Plumber
Plumber
Plumber
and connections must withstand to when ready for service? construction of a part of a large and/or complicated plumbing
A.21 kg/cm²
B.34 kg/cm² system before the entire plans and specifications for the
C.15 kg/cm²
D.8 kg/cm² whole system have been submitted or approved?
2. What type of PVC female screws for water piping is A.Restraining
septic tank to the property line of the adjoining private advantage of a salaried ____ position to complete unfairly
sewer main? level of the main sewer shall discharge into an approved
A.National Pollution Control
water tight
Commission A.Septic tank
B.Dept of Environment and Natural B.Sump
C.Cesspool
Resources D.Leaching
C.Department of
tank
Health 27. In the excreta drainage system, which of the following pipe
D.Department of Public
materials should not be used underground?
Works A.Vitrified clay pipe
20. With what standard specification must all pipe materials B.Hubless cast iron
C.Galvanized wrought iron
must conform to? D.None of the above
A.Product Strandard of the Philippines 28. What kind of concealed connections on fixtures that it is
B.Interational Producers
required to provide an access panel or utility at least 0.30
Standard
C.Philippine Standard meter in its least dimension for easy inspection and repair?
A.Slip joint
Council B.Ball and socket
D.Department of Trade and C.Hubless
D.Flanged
Industry 29. Who was awarded as the most outstanding Registered
21. If ever pipes are to pass through masonry by using pipe
Master Plumber for the Year 2011?
sleeves, how far must each pipe be from each other? A.Dave Vela
A.Minimum of three diameters, center to B.Alberto Azarcon
C.Alberto
center
B.Minimum of three diameters flushed from each Cabael
D.Thelma Cardente
hole 30. What is the type of Siamese connection that all 125-
C.Minimum of 0.15 m on
millimeter dry standpipes shall be equipped with?
centers A.Three-way
D.Maximum of two diameters flushed from each B.Two-way
C.Four-way A.Check valve
D.One-way B.Globe valve
31. Which of the following is not considered as suds-producing C.Gate valve
D.Ball valve
fixture? 39. When permitted by DENR, which of the following below is
A.Bidet
B.Kitchen sink NOT used as a basis in determining the type of the private
C.Bath tub
D.Washing sewage disposal system to be used?
A.SOIL POROSITY
machine B.GROUND WATER LEVEL
32. When can a vertical piping be considered to be wet C.NUMBER OF OCCUPANTS
D.LOCATION
vented? 40. Except on what fixture does the vent pipe opening from the
A.Between openings of vent
soil or waste pipe must not be below the weir of the trap?
pipes A.Lavatory
B.Between any two consecutive inlet B.Kitchen sink
C.Bath tub
levels D.Water closet
C.On stack vent 41. Accordingto Batas Pambansa Blg. 344, what type of urinal
D.When serving two water closets at different
should be provided for disabled persons?
levels A.WALL-HUNG TYPE
33. Where should the overflow pipe lead for overhead tank B.PEDESTAL TYPE
C.TROUGH TYPE
installed on buildings? D.NONE OF THESE
A.Soil stack 42. What is the minimum total net inlet area of roof deck drains
B.Scuppers
C.Storm drain on roof deck used as sun decks and parking decks?
D.Gutter A.Equal to the area of outlet
34. Where the number of water closets in a floor level exceeds
pipe
20, how many of these shall be provided to the disabled B.Equal to 4 times the area of outlet
persons? pipe
A.1 C.Equal to 2 times the area of outlet
B.2
C.3 pipe
D.4 D
35. Which of the following could be omitted if the trap arm Equal to 1 1/2 times the area of outlet pipe
.
changes direction that does not exceed 90 degrees? 43. What is the minimum number of approved slip joints fittings
A.Wye
B.Cleanout may be used on the putlet side of the trap?
C.Long A.Three
B.Two
sweep C.None
D.Combination of 1/8 bend and D.One
44. The appropriate sealant that will be used to cover void
wye
36. Who was the first Charter President of NAMPAP? spaces between pipes and sleeves through concrete floors
A.Antonio Mansueto Sr.
B.Comelio G. Odvina in the ground
C.Jesus Tanghal A.Bitumen
B.Epoxy
Dera C.Grease
D.Catalino C. Casupanan D.Putty
37. In sizing the grease interceptors, four elements are being 45. Of the four board subjects given for Master Plumbers
used. Two of these elements are number of meals per examination, which of this subject was originally split into
peak hour and the waste flow rate. Whta are the other two two subject?
A.Practical Problems
elemets? B.Design And Installations
A.Slope and retention time C.Plumbing
B.Storage factor and time of
Code
concentration D.Plumbing Arithmetic
C.Retention time and storage 46. Who is authorized to issue rules and regulations to carry
concentration Plumbers
38. The Building Code stated that all dry standpipe outlets shall B.Congress of the Philippines
C.President of the Philippines
be equipped with valves having substantial chains. What D.Professional Regulation Commision
47. According to the Fire Code of the Philippines what is the
kind of valve is this?
required slope of all horizontal runs of dry standpipes Code?
A.Intensity of
system for purpose of drawing?
A.10% rainfall
B.20% B.Wind direction
C.5% C.Slope of roof
D.2% D.Roof area
48. NAMPAP is a professional organization of Registered 57. According to the Code, the desgign of roof gutters is based
Master Plumber under PRC. What is the PRC accreditation on the maximum roof area. What is the shape of the gutter
number of NAMPAP? does the desgn table for storm sewer is being based to?
A.10 A.Circular
B.14 B.Restangular
C.18 C.Ovate
D.12 D.Semi-circular
49. Within how many meters away shall unions be installed 58. What kind of septic tank is prohibited?
A.CONCRETE
from regulating equipment, water heater, conditioning tank B.STEEL
C.PLASTIC
and similar equipment which require removal for servicing D.WOODEN
59. In order as not to impede the movement of a person in
or replacement?
A.2 ft wheel chair and to have a convenient access on the
B.1 m
C.5 ft lavatory, what is the allowable knee recess vertical
D.0.3 m
50. For at least how many working days shall a required for clearance that will be provided?
A.0.50 m to 0.80
inspection of the plumbing works be filed before such
m
inspection be intended? B.0.60 m to 0.80
A.7 working days
B.5 working days m
C.3 working days C.0.40 m to 0.70
D.10 working
m
days D.0.60 m to 0.70
51. What is the minimum pipe size of the standpipe if the
m
highest outlet is located more than 23 meters above the 60. According to Art 3.2.2.2 of PD 1096 what scope of work in
Fire Service connection? plan preparation for new sanitary installations with more
A.3 inches
B.6 inches than 20 units does a sanitary engineer differs with a
C.5 inches
D.4 inches Registered Master Plumber?
52. What is the masimum length of the fire hose that shall be A Det. all drawings of septic tanks in the absence of disposal
pipes? added
A.ASSE 77. What is the nimimum floor area in every storey which is
B.ASPE
C.ANSI used for habitation, recreation, dining, study of work and
D.IAPMO
68. In what year did NAMPAP was incorporated as a which has an occupiped load of not more than 20, wherein
fee joist
D.1/2 of the original fee B Adjust the joist to make it perpendicular with the direction of
70. For how many days shall the REvised National Plumbing
. pipe
Code will take effect following its complete publication in C.Space the joist wider to accommodate the pipe
D.Double the
the Official Gazette?
A.100 days joist
B.60 days 79. What is the minimum allowable interval for the support of
C.50 days
D.30 days plastic pipes when installed vertically
71. What is the maximum allowable lead content of pipe and A.2ft
B.5ft
fitting for potable piping system? C.1 meter
A.0% D.1.5 meter
B.2% 80. Except for plastic piping system, hot and cold water piping
C.5%
D.8% may be tested wtih ___
72. What is the minimum pipe size of the standpipe if the A 50 psi of the working pressure of the water in the system for
highest outlet is located 23 meters or less above the Fire . at least 15 minutes
B.100 psi air for at least 10 operation of deep wells for the abstraction of ground water
minutes Water
81. What is not needed to be installed when a combination C.Water Code of the Philippines
D.Code of Sanitation
standpipe system is installed in accordance with the Fire 89. Unless serving sinks or urinals, cleanouts may be omitted
connection meters
82. The following are the data required whenever a Registered C.Less than 1.5
drainage pipes between manholes is where raised heads may cause hazards to passing
A.2%
B.2 1/2% personnel or vehicles.
C.3% A.Depressed
D.4% B.Countersunk
96. What is the PRC Resolution Number is issued by the C.Embedded
D.Recessed
Board of Master Plumbing for the adoption and 104. According to Rep. Act 1378 for at leasrt how many years
promulgation of the Revised National Plumbing Code of the must the appointee to the Board of Master Plumbers must
semisolids heavier than water that would be harmful to the what kind of pipe should not be used in the excreta
filed STANDPIPE"?
C.Imhoff tank A.20mm
D.Settling B.1/4inch
C.25mm
chamber D.30mm
100. What is the minimum number of years of experience must 109. Aside from galvanized steel, what is the other material for
a Registered Master Plumber be before he can be a dry standpipe that the Building Code allows?
A.PVC pipe
technical staff of a Building Office? B.Wrought iron
A.One year C.PE pipe
B.Three years D.Brass
C.Two years 110. Aside from the number of fixture units connected to it, the
D.Five years
101. PD No. 1185 is another law that Master Plumbers used as size of the vent piping is determined by its
A.Number of inlets
their guide in the practice of the plumbing B.Length
C.Discharge
profession.What is PD No. 1185? D.Loading
A.Accessibilty Law 111. Which of the following is not included in a plumbing
B.Fire Code of the Philippines
C.Water Code of the Philippines unit?
D.Code of Sanitation A.Water Meter
102. How many units do the controversial Article 3.2.2.2 of PD B.Floor Drain
C.Urinal
D.Laundry Tray
112. For new, additional or altered plumbing installation not
patterned for?
A.Standard Plumbing Code
B.ASPE Code
C.Uniform Plumbing
Code
D.International Plumbing Code
http://www.proprofs.com/quiz-school/quizshow.php?