made for a 4-branch antenna (4 Tx). The product is transmitting
simultaneously on B2 (2 Tx) and B66A (2Tx) with power distributed as 43 % and 57 % over the bands,
respectively.
61 This power level is used in a multi-band product transmitting simultaneously on B1 and B3 with the
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 20 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 21 (50)
Radio Frequency Electromagnetic Exposure
Table 6-2 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) with time-division
duplexing (TDD) including 0.6 dB Tolerance, 0.5 dB Transmission
Loss and Maximum TDD factor.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
B40 (2300) L 46 / 160 50.8 / 120
Table 6-3 Total Power to the Antenna for Minimum and Maximum Power
Configurations using RRU (External Radio Unit) including 1 dB
Tolerance and 0.5 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.5/22.4
B38 (2600) L
49.0/80 49.5/89.1
46.0/40 46.5/44.7
B38 (2600)68 L
50.8/120 51.3/134.9
46.0/40 46.5/44.7
B39 (1900)72 L
49.0/80 49.5/89.1
43.0/20 43.5/22.4
B40 (2300) L
46.0/40 46.5/44.7
46.0/40 46.5/44.7
B41(2500)72 L
53.8/240 54.3/269.2
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 22 (50)
Radio Frequency Electromagnetic Exposure
Table 7-1 Total Power to the Antenna for Minimum and Maximum Power
Configurations using AIR (Antenna Integrated Radio Unit)
including 0.6 dB Tolerance and 0 dB Transmission Loss.
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
43.0/20 43.6/22.9
B1 (2100)69 W/L
47.8/60 48.4/69.2
43.0/20 43.6/22.9
B2 (1900)70 G/W/L
47.8/60 48.4/69.2
50.8 / 120 51.4 / 138
43.0/20 43.6/22.9
G/W/L
B3 (1800)71 47.8/60 48.4/69.2
G/L 50.8 / 120 51.4 / 138
43.0/20 43.6/22.9
B4 (17/2100)72 W/L 47.8/60 48.4/69.2
50.8/120 51.4/138
43.0/20 43.6/22.9
B7 (2600) 73 L 47.8/60 48.4/69.2
50.8/120 51.4/138
B3 (1800),
G/L, L 53.8 / 240 54.4 / 275
B7 (2600)74
43.0/20 43.6/22.9
B8 (900E) G/W
47.8/60 48.4/69.2
43.0/20 43.6/22.9
B20 (800DD)75 L
47.8/60 48.4/69.2
B66 (17/2100)76 W/L 50.8 / 120 51.4 / 138
B2 (1900),
B66 G/W, W/L 53.8 / 240 54.4 / 275
(17/2100) 77
B3 (1800),
L, W/L 53.8 / 240 54.4 / 275
B7 (2600)78
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 23 (50)
Radio Frequency Electromagnetic Exposure
Table 7-2 Total Power to the Antenna for Minimum and Maximum Power
Configurations using AIR (Antenna Integrated Radio Unit)
including Tolerance, 0 dB Transmission Loss and Maximum TDD
Factor
Nominal output power from the Total power delivered to
Band Standard
radio (dBm/W) antenna (dBm/W)
B41E (2600) L 50.8 / 120 51.3 / 136
B41 (2600) L 50.8 / 120 51.8 / 151
B42 (3500) L 50.8 / 120 51.8 / 151
B257A (28000) VTF 31 / 1.3 32 / 1.6
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 24 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 25 (50)
Radio Frequency Electromagnetic Exposure
The total powers fed to the antennas (including tolerance and assumed
transmission loss) are given in Table 11.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 26 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 27 (50)
Radio Frequency Electromagnetic Exposure
80 For internal antennas and antennas mounted on the equipment, the installation case refers to the
orientation of the equipment. For external antennas not mounted on the equipment, the installation case
refers to the orientation of the antennas.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 28 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 29 (50)
Radio Frequency Electromagnetic Exposure
The maximum available power to Radio 2205, tested for B46A (5155 MHz –
5250 MHz) for the European market, including output power tolerance of 1 dB
and 0 dB transmission loss is 17.8 mW, which is less than the applicable low-
power exclusion level of 20 mW specified in [7]. As a consequence, no RF
exposure evaluation is required, and the product is inherently in compliance
with the appropriate RF exposure standards and recommendations.
82 For internal antennas and antennas mounted on the equipment, the installation case refers to the
orientation of the equipment. For external antennas not mounted on the equipment, the installation case
refers to the orientation of the antennas.
83 This row shows the result for RRU 22F3 with simultaneous operation on B1, B18 and B28 with power
ratios of 42.9 %, 28.6 % and 28.6 %, respectively. The orientation of the antennas is independent from
the orientation of the RRU.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 30 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 31 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 32 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 33 (50)
Radio Frequency Electromagnetic Exposure
Distance in Distance
front of Width Height behind
antenna/EUT antenna/EUT
Band, antenna, Nominal output power
Standard GP GP GP GP
installation case89 from the radio
B2/25 (1900)
KRE 101 2249/1, W/L 2×5W 1.2 1.0 1.0 0.2
Vertical
B2/25 (1900)
KRE 101 2233/1, W/L 2×5W 0.4 1.0 1.0 0.5
Vertical
B2/25 (1900)
KRE 101 2245/1, W/L 2×5W 0.4 1.1 1.1 0.5
Vertical
B5 (850)
KRE 101 2199/1, W/L 2×5W 1.2 1.0 1.0 0.2
Vertical
B5 (850)
KRE 101 2233/1, W/L 2×5W 0.6 1.6 1.6 0.8
Vertical
B7 (2600)
KRE 101 2250/1 W/L 2×5W 1.1 0.9 0.9 0.2
Vertical
B7 (2600)
KRE 101 2233/1 W/L 2×5W 0.3 0.9 0.9 0.4
Vertical
B7 (2600)
KRE 101 2245/1 W/L 2×5W 0.3 0.9 0.9 0.3
Vertical
B66A (2100),
KRE 101 2249/1, W90/L 2×5W 1.4 1.0 1.0 0.2
Vertical
B66A (2100),
KRE 101 2233/1, W90/L 2×5W 0.5 1.1 1.1 0.5
Vertical
B66A (2100),
W90/L 2×5W
KRE 101 2245/1, 0.6 1.1 1.1 0.6
Vertical
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 34 (50)
Radio Frequency Electromagnetic Exposure
Table 10-1 Characteristics for the tested internal antennas used with mRRUS,
mRBS, RRU 2208, Radio 2203 and Radio 2205.
Internal X-pol Internal X-pol Internal X-pol Internal X-pol Internal X-pol
Antenna sector coverage sector coverage sector coverage sector coverage sector coverage
specifications antenna antenna antenna antenna antenna
(KRE 101 2141/1) (KRE 101 2135/1) (KRE 101 2142/1) (KRE 101 2134/1) (KRE 101 2142/2)
Antenna
dimensions — — — — —
(m)
Half-power
beam width 68 – 81 79 – 92 93 – 108 86 - 106 76 - 96
(degrees)
Antenna gain
5.8 – 7.9 5.3 – 6.6 4.8 – 5.4 5.2 – 6.7 6.8 – 6.1
(dBi)
Down tilt
— — — — —
(degrees)
B1, B2, B3, B4,
Tested bands B13 B7 B12 B38
B25
Internal X-pol Internal X-pol Internal X-pol Internal X-pol Internal X-pol
Antenna sector coverage sector coverage sector coverage sector coverage sector coverage
specifications antenna antenna antenna antenna antenna
(KRE 101 2150/2) (KRE 101 2249/1) (KRE 101 2199/1) (KRE 101 2250/1) (KRE 105 259/1)
Antenna
dimensions — — — — —
(m)
Half-power
beam width 65 ± 10 85 — 82 ± 13
90º ± 10º
(degrees)
Antenna gain
> 10 > 7.5 6.9, 6.5 > 7.5 10.5
(dBi)
Down tilt
— 8 — 8 —
(degrees)
B1, B2, B3, B25,
Tested bands B41 B5, B8 B7 B46A
B66A
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 35 (50)
Radio Frequency Electromagnetic Exposure
Table 10-2 Characteristics for the tested external antennas used with mRRUS,
mRBS, RRU 2208 and Radio 2203.
External X-pol External X-pol
External V-pol omni- External V-pol omni- External V-pol omni-
Antenna sector coverage sector coverage
directional antenna directional antenna directional antenna
specifications antenna antenna
(KRE 101 2024/1) (KRE 101 2245/1) (KRE 101 2233/1)
(KRE 101 2085/1) (KRE 101 1985/1)
Antenna
dimensions Height: 1.4 Height: 1.3 Height: 0.12 Height: 0.2 Height: 0.19
(m)
Half-power
beam width 58 64 – 68 omni omni omni
(degrees)
Antenna gain
19.0 17.7 - 18 2 2 2
(dBi)
Down tilt
0 0 — — —
(degrees)
B2, B7, B12, B13,
Tested bands B7 B1, B3 B1, B3, B4, B7 B2, B7, B25, B66A
B25, B66A
Table 10-3 Characteristics for the tested antennas used with RRU 22F3.
External V-pol omni-
Antenna
directional antenna
specifications
(KRE 101 2245/1)
Antenna
dimensions Height: 0.2
(m)
Half-power
beam width omni
(degrees)
Antenna gain
2
(dBi)
Down tilt
—
(degrees)
Tested bands B1, B18, B28
Table 11-1 Total Power to the mRRUS, mRBS, RRU 2208, Radio 2203, and
Radio 2205 antennas.
Nominal output power from the Upper limit of power delivered
Band Standard
radio (dBm/W) to the antenna (dBm/W)
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 36 (50)
Radio Frequency Electromagnetic Exposure
B7 (2600) L 40 / 10 41 / 12.6
33 / 2.0 34 / 2.5
B41 (TD 2500) L
43 / 20 44 / 25
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 37 (50)
Radio Frequency Electromagnetic Exposure
Standard L L
Nominal output power
from the radio (24 / 0.25) (28.5 / 0.71)
(dBm/W)
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 38 (50)
Radio Frequency Electromagnetic Exposure
The compliance boundary dimensions in meters are shown in Table 13. The
power levels used for the assessments include power tolerances and
transmission losses where applicable. The expanded uncertainty (k=2) for the
underlying specific absorption rate (SAR) and field strength measurements is
less than 30%.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 39 (50)
Radio Frequency Electromagnetic Exposure
Table 14.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 40 (50)
Radio Frequency Electromagnetic Exposure
W 2×1W
B1 (2100) WiFi 2.4 GHz 0.1 W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0
L 2×1W
B1 (2100) WiFi 2.4 GHz 0.1 W 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
WiFi 5 GHz 0.25 W
B2
W 2×1W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0
(1900)
W 2×1W
B2 WiFi FCC-RoW
0.1 W 0.20 0.06 0.2694 0.2694 0.4295 0.4295 0 0
(1900) 2.4 GHz
WiFi FCC-RoW
0.25 W
5 GHz
B2
L 2×1W 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
(1900)
L 2×1W
WiFi FCC-RoW
B2 0.1 W
2.4 GHz 0.20 0.03 0.2694 0.2694 0.4295 0.4295 0 0
(1900)
WiFi FCC-RoW
0.25 W
5 GHz
90 Same as product width. This implies that there is no compliance distance to the side of the product.
91 Same as product height. This implies that there is no compliance distance above or below the product.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 41 (50)
Radio Frequency Electromagnetic Exposure
B3 (1800) L 2 × 0.25 W 0 0 0 0 0 0
B7 (2600) L 2 × 0.25 W 0 0 0 0 0 0
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 42 (50)
Radio Frequency Electromagnetic Exposure
WiFi, 5 GHz
B1 (2100) 24/0.2592
FCC- RoW
WiFi, 5 GHz
B2, B25 (1900) 24/0.2596
FCC- RoW
B2 (1900) W 27/0.597
B3 (1800) L 27/0.595
B4(2100) L 30/198
B7 (2600) L 27/0.597
B7 (2600) L 30/198
B1 (2100), B3 (1800) or B7
(2600) combined with B1 (2100), L 30/198
B3 (1800) or B7 (2600)
92 The power level provided corresponds to the maximum power among the available bands.
93 This output power value corresponds to the EUT with one RF card installed or to the configuration with
an external antenna.
94 This output power value corresponds to the EUT with both RF cards installed.
95 This output power value corresponds to the configuration with an external antenna.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 43 (50)
Radio Frequency Electromagnetic Exposure
B1 (2100), B3 (1800) or B7
(2600) combined with B46A L 27.4 / 0.55
(5200)
B1 (2100), B3 (1800) or B7
(2600) combined with B46D L 28.8 / 0.75
(5800)
B1 (2100), B3 (1800) or B7
(2600) combined with B1 (2100),
L + Wi-Fi 31/1.2796
B3 (1800) or B7 (2600) and
Wi-Fi 2 GHz and Wi-Fi 5GHz
Table 15-1 Characteristics for the tested antennas used with RBS 6401 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Internal X-pol sector coverage External V-pol omni-directional
Antenna
antenna antenna
specifications
(KRE 101 2139/1) (KRE 101 2024/1)
Antenna dimensions
— Height: 0.12
(m)
Half-power beam
width 62 – 105 omni
(degrees)
Antenna gain
6.4-8.3 2
(dBi)
Tested bands B1, B2, B25 B2, B25
Table 15-2 Characteristics for the tested antennas used with RBS 6402 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
External H/V
Internal PIFA
Antenna Internal antenna Internal antenna linearly polarized
antenna
specifications (KRE 105 211/1) (KRE 105 211/2) antenna
(KRE 105 660/1)
(Laird CMD69273)
Diameter 219 mm
Antenna × Height 94mm /
dimensions — — — Height extending
(m) beneath the ceiling
44 mm
Half-power beam
width — — — —
(degrees)
Antenna gain 5.0 B2/B4/B25
4.5 (Max) 6 (Max) 6 (Max)
(dBi) 5.6 B7
B46A, B46D,
Wi-Fi 2.4 GHz,
Tested bands B2 ,B4, B7, B25 Wi-Fi 2.4 GHz, B2, B4, B7, B25
Wi-Fi 5 GHz
Wi-Fi 5 GHz
96
This output power values corresponds to the configuration with two cellular band RF-cards and one
Wi-Fi RF-card.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 44 (50)
Radio Frequency Electromagnetic Exposure
The compliance boundary dimensions for the Radio Dot, in meters, are shown
in Table 16, Table 17 and Table 18. A distance of zero means that the radio
head is compliant at the surface. The power levels used for the assessments
include power tolerances and transmission losses. The expanded uncertainty
(k=2) for the underlying SAR measurements is less than 30%. The total
power fed to the antennas for RD 2242, RD 4442 and RD 2243 (including
tolerance) is given in Table 19, Table 20, and Table 21, respectively.
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 45 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 46 (50)
Radio Frequency Electromagnetic Exposure
0.01 (H&T) 98
B40A (2300) L 2 x 0.125 W 0.0 0.0 0.0 0.0 0.0
0.0 (L)99
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 47 (50)
Radio Frequency Electromagnetic Exposure
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 48 (50)
Radio Frequency Electromagnetic Exposure
Table 22 Characteristics for the tested antennas used with RD 2242 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B2 3
(KRE 101 2191/2)
Internal sector coverage antenna
B2 4.75
(KRE 101 2191/2)104
Internal sector coverage antenna
B4 2.5
(KRE 101 2191/2)
Internal sector coverage antenna
B4 2.7
(KRE 101 2191/2)105
Internal sector coverage antenna
B5 -0.4
(KRE 101 2187/1)
Internal sector coverage antenna
B13 -2.0
(KRE 101 2185/1)
Internal sector coverage antenna
B17a -2.6
(KRE 101 2184/2)
Table 23 Characteristics for the tested antennas used with RD 2243 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B41 3.8
(KRE 101 2342/1)
Internal sector coverage antenna
B25 1.8
(KRE 101 2309/1)
Internal sector coverage antenna
B66A 2.9
(KRE 101 2309/1)
Table 24 Characteristics for the tested antennas used with RD 4442 for the
compliance tests with compliance confirmed at 20 cm separation
distance.
Antenna specifications Tested bands Maximum antenna gain (dBi)
Internal sector coverage antenna
B25, B66A 1.8, 2.9
(KRE 101 2309/1)
Internal sector coverage antenna
B48 3
(KRE 101 2311/1)
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 49 (50)
Radio Frequency Electromagnetic Exposure
References
5/124 46-LZA 701 6001 Uen Rev CX 2018-02-23 Ericsson AB 2009-2018 50 (50)